Manualios.com

Acer AT350 F2 Service Manual

Acer AT350 F2 Manual Online:

3.9, 1868 votes
Acer AT350 F2 User Manual
Acer AT350 F2 User Guide
Acer AT350 F2 Online Manual

Text of Acer AT350 F2 User Guide:

  • Acer AT350 F2, Appendix B Rack mount configuration 128 4 Install the mounting rails to the rack posts. (1) Align the left and right mounting rails to the front rack post mounting holes. Secure each mounting rail to the front rack post with one screw. (2) Align the left and right mounting rails to the rear rack post mounting holes. Secure each mounting rail to the rear rack post with two screws.

  • Acer AT350 F2, 3 System upgrades 60 Rank Sparing mode • In this mode, an unused spare rank is reserved on each channel. The spare rank is used to copy the contents of a failing rank on the channel to keep a system working when a rank starts to fail. The reserved rank is not able to be used before the other rank fail. • Follow the population rules described in the independent mode. Memory population for rank sparing mode Single processor configuration Notes: 1. Place DIMMs in “X” location. 2. DIMM population must

  • Acer AT350 F2, 4 System BIOS 74 Advanced menu The Advanced menu display submenu options for configuring the function of various hardware components. Select a submenu item, then press <Enter> to access the related submenu screen.

  • Acer AT350 F2, 77 Memory Configuration Parameter Description Options DDR Speed Use this feature to force a DDR3 memory module to run at a frequency other than what is specified in the specification. Auto Force DDR3-800 Force DDR3-1066 Force DDR3-1333 Force DDR3-1600 Force SPD Memory Mode When Independent is selected, all DIMMs are available to the operating system. When Mirroring is selected, the motherboard maintains two identical copies of all data in memory for data backup. When Lockstep is selected, the motherboard uses two areas of memory to run the

  • Acer AT350 F2, 161 4 Check this box to enable Virtual LAN support, and enter the VLAN ID in the field. 5 LAN Interface - This feature allows the user to select the port to be used for IPMI out-of-band communication. • The default setting is Dedicate, which will allow Smart Console to connect through the BMC Management port at all time • Select <Failover> for Smart Console to be connected from either the shared LAN port (LAN1) or BMC Management port. •Select <Shared> for Smart Console to connect through the LAN port on the board. 6 RMCP Port - This feature allows the user to select the desired RMCP (Remote Mail Checking Protocol) port based on his configura

  • Appendix C Acer Smart Console 204 14 In the Password (Optional) field, enter your user password. (Optional.) 15 To mount an image file, follow the steps below. • Click <Save>. • Click <Mount>. •To unmount an image file, follow the steps below. - Click <Unmount>. - Click <Save>.

  • Acer AT350 F2, 2 System setup 22 Power-on problems If the system fails to boot after you have applied power, check the following factors that might have caused the boot failure. • The external power cord may be loosely connected. Check the power cord connection from the power outlet to the power cord socket on the rear panel. Make sure that the cord is properly connected to the power outlet and to the power cord socket. • No power comes from the grounded power outlet. Have an electrician check your power outlet. • Loose or improperly connected internal power cables. Check the internal cable connections. If you are not confident to perform this step, ask a qualified technician to assist you

  • Acer AT350 F2, 123 • Mechanical loading Exercise care when mounting the system in a rack to avoid any accidents. • Circuit overloading Appropriate consideration should be given when connecting the supply circuit to the system to avoid any circuit overload. The system name plate rating should be used when addressing concerns about circuit overload.

  • Appendix C Acer Smart Console 180 Console Redirection - Options This feature allows you to configure Options settings for your console redirection. When you click the <Options> icon in the Menu bar, the Options menu will display as shown below. 1 Click <Options> to activate the pull-down menu to configure Options settings. 2 The options menu allows you to configure the followi

  • Acer AT350 F2, 55 Dual processors configuration Notes: 1. Place DIMMs in “X” location. 2. DIMM population must correspond to the above tables. 3. DIMM modules support 1 GB, 2 GB and 4 GB DIMMs. 4. DIMM modules support 8 GB and 16 GB DIMMs (support depends on availability). 5. Do not mix UDIMMs with RDIMMs. 6. 3-DIMM per channel configuration is only available for single/dual rank RDIMM. 7. For UDIMM and quad rank RDIMM, only a maximum of two DIMMs per channel can be supported.

  • Acer AT350 F2, 151 Configuring the Alerts Settings This feature allows the user to configure Alert settings. When you click the <Alerts> icon in the menu bar, the following screen will display: To setup an alert or to modify an alert setting, do the following. 1 Click <Alerts> to activate the alert submenu. 2 Click <Modify> to configure or modify the settings of an alert. 3 Send Test Alert is used to check if the alerts have been set and sent out correctly. 4 Click <Delete> to delete an alert.

  • 73 Main menu Parameter Description Option System Overview System BIOS Version Build Date Version of the BIOS used in your system. Date when the BIOS Setup Utility was created. Processor Speed Physical Count Displays the type of CPU detected by the BIOS. Displays the speed of the CPU detected by the BIOS. Displays the number of proces sors detected by the BIOS. System Me

  • Acer AT350 F2, 47 Installing the heatsink and fan assembly Caution! The heatsink fan assembly has a thermal interface material (TIM) on the underside. Use caution so that you do not damage the TIM. If a protective film is installed on the TIM, remove it. 1 Perform the pre-installation instructions described on page 26. 2 Remove the side panel described on page 28. 3 Lay the server on its side (components showing). 4 Do not apply any thermal grease to the heatsink or the processor die; the required amount has already been

  • Acer AT350 F2, Appendix C Acer Smart Console 144 2 FRU Reading: Click this item to display the following BMC FRU (Field Replaceable Unit) information. • FRU Device ID • Chassis Information • Board Information • Product Information

  • Acer AT350 F2, 117 RAID configuration utilities Enabling Intel Onboard SAS RAID (EFI Mode or Legacy Mode) You don’t need to change setting in BIOS Setup to enable Intel Onboard SAS RAID. Currently, AT350 F2 only supports Intel onboard SAS RAID in Legacy mode. Entering Intel onboard SAS RAID BIOS Utility (Legacy Mode) Please press CTRL-I when you see the RAID BIOS during POST. The Intel(R) Rapid Storage Technology - Option ROM will display on the screen. Entering Intel onboard SAS RAID BIOS Utility (EFI Mode) Currently, AT350 F2 only supports Intel onboard SAS RAID in Legacy mode. Loading Factory Default Setting The Intel onboard SAS RAID BIOS utility does not provide the fu

  • Appendix C Acer Smart Console 146 Sensor Readings This page displays sensor readings for the remote console. 1 From the pull-down menu, select a sensor type (category). The options include the following. • All Sensors • Temperature Sensors • Voltage Sensors • Fan Sensors • Physical Security/(Chassis Intrusion) • Power Supply • Event Logging Disabled 2 A sensor co

  • vii Operation conditions This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice: Canadian users This Class A digital apparatus complies with C

  • Acer AT350 F2, 3 System upgrades 44 Removing a 5.25-inch storage device 1 Perform the pre-installation instructions described on page 26. 2 Remove the side panel described on page 28. 3 Disconnect the power (1) and SATA (2) cables connected to the storage device. Pull out the tab (3) and pull out the device from the drive bay (4). 4 If you intend to install a new storage device, refer to the previous section. 5 Re-install the side panel and close the bezel door. 6 Observe the post-installation instructions de

  • 3 System upgrades 48 Removing and installing the processor Processor configuration guidelines This server has two LGA 2011 processor sockets for supporting Intel® E5- 2600 series series processors. The supplied processor may be upgraded. Observe the following guidelines when replacing or installing a processor. • The CPU socket must always be populated. If no p

  • Acer AT350 F2, 1 System tour 6 Front panel LED indicator status LED indicator LED color LED state Status Power state indicator Green On S0: Power On Green Blink (1 Hz with at 50% duty cycle) S1: Sleep N/A Off S4 N/A Off S5 HDD activity indicator Amber Blink HDD access N/A Off No access and No HDD fault System status Red On CPU overheat Red Fast blink (once per second) Fan failure Red Slow blink (once every 4 seconds) Power failure N/A Off Normal LAN activity indicators LAN1 LAN2 Green On LAN link/No access Green Blink LAN access N/A Off Disconnect/Idle System ID indicator N/A Off Normal Blue On System ID button pressed Blue Blinking IPMI-activated system ID

  • Acer AT350 F2, 207 6 Enter the name of the firmware you wish to upload. You can also select a firmware from the pull-down menu to upload. 7 Click <Upload Firmware> to upload the selected firmware to the host server. Warning! To properly update your firmware, do not interrupt the process until the process is completed. Once it is completed, the system will automatically reboot, and you will need to login to the server again. 8 Click <Cancel> to abort firmware uploading.

  • Acer AT350 F2, 27 5 Open the server according to the instructions on page 41. 6 Follow the ESD precautions described in the previous section when handling a server component. Post-installation instructions Perform the steps below after installing a server component. 1 See to it that all components are installed according to the described step-by-step instructions. 2 Reinstall any expansion board(s), peripheral(s), bracket(s) and system cable(s) that have previously been removed. 3 Reinstall the side panel. 4 R

  • Acer AT350 F2, 3 System upgrades 66 Installing a SAS card 1 Observe the pre-installation instructions on page 26. 2 Remove the side panel described on page 28. 3 If necessary, remove any cables that prevent access to the PCI slot. 4 Locate an empty expansion slot that is compatible with the specification of the card you intend to install. 5 Unclip the restraining latch (1) and open in the direction (2) shown below . 6 Remove the screw holding the slot in place (3). 7 Slide out the slot shield (4). Caution: Do not discard the slot cover. If the expansion card is removed in the future, the slot cover must be reinstalled to maintain proper system cooling. 8 Remove the expansion card from its pro

More Instructions:

DOWNLOAD
DOWNLOAD

Related Products and Documents (Server):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Pentax PC-550 Operating manual pentax/pc-550-UE7.pdf 10 Apr 2023 128 2.49 Mb
2 Alto-Shaam AR-7H Specification sheet alto-shaam/ar-7h-DZ5.pdf 25 Sep 2023 2 0.19 Mb
3 Philips DVP3962 Specifications philips/dvp3962-FKR.pdf 01 Apr 2023 3
4 LG LFXS2463 Owner's manual lg/lfxs2463-IF6.pdf 01 Dec 2022 45
5 Frigidaire FDR30HOLPD Factory parts catalog frigidaire/fdr30holpd-B21.pdf 25 Dec 2023 5 0.45 Mb
6 Alpha Microsystems AM-6000 Owner's manual alpha-microsystems/am-6000-IBY.pdf 08 Apr 2023 110

Similar Resources:

  • HPE

    ProLiant ML30 Gen10

    (142 pages)
    HPE ProLiant ML30 Gen10 Server User GuidePart Number: P03665-002Published: November 2019Edition: 2AbstractThis document is for the person who installs, administers, and troubleshoots servers and storage systems.Hewlett Packard Enterprise assumes you are qualified in the servicing of computer equipment and trained inrecognizing hazards in products with hazard …
  • Avocent

    ACS5004

    (2 pages)
    OVERVIEWThe Internet connectivity, Web hosting and server rental business is extremely competitive, as Strato knows all too well. The company has used aggressive pricing and innovative service features to grow its business from a fledging startup to the low-cost market leader with more than 1 million active hosted Web pages and 2 million domains.Strato' …
  • SIELCO SISTEM

    SS 8014

    (4 pages)
    SIELCO SISTEMI srl via Roma, 24 - 22070 Guanzate (CO) – Italy Tel: +39 031899671 – Fax: +39 031976966 e-mail: [email protected] website: http://www.sielcosistemi.com SS 8014SS 8014Modbus TCP/IP server4 isolated channels for RTD, Resistance and Potentiometer input User Guide – MODBUS TCP/IP protocolUser Guide – MODBUS TCP/IP protocolFirmware Ve …
  • Apple

    Drive Interconnect Board

    (11 pages)
    073-0673 Rev. C  Xserve Drive Interconnect Board Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note: Online instructions covering customer-installable parts are available at http://www.info.apple.com/installparts/. Tools Required No tool …
  • Meridian

    Soloos Control 10

    (2 pages)
    Digital OutCommsTriggerSpeakerLinkPower InLR twinstoresooloos!11 S T E P 1: Audio CoNNECTioNSYour Control 10 features a S/PDIF digital audio output. This can be connected to an S/PDIF input on your audio system, or on Meridian Digital Active loudspeakers. The Control 10 also includes a SpeakerLink output, which can be connected to Meridian Digital Active …
  • HP

    ProLiant DL980 G7

    (112 pages)
    HP ProLiant DL980 G7 Server Maintenanceand Service GuideAbstractThis document describes service procedures for the HP ProLiant DL980 G7 Server. This document is intended for experiencedservice technicians. HP assumes that you are qualified in the servicing of computer equipment, are trained in recognizinghazards in products with hazardous energy levels, and …

Comments, Questions and Opinions: