NewMar MDP-25.0 Installation/operating
|
NewMar MDP-25.0, P.O. Box 1306 Newport Beach California 92663 Phone: 714-751-0488 Fax: 714-957-1621 E-Mail: [email protected] www.newmartelecom.com Topic Page Quick Reference Guide............................................. 2 Operational Features Summary............................... 3 Materials Provided.................................................... 3 Installation................................................................ 3 Mechanical Power Wiring Signal Wiring Motorola Output Settings: Default and Optional Operation..................................
NewMar MDP-25.0, P.O. Box 1306 Newport Beach California 92663 Phone: 714-751-0488 Fax: 714-957-1621 E-Mail: [email protected] www.newmartelecom.com Quick Reference Guide Status LEDs Page 5 Status LED Legend Page 5 D-Sub 9 Pin Motorola Interface Page 4 Input/Output Wiring Page 3 Fuses Page 3 Time Out Programming (Side of Unit) Page 5 1
NewMar MDP-25.0, P.O. Box 1306 Newport Beach California 92663 Phone: 714-751-0488 Fax: 714-957-1621 E-Mail: [email protected] www.newmartelecom.com Features: •Protectsmobilecomputersagainstsystemcrashpreventinglengthyrebootsequencesandlossofdatadueto: •Voltagedipduringenginecranking. •Voltagedropanddecayduetoloadinghighpoweraccessoriesandagingbatteries. •Providessupplementalvoltageinmili-secondstomobilecomputerswhenlowvehiclebatteryissensed,ensuring�
NewMar MDP-25.0, P.O. Box 1306 Newport Beach California 92663 Phone: 714-751-0488 Fax: 714-957-1621 E-Mail: [email protected] www.newmartelecom.com MATERIALS PROVIDED TheMDP-25.0issuppliedwiththefollowingmaterials: (4) # 8 ring lugs for 8 gauge wire (1) Terminal block cover (attached) (1) Installation/Operation Manual Checktoseethatthesehavebeenincludedwiththepackaging.Foranymissingitems,pleasecontactFactory. INSTALLATION Mechanical: Locate a flat surface close to the power line that feeds the electronics. For best results, the MDP should be within 24” of the critical electro
NewMar MDP-25.0, P.O. Box 1306 Newport Beach California 92663 Phone: 714-751-0488 Fax: 714-957-1621 E-Mail: [email protected] www.newmartelecom.com 1 4 3 2 5 6 9 8 7 Ignition OUT Ignition IN Charge/Discharge Not Used Not Used Not Used Not Used Not Used - INPUT 4 Motorola Output Signals: The MDP is programmed to provide early warning signals to mobile data computers designed for this input (such as Motorola®MW800Seriesworkstationsandvideorecordingsystemcameras.)Interf
NewMar MDP-25.0, P.O. Box 1306 Newport Beach California 92663 Phone: 714-751-0488 Fax: 714-957-1621 E-Mail: [email protected] www.newmartelecom.com Status LEDs Refer to the illustration below for location of the front panel status indicator lights: 1.‘CHARGING’GreenLEDactivateswhencharge-modebeginsor,INPUTpowerisappliedforthersttimeandindicates Back-upbatteryisbeingcharged. Charging Color Status AMBER Bulk/Hi Rate GREEN Float OFF ChargerOff Flashing RED C
P.O. Box 1306 Newport Beach California 92663 Phone: 714-751-0488 Fax: 714-957-1621 E-Mail: [email protected] www.newmartelecom.com 6 1.IftheMDP-25.0isalreadyinstalled,turnoffall12voltloadsconnectedtotheoutputanddisconnectthe12voltinput. If unable to remove power first,
P.O. Box 1306 Newport Beach California 92663 Phone: 714-751-0488 Fax: 714-957-1621 E-Mail: [email protected] www.newmartelecom.com Advanced settings (Technician Recommended): Back-Up Timer, Trigger Threshold and Hysteresis Factory Defaults Setting Factory Default TMR Disconnect Time Notactivated Back-UpTimer(battery) 15min. Back-UpTriggerVoltage 10.
NewMar MDP-25.0, P.O. Box 1306 Newport Beach California 92663 Phone: 714-751-0488 Fax: 714-957-1621 E-Mail: [email protected] www.newmartelecom.com Table 4 Table 5 S4 - Back-Up Hysteresis Pos 4 Pos 5 Pos 6 1Volts OFF OFF OFF 1.2Volts ON OFF OFF 1.4Volts OFF ON OFF 1.6Volts ON ON OFF 1.8Volts OFF OFF ON 2.0Volts ON OFF ON 2.2Volts OFF ON ON 2.4Volts ON ON ON INTERNAL BATTERY CHARGING & REPLACEMENT: TheMDPinternalbatteryisasealedlea
NewMar MDP-25.0, P.O. Box 1306 Newport Beach California 92663 Phone: 714-751-0488 Fax: 714-957-1621 E-Mail: [email protected] www.newmartelecom.com 9 TEST / TROUBLESHOOTING RefertothestatusLEDindicatorlegendonpage5,whichprovidesdiagnosticsofwhatstagetheMDPiscurrently operating. 1) Testing Battery Back-up Function: With a load connected to MDP output remove input fuse and confirm load is powered without interruption from MDP internalbattery:ThetwoGREENLED’s(“CHARGING”&“INPUTCONNECTED”)shouldextinguishandtheAM
NewMar MDP-25.0, P.O. Box 1306 Newport Beach California 92663 Phone: 714-751-0488 Fax: 714-957-1621 E-Mail: [email protected] www.newmartelecom.com DIMENSIONAL DRAWINGS: 6.980 8.460 5.400 4.750 .300 6.000 ∅.281 x 4 5.790 10
Emerson NXr UPS Operation & user’s manual
NXr |
MGE UPS Systems Pulsar EX7 UPS Operation & user’s manual
Pulsar EX7 |
Long-run UPS Series UPS Manual
UPS Series |
Tripp Lite SmartPro SMART1500RM2U UPS Specification sheet
SmartPro SMART1500RM2U |
Delta RT5k UPS Operation & user’s manual
RT5k |
Tripp Lite BC Personal UPS Owner's manual
BC Personal |
IBM 500 UPS Service manual
500 |
Advantech DLT-U1100 UPS Manual
DLT-U1100 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | GE | Hotpoint RGA724PK | Specifications | ge/hotpoint-rga724pk-BPD.pdf | 22 Oct 2022 | 2 | 0.17 Mb |
2 | Rane | AP 13 | Schematic diagram | rane/ap-13-15U.pdf | 09 Dec 2022 | 4 | 0.32 Mb |
3 | KTM | 50 SX | Repair manual | ktm/50-sx-7WH.pdf | 04 Feb 2023 | 159 | |
4 | Yamaha | YX500R | Owner's manual | yamaha/yx500r-J4G.pdf | 22 Jun 2022 | 12 | |
5 | Nikon | Z 7 | Professional technical manual | nikon/z-7-F39.pdf | 29 May 2023 | 14 | |
6 | RUD | PSA-VRS | Safety instructions | rud/psa-vrs-R3V.pdf | 25 Feb 2023 | 6 |
Eaton
www.eaton.comInstallation and User ManualManuel d’installation et d’utilisationManual de instalación y de usuarioManual de instalação e do usuárioEnglishFrançaisEspañolPortugueseEX700 – 1000 – 1500 1000 RT2U – 1500 RT2U EXB 1000/1500 EXB 1000/1500 RT2UPulsar Series
…
EX 1000(120 pages) |
Eaton
--24-- www.eaton.com/dxups USER MANUAL ON LINE UPS 1000H(XL)/2000H(XL)/3000H(XL)/6000H(XL)/10000H(XL) Uninterruptible Power Supply
…
1000H(XL)(40 pages) |
Eaton
700 VA - 3000 VA UPS ■User’s and Installation Manual■ IEMC Statements FCC Part 15 NOTICE: Pursuant to section 15 of the FCC rules, this product has been tested and thereby complies to the conditions of a Class B (700-1500VA) and Class A (2000-3000VA) digital device, which have been established for offering sufficient protectio …
700VA(19 pages) |
Eaton
91PS 15 kW 91PS 15 kW 91PS 15 kW 91PS 30 kW 93PS 20 kW 93PS 20 kW 93PS 20 kW 93PS 40 kW SAFETY AND INSTALLATION QUICK GUIDE Eaton 93PS UPS 8-40 kW Document ID Eaton 91PS/93PS UPS750 mm 480 mm 1750 mm 1300 mm 335 mm 750 mm 645 mm 335 mm 750 mm 216.15.15.2%100% 0 % 20 % 40% 60% 80 %95 %0 ºC 10 ºC 20 ºC 30 ºC 40 ºC …
91PS(138 pages) |
Puls
UB10.241 – U Series 24V, 10A March 2006 DS-UB10.241-ENRev 2.0 / All parameters are specified at 24V, 10A and 25°C ambient unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 1/11 DC-UPS ■ Requires only one 12V battery ■ Regulated output voltage in buffer mode ■ Compact, width only 49mm ■ 50% power reserves ■ …
DIMENSION U Series(11 pages) |
GE
GE Multilin's Quality Management System is registered to ISO9001:2000QMI # 005094GE Digital EnergyMultilinGE Multilin215 Anderson Avenue, Markham, OntarioCanada L6E 1B3Tel: (905) 294-6222 Fax: (905) 201-2098Internet: http://www.GEmultilin.comInstruction manual350 revision: 1.2Manual P/N: 1601-9091-A4GE publication code: GEK-113509CCopyright © 2009 GE M …
ML Series 350(190 pages) |
Linn Water Pump Pipe Pump L3Pipe Pump L3 (Water Pump ePDF User Manual, #A94M12) Pipe Pump L3, 2 |
Maytag Dryer D-8Maytag D-8 Manual (Doc Type: Dryer Operation & user’s manual) D-8, 24 |
Saunier Duval Boiler Xeon 30ffBoiler PDF Instructions for use installation and servicing Xeon 30ff, 40 |
RCA Docking Station RS2300Operation & user’s manual for RCA RS2300 Docking Station RS2300, 20 |
REVELL Speakers Concerta IC65#XPY324 Concerta IC65: REVELL Speakers Owner Documentation Concerta IC65, 16 |
CMC Rescue Security Sensors MPDCMC Rescue Product User Guide: MPD PDF Operation & user’s manual - B439OY MPD, 24 |
Leica Binocular geovid 8x42 HD-Rgeovid 8x42 HD-R (Binocular ePDF Manual, #18QVB8) geovid 8x42 HD-R, 132 |
Compaq Storageworks Camera Accessories External Cache BatteryInstalling instructions for Compaq Storageworks External Cache Battery Camera Accessories External Cache Battery, 5 |
Lexus Automobile LS460 Navi UOwners book for Lexus LS460 Navi U Automobile LS460 Navi U, 805 |
IBM Desktop RS/6000 44P 170IBM Desktop Installation manual (File: ibm-rs6000-44p-170-installation-manual-86, Wednesday 31-01-2024) RS/6000 44P 170, 86 |
Lars Thrane Receiver LT-300Receiver PDF User & installation manual LT-300, 47 |
ViewSonic Monitor VX2453mhSpecifications for ViewSonic VX2453mh Monitor VX2453mh, 2 |