Manualios.com

Middle Atlantic Products UPS-2200R-HH Operation & User’s Manual

Middle Atlantic Products UPS-2200R-HH Manual Online:

4.8, 1495 votes
Middle Atlantic Products UPS-2200R-HH User Manual
Middle Atlantic Products UPS-2200R-HH User Guide
Middle Atlantic Products UPS-2200R-HH Online Manual

Text of Middle Atlantic Products UPS-2200R-HH User Guide:

  • Middle Atlantic Products UPS-2200R-HH, 082410-01 I-00462 Rev D UPS-2200R-HH/UPS-2200R-HHIP RACKMOUNT UNINTERRUPTIBLE POWER SUPPLY USER MANUAL THANK YOU Thank you for purchasing the UPS-2200R-HH/UPS-2200R-HHIP Rackmount UPS. The UPS provides battery backup during power outages, automatic voltage regulation during periods of inconsistent utility power and surge protection. Please read this manual before removing the UPS from the shipping carton and before making any connections to and operating your UPS. IMPORTANT U L R C US LISTED

  • Middle Atlantic Products UPS-2200R-HH, Page 2 TABLE OF CONTENTS Page No. Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Middle Atlantic Products Green Power UPS Technology . . . . . . . . . . . . . . . . . Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation and Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 6 Front Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rear Panel Description . . . . . . . . . .

  • Middle Atlantic Products UPS-2200R-HH, WARNING: The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection. DO NOT plug the UPS into an outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the UPS. WARNING: The internal battery in this UPS is always charged. The battery can energize hazardous live parts inside the unit, even when the AC input power is disconnected. WARNING: To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area, free of conductive con

  • Middle Atlantic Products UPS-2200R-HH, MIDDLE ATLANTIC PRODUCTS GREEN POWER UPS TECHNOLOGY CIRCUIT DIAGRAM Our new UPS circuit is designed to save energy operating in Green Power Bypass Mode. Middle Atlantic Product's Green Power circuit design is a solution to this "Power Loss". When the utility power is operating normally, our Green Power UPS works in Bypass Mode. Our Green Power design conducts power only through the relay and still provides normal output voltage. Bypassing the transformer reduces power consumption thereby conserving energy and saving money. When the utility power is abnormal the UPS will operate under Battery or AVR

  • Middle Atlantic Products UPS-2200R-HH, Page 5 UNPACKING (1) UPS Unit; (1) User’s Manual; (2) Rack Ears; (14) 10-32 Rack Ear Screws; (8) Nylon Rivets (Used to plug four front screw holes for mounting ears if the unit will not be rack mounted); (1) Telephone Cable (black); (2) Rackmount Handles; (4) 8-32 Rackmount Handle Screws; (1) Emergency Power Off Cable (gray); (1) Middle Atlantic Power Manager Software CD; (2) Serial Interface Cable (DB-9); (1) USB Cable; (1) Warranty Registration Card CAUTION : DO NOT LIFT THE UPS WHILE HOLDING THE FRONT FACE OF THE UNIT. THIS MAY DAMAGE THE UNIT. ALWAYS LIFT THE UPS BY HOLDING IT BY BOTH SIDES. LIFT OUT OF BOX WHILE HOLDING BOTH SIDES

  • Middle Atlantic Products UPS-2200R-HH, Page 6 One Person Installation: 1) Determine mounting location. 2) Install the Rear Mounting Brackets as shown. One Bracket is longer then the other to provide guidance when doing a one person installation. These brackets are interchangeable. (FIGURE A) IMPORTANT NOTE: Rear Mounting Brackets mount between the two corresponding rackspaces in the front of the enclosure. (FIGURE B) 3) Carefully lift the unit to the mounting position constantly supporting the bottom. Place the slide on the unit’s

  • Middle Atlantic Products UPS-2200R-HH, FRONT PANEL DESCRIPTION Power Switch: On/off switch to turn UPS on and off. Power on indicator : Indicates the UPS is turned on. LCD display: The LCD display indicates a variety of UPS operational conditions (see page 15 for LCD display definitions). LCD display toggle button : Toggles between a variety of UPS operational conditions (see page 15). REAR PANEL DESCRIPTION Non-Critical Load Circuit Breaker: Circuit output resettable circuit breaker. Provides overload protection. 7 Junction Box Cover: Remove to access wiring for critical and non-critical output circuits. Circuit wiring is labeled accordingly. (See

  • Middle Atlantic Products UPS-2200R-HH, REAR PANEL DESCRIPTION CONTINUED Serial Port Secondary I/O: Analog input/output pinout shown below will provide status for remote monitoring of the UPS. Communication protection ports RJ11/RJ45: Protects against surges on a single phone, fax, modem or Ethernet network lines. EPO (Emergency Power Off) Port: The EPO port may be used to connect the UPS to a contact closure switch or control system to enable emergency shutdown (see page 16). Serial Port Primary : The serial port primary allows for communication with a PC (through RS232) or a control system. (Please Note: The USB and Serial

  • Middle Atlantic Products UPS-2200R-HH, REAR PANEL DESCRIPTION CONTINUED Critical Load Receptacle: Critical load receptacle, NEMA 5-20R. 21 Critical Load Output Connector Knock-Out: 125 VAC, 50/60 Hz, 16A. (Trade size ½”) Non-Critical Load Output Connector Knock-Out : 125 VAC, 50/60 Hz, 16A. (Trade size ½”) 22 Hardwired Power Input: 3’ hardwired input cord. Remove the protective piece in the hole where the hardwired input goes into the UPS. When wiring is complete, slide the snap-in connector (24) into the knock-out until it is fully inserted. (See page 11 for hardwired input installation instructions) 23 Snap-in Connector: Slide the connector into the knock-out a

  • Middle Atlantic Products UPS-2200R-HH, INSTALLING HARDWIRED OUTPUTS 1) Remove the J-Box cover (6) and the knock-out cover from the desired output (21 & 22). Remove the conductors from the J-Box. 3) Splice conductors together using provided twist-on wire connectors. (factory installed on circuit wiring in the J-Box) CAUTION: Use only twist-on connectors supplied with UPS, or equivalent Listed twist-on connectors suitable for output conductor connections 2) Insert cable connector (installer provided) while guiding conductors to the J-Box opening. Slide on lock-nut and and ti

  • INSTALLING HARDWIRED INPUT (MODELS UPS-2200R-HH/UPS-2200R-HHIP ONLY) 1) Remove the protective shipping bushing from the hardwired input knock-out. 3) Insert the snap-in connector fully into the knock-out. There will be an audible click when the connector is fully inserted. 2) Grab and hold the three conductors at the end of the hardwired input cord (23). Gently sli

  • Middle Atlantic Products UPS-2200R-HH, SETUP OF UPS-IPCARD Page 12 Definitions for LED Indicators Link LED color Off On (Yellow) RX/TX LED color Off On (Green) Flashing Condition The UPS Network Interface Card is not connected to the Network or the UPS Network Interface Card power is off The UPS Network Interface Card is connected to the Network   The UPS Network Interface Card power is off The UPS Network Interface Card power is on - Receiving/transmitting data packet - Reset completed Ethernet connector LINK Indicator RX/TX Indicator Configuring the IP address for the Middle Atlantic Network Interface Card 1) Install the

  • Middle Atlantic Products UPS-2200R-HH, SETUP OF UPS-IPCARD CONTINUED Page 13 4) Select the SNMP card you are setting up. Click on the Tools menu and select “Device Setup” or double click the SNMP card you want to configure. 5) You can modify the IP Address, Subnet Mask, and Gateway address for the Device MAC Address listed in the Device Network Settings window, as shown in (FIGURE B) . The default IP Address is 192.168.20.177, the default Subnet Mask is 255.255.255.0. (FIGURE B) (FIGURE C) (FIGURE D) 6) Mod

  • Middle Atlantic Products UPS-2200R-HH, SETUP OF UPS-IPCARD CONTINUED Page 14 Method 2: Using a Command Prompt 1) Obtain the MAC address from the label on the UPS Network Interface Card rear panel. Each UPS Network Interface Card has a unique MAC address. 2) Use the ARP command to set the IP address. Example: To assign the IP Address 192.168.20.240 for the UPS Network Interface Card, which has a MAC address of 00-0C-15-00-00-01 you will type in the following command prompt from a PC connected to the same network as the UPS Network Interface Card. (1) Type in “arp-s 192.168.20.240 00-0C-15-00-00-01” then press ‘E nter’. 3) Use the Ping command to assign a size of 123 bytes to the IP. (1) Type in “pi

  • Middle Atlantic Products UPS-2200R-HH, Input Voltage Meter: Measures the incoming AC voltage that the UPS is receiving from the mains power connection. Output Meter : Displays the output AC voltage, frequency and wattage that the UPS is providing. Battery Icon : When operating on battery, this icon appears and an alarm sounds (two short beeps followed by a pause) indicating the UPS is operating from its internal battery. Normal Icon : This icon appears when the UPS is functioning normally. AVR (Automatic Voltage Regulato

  • BATTERY CHARGING The UPS is shipped from the factory with its internal battery fully charged. However, the battery may lose some charge during shipping and storage. Recharging the battery for at least four hours is recommended to ensure that the battery's maximum charge capacity is achieved. The UPS is equipped with an auto-charge feature. When the UPS is plugged into main

  • Middle Atlantic Products UPS-2200R-HH, OPERATION CAUTION: DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into the UPS. The power demands of these devices will overload and possibly damage the UPS. 1) Plug the UPS into a grounded wall receptacle. Ensure the wall receptacle is protected by a fuse or circuit breaker and does not service other equipment with large electrical demands (i.e. air conditioner, refrigerator, copier, etc.) 2) Press the Power Switch to turn the UPS on. The Power On

  • Middle Atlantic Products UPS-2200R-HH, 1) Press the Select button on the front panel to view each UPS status item listed in Table 1. Each item will display in the order shown. ORDER STATUS ITEM UNIT 1 Input Voltage V 2 Output Voltage V 3 Output Frequency Hz 4 Load Kw 5 Estimate Run Time Min 6 Load Capacity % 7 Battery Capacity % 8 Temperature ºC 9 Temperature ºF NOTE: The LCD display backlight will automatically turn off if the Select button is not pressed for more than 30 seconds. TABLE 1 GENERAL STATUS MODE TABLE 2 FUNCTIONS SETUP MODE 2)

  • FUNCTIONS SETUP MODE (Continued) FUNCTION DESCRIPTION DEFAULT SETTING Delay Time The time delay switching from battery mode to line mode. There are 9 different settings: (0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0) seconds 0 Number of Expansion Battery Packs This function defines the number of external battery packs connected to the UPS: (one - ten) 0 (no external battery packs connected)

  • Middle Atlantic Products UPS-2200R-HH, BATTERY REPLACEMENT Contact your dealer or call the number in this manual for information on battery replacement. Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Service the battery under the supervision of personnel who are knowledgeable about batteries and their precautions. Servicing of the battery can only be performed by trained personnel . WARNING: Risk of battery explosion, if battery is replaced by an incorrect type or rating. CAUTION : To reduce the ri

  • Middle Atlantic Products UPS-2200R-HH, BATTERY REPLACEMENT (Continued) 1) Remove the front panel by removing six screws then grasping it on the left hand side and pulling it away from the unit. Remove the right side of the panel to detach it from the unit. 2) Remove the retaining screws securing the cable protection cover to the UPS and remove the cover. 3) Disconnect the cable connectors from each other. REMOVE FRONT PANEL DISCONNECT CABLE CONNECTORS Page 21 REMOVE CABLE PROTECTION COVER CAUTION: The battery is heavy, use caution when removing

  • BATTERY REPLACEMENT (Continued) 4) Remove three battery retaining screws (2 on left side, and 1 on the right side) and pull the battery out using the handle. 5) Insert replacement battery (Part No. UPS-RBP) and perform steps 2 - 4 in reverse. To reinstall the faceplate, reinstall six screws. REMOVE 2 SCREWS REMOVE 1 SCREW HANDLE OPTIONAL EXTERNAL BATTE

  • Middle Atlantic Products UPS-2200R-HH, Problem Possible Cause Solution Outlets do not provide power to equipment. The UPS does not perform the expected runtime. The UPS will not turn on. Middle Atlantic Power Manager software is inactive 1. Circuit breaker has tripped due to an overload. 2. Batteries are discharged 3. Unit has been damaged by a surge or spike. 4. Non critical outlets have turned off automatically due to an overload. 1. Turn the UPS off and unplug at least one piece of equipment. Wait 10 seconds, reset the circuit breaker, and then turn on the UPS. 2. Recharge the unit for at least 4 hours. 3. Contact Middle Atlantic Products at

  • Middle Atlantic Products UPS-2200R-HH, TROUBLESHOOTING NETWORK INTERFACE CARD Page 24 Unable to configure the UPS Network Interface Card by method 1 or method 2. Unable to ping the UPS Network Interface Card. Forgotten user name and password. 1. Check the LED status, the normal condition is both yellow and green led is on. If green LED is off: Check if the UPS Network Interface Card is properly seated in the UPS and the UPS power is on. If yellow LED is off: Check if the network connection is valid. 2. Check if the operated PC is on the same physical network as UPS Network Interface Card is

  • TECHNICAL SPECIFICATIONS Capacity (VA) Capacity (Watts) Input Input Voltage Range Input Frequency Range Output On Battery Output Voltage On Battery Output Frequency Transfer Time (Typical) Overload Protection Surge Protection and Filtering Lighting/Surge Protection Internet Ready (DSL/ Phone/Fax/Modem Protection) Physical Output Receptacles Hardwired Output Dimensions: in. (cm) Weight: Lb

  • Middle Atlantic Products UPS-2200R-HH, TECHNICAL SPECIFICATIONS CONTINUED Warning Diagnostics Indicators Audible Alarms Power On, Wiring Fault, LCD Display (Using Battery, AVR, Load Level, Battery Level) On Battery, Low Battery, Overload Environmental Operating Temperature Operating Relative Humidity 32º F to 104º F (0º C to 40º C) 0 to 95% Non-Condensing Communication Power Manager Software ™ Windows 98/ME/NT/2000/XP/Vista/7 Management Self-Test Manual Self-Test Auto-Charger/Auto-Restart Yes COM Interface True RS232 x1 + Analog I/O x 1 Built-in USB Interface Yes Page 26

  • Middle Atlantic Products UPS-2200R-HH, Page 27 WARRANTY Middle Atlantic Products, Inc. (the "Company") warrants the UPS-2200R-HH Uninterruptible Power Supply product to be free from defects in material or workmanship under normal use and conditions for a period of (3) three years from date of shipment by the Company, with the following exception: the internal battery is covered for (2) two years. The Company's entire liability to the purchaser, and the purchaser's (or any other party's) sole and exclusive remedy, under this warranty shall be limited, at the Company's option, to either (a) return of and refund of the price paid for, or (b) repair or repla

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 USR IOT USR-W610 Operation & user’s manual usr-iot/usr-w610-987.pdf 04 Jan 2023 18
2 Planar ND1750 Operation & user’s manual planar/nd1750-Q2Y.pdf 24 Jun 2022 16
3 Philips DA1000 Manuale per l'utente philips/da1000-Q9L.pdf 26 Nov 2022 16 1.06 Mb
4 Casio 5130 (OC) Operation manual casio/5130-oc-22D.pdf 27 Oct 2022 4
5 AllTrade #540025 Instruction manual alltrade/540025-JEP.pdf 02 Jan 2023 19 4.65 Mb
6 Focal Access 570 CA1 Specification sheet focal/access-570-ca1-58A.pdf 16 Jul 2023 1 0.21 Mb

Similar Resources:

  • Tripp Lite

    SmartPro Rackmount SMX500RT1U

    (5 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SMX500RT1USmartPro .5kVA Line Interactive UPS, SNMPWEBCARD option, 1U Rack/Tower, USB, Serial, EPO, 230V Highlights500VA line interactive 1U rack/tower UPS230V nominal output during brownouts to 187V and overvoltages to 252VUSB, RS232, EPO a …
  • Tripp Lite

    PDUV30-36

    (16 pages)
    1Metered Rack PDUModels: PDUMV30, PDUMV30HV, PDUV30HV, PDUV30-36, PDUMV20HV, PDUMV20HVL6, PDUMV20HV-36, PDUV20HVL6-72(Series Numbers: AGIB6672, AGPD6673, AGPD6674)Important Safety Instructions 2Important Warnings 2Installation 3Features 3Warranty & Product Registration 4Español 5Français 9Русский 13Owner’s Manual1111 W. 35th Street, Chica …
  • CyberPower

    BR700ELCD

    (2 pages)
    Quick Start Guide BR700ELCD / BR1000ELCD / BR1200ELCD EN / FR / DE / IT / ES / RO / HR / GR / HU K01-C000220-03 SAFETY / SÉCURITÉ / SICHERHEITSHINWEISE / SICUREZZA / SEGURIDAD / MASURI DE SIGURANTA / SIGURNOSNE / ΑΣΦΑΛΕΙΑ / BIZTONSÁGI ELŐÍRÁSOK CAUTION! DO NOT USE WITH MEDICAL OR LIFE SUPPORT EQUIPMENT! CAUTION! To prevent the risk of fir …
  • Cleanline

    L Series

    (2 pages)
    Software Download & Installation1. Go to the website http://www.powermatic.co.th2. Click ViewPower software icon and then choose your required OS to download the software. 3. Follow the on-screen instructions to install the software.4. When your computer restarts, the monitoring software will appear as an orange plug icon located in the system tra …
  • Block

    PC-0524-400-0

    (23 pages)
    Manual Uninterruptible Power Supply Charge and control unit PC-0524-400-0 BLOCK Transformatoren-Elektronik GmbH Max-Planck-Strasse 36–46 • 27283 Verden • Germany Phone +49 4231 678-0 • Fax +49 4231 678-177 [email protected] • block.eu …
  • Tripp Lite

    SU8000RT3U

    (7 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SU8000RT3USmartOnline 8kVA On-Line Double-Conversion UPS, 6U Rack/Tower, 200-240V NEMA outlets Highlights8kVA / 8000VA / 7200W on-line double-conversion UPS; 0.9 power factor200/208/220/230/240V 50/60Hz output; Economy mode option6U Rack/Tow …

Comments, Questions and Opinions: