Manualios.com

Maxlogic ML-221XX series Operation & User’s Manual

  • ML-221XX series Fire Alarms
  • maMXnvUO2FOqw
  • Operation & User’s Manual
  • PDF / Adobe Acrobat Reader
  • 16

Maxlogic ML-221XX series Manual Online:

4.3, 2509 votes
Maxlogic ML-221XX series User Manual
Maxlogic ML-221XX series User Guide
Maxlogic ML-221XX series Online Manual

Text of Maxlogic ML-221XX series User Guide:

  • Maxlogic ML-221XX series, CONTENTS No Section Page Introduction Warning Mounting Inputs Outputs Controls Indicators Fuses Panel conditions Menu Modes Technical Specifications Santral Models Accessories and Options Annex - A : Panel Wiring Diagram Annex - B : Panel Dimensions Annex - C1 : Panel Serigraphy Annex - C2 : Panel Serigraphy Annex - C3 : Panel Serigraphy Annex - C4 : Panel Serigraphy 1 2 3 4 5 6 7 8 9 10 11 12 13 Annex Page 2/16KK-642.042 Rev.No:0 01.11.12 ML-221XX User Manual 3 3 4 4 4 5 5 6 6 7 7 8 8 11 12 13 14 15 16

  • 1- INTRODUCTION 2- WARNINGS Producer-manufacturer or importer firms’ title, address, and telephone number Manufacturer Firm: MAVILI ELEKTRONIK TICARET VE SANAYI A.S. SERIFALI MAHALLESI, KUTUP SOKAK NO: 27/1-2-4 UMRANIYE - ISTANBUL - TURKEY TEL: +90 216 466 45 05 - +90 216 466 45 10 Service stations’ communication information that related spare parts have been

  • 3- MOUNTING 4- INPUTS 5.1 SOUNDER OUTPUT The panel has two supervised sounder output rated 0.5А 24V DC. Overloading the output will cause a sounder output fault and fuse activation. A 2x1.5 mm2 cable must be used as a sounder circuit. 10кΩ resistor, located on sounder output from factory default is used as end-of-line element. 5.2 AUXILIARY POWER SUPPLY OUTPUT The panel is equipped w

  • Maxlogic ML-221XX series, 5.1 SOUNDER OUTPUT The panel has two supervised sounder output rated 0.5А 24V DC. Overloading the output will cause a sounder output fault and fuse activation. A 2x1.5 mm2 cable must be used as a sounder circuit. 10кΩ resistor, located on sounder output from factory default is used as end-of-line element. 5.2 AUXILIARY POWER SUPPLY OUTPUT The panel is equipped with an auxiliary 0.5А 24V DC power supply output. The output is used for energising external devices such as telephone dialler or gas detector. Connecting an external device with improper voltage requirement or overloading the output wil

  • Maxlogic ML-221XX series, 7.1 Front case indicators Power On Continuous illumination indicates that the panel is energised. Flashing indicates fault in mains or battery power supply. General Fault Illumination indicates any fault condition. This would typically be: - Mains power supply or battery voltage is low, - Leak from ‘+’ or ‘-‘ wire to earth, - Open or short circuit on the sounder circuit, - Open or short circuit on the zone circuits, - Overloading of the auxiliary power supply output. Power Fault Illumination indicates power supply fault c

  • Maxlogic ML-221XX series, 10.1. TEST MODE In Test Mode, manually initiated fire condition is automatically reset in a few seconds by the panel. The Test Mode causes continuous illumination of the respective zonal Fault LED. Steps taken for entering and quitting the Test Mode are as follows: - Set the Button Control key to Enable position. The buzzer will sound once. - Press the Silence Buzzer button, then, keeping the button pressed, press the Silence / Sound Alarm button till Alarm / Buzzer Silenced, FIRE and GENERAL FAULT LEDs start to illuminate. This will take about 5 seconds. - Zone 1 FAULT LED will start to illuminate. Move to the zone required by pressi

  • Maxlogic ML-221XX series, 12- SANTRAL MODELS 13 - ACCESSORIES AND OPTIONS Product Code ML-22102 ML-22104 ML-22108 ML-22116 MLY-2210 MLY-2211 MLY-2212 MLY-2213 MLY-2214 MLY-2215 MLY-2216 MLY-2217 MLY-2218 8 way Relay card 8 way Sounder card Network card Memory card Network & Memory card 4 way relay card 4 way sounder card 2 way relay card 2 way sounder card 2 4 8 16 Zone Capacity Product Code Product Name Page 8/16KK-642.042 Rev.No:0 01.11.12 ML-221XX User Manual

  • Maxlogic ML-221XX series, Page 9/16KK-642.042 Rev.No:0 01.11.12 ML-221XX User Manual 13.2 - 8 way Sounder card (MLY-2211) • Sounder module provides zonal sounder output for Maxlogic ML-221XX series conventional panels. • Each sounder output has 24V DC 100 mA. 13.3 - Network Card (MLY-2212) Network module provides to makenetwork connection up 32 panels with MGRP-64 Repeater panel. CONN1 jumper should be mounted on the networ

  • Maxlogic ML-221XX series, Page 10/16KK-642.042 Rev.No:0 01.11.12 ML-221XX User Manual Network Card (MLY-2212), Mermory Card (MLY-2213), Network and Memory Card (MLY-2214) Wiring Diagram

  • Maxlogic ML-221XX series, Page 11/16KK-642.042 Rev.No:0 01.11.12 ML-221XX User Manual Annex-A: Panel Wiring Diagram

  • Maxlogic ML-221XX series, Page 12/16KK-642.042 Rev.No:0 01.11.12 ML-221XX User Manual Annex -B: Panel Dimensions 400mm 300mm 100mm

  • Maxlogic ML-221XX series, Page 13/16KK-642.042 Rev.No:0 01.11.12 ML-221XX User Manual Annex -C1: Panel Serigraphy

  • Maxlogic ML-221XX series, Page 14/16KK-642.042 Rev.No:0 01.11.12 ML-221XX User Manual Annex -C2: Panel Serigraphy

  • Page 15/16KK-642.042 Rev.No:0 01.11.12 ML-221XX User Manual Annex -C3: Panel Serigraphy

  • Maxlogic ML-221XX series, Page 16/16KK-642.042 Rev.No:0 01.11.12 ML-221XX User Manual Annex -C4: Panel Serigraphy

Related Products and Documents (Fire Alarms):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Behringer MX3242X Operation & user’s manual behringer/mx3242x-7DR.pdf 20 Mar 2023 39
2 Troy-Bilt 1905 Owner's manual troy-bilt/1905-466.pdf 30 Sep 2022 40 2.01 Mb
3 Metro DataVac Re-Charge Pack Premium Operation & user’s manual metro-datavac/re-charge-pack-premium-E62.pdf 14 Aug 2023 8
4 Invacare PLATINUM 5 Operator's manual invacare/platinum-5-6W8.pdf 23 Nov 2023 148
5 Hitachi CP-X265 User's manual and operating manual hitachi/cp-x265-79X.pdf 29 Jul 2023 122 10.85 Mb
6 Lexmark C792 Family Datasheet lexmark/c792-family-72N.pdf 25 Jan 2024 8

Similar Resources:

  • Teletek electronics

    SensoIRIS BSOU

    (2 pages)
    SensoIRIS BSOUOperating Voltage Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Voltaje de alimentación . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Захранващо напрежение . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 - 32VDCMaximal consumption at communication . . . . . . . . . …
  • FireClass

    Prescient III

    (60 pages)
    Application, Installation & Commissioning120.515.161_FC-P-PRESCIENT3-I-NLDoc. version 224. February 2014Conventional Fire Detection & Gas Extinguishing Control PanelFIRECLASS Prescient III …
  • Simplex

    4100ES

    (8 pages)
    Features Emergency voice/alarm communications provide:  Alarm/evacuation signal generation with multiple built-in tones  Standard or customized digital message storage and message generation  Automatic or manual operation  Mass Notification operation Multiple channels are available:  Analog audio systems provide dual channel operation � …
  • Protec

    4400

    (88 pages)
    93-310-10 Issue 4 Rev 5 Page 1 of 88 Copyright Protec Fire Detection PLC 6400 OPERATING MANUALIISSSSUUEESSISSUE DATE RELEASED DETAILS OF CHANGE AUTHOR4 …
  • Simplex

    4090-9001

    (2 pages)
    Mechanically Installing the Supervised IAM Install the Supervised IAM into a UL Listed single-gang, 4-inch square, or 4-inch octagonal electrical box (not supplied) using Figure 4 as a reference. Mount the Supervised IAM to the electrical box as follows: 1. Insert the Supervised IAM into the electrical box; the attached field wiring holds the Supervised …
  • Brooks

    FIRETRACKER FT128

    (6 pages)
    2022/01/06 FT128 Quick Operation Guide Page 1 of 6 FIRETRACKER FT128 FIRE ALARM SYSTEM QUICK OPERATION GUIDE 1 - TO SILENCE PANEL BUZZER: Press Button once to silence panel buzzer. Caution. Pressing the Button again will cause the buzzer to resound. 2 -TO SILENCE ALARM DEVICES: Press Button once to silence all alarm devices, sounders o …

Comments, Questions and Opinions: