3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card Operation & User’s Manual
|
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, 3COM SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER’S OR ANY THIRD PERSON’S MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD. LIMITATION OF LIABILITY TO THE FULL EXTENT ALLOWED BY LAW, 3COM ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS
vi A S PECIFICATIONS 3C359 NIC Specifications A-1 Connector Pin Assignments A-3 DB-9 Connector Pin Assignments A-3 RJ-45 Connector Pin Assignments A-3 Cable Requirements A-4 B C HANGING C ONFIGURATION S ETTINGS Using the Configuration Program B-1 Adjusting Configuration Settings B-4 Ring Speed B-4 Boot
5-8 CHAPTER 5: IBM ENVIRONMENTS 5 In the Select Network Component Type window, select Protocol. Click Add. Windows builds the driver information database and displays the Select Protocol window. 6 Select Microsoft in the Manufacturers list. 7 Do one of the following: ■ If you are using Windows 95 version 950b, OSR2, select Microsoft 32-bit DLC in the Network Proto
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, Support from Your Network Supplier C-3 Local access numbers are available within the following countries: 3ComForum on CompuServe Online Service 3ComForum contains patches, software, drivers, and technical articles about all 3Com products, as well as a messaging section for peer support. To use 3ComForum, you need a CompuServe account. To use 3ComForum: 1 Log on to your CompuServe account. 2 Type go threecom 3 Press Return to see the 3ComForum main menu. Support from Your Network Supplier If additional assistance is required, contact your network suppl
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, C-6 APPENDIX C: TECHNICAL SUPPORT Returning Products for Repair Before you send a product directly to 3Com for repair, you must first obtain a Return Materials Authorization (RMA) number. Products sent to 3Com without RMA numbers will be returned to the sender unopened, at the sender’s expense. To obtain an RMA number, call or fax: Country Telephone Number Fax Number U.S.A. and Canada 1 800 876 3266, option 2 408 764 7120 Latin America 1 408 326 2927 408 764 7120 Europe, South Africa, and Middle East 44 1442 435860 44 1442 435822 E
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, Selecting Ring Speed 4-11 The default setting for Ring Speed is Auto. 5 To manually set the ring speed, select Ring Speed in the Property list. 6 Position the mouse pointer on the down arrow button in the Value field. Press and hold down the left mouse button. The Advanced tab appears, as shown in Figure 4-4. Figure 4-4 Manually Setting Ring Speed 7 Select one of the following values: ■ 16 — Disables auto ring speed detection and sets NIC ring speed at 16 Mbps ■ 4 — Disables auto ring speed detection and sets NIC ring speed at 4 Mbps ■ Auto — Allows NIC to automatically d
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, Installing a NetWare Server Driver 3-21 9 Press Enter to view a list of supported options for the selected parameter. Additional help for the parameter is also displayed in the lower text box. You can also find a description of parameters and explanations earlier in this chapter in “Using the Load Command.” 10 After you have made selections for all 3C359 NIC driver parameters, press F10 to save the parameters and load TLNKPODI.LAN. Then follow the prompts to complete the server installatio
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, Configuring IBM Host Connectivity 5-9 Adding the 32-Bit DLC Network Protocol for Windows NT Follow the steps in this section to add the Microsoft 32-bit DLC network protocol to the Windows NT Network Protocols list for the 3C359 NIC. The 32-bit DLC protocol is required for connectivity between your PC and an IBM host computer. 1 On the Windows NT desktop, double-click the My Computer icon. 2 Double-click the Control Panel icon. 3 Double-click the Network icon. 4 In the Network window, select the
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, B CHANGING CONFIGURATION SETTINGS You can change the 3C359 NIC’s configuration settings through a DOS Configuration and Diagnostic Program provided on TokenDisk diskette #1 and on the TokenDisk CD. This appendix provides configuration instructions. Instructions for testing the NIC with the diagnostic part of the DOS Configuration and Diagnostic Program are located in Chapter 6, “Troubleshooting.” Using the Configuration Program Before running the DOS Configuration and Diagnostic Program, perform a clean DOS boot from a DOS diskette (or the hard drive’s DOS option, if provided) to ensure that no memory managers or drivers are loaded. The Configuration and Diag
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, v Configuring Class of Service 4-19 Before Starting Class of Service Configuration 4-20 Enabling Class of Service 4-20 Adding Class of Service Ranges and Protocols 4-23 Using Class of Service Advanced Options 4-25 Class of Service Advanced Options Settings 4-26 5 IBM E NVIRONMENTS Installing a Driver for Various IBM Environments 5-1 Installing the IBM LAN Support Program (DXMAID) and the DOS NDIS 2.01 Driver 5-1 Installing a Driver for IBM DOS LAN Services 5-2 Using IBM MPTS to Install a Driver for OS/2 5-3 Configuring IBM Host
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, 3-14 CHAPTER 3: NOVELL NETWARE ENVIRONMENTS Deciding If Modules Need to Be Replaced At the server command prompt, enter MODULES. The resulting display shows what drivers and modules are currently running on the server. Locate the entries for MSM.NLM and TOKENTSM.NLM. (MSM31X.NLM appears as MSM.NLM.) If any of the versions currently running is earlier than 2.50, you must replace modules MSM31X.NLM, MSM.NLM, or TOKENTSM.NLM. The modules on TokenDisk diskette #1 are version 2.50. You can load the server driver as described later in this chapter in “Using the Load Command.” CAUTION: Using versi
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, 2-2 CHAPTER 2: INSTALLING THE 3C359 NIC 5 Reduce any static electricity on your body. Each NIC is packed in an antistatic container to protect it during shipment. To avoid damaging any static-sensitive components after removal from the container, be sure to reduce any static electricity on your body. One way to reduce static electricity is to touch an unpainted part of the computer’s metal chassis. You can maintain grounding by wearing an antistatic wrist strap attached to the chassis. 6 Verify that your tools are nonconducting or insulated. Your tools should include a flat-head screwdriver and a Phill
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, 6-4 CHAPTER 6: TROUBLESHOOTING Figure 6-2 Test Menu 2 From the Test pull-down menu shown in Figure 6-2, select Run Tests. The Run Tests dialog box appears, similar to the one shown in Figure 6-3. Figure 6-3 DOS Diagnostic Program Run Tests Dialog Box 3 Press Enter to start the tests. Each test runs once unless you specify otherwise. The test results are displayed with “Passed” or “Failed” in the Results column. Book Page 4 Saturday, November 1, 1997 3:13 PM
Installing a DOS 16-Bit Client Driver 3-3 3 If you are using the 3.5-inch diskettes, insert TokenDisk diskette #1 in the drive and enter: a: If you are using the TokenDisk CD, insert it in the CD-ROM drive and enter the drive letter. For example: d: 4 Enter: autolink An AutoLink information window is displayed. 5 From the AutoLink Information window, press Enter. The first tim
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, 3-4 CHAPTER 3: NOVELL NETWARE ENVIRONMENTS AutoLink Troubleshooting If you experience problems when using the AutoLink program, display or print the AUTOLINK.LOG file, which contains a log of the events that occurred during the AutoLink installation and configuration process. 1 To display the file, enter the following DOS command: type autolink.log | more 2 To print the file, connect to a local printer and enter: copy autolink.log prn or print autolink.log Installing a DOS 16-Bit Client Manually If you did not use the AutoLink configuration utility, follow these steps to install the DOS 16-bit client driver for NetWare: 1 Insert the Novell NetWare Client for DOS and Micro
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, Installing an OS/2 Client Driver for NetWare 3-7 11 When the path for the configuration files is displayed, verify that the path is correct and press Enter. 12 Press Enter again to return to DOS and edit the STARTNET.BAT file. 13 Add the NIC’s slot number in the STARTNET.BAT file as follows: load c:\novell\client32\tlnkpodi.lan frame=token-ring msb slot=<nnnn> where <nnnn> is the slot number. If you do not know your NIC’s slot number, you can turn off your PC, remove the cover, and check the slot. 14 On the same LOAD line, you can set the NIC’s ring speed as follows. load c:\novell\client32\tlnkpodi.lan..
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, B-4 APPENDIX B: CHANGING CONFIGURATION SETTINGS Use the arrow keys to select the option you want, pressing Enter to display the dialog box for each option. 6 When you have completed your configuration changes, press Tab until OK is selected. 7 Press Enter to save the new configuration settings for the NIC. Adjusting Configuration Settings Configuration for the 3C359 NIC is automatic for all operating systems. When you turn on the computer after installing the NIC, Plug and Play (PnP) automatically assigns all resources. Table B-1 lists the default configuration settings of the 3C359 NIC at shipment. Ring Speed The 3C359 NIC operates at a ring speed of either 4 or 16 Mbps
5 IBM ENVIRONMENTS This chapter describes how to install a 3C359 NIC network device driver for various IBM operating system environments. This chapter also describes configuring 3C359 NIC connectivity to an IBM host computer (mainframe or AS/400) for various Windows environments. Installing a Driver for Various IBM Environments This section describes how to install a 3C359
3Com TokenLink Velocity TokenLink VelocityTM XL PCI Network Interface Card, 4-16 CHAPTER 4: MICROSOFT WINDOWS ENVIRONMENT Figure 4-7 Network Window 3 In the Configuration tab, select 3Com TokenLink Velocity XL PCI Adapter and click Properties. The Driver tab of the 3Com PCI Token Ring Adapter Properties window appears, as shown in Figure 4-8. 4 Click the Advanced tab. The Advanced tab of the 3Com PCI Token Ring Adapter Properties window appears, as shown in Figure 4-9. Book Page 16 Saturday, November 1, 1997 3:13 PM
3Com Etherlink 100 PCI Network Card Manual
Etherlink 100 PCI |
3Com 3CR292-DE56 Network Card Quick installation manual
3CR292-DE56 |
3Com 09-1457-000 Network Card Operation & user’s manual
09-1457-000 |
3Com 3C319 Network Card Release note
3C319 |
3Com 3C905-TX Network Card Installation manual
3C905-TX |
3Com 3C319 Network Card Quick start
3C319 |
3Com 3C996B-T Network Card Operation & user’s manual
3C996B-T |
3Com EISA 10/100BASE-T Network Card Operation & user’s manual
EISA 10/100BASE-T |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | BSS Audio | 9014 | Installation manual | bss-audio/9014-3QO.pdf | 18 Jan 2024 | 5 | 0.25 Mb |
2 | AOC | 712Swa-1 | Operation & user’s manual | aoc/712swa-1-TRG.pdf | 02 Jul 2023 | 46 | 1.33 Mb |
3 | Palsonic | DVD2080HD | Operation & user’s manual | palsonic/dvd2080hd-P94.pdf | 07 Jan 2023 | 16 | 1.07 Mb |
4 | NEC | MultiSync FP1350X FP1350X FP1350X | Specifications | nec/multisync-fp1350x-fp1350x-fp1350x-6O3.pdf | 22 Oct 2023 | 2 | |
5 | ViewSonic | CD5233I | Operation & user’s manual | viewsonic/cd5233i-317.pdf | 30 Nov 2022 | 52 | 2.39 Mb |
6 | Extech Instruments | MN62 | Operation & user’s manual | extech-instruments/mn62-3S5.pdf | 21 Aug 2023 | 19 |
TRENDnet
TM The 300Mbps Wireless Easy-N-Upgrader upgrades your old, perfectly functioning router, to high speed wireless n. Enjoy up to 12 times the speed and 6 times the coverage of a wireless g networkEliminate wireless dead spots, seamlessly surf the Internet and help the environment by not throwing away your old router. TMThe compact 300Mbps Wireless Easy-N-Upgra …
300Mbps Wireless Easy-N-Upgrader TEW-637AP(2 pages) |
Omnitron Systems Technology
iConverter® Wall-Mounting KitUser InstructionsDescription and InventoryThe 8249-0 iConverter Wall-Mounting kit wasdesigned to attach one iConverter 1-Module or 2-Module chassis to a wall, backboard or other flatsurface. The 8249-0 kit should include the followinghardware:(2) “L” shaped brackets(4) Flat head screws, 4-40, 1/4 inch(4) Wall mounting screws …
iConverter Wall-Mounting Kit 8249-0(1 pages) |
Texas Instruments
Application ReportSPRA545A - September 20011TMS320C6000 Host Port to MC68360 InterfaceZoran Nikolic Digital Signal Processing SolutionsABSTRACTThis application report describes an interface between the Motorola MC68360 quadintegrated communication controller (QUICC) and the host port interface (HPI) of aTMS320C6000 (C6000) digital signal processor (DSP …
TMS320C6000(18 pages) |
ZyXEL Communications
HomePlug AV Powerline Ethernet Adapterpla-401Extends LAN Solutions through Existing Electrical LinesThe ZyXEL HomePlug AV PLA-401 is an extended access solution that allows your house to be completely networked using your existing electrical power lines. With no need for additional wiring, simply plug the ZyXEL HomePlug AV PLA-401 to an existing electrical o …
PLA-401 - V3.0.5(2 pages) |
Belkin
User ManualF5D7000Belkin Corporation501 West Walnut StreetCompton • CA • 90220 • USATel: 310.898.1100Fax: 310.898.1111Belkin Components, Ltd.Express Business ParkShipton Way • Rushden • NN10 6GLUnited KingdomTel: +44 (0) 1933 35 2000Fax: +44 (0) 1933 31 2000Belkin Components B.V.Starparc Building • Boeing Avenue 3331119 PH Schiphol-Rijk • The N …
F5D7000(19 pages) |
D-Link
CD SET-UP WIZARDSET-UP AND CONFIGURATION PROBLEMSDWA-171 WIRELESS AC DUAL BAND USB ADAPTER The CD contains software drivers and manual which can be obtained from D-Link (see Te …
DWA-171(2 pages) |
Sonim Cell Phone XP2.10 SPIRITSonim Cell Phone XP2.10 SPIRIT Specification XP2.10 SPIRIT, 2 |
Gardner Denver Water Pump GD-250Gardner Denver Water Pump Operating and service manual (File: gardner-denver-gd-250-operating-and-service-manual-34, 25th Nov 2023) GD-250, 34 |
Bosch IP Camera NII-41012-V3Bosch IP Camera NII-41012-V3 Quick installation manual NII-41012-V3, 2 |
Sanus Indoor Furnishing LF228Indoor Furnishing Instructions manual (Sanus LF228) LF228, 38 |
Crate&Barrel Indoor Furnishing ColetteIndoor Furnishing Manual (Crate&Barrel Colette) Colette, 4 |
Samsung Cell Phone SCH-I910#QHCLHX: SCH-I910 Cell Phone Software manual SCH-I910, 209 |
Nilfisk-Advance Blower SR 1300H BSR 1300H B Operation & user’s manual - OVXA6Y SR 1300H B, 124 |
Murphy Switch M-6797BPDF User Manual (@7RN8E3), Murphy M-6797B Switch (15/01/2024) M-6797B, 4 |
Zelmer Scales 34Z017Zelmer 34Z017 User Manual (Operation & user’s manual), @1FJYP6 34Z017, 28 |
Contec Universal Remote Synergy V A189CContec Universal Remote Synergy V A189C Programming and operating instructions Synergy V A189C, 7 |
AT&T Telephone E2555Telephone Operation & user’s manual (AT&T E2555) E2555, 25 |
Digital Equipment Desktop VAX 4000 Model 500AVAX 4000 Model 500A Installation manual - D1T97Y VAX 4000 Model 500A, 72 |