  • Siemens ESM, Functions Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 27 Notice Frames with a priority higher than 3 can have a negative effect on the redundancy functions of OSMs/ESMs so that the reconfiguration time of maximum 0.3 seconds can no longer be guaranteed and higher failover times result.

  • Siemens ESM, Interfaces, Displays and Operator Controls Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 57 Fault Mask Display Mode Note LED 3 exists only on devices with digital inputs. With the line 1 or 2 LEDs, the fault mask indicates whether the power supplies are monitored with the signaling contact. L1 or L2 LED - Lit green; in other words the corresponding power supply (line 1 or line 2) is monitored. If the power supply falls below 14 V, the signaling contact responds. - Not lit, in other words the corresponding power supply (line 1 or line 2) in not monitored

  • Siemens ESM, Installation, Commissioning, Cleaning and Maintenance Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 65 Standard Rail Mounting 1. Install the OSM/ESM on a 35 mm standard rail complying with DIN EN 50022. 2. Fit the OSM/ESM on to the rail from above and press in the bottom of the device until the catch engages. 3. Fit the electrical and optical connecting cables, the terminal block for the power supply and, if necessary, the standard cable 9/9 to the standby-sync port. Figure 27: Installing the OSM on a DIN Standard Rail

  • Siemens ESM, Copyright Siemens AG 2000/02, All rights reserved The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility or design, are reserved. Disclaimer We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are welcome. Siemens AG Automatio

  • Siemens ESM, Network Topologies with OSM/ESM Industrial Ethernet OSM/ESM 38 C79000-Z8976-C068-10 1 Fiber-optic cable (FOC) OSM ITP 62 OSM TP 62 OSM ITP 53 OSM in RM mode 1 1 1 1 OSM Figure 17: Ring with OSM Version 2 as Redundancy Manager

  • Firmware Update Industrial Ethernet OSM/ESM 76 C79000-Z8976-C068-10 6. In the Hyperterminal window select Transfer -> Send File. 7. In the next dialog window, enter the file to be downloaded and select "Xmodem" as the protocol. Start the transfer of the firmware with the "Send" button. The following dialog then appears displaying the progress of the download

  • Siemens ESM, Interfaces, Displays and Operator Controls Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 59 Full duplex Note LED 3 exists only on devices with digital inputs. Port LED - Lit green: Port operating in full duplex mode - Not lit: Port operating in half duplex mode Fault mask Note LED 3 exists only on devices with digital inputs. The fault mask indicates whether the ports and the power supplies are monitored with the signaling contact. Port LED - Lit green: Port is monitored; in other words, if the port does not have a valid connection (for exampl

  • Siemens ESM, Introduction Industrial Ethernet OSM/ESM 20 C79000-Z8976-C068-10 Properties of the OSM BC08 Ports 8 x 100 Mbps FO ports (full duplex) BFOC female connectors Maximum distance between two OSMs 3000 m (multimode graded-index fiber) Maximum ring span with 50 OSMs 150 km Digital Inputs 8 x DC 24V

  • Siemens ESM, Technical Specifications Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 83 Accessories Industrial Twisted Pair and Fiber Optic Networks Manual 6GK1970-1BA10-0AA1 Triaxial networks for Industrial Ethernet manual 6GK1970-1AA20-0AA0

  • Siemens ESM, Preface Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 3 Guide to the Manual To help you to find specific information quickly, these operating instructions include the following parts: • At the front of the operating instructions you will find a complete table of contents. • The chapters have headings in the left margin with an overview of the contents of the paragraphs in the section. • Following the appendix, you will find a Glossary in which the most important specialist terms used in the instructions are defined. • At the back of the operating instruct

  • Siemens ESM, Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 93 Index 11 A Accessories ............................................. 83 Ambient conditions, permitted................. 81 Auto polarity exchange............................ 45 Autonegotiation ....................................... 26 Autosensing............................................. 26 B Bus structure ........................................... 29 Button ...................................................... 61 C Cable lengths, permitted ......................... 80 Cascading depth ..................................... 80 Consignment ...............

  • Siemens ESM, Trademarks SIMATIC  , SIMATIC NET  , SINEC  and SIMATIC NET Networking for Industry ® are registered trademarks of Siemens AG. Third parties using for their own purposes any other names in this document which refer to trademarks might infringe upon the rights of the trademark owners. Safety Instructions Regarding your Product Before you use the product described here, read the safety instructions below thoroughly. Qualified Personnel Only qualified personnel should be allowed to install and work on this equipment . Qualified persons are defined as persons who are authorized to commission, to ground, a

  • Siemens ESM, Interfaces, Displays and Operator Controls Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 47 4.1.4 FO Ports The FO ports have BFOC/2.5(ST) female connectors. They monitor the connected cable for wire breaks complying with the IEEE 802.3 100 Base-FX standard. A break on the FO cable is always signaled by the port status display of the two attached OSMs (status LED of the port goes off). Note The FO ports operate at the fixed transmission rate of 100 Mbps. And optical link, for example, to OLM (10 Mb

  • Siemens ESM, Network Topologies with OSM/ESM Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 35 The connection between two network segments is on two separate paths. Two of the OSMs/ESMs in a ring are connected together via a connecting cable (ITP-XP standard cable 9/9 with a maximum length of 40 m) and inform each other of their operating states. One of these OSMs/ESMs is assigned the redundant function using the DIP switch setting "Stby on" (standby slave). The other OSM takes over the function of the standby master (DIP switch setting "Stby off"). Immediately following the failure of the main transmission path, the standby slave enables the redundant pat

  • Siemens ESM, Interfaces, Displays and Operator Controls Industrial Ethernet OSM/ESM 52 C79000-Z8976-C068-10 OSM/ESM in the Standby Mode: • ITP XP Standard Cable 9/9 not plugged in, short-circuited or broken • Bad standby configuration: The partner device connected via the ITP XP Standard Cable 9/9 is switched to standby. • If there is an incorrect link status on a standby port.

  • Functions Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 25 Functions 2 This chapter discusses the general functions of the OSM/ESM, in particular the properties of the switching technology. Increased Network Performance By filtering the data traffic based on the Ethernet (MAC) address of the DTEs, local data traffic remains local, only data intended for nodes in another network

  • Installation, Commissioning, Cleaning and Maintenance Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 63 5.1 Unpacking, Checking the Consignment 1. Check that the consignment includes the following components: – OSM/ESM device – Mounting brackets, screws and terminal block – One or two extra terminal blocks for OSMs/ESMs with digital inputs – CD (includes the manuals) and product in

  • Siemens ESM, Introduction Industrial Ethernet OSM/ESM C79000-Z8976-C068-10 5 7 Technical Specifications ............................................................................................. 78 8 Standards and Approvals............................................................................................ 84 9 Glossary ........................................................................................................................ 88 10 References ....................................................................................................................91 11 In

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Pinnacle Design TV36607 Parts list pinnacle-design/tv36607-NX6.pdf 06 Jan 2023 20
2 Polaroid FLU-1911S Owner's manual polaroid/flu-1911s-4R9.pdf 07 Feb 2024 28
3 Adaptive Beta-Brite Programming manual adaptive/beta-brite-D11.pdf 24 Sep 2023 50
4 Canon FTb Manual  canon/ftb-626.pdf 24 Mar 2023 46 5.79 Mb
5 Whirlpool GXU7130DXB Installation instructions and use and care manual whirlpool/gxu7130dxb-4F3.pdf 18 Jul 2022 28 1.26 Mb
6 Focus DR-HD100 Specifications focus/dr-hd100-QMQ.pdf 26 Aug 2022 2 0.2 Mb

Similar Resources:

  • D-Link

    DBT-120

    (10 pages)
    D-Link PersonalAirBluetooth USB AdapterDBT-120DBT-120DBT-120DBT-120DBT-120This product can be used with:This product can be used with:This product can be used with:This product can be used with:This product can be used with:Windows XP, Me, 2000, 98se & 98Windows XP, Me, 2000, 98se & 98Windows XP, Me, 2000, 98se & 98Windows XP, Me, 2000, 98se & …
  • Patton electronics

    2784 NAU

    (4 pages)
    he Patton 2784 Network Access Unit is a multiservice,integrated access platform that enables service providers tointegrate dial-in modem users, Internet, Extranets, CorporateIntranets or IP LANs–using Ethernet, Frame Relay, or PPP–overa single network backbone connection. Network connectivity has developed into an integral part of today’sbusiness i …
  • Tektronix

    TekConnect Probe Interface Module 80A03

    (42 pages)
    Instruction Manual80A03TekConnect Probe Interface Module071-1298-01This document applies to firmware version 1.00and above.WarningThe servicing instructions are for use by qualifiedpersonnel only. To avoid personal injury, do notperform any servicing unless you are qualified todo so. Refer to all safety summaries prior toperforming service.www.tektronix.com …
  • Telex

    XO-1

    (2 pages)
    Telex Legacy2.4 GHz Wireless IntercomThe Telex Legacy series wireless intercom is a full duplex (simultaneous talk and listen), multi-channel wireless intercom sys-tem. The Telex Legacy system offers a complete solution for 2 to 14 users, fast and easy set-up, durable beltpacks, 64 bit audio encryption and selectable professional Telex headsets. Offering a s …
  • Pulsar

    INTE

    (20 pages)
    Interface ETHERNET v.1.0 CODE: INTE EN* Edition: 3 from 05.12.2013 Supercedes edition: 2 from 19.12.2012 …
  • Gateway

    M280

    (1 pages)
    Gateway NotebookNetworking GuideMAN VIPER POSTER R1 8/05Connecting WirelesslyYour Gateway Convertible Notebook PC has built-in wireless networking. To take full advantage of your Convertible Notebook PC's wireless capabilities, you can set up a wireless network in your home or business. After your network is set up, you can wirelessly browse the Intern …

Comments, Questions and Opinions: