Orion Power Systems DC1000RT Operation & User’s Manual

Orion Power Systems DC1000RT Manual Online:

3.6, 759 votes
Orion Power Systems DC1000RT User Manual
Orion Power Systems DC1000RT User Guide
Orion Power Systems DC1000RT Online Manual

Text of Orion Power Systems DC1000RT User Guide:

  • Orion Power Systems DC1000RT, Table of Contents 1. Important Safety Warning............................................................................................1 1-1. Transportation .....................................................................................................1 1-2. Preparation..........................................................................................................1 1-3. Installation ..........................................................................................................1 1-4. Operation ...............................................................................

  • Orion Power Systems DC1000RT, 1 1. Important Safety Warning Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully 1-1. Transportation  Please transport the UPS system only in the original package to protect against shock and impact. 1-2. Preparation  Condensation may occur if the UPS system is moved directly from cold to warm environment. The UPS system must be absolutely dry before being installed. Please allow at leas

  • 2 circuit. This circuit must be separated from any hazardous voltage circuits by reinforced insulation. 1-5. Maintenance, service and faults  The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified maintenance personnel.  Caution - risk of electric shock. Even after the unit is disconnected from the mains (building wi

  • Orion Power Systems DC1000RT, 3 2. Installation and setup NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Please keep the original package in a safe place for future use. 2-1 Rear panel view 1K/1.5K 2K NEMA 3K NEMA 1. Programmable outlets: connect to non-critical loads. 2. Output receptacles: connect to mission-critical loads. 3. AC input 4. Input circuit breaker 5. Emergency power off function connector (EPO) 6. USB communication port 7. RS-232 communication port 8. SN

  • Orion Power Systems DC1000RT, 4 2-2. Operating principle The operating principle of the UPS is shown as below The UPS is composed of mains input, TVSS and EMI/RFI filters, rectifier/PFC, inverter, battery charger, DC-to-DC converter, battery, dynamic bypass and UPS output. 2-3. Install the UPS For safety consideration, the UPS is shipped out from factory without connecting battery wires. Before install the UPS, please follow below steps to re-connect battery wires first. Step 1 Step 2 Step 3 Remove f

  • Orion Power Systems DC1000RT, 5 Install UPS and external battery Tower Installation Install UPS alone Step 1 Step 2 Step 3 Install UPS and external battery NOTE: When installing the UPS or battery pack with feet, please keep 70mm distance from the edge of the unit.

  • Orion Power Systems DC1000RT, 6 2-4. Setup the UPS Step 1: External battery connection (for X models only) Connect one end of external battery cable to UPS unit and the other end to battery pack. See below chart for detailed connection. Step 2: UPS input connection Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords. CAUTION: Please also install a UL-approved circuit breaker (40A) between the mains and AC input in 3K model for safety operation. Step 3: UPS output connection There two kinds of outputs: programmable outlets and general outlets. Please c

  • Orion Power Systems DC1000RT, 7 To allow for unattended UPS shutdown/start-up and status monitoring, connect the communication cable one end to the USB/RS-232 port and the other to the communication port of your PC. With the monitoring software installed, you can schedule UPS shutdown/start-up and monitor UPS status through PC. The UPS is equipped with intelligent slot perfect for either SNMP or AS400 card. When installing either SNMP or AS400 card in the UPS, it will provide advanced communication and monitoring options. PS. USB port and RS-232 port can’t work at the same time. Step 5: Network connection Network/Fax/Phone surge port Connect a singl

  • 8 2-5 Battery Replacement NOTICE: This UPS is equipped with internal batteries and user can replace the batteries without shutting down the UPS or connected loads.(hot-swappable battery design) Replacement is a safe procedure, isolated from electrical hazards. CAUTION!! Consider all warnings, cautions, and notes before replacing batteries. Note: Upon

  • Orion Power Systems DC1000RT, 9 2-6 Battery Kit Assembly (option) NOTICE: Please assemble battery kit first before installing it inside of UPS. Please select correct battery kit procedure below to assemble it. 2-battery kit Step 1: Remove adhesive tapes. Step 2: Connect all battery terminals by following below chart. Step 3: Put assembled battery packs on one side of plastic shells. Step 4: Cover the other side of plastic shell as below chart. Then, battery kit is assembly well. 3-battery kit Step 1: Remove adhesive tapes. Step 2: Connect all battery terminals by following below chart. Step 3: Put assembled battery packs on one side of plastic shells and insert one more

  • Orion Power Systems DC1000RT, 10 4-battery kit Step 1: Remove adhesive tapes. Step 2: Connect all battery terminals by following below chart. Step 3: Put assembled battery packs on one side of plastic shells. Step 4: Cover the other side of plastic shell as below chart. Then, battery kit is assembly well. 6-battery kit Step 1: Remove adhesive tapes. Step 2: Connect all battery terminals by following below chart. Step 3: Put assembled battery packs on one side of plastic shells. Step 4: Cover the other side of plastic shell as below chart. Then, battery kit is assembly well

  • 11 3. Operations 3-1. Button operation Button View Button Function ON/Mute Button  Turn on the UPS: Press and hold ON/Mute button for at least 2 seconds to turn on the UPS.  Mute the alarm: After the UPS is turned on in battery mode, press and hold this button for at least 5 seconds to disable or enable the alarm system. But it’s not applied to

  • 12 3-2. LCD Panel Display Function Remaining backup time information Indicates the remaining backup time in pie chart. Indicates the remaining backup time in numbers. H: hours, M: minute, S: second Fault information Indicates that the warning and fault occurs. Indicates the warning and fault codes, and the codes are listed in details in 3-5 section. Mute o

  • Orion Power Systems DC1000RT, 13 Indicates the Battery level by 0-25%, 26-50%, 51-75%, and 76-100%. Indicates the battery is fault. Indicates low battery level and low battery voltage. Input & Battery voltage information Indicates the input voltage or frequency or battery voltage. Vac: Input voltage, Vdc: battery voltage, Hz: input frequency 3-3. Audible Alarm Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously sounding 3-4. LCD display wordings index Abbreviation Display content Meaning ENA Enable DIS

  • Orion Power Systems DC1000RT, 14 3-5. UPS Setting There are three parameters to set up the UPS. Parameter 1: It’s for program alternatives. Refer to below table. Parameter 2 and parameter 3 are the setting options or values for each program.  01: Output voltage setting Interface Setting For 200/208/220/230/240 VAC models, you may choose the following output voltage: 200: presents output voltage is 200Vac 208: presents output voltage is 208Vac 220: presents output voltage is 220Vac 230: presents output voltage is 230Vac 240: presents output voltage is 240Vac For 100/110/115/120VAC models, y

  • Orion Power Systems DC1000RT, 15  04: ECO enable/disable Interface Setting ENA: ECO mode enable DIS: ECO mode disable(Default)  05: AECO enable/disable Interface Setting ENA: Advanced ECO mode enable DIS: Advanced ECO mode disable(Default)  06: Bypass mode enable/disable when UPS is off Interface Setting ENA: Bypass mode is enabled when UPS is off DIS: Bypass mode is disabled when UPS is off (Default)  07: Programmable outlets enable/disable Interface Setting ENA: Programmable outlets en

  • Orion Power Systems DC1000RT, 16  09: Acceptable input voltage range setting Interface Setting For 200/208/220/230/240 VAC models, you may choose the following selection for acceptable input voltage range: 110/300 flashing in turns: The acceptable input voltage range is from 110V to 300V. 160/260 flashing in turns: The acceptable input voltage range is from 160V to 260V. 170/270 flashing in turns: The acceptable input voltage range is from 170V to 270V. For 100/110/115/120 VAC models, you may choose the following selection for acceptable input voltage range: 55/150 flashing in turns: The accep

  • Orion Power Systems DC1000RT, 17 3-6. Operating Mode Description Operating mode Description LCD display Online mode When the input voltage is within acceptable range, UPS will provide pure and stable AC power to output. The UPS will also charge the battery at online mode. ECO mode (Efficiency Corrective Optimizer) When the input voltage is within setting range (±3%Vo max), UPS will bypass voltage to output for energy saving. PFC and INVERTER are still active at this mode. AECO mode (Advanced Efficiency Corrective Optimizer) When the input voltage is within setting range (±3%Vo max), UPS will bypass voltage to

  • Orion Power Systems DC1000RT, 18 Standby mode UPS is powered off without output power, but the battery still can be charged. Fault mode The UPS is in fault mode when no output power is supplied from the UPS and the fault icon flashes on the LCD display, although the information of UPS can be displayed in the screen. 3-7. Faults Reference Code Fault event Fault code Icon Fault event Fault code Icon Bus start fail 01 x Inverter voltage Low 13 x Bus over 02 x Inverter output short 14 Bus under 03 x Battery voltage too high 27 Bus unbalance 04 x Battery v

  • Orion Power Systems DC1000RT, 19 4. Troubleshooting If the UPS system does not operate correctly, please solve the problem by using the table below. Symptom Possible cause Remedy The AC input power is not connected well. Check if input power cord firmly connected to the mains. No indication and alarm even though the main is normal. The AC input is connected to the UPS output. Plug AC input power cord to AC input correctly. The icon is flashing and the warning code is lighting on LCD display. Alarm is sounding every second. EPO function is activated. Set the circuit in closed p

  • Orion Power Systems DC1000RT, 20 Symptom Possible cause Remedy Fault code is shown as 43 and The icon is lighting on LCD display and alarm is continuously sounding. The UPS shut down automatically because of overload at the UPS output. Remove excess loads from UPS output and restart it. Fault code is shown as 14 and the icon is lighting on LCD display. Alarm is continuously sounding. The UPS shut down automatically because short circuit occurs on the UPS output. Check output wiring and if connected devices are in short circuit status. Fault code is shown as 01, 02,

  • Orion Power Systems DC1000RT, 21 5. Storage and Maintenance Operation The UPS system contains no user-serviceable parts. If the battery service life (3~5 years at 25°C ambient temperature) has been exceeded, the batteries must be replaced. In this case, please contact your dealer. Storage Before storing, charge the UPS 5 hours. Store the UPS covered and upright in a cool, dry location. During storage, recharge the battery in accordance with the following table: Storage Temperature Recharge Frequency Charging Duration -25°C - 40°C

  • 22 MODEL DC1000RT DC1000RTX DC1500RT DC1500RTX DC2000RT DC2000RTX DC3000RT DC3000RTX VA 1000 VA 1000 VA 1500 VA 1500 VA 2000 VA 2000 VA 3000 VA 3000 VA Capacity W 800 W 800W 1200 W 1200 W 1600 W 1600 W 2400 W 2400 W INPUT Rated voltage 100VAC-120VAC Low Line Transfer 80 VAC/70 VAC/60 VAC/55 VAC ± 5 % (based on load percentage 100%-80% / 8

  • Orion Power Systems DC1000RT, 23 Battery Pack Specification Model DC1000RTXEBM DC1500RTXEBM DC2000RTXEBM DC3000RTXEBM Used with UPS Models 1K 1.5K 2K 3K Battery Type 12V 9Ah 12V 9Ah 12V 9Ah 12V 9Ah Battery Numbers 4 6 8 12 Dimensions(DxWxH) 380 x 438 x 88 480 x 438 x 88 600 x 438 x 88 Net Weight(kgs) 17.1 21.5 29 41.2 NOTE: Battery pack should be used with corresponded UPS. Orion Power Systems Service and Technical Support If you have any problems or questions with the UPS, ca

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Compaq Armada e500 Specification compaq/armada-e500-IT6.pdf 27 Sep 2022 22
2 Interfire G1-1200 Instruction manual interfire/g1-1200-9MW.pdf 10 Dec 2022 16
3 Whirlpool W1TXEMMWQ - 21CF TM Ref Glass Flat Dr WP Operation & user’s manual whirlpool/w1txemmwq-21cf-tm-ref-glass-flat-dr-wp-UY5.pdf 20 Aug 2022 24
4 Olympus PT-014 Instruction manual olympus/pt-014-652.pdf 04 Apr 2024 116
5 Patton electronics 570 Operation & user’s manual patton-electronics/570-J83.pdf 11 Feb 2024 7 0.25 Mb
6 Mitsubishi MR-385U Operating instructions manual mitsubishi/mr-385u-3K4.pdf 07 Jan 2023 11

Similar Resources:

  • Eaton

    9PX 700 RT

    (46 pages)
    ENGLISH9PX 700 RT9PX 1000 RT9PX 1000GRT9PX 1500 RT9PX 1500GRT9PX 2000 RT9PX 2200 GRT9PX 3000 RT9PX 3000 GRT9PX 3000 GLRT9PX EBM 36V RT9PX EBM 48V RT9PX EBM 72V RTInstallation and user manualCopyright © 2016 EATON All rights reserved.9PX 1-3 KVA US_EN …
  • HP

    -380467-003 - COMPAQ PRESARIO C300 C500 C700 F500 F700 LAPTOP CHARGER

    (8 pages)
    InterVideo Home TheaterQuick Start GuideWelcome to InterVideo Home Theater!InterVideo Home Theater is your complete digital entertainment solution for you to enjoy TV viewing & recording, pictures, music, video clips and DVD/ VCD playback. It has an easy-to-use interface that can be clearly viewed from your living room TV or your PC. And with the remote …
  • Omron

    BN75R

    (85 pages)
    • This manual provides important safety-related information. Thoroughly read and understand this manual before installing and using the product. • Keep this manual in a convenient location so that you can refer to it whenever necessary.• The contents of this manual are subject to change without notice.Uninterruptible Power SupplyInstruction ManualBN …
  • Intex

    KOM0229

    (28 pages)
    Uninterruptible power supplysine wave line-interactive 12 V | 230 V | 400 WKOM0229Instrukcja obsługiManual de utilizareOwner’s manualBedienungsanleitungENDEPLRO …
  • CyberPower

    649532016006

    (2 pages)
    4241 12th Ave E #400, Shakopee, MN 55379 • 1-877-297-6937 • www.CPSww.com Model #: CP600LCD UPC: 649532016006 MSRP: $89.99 The Intelligent LCD Series CP600LCD UPS is ideal power protection for individuals running a stand-alone PC in their home, or office. Real-time system vitals can be viewed from the Intelligent Crystal-Blue LCD display, and th …
  • EMC2

    AX100 Series

    (68 pages)
    1If you want to connect an AX100-Series Fibre Channel storage system - AX100SC or AX100 - directly to a Novell NetWare® server, this document is for you. You can use the procedures in this document to install configurations with a new or existing storage system that you want to connect to a new or existing server. The main topics are◆ AX100 Support Websit …

Comments, Questions and Opinions: