Manualios.com

TriMark e-Ask e-FOB System Instructions

TriMark e-Ask e-FOB Manual Online:

3.4, 1863 votes
TriMark e-Ask e-FOB User Manual
TriMark e-Ask e-FOB User Guide
TriMark e-Ask e-FOB Online Manual

Text of TriMark e-Ask e-FOB User Guide:

  • TriMark e-Ask e-FOB, Table of Contents Introduction .................................................................................. 1 e-FOB Operation and Features ................................................... 2 Teaching Additional Fob Transmitters ...................................... 3 Smart Led .................................................................................. 4 Dip Switch Setting Assignment .................................................. 4 DIP Switch #1: Sustained Output ...................

  • TriMark e-Ask e-FOB, Introduction This manual provides the necessary information for the installation and use of TriMark’s e-FOB transmitter/receiver system. Basic functions of the system include:  Locking and unlocking doors  Light activation  Panic mode  Auxiliary functions based upon configuration (see page 4) The e-FOB system includes:  Receiver  2 FOB transmitters  14-pin wire harness  10-pin wire harness  4-pin wire harness  Smart LED  Push button switch  Starter kill wires The receiver and FOB transmitters are

  • e-FOB Operation and Features Notes:  While the engine is running only the entry unlock function of the e-FOB remains activated —other functions are deactivated.  For information on changing the default configuration, see DIP Switch Setting Assignment on page 4. Lock button Horn button * button Unlock button 2 Button Function Lock Locks all entry door

  • TriMark e-Ask e-FOB, Teaching Additional FOB Transmitters 1. Plug the smart LED into CN4 and the push button into CN5. 2. Apply +12 V to the yellow wire. 3. Press and hold the push button switch until the LED assembly turns on and then off (about 5 seconds). 4. Press the Lock button of each new FOB transmitter once (do not hold button). Up to 4 transmitters may be programmed at one time. 5. Disconnect the yellow wire and verify proper e-FOB transmitter and receiver reception. Notes:  If you place the system in learn mode and teach nothing, the system will exit in 10 seconds.  If the 4-transmitter limit is

  • TriMark e-Ask e-FOB, Switch #1 Lower Buttons - Sustained Output ON = see Switch #2 OFF = Sustained Output #2 Lower Left Button Output ON = Panic Mode OFF = Horn Pulse #3 Automatic Lock/Unlock ON = Enabled OFF = Disabled #4 Parking Light Supervision ON = Enabled OFF = Disabled #5 Staggered Lock/Unlock ON = Not staggered OFF = Staggered DIP Switch Settings Smart LED: The smart LED indicates system status:  Slow flash = Armed  Off = Disarmed  Solid on = Valet mode  Fast

  • TriMark e-Ask e-FOB, DIP Switch #3: Automatic Lock/Unlock  DIP switch #3 ON: the auto-locking feature is activated. All doors are locked 5-seconds after engine start. Doors unlock when the engine is turned off. THIS FEATURE IS CANCELED AUTOMATICALLY if the door is open or opened when the engine is started. This protects against accidental locking of keys in the vehicle.  DIP switch #3 OFF: Automatic lock/unlock feature is disabled. DIP Switch #4: Parking Light Supervision  DIP switch #4 ON: the parking and headlights are actuated with the

  • TriMark e-Ask e-FOB, Vehicle Alarm (when installed) The alarm is armed when the doors are locked. If any outside door is opened while the alarm is set, the horn, siren, and lights flash for 1 minute. Press the Unlock button to deactivate the alarm. Valet Mode (requires hook-up to ignition) Some situations, such as valet parking, or leaving the vehicle at the dealer, require that alarm features be suspended. Placing the alarm in “Valet Mode” suspends audible features. In-Vehicle Valet Activation 1. Turn the ignition to the ON po

  • 7 Starter Kill Feature Wire the starter through CN2 and CN3. Once installed this feature defeats the starter if the alarm is set off so that the vehicle cannot be stolen. DO NOT BYPASS THE IGNITION OR FUEL PUMP. In case of an emergency, the starter kill feature can be bypassed with the emergency override. Emergency Override To disarm the alarm in case of

  • TriMark e-Ask e-FOB, This product has been manufactured with methods to ensure high quality and to meet the high expectations of our customers. TriMark warrants this product to be free from workmanship defects and will remedy issues per TriMark's warranty policy. Remote transmitter FOBs, batteries, and other equipment subject to normal wear and deterioration may need to be replaced periodically by dealer and/or end user and are not covered by this warranty. TriMark will not be liable for indirect, special, incidental or consequential dam- ages. Problem Description Possible Solution Button p

  • TriMark e-Ask e-FOB, Appendix: Installation and Mounting e-FOB System Contact TriMark for specific mounting details, such as drawings, placement suggestions, mounting hardware, etc. General Mounting Guidelines: The RF receiver should be placed in an interior location that does not shield RF signals. You may need to try multiple locations to optimize reception. The antennae must be left fully extended and exposed. Minimize shielding from metal enclosures. Wiring color code tables and diagrams The following tables and diagrams are provided to show c

  • TriMark e-Ask e-FOB, WIRE COLORS 14-PIN HARNESS PURPLE / WHITE AUX. * Button INPUT/OUTPUT. BUILT-IN RELAY, 12A. 1 PURPLE / WHITE A FUSE IS RECOMMENDED 2 WHITE / GREEN LOCK OUTPUT (N/C RELAY 30) 3 WHITE / BLACK LOCK INPUT (N/C RELAY 87A) 4 YELLOW CONNECT TO TRUE IGNITION 5 BLACK CONNECT TO A CLEAN GROUND. SOLID CONNECTION IS A MUST 6 SIREN (+) OUTPUT. UP TO 2 A CAPACITY. BROWN SHORT PROTECTED 7 CONNECT TO A STRONG POWER SOURCE. USE A FUSE RED AT THE CONNECTION POINT. 8 BLUE / WHITE UN

  • TriMark e-Ask e-FOB, WIRE COLORS 10-PIN HARNESS ORANGE ARMED OUTPUT (-) 500MA. 1 WHITE / BROWN AUX. CHANNEL #2 FOR LONG UNLOCK BUTTON PRESS OUTPUT, (-) 500MA 2 BROWN / WHITE HORN HONK OUTPUT, (-) 500MA 3 WHITE / YELLOW 2ND UNLOCK (-) 500MA. 4 GRAY LIGHTS OUTPUT. (-) 500MA 5 PURPLE / GREEN UNASSIGNED INPUT 6 WHITE / BLUE STAGGERED LOCKING 7 BLUE (-) SECONDARY TRIGGER INPUT. (TRUNK, HOOD) 8 GREEN (-) DOOR TRIGGER INPUT 9 PURPLE (+) DOOR TRIGGER INPUT 10 WIRE COLORS 4-PIN HARNESS WHITE / RED UNLOCK INPUT FROM INTERIOR DOOR SWITCH (GND INPUT) 2 WHITE / GREEN LOCK INPUT FROM INTERIOR DOOR SWITCH (GND INPUT) 4 0.250 MALE CONNECTORS CN2 & CN3

Related Products and Documents (Car Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sharp EL-371S Operation manual sharp/el-371s-728.pdf 24 Sep 2023 2 0.19 Mb
2 Sharp CD-G10000 Operation manual sharp/cd-g10000-22N.pdf 22 Jul 2022 47 3.72 Mb
3 Angelcare AC401 Owner's manual angelcare/ac401-9US.pdf 10 Mar 2023 44 5.8 Mb
4 ColdTech 32SLC-L3-JC Specifications coldtech/32slc-l3-jc-XZ9.pdf 10 Sep 2022 2 3.27 Mb
5 Zodiac PF 6M-8M-11M-13M-15M Operation & user’s manual zodiac/pf-6m-8m-11m-13m-15m-AKN.pdf 09 Nov 2022 8 0.97 Mb
6 Hearth and Home Technologies Heatilator EL36 Series Owner's manual hearth-and-home-technologies/heatilator-el36-series-HH7.pdf 18 Oct 2022 52 3.68 Mb

Similar Resources:

  • Autostart

    AS-6450VTW-FM

    (4 pages)
    Ì É Ñ ó É ß Ç Ô Û Ü ß Ë Ì Ñ Ó ß Ì × Ý ñ Ó ß Ò Ë ß Ô ÌÎßÒÍÓ×ÍÍ×ÑÒ ÎÛÓÑÌÛ ÍÌßÎÌÛÎ É×ÌØ ÚËÔÔ ßÔßÎÓ ÍÇÍÌÛÓ ßÒÜ Ê × Î Ì Ë ß Ô Ì ß Ý Ø Í Ç Í Ì Û Óø ß Í Ð Î Ù ó ï ð ð ð Ý Ñ Ó Ð ß Ì × Þ Ô Û ÷ Ò±¬·½» ̸» ³¿²«º¿½¬«®»® � …
  • Clifford

    5806X

    (53 pages)
    OWNER’S GUIDEMODEL5806X© 2013 Directed, All rights reserved. The company behind Clifford® Auto Security Systems is Directed.Since its inception, Directed has had one purpose, to provide consumers with the finest vehicle security and accessories available. The recipient of nearly 100 pat-ents and Innovations Awards in the field of advanced electronic …
  • Autopage

    RF-1050KE

    (1 pages)
    Models: RF-1050KE / RF-1055KE / RST2050KE / RST2053AL / RF-305 / RF-405 / RF-405A / RF-505 TRANSMITTER PROGRAMMING In the event, you should need to add or replace a Remote Control Transmitter, it is important that you follow the instructions below. Note: Each step must be performed within 10 seconds of the previous step otherwise the system will exit …
  • Webasto

    Thermo Top E

    (31 pages)
    Water HeaterInstallation documentationIdent. No.: 1313622D_EN Fee Euro 10.00 © Webasto AGAudi A31.2 and 1.4 TFSIfrom model year 2008Left-hand drive vehicle1.2 TFSI automatic transmission not checked!Feel the driveWARNING!Hazard warning:Incorrect installation or repair of Webasto heating systems may cause a fire or result in the emission of carbon monoxide, …
  • Vapormatic

    VLC5501

    (18 pages)
    VLC5501 User manual 1VLC5501Immobiliser user manualAttention!!!Installation of this security product is additional protection foryour vehicle, but it does not protect your vehicle from allpossible thefts.User manualVersion 2.1____________________________________ …
  • Directed

    DS4+

    (38 pages)
    TL6INSTALLATION GUIDEThis product is intended for installation by a professional installer only! Attempts to install this product by a person other than a trained professional may result in severe damage to a vehicle’s electrical system and components.2017-10 -03© 2017 Directed, Vista CADS4+Designed by Installers for Installers …

Comments, Questions and Opinions: