Text of ACT SMART CONTROLLER User Guide:

  • ACT SMART CONTROLLER, ACTSmart Operating and Installation Manual Rev 1.1 - 8 - Adding a Card Batch using the keypad: Step Keypad Entry Operation 1 16 Add Card Batch 2 Enter 10-digit card number 10-digit First Card number with leading zeros. Eg. Card 54321 enter 0000054321. 3 Enter 10-digit card number Second Card number 4 1-8, (optional)* Select each door this Card is deleted from 5 Press ✔ End Adding Card Batch Deleting a Card or Card and PIN using t

  • ACT SMART CONTROLLER, 12DC 0V N/O COMM N/C B A Aux I/O 2 Tamper 0 1 2 3 4 5 6 7 8 9 B AT CH: P R ODU CT : S E RI AL NU MB ER: 01X X-1 AC TSmart R E V1 .3 00X XX X +12V 0V A OMRON 5A 250VAC 5A 30VDC OMRON 1A 125VAC 1A 30VDC 12V DC 0V N/O COMM N/C B A Aux I/O 2 Tamper 0 1 2 3 4 5 6 7 8 9 B AT CH: P R ODU CT : S E RI AL NU MB ER: 01X X-1 AC TSmart R E V1 .3 00X XX X +12V 0V DC Power Supply Unit DC Power Supply Unit Common the 0V line of each ACTSmart to avoid Ground Loop issues. Link the AUX I/O terminal, programmed for Interlock, on each ACTSmart. ACTSmart Interlock Connections Aux I/O 1 Aux I/O 1 System Ok Fire Alarm Panel 12DC 0V N/O COMM N/C B A Aux I/O

  • ACT SMART CONTROLLER, ACTSmart Operating and Installation Manual Rev 1.1 - 4 - 30 Second Programming Guide 30 Second Programming Guide30 Second Programming Guide 30 Second Programming Guide (For typical Standalone System) 1. Enter Programming Mode. Press ✘ button followed by the programming code (default is 9999) The LED will flash amber. 2. Add a Batch of Cards Press 10, then present the first card in the batch followed by the last card in the batch. Press ✔ button to complete. 3. Set Desired Do

  • ACT SMART CONTROLLER, ACTSmart Operating and Installation Manual Rev 1.1 - 7 - Adding a Card Batch: Step Keypad Entry Operation 1 10 Add Card Batch 2 Present Card First card in Batch (lowest number card) 3 Present Card Last Card in Batch (highest number card) 4 Enter 1-8, (optional)* Select each door this batch enabled for 5 Press ✔ End programming card batch – Note: the buzzer will sound while cards are loaded into memory. Deleting a Card Batch: Step Keypad Entry Operation 1 11 Delete Card Batch 2 Present Card First card in Batch (lowest number card) 3 Present Card Last Card in Batch

  • ACT SMART CONTROLLER, ACTSmart Operating and Installation Manual Rev 1.1 - 12 - Programming a Network System Programming a Network SystemProgramming a Network System Programming a Network System Up to 8 ACTSmart devices can be connected on the network. See the ACTSmart Network Installation diagram to complete the necessary connections. Programming Door Numbers To allow some users through a door and prevent access to other users, each ACTSmart on the network must be given a door number (1-8). An ACTSmar

  • ACT SMART CONTROLLER, ACTSmart Operating and Installation Manual Rev 1.1 - 6 - ACTSmart ACTSmart ACTSmart ACTSmart Operation OperationOperation Operation The ACTSmart family consists of Proximity only, Pin and Proximity and PIN only units. Each ACTSmart can operate in standalone mode. Up to 8 ACTSmart devices can be connected on a RS485 network. The ACTSmart will support 500 Card Holders and/or 500 PIN users. Each unit is contained in a rugged polycarbonate housing, with stainless steel keys and potted electronics, allowing

  • ACT SMART CONTROLLER, Access Control Technology, Unit 8, IDA Business Park, Whitestown, Dublin 24, Ireland. TEL:353-1-4622585 FAX: 353-1-4622587 WEB: http://www.accesscontrol.ie E-MAIL: sales@ accesscontrol.ie User List User ListUser List User List Doors User Name Card Number PIN 1 2 3 4 5 6 7 8

  • ACT SMART CONTROLLER, ACTSmart Operating and Installation Manual Rev 1.1 - 3 - Installation Notes Installation NotesInstallation Notes Installation Notes • Remember to Factory Default the ACTSmart before programming • Remember to place the supplied varistor across the terminals of the door strike coil to protect the relay contacts • Don’t mount the ACTSmart Prox units near RF sources (Eg mobile phones, radio transmitters, computer monitors) or metal surfaces. • Remember that the ACTSmart PIN and Prox units de

  • ACT SMART CONTROLLER, ACTSmart Operating and Installation Manual Rev 1.1 - 9 - Programming ACTSmart Options: Step Keypad Entry Operation 1 30-41 Select Option Number 2 0 or 1 0=Off, 1= On 3 1-8, (optional)* Select each door this option is set for 4 Press ✔ End setting options Option Function Default Operation 30 Door Chime Off When set, whenever the door contact is opened, the built-in buzzer makes a chime sound and the buzzer output activates for 2 seconds 31 Silent Operatio

  • ACT SMART CONTROLLER, ACTSmart Operating and Installation Manual Rev 1.1 - 11 - Quick IO Setup: Step Keypad Entry Operation 1 53 Set Input Output Functions (0 – is default) 2 0-9 Select a code Prog Input AUX IO 1 AUX IO 2 0 Door Release Button Door Contact Door Alarm 1 Door Release Button Door Contact Buzzer 2 Door Release Button Door Contact Interlock 3 Door Release Button Card And PIN Interlock 4 Door Release Button Fire Override Interlock 5 Door Contact Follow Door Alarm 6 Door Contact Follow

  • The surface mount collar is mounted on the wall using the fixing kit supplied in the box. Place the Reader / Keypad onto the surface mount collar and clip down into place. Use the security screw supplied to attach the unit to the surface mount collar. Security screw supplied with the unit. Place the cap onto the unit and push firmly into place. - 19 - ACTSmart Moun

  • ACT SMART CONTROLLER, OMRON 5A 250VAC 5A 30VDC + OMRON 1A 125VAC 1A 30VDC Door Contact Door Release Button 12-24V DC/AC 0V N/ O COMM N/C B A Aux I/O 2 Tamper This illustration shows wiring for normally de-energised locks. If normally energised locks are required, use the N/C relay contact. 0 1 2 3 4 5 6 7 8 9 BATCH: PRODUCT : SERIAL NUMBER : 01XX- ACTSmart REV1.3 00XXX Important! Always Place Varistor Across Lock Terminals Volt-Free Tamper Contacts +12V 0V Power Supply Unit +V Sounder The Aux I/O Output is an open co

  • Note: Determine the distance between the pattress box and the mounting plate, using the spacers which are labeled 1mm to 4mm. This allows the installer to make the required spacer length 1 to 10mm by stacking each spacer together. Spacers break away from main component when required by installer for use. Standard pattress box. Mounting plate is attached to the pattress bo

  • ACT SMART CONTROLLER, Operating & Installation Instructions for Operating & Installation Instructions for Operating & Installation Instructions for Operating & Installation Instructions for ACTSmart Product Range ACTSmart Product RangeACTSmart Product Range ACTSmart Product Range

  • ACT SMART CONTROLLER, A B SHIELD Network cable is single shielded twisted pair, Belden 9501 or similar. Total cable length maximum 1.4km 12DC 0V N/O COMM N/C B A Aux I/O 2 Aux I/O 1 Tamper 0 1 2 3 4 5 6 7 8 9 B ATC H: P RODUC T: S E R IAL NUMB ER : 01X X-1 AC TS mart R E V1.3 00X XX X +12V 0V OMRON 5A 250VAC 5A 30VDC OMRON 1A 125VAC 1A 30VDC 12V DC 0V N/O COMM N/C B A Aux I/O 2 Aux I/O 1 Tamper 0 1 2 3 4 5 6 7 8 9 B ATC H: P RODUC T: S E R IAL NUMB ER : 01X X-1 AC TS mart R E V1.3 00X XX X +12V 0V DC Power Supply Unit SHIELDS B A B SH

  • ACT SMART CONTROLLER, ACTSmart Operating and Installation Manual Rev 1.1 - 2 - Contents ContentsContents Contents Installation Notes…...………………………………………………. 3 Product Specification ………………………………………………. 3 30 Second Programming Guide …………………………………….. 4 Programming Summary…………………………………………….. 5 ACTSmart Operation…...……………………………………

  • ACT SMART CONTROLLER, ACTSmart Operating and Installation Manual Rev 1.1 - 10 - Setting Programmable Input Function: Step Keypad Entry Operation 1 50 Set Input Function (5 – Door Release button is default) 2 0-5 Select I/O Function Code (see below for explanation of codes) 3 1-8 (optional)* Select each door this function is valid for 4 Press ✔ End programming Input Function Setting AUX I/O 1 Function: Step Keypad Entry Operation 1 51 Set AUX I/O 1 Function (0 - Door Contact is default) 2 0-9 Select I/O Fun

  • ACT SMART CONTROLLER, ACTSmart Operating and Installation Manual Rev 1.1 - 5 - Programming Summary Programming SummaryProgramming Summary Programming Summary Code Function Default 10 Add Card Batch 11 Delete Card Batch 12 Add PIN 13 Delete PIN 14 Add Card and PIN 15 Delete Card and PIN 16 Add Card Batch using keypad 17 Delete Card and PIN using keypad 20 Set Door Relay Time 5 seconds 21 Set Door Ajar Time 30 seconds 22 Set Guest Buzzer Time 2 seconds 23 Change Programming Code 9999 24 Change

  • ACTSmart Operating and Installation Manual Rev 1.1 - 13 - Find Door Number: Step Keypad Entry Operation 1 61 Find Door Numbers 2 1-8 Enter the door number to be found. The ACTSmart assigned the door number starts to beep. 3 Press a key or present a card To stop the ACTSmart beeping Find All Door Numbers: Step Keyp

Related Products and Documents (Cooktop):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Weslo Pursuit S 25 Exercise Bike Manual  weslo/pursuit-s-25-exercise-bike-416.pdf 20 Jan 2024 16 0.82 Mb
2 Uniden 248 Owner's manual uniden/248-IE2.pdf 19 Sep 2023 56 1.16 Mb
3 Mazda MAZDA3 2011 Specification mazda/mazda3-2011-5BE.pdf 14 Jul 2023 8
4 Melissa 640-127 Specifications melissa/640-127-428.pdf 27 Jan 2024 1
5 Vision VZN-441H Owner's manual vision/vzn-441h-625.pdf 28 Jul 2022 24
6 Nikon Coolpix L12 - Digital Camera - Compact Manual del usuario nikon/coolpix-l12-digital-camera-compact-ZQV.pdf 21 Sep 2023 144

Similar Resources:

  • GE

    Cafe

    (144 pages)
    RefrigeratorsBottom Freezer239D3389P011 Pub No. 49-60741 07-15 GEWrite the model and serial numbers here:Model # ____________________Serial # ____________________Find these numbers on a label on the left side, near the middle of the refrigerator compartment.GE Café™ models Owner’s Manual and Installation InstructionsModels that start with CFE are …
  • Frigidaire

    FGC36S7FCA

    (28 pages)
    GAS COOKTOP INSTALLATION INSTRUCTIONS(Models with Optional Electric Built-In Oven Combination)1INSTALLATION AND SERVICE MUST BE PERFORMED BYA QUALIFIED INSTALLER.IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.If the information in this manual is not followed exactly, a fire or explosion may res …
  • Gaggenau

    VG 231 AU

    (4 pages)
    9000576976 950910 VG 231 AU Ú Installation instructionsPLQPLQ[ ¡¡PLQPLQPLQPLQPLQ )ORRUPD[PPPPPP*DVFRQQHFWLRQ� …
  • Frigidaire

    FEF312BSE

    (2 pages)
    NOTICE - This service data sheet is intended for use bypersons having electrical and mechanical training and alevel of knowledge of these subjects generallyconsidered acceptable in the appliance repair trade.The manufacturer cannot be responsible, nor assumeany liability for injury or damage of any kind arisingfrom the use of this data sheet.SAFE SERVICING P …
  • Kenmore

    253.7041 series

    (35 pages)
    French Door Bottom FreezerLa Porte-fenêtre Congélateur InférieurUse & Care GuideManual de Uso y CuidadoGuide d’utilisation et d’entretienEnglish / Español / FrançaisModels/Modelos/Modèles: 253.7041*, 7042*P/N A01649901 (1405)Sears Brands Management Corporation Homan Estates, IL 60179 U.S.A.www.kenmore.comwww.sears.comSears Canada Inc.Toronto …
  • Wolf

    ICBIM15G

    (16 pages)
    MULTI-FUNCTION COOKTOPUSE & CARE INFORMATIONModel numberICBIM15G/SThis cooktop is approved for use withNatural and Propane gases.Leave instructions with the owner.WOK use&care_mono 1.0:Intl Multi-F CT UCI 31/3/10 1:27 PM Page 1 …

Comments, Questions and Opinions: