Text of Philips SL ParBlazer 100 UV User Guide:

  • Philips SL ParBlazer 100 UV, Table 8: SL ParBlazer 100 UV RDM Parameter Status IDs Table 8: SL ParBlazer 100 UV RDM Parameter Specific PIDs RDM Parameter IDs Value Comment Implemented Get Set Allowed Allowed 0x1010POWER_STATE 0x1020PERFORM_SELFTEST 0x1030CAPTURE_PRESET 0x1021SELF_TEST_DESCRIPTION 0x1031PRESET_PLAYBACK Manufacturer Specific messages are in the range of 0x8000 - 0xFFDF. Each Manufacturer-specific Status ID shall have a unique meaning, which shall be consistent across all products having a given Manufacturer ID. See Table B-2, ANSI E1.20-2010 Status ID Message Value Da

  • Philips SL ParBlazer 100 UV, Master / Slave Operational Mode 4. Master / Slave Operational Mode The Master / Slave Operational Mode allows one SL ParBlazer 100 UV to act as the "Master" unit and all other connected units are controlled by this unit. When a unit is set to "Slave" mode, it will only listen to and follow any commands sent from a "Master" unit. Only one "Master" unit is allowed in this type of operation. Figure 10: SL ParBlazer 100 UV- Master / Slave Configuration Master Unit Slave Unit Sl

  • Philips SL ParBlazer 100 UV, WARNING! All cleaning should be performed with power completely removed from the luminaire. Never remove protective covers when luminaire is powered. Wear appropriate protective eye wear and gloves when cleaning the fixture. All service and maintenance, other than described herein, should be performed by a qualified technician or Authorized Service Center. Lint free lens tissue Lint or powder free gloves Reagent grade isopropyl alcohol* A mild soap solution If the lens is still dirty after using isopropyl alcohol, for instance if figerprints or oil is just redistributed and not

  • 5 Installation and Set Up INSTALLATION AND SET UP 1. Power Requirements The SL Pa rBlazer 100 UV Luminaire operates on AC input voltages from 100 to 240 VAC. WARN ING! The SL ParBlazer 100 UV luminaire does not have an ON/OFF switch. Always disconnect power input cable to completely remove power from the luminaire when not in use. AC Power Operation When

  • Philips SL ParBlazer 100 UV, PREFACE 1. About this Manual The document provides installation and operation instructions for the following products: Please read all instructions before installing or using this product. Retain this manual for future reference. Additional product information and descriptions may be found on the product specification sheet. Note: The SL ParBlazer 100 UV luminaire works from 100 to 240 VAC (auto-ranging). 2. Included Items Each SL ParBlazer 100 UV luminaire includes the following items: SL ParBlazer 100 UV Luminaire SL ParBlazer 100 UV Luminaire Quick Start Guide 3 About this Manual Installation & User’s ManualSL ParBlazer 100 UV SL ParBlazer 100 U

  • Philips SL ParBlazer 100 UV, SL ParBlazer 100 UV Menu Tree 11 3. SL ParBlazer 100 UV Menu Tree Figure 9: SL ParBlazer 100 UV Menu Tree Installation & User’s ManualSL ParBlazer 100 UV Temperature Firmware RDM UID 001--512 000%--100% DMX 8Bit OFF No DMX Address Manual Dimming DMX Personality Dimming Curve DMX Fail Default Setting Manual 55^oC Linear Curve Square Curve Rev1.00 0x405101020304 DMX 16Bit S_Curve PL_Curve Last Hold Manual Yes

  • Philips SL ParBlazer 100 UV, SL ParBlazer 100 UV Installation & User’s Manual Version as of: 9th Mar, 2015 Rev1.0 2015 Philips Group. All rights reserved. Showline Offices Showline - Dallas 10911 Petal Street Dallas, TX 75238 Tel: 214-647-7880 Fax: 214-647-8030 Showline - Europe Marssteden 152 Enschede 7547 TD The Netherlands Tel: +31 53 4500424 Fax: +31 53 4500425 Showline - Auckland 19-21 Kawana Street Northcote, Auckland 0627 New Zealand U.S.A Tel: +64 9 481 0100 Fax: +64 9 481 0101 Showline - Asia Unit C, 14/F, Roxy Industrial Centre No. 41-49 Kwai Cheong Road Kwai Chung, N.T., Hong Kong Tel: +852 2796 9786 Fax: +852 2798 6545 Website: www.ph

  • SL ParBlazer 100 UV Overview 4 1. SL ParBlazer 100 UV COMPONENTS Common Luminaire Components LCD Display / Menu System Front of Unit Rear of Unit UV LEDs Yoke Tilt Knob LCD Display / Menu System SL ParBlazer 100 UV OVERVIEW Safety Cable Anchor Point Figure 1: SL ParBlazer 100 UV Common Components Installation & User’s Manual DMX512/ AC Input RDM Input DMX512 / AC Output RDM Outpu

  • Philips SL ParBlazer 100 UV, OPERATION AND PROGRAMMING 9 OPERATION AND PROGRAMMING Installation & User’s ManualSL ParBlazer 100 UV 1. LCD Display and Menu System The SL PARBLAZER Luminaire’s LCD Display and Menu System provides local control for accessing the following fixture’s settings: DMX Address Manual Dimming Default Setting DMX Personality Temperature Dimming Curve Firmware DMX Fail RDM UID Note: If there are multiple luminaires in a system, changes would need to be made at each LCD Menu as desired. Upon power up, the LCD will display the main screen showing menu. The User can use “ < ” and “ ” to select then enter the d

  • Philips SL ParBlazer 100 UV, TABLE OF CONTENTS Showline Offices Inside Front Cover IMPORTANT INFORMATION Warnings and Notices Additional Resources for DMX512 Showline Limited Two-Year Warranty TABLE OF CONTENTS PREFACE About this Manual Included Items SL ParBlazer 100 UV OVERVIEW SL ParBlazer 100 UV Components INSTALLATION AND SET UP Connecting Power Connecting SL ParBlazer 100 UV to AC Power Truss / Hanging Applications Floor Mounting

  • Philips SL ParBlazer 100 UV, Connecting to the DMX512 Network 7 3. Connecting to the DMX512 Network Basic DMX512 installation consists of connecting multiple SL ParBlazer 100 UVs together (up to 32 luminaires) in "daisy-chain" fashion. A cable runs from the control console (or DMX512 control source) to the DMX connector on the first SL ParBlazer 100 UV. Another cable runs from the other DMX connector on the first unit to a DMX connector on the next SL ParBlazer 100 UV (or DMX512 device to be controlled).

  • Philips SL ParBlazer 100 UV, TECHNICAL SPECIFICATIONS 1. OPERATIONAL SPECIFICATIONS OPERATIONAL SPECIFICATIONS 40pcs High Power UV LED Array CE Marked (International models)Compliance: Die Cast aluminium with Powder Coating Housing: 17.82 lbs(8.1 kg) - Luminaire only (no mount, AC input cable or accessories)Weight: Silent Passive Cooling Cooling: 5%-95% Non condensingHumidity: -20 to 40 Degrees C ( -4 to 104 Degrees F)Ambient Temperature: 20 Degrees 17,000 mW 40 degrees 100V to 240V(+/- 10%, auto-ranging) 100 Watts(max). 50/60Hz DMX512(1990) / DMX512A (RDM) / On-Board Menu Source: Beam Angle: Light Output: Field Angle: Input Voltage: Power

  • Philips SL ParBlazer 100 UV, Additional Resources for DMX512 For more information on installing DMX512 control systems, the following publication is available for purchase from the United States Institute for Theatre Technology (USITT), "Recommended Practice for DMX512: A Guide for Users and Installers, 2nd edition" (ISBN: 9780955703522). USITT Contact Information: USITT 315 South Crouse Avenue, Suite 200 Syracuse, NY 13210-1844 Phone: 1.800.938.7488 or 1.315.463.6463 www.usitt.org Showline Limited Two-Year Warranty Showline offers a two-year limited warranty of its luminaires against defects in materials or workmanship from the date of delivery. A copy of the Showline two-year

  • Philips SL ParBlazer 100 UV, Model ID Manufacturer Model Description Product Category 0x1230 MSB of ESTA LSB of ESTA Category - Network Management Category - Status Collection Category - RDM Information RDM Parameter IDs Value Comment Implemented Get Set Allowed Allowed Unique Seq Unique Seq Unique Seq Unique Seq UID Philips Entertain. Lighting Asia SL ParBlazer 100 UV 0x2030 50H 41H 0x0001 0x0020 0x0002 0x0030 0x0011 0x0033 0x0050 0x0051 0x0010 0x0032 0x0003 0x0031 0x0015 DISC_UNIQUE_BRANCH QUEUED_MESSAGE DISC_MUTE STATUS_ME

  • Philips SL ParBlazer 100 UV, LCD Display and Menu System Operation 10 2. LCD Display and Menu System Operation The LCD Display Menu system consists of several categories. Use the Menu Buttons to access and make changes to the menu items. When the desired menu item is reached, press the desired Menu Button to display the menu options and to navigate and configure the menu options as required. To navigate and access menu settings/selections: Step 1. Make sure unit is powered and turned on. Step 2. Press the desired button (as shown in Figure 8) to access menu categories. Step 3. Use LEFT | RIGHT arrow buttons to navigate through the various options and

  • Philips SL ParBlazer 100 UV, Connecting SL ParBlazer 100 UV to AC Power 6 Connecting SL ParBlazer 100 UV to AC Power Table 2 describes how to connect power to your SL ParBlazer 100 UV. Field wiring of the SL ParBlazer 100 UV LED Luminaire is straightforward. A total of 3 wires/conductors need to be brought to the unit. The following wiring scheme is required: Figure 3: SL ParBlazer 100 UV AC Input & Output Connections Luminaire Brown Main/Line(100 to 240VAC) Blue Neutral Green/Yellow Ground (Earth) Table 2: SL ParBlazer 100 UVAC Input Connections Installation & User’s Manual Wire Color Purpose AC In

  • Philips SL ParBlazer 100 UV, Mounting Luminaire 8 4. Mounting Luminaire Truss / Hanging Applications The SL ParBlazer 100 UV is provided with the ability to hang via truss hooks, clamps, etc. (sold separately). Simply attach hook, clamp, etc. to the SL ParBlazer 100 UV yoke in the provided M12 holes. It is recommended (and may be required by local and national safety codes) to use and install a safety cable (sold separately) as illustrated in Figure 6. When hanging the fixture, be sure to leave enough space around the luminaire to allow proper, uninterrupted airflow for cooling and movement. Refer to for spacing (dimensional) requirements."Lumi

  • Philips SL ParBlazer 100 UV, DMX CONTROL DMX CONTROL This section contains information for operating the luminaire using DMX control in 8-bit mode, 16-bit mode. For Menu options and detailed information, see "LCD Display and Menu System” on page 9. Note: These tables assume a DMX start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in sequence. 1. SL ParBlazer 100 UV DMX Mapping 8-Bit Mode 16-Bit Mode Table 3 provides DMX channel mapping of a

Related Products and Documents (Flood Light):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sony DPF-P7 Operating instructions manual sony/dpf-p7-ZU9.pdf 31 Jan 2023 88 1.21 Mb
2 Kyocera Milano Operation & user’s manual kyocera/milano-8W2.pdf 26 Sep 2023 178
3 SkyGolf SkyCaddie SG1 Supplementary manual skygolf/skycaddie-sg1-N75.pdf 12 Jun 2023 1 0.58 Mb
4 Samsung LE19C350D1W Operation & user’s manual samsung/le19c350d1w-672.pdf 16 Mar 2023 36 6.28 Mb
5 Samsung RT24 Owner's instructions manual samsung/rt24-169.pdf 24 Mar 2023 20
6 Maytag MGT3800TW - 27" Gas Laundry Center Installation instructions manual maytag/mgt3800tw-27-gas-laundry-center-31R.pdf 17 Sep 2022 26

Similar Resources:

  • Sealey

    LED102

    (2 pages)
    INSTRUCTIONS FORTELESCOPIC FLOODLIGHT 20W SMD LED 230VMODEL NO: LED102Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIR …
  • American DJ

    Electra LED

    (4 pages)
    User InstructionsAmerican DJ® 4295 Charter StreetLos Angeles Ca. 90058www.americandj.comIntroduction: Thank you for purchasing the American DJ Electra LED™. To optimize the performance of this product, please read these operating instruc-tions carefully to familiarize yourself with the basic operations of this unit. The Electra LED™ is a multi-colored …
  • Ledino

    Bilk 10

    (8 pages)
    8We hereby conrm that the products are in line with the regulations – and in parti-cular with the protection requirements – of the European Union’s directive on the harmonisation of the legislation relating to electromagnetic compability (2014/30/EU), the low voltage directive 2014/35/EU, the directive for Energy-related Products 2009/125/EC and the …
  • EXTOL LIGHT

    43228

    (19 pages)
    43228 • 43229 LED reektor /CZLED reektor /SKLED reektor /HULED-Reektor /DELED Flood Light /ENPůvodní návod kpoužitíPreklad pôvodného návodu na použitieAz eredeti használati utasítás fordításaÜbersetzung der ursprünglichen BedienungsanleitungTranslation of the original user‘s manualVersion 04/2021 …
  • American DJ

    Accu Scan 250

    (20 pages)
    American DJ® 4295 Charter StreetLos Angeles CA. 90058www.americandj.com 9/04User InstructionsAmerican DJ® - www.americandj.com - Accu Scan 250™ Instruction Manual Page 2American DJ®Accu Scan 250™Table of ContentsUnpacking......................................................................3Introduction.............................................. …
  • Eaton

    Crouse-hinds series

    (110 pages)
    DOCUMENT 1218 REVISION B June 13, 2019 Instruction Manual Pro APF AGS TP312 Sign Aircraft Guidance Sign AGS-LED 312-AP1 LED Series 300mm and 400mm EATON Crouse-Hinds Series 1200 Kennedy Road Windsor, CT 06095 Copyright © 2019 Cooper Technologies Company …

Comments, Questions and Opinions: