  • Fujitsu UTP-VX60A, PART NO. 9381279005 [Original instructions] INSTALLATION MANUAL DX-kit For authorized service personnel only. UTY-VDGX UTP-VX30A UTP-VX60A UTP-VX90A TM 9381279005_IM.indb i9381279005_IM.indb i 6/30/2014 11:31:16 AM6/30/2014 11:31:16 AM

  • Fujitsu UTP-VX60A, En-1 1. SAFETY PRECAUTIONS • Be sure to read this Manual thoroughly before installation. • The warnings and precautions indicated in this Manual contain important information per- taining to your safety. Be sure to observe them. • Hand this Manual, to the customer. Request the customer to keep them on hand for future use, such as for relocating or repairing the unit. • For installation of the air handling unit (heat exchanger), refer to the installation manual for the air handling unit. WARNING This mark indicates procedures which, if improperly performed, might lead to the death or serious injury of the user. Request your dealer or a professional

  • Fujitsu UTP-VX60A, En-2 2.3. Accessories WARNING For installation purposes, be sure to use the parts supplied by the manufacturer or other prescribed parts. The use of non-prescribed parts can cause serious accidents such as the unit falling, water leakage, electric shock, or fi re. The following installation parts are furnished. Use them as required. Keep the Installation Manual in a safe place and do not discard any other accessories until the installation work has been completed. (1) Control unit Accessories Name and Shape Q’ty Application Installation Manual 1 (This book) Key 2 For the door of control unit Sealing washer 3 For mounting the control unit to the wall Waterproof specifications

  • Fujitsu UTP-VX60A, En-3 2.4. Optional parts The following options are available. When installing, refer to the installation manual of each optional part. Connectable Peripheral Devices Model Name Notes Wired Remote Controller UTY-RNKY *1, *2 Wired Remote Controller UTY-RNRY *1, *2 Wireless Remote Controller (IR receiver unit) UTY-LNHY (UTB-YWC) *2 Group Remote Controller (via network converter) UTY-CGGY (UTY-VGGXZ1) *2 Touch Panel Controller UTY-DTGY *2 Central Remote Controller UTY-DCGY *2 Network Convertor for LONWORKS® UTY-VLGX *2 BACnet® Gateway UTY-ABGX *2 System Controller UTY-APGX *2 System Controller Lite UTY-ALGX *2 Service Tool UTY-ASGX *2 Web Monitoring Tool UTY-AMGX *2 Separation Tube (For

  • Fujitsu UTP-VX60A, En-4 If children under 10 years old may approach the unit, take preventive measures so that they cannot reach the unit. Take precautions to prevent the unit from falling. (1) Install the DX-kit on a place having a suffi cient strength so that it withstands against the weight of the DX-kit. (2) Leave the space required to service the DX-kit. (3) Install the unit where connection to the outdoor unit (or RB unit) is easy. (4) Install the unit where the connection pipe can be easily installed. (5) Install the unit where noise and vibrations are not amplifi ed. (6) Take servicing, etc., into consideration and leave the spaces. (7) Do not install the unit where it wi

  • Fujitsu UTP-VX60A, En-5 4.3.2.3. Mounting Secure Fittings (If Using 1 EEV unit) (1) Use the 8 screws (accessories) to secure the secure fi ttings (accessories). Secure fi tting (Accessories) Screws M4×L10 (Accessories) Tightening torque M4 screw 0.8 to 2.8 Nm (8 to 28 kgf·cm) 4.3.2.4. Mounting Secure Fittings (If Using 2 EEV units) (1) If using 2 EEV units, stacking the 2 kits is recommended. If stacking 2 EEV units, secure using the secure fi ttings (accessories) and screws (accessories). Secure fi tting (Accessories) Screws M4×L10 (Accessories) 4.3.2.5. Installing EEV units Mount the EEV unit to the wall. Select the securing method accord

  • Fujitsu UTP-VX60A, En-6 Prohibited EEV unit orientations A AA A B BB B PROHIBITED 5. PIPE INSTALLATION CAUTION Be more careful that foreign matter (oil, water, etc.) does not enter the piping than with refrigerant R410A models. Also, when storing the piping, securely seal the openings by pinching, taping, etc. While welding the pipes, be sure to blow dry nitrogen gas through them. 5.1. Selecting the pipe material CAUTION Do not use existing pipes from another refrigeration system or refrigerant. Use pipes that have clean external and internal sides without any contamination which may cause trouble during use, such as su

  • Fujitsu UTP-VX60A, En-7 C: Inlet air thermistor/D: Outlet air thermistor Install in a location where the effects of heat sources such as heat exchangers and heat- ers, etc., are minimized as far as possible. CD Inlet air thermistor (Accessories) Outlet air thermistor (Accessories) Air outletAir inlet General indoor unit 7. ELECTRICAL WIRING WARNING Electrical work must be performed in accordance with this Manual by a person certifi ed under the national or regional regulations. Be sure to use a dedicated circuit for the unit. An insuffi cient power supply circuit or improperly performed electrical work can cause serious accidents such as electric shock or fi re. Before starting

  • En-8 CAUTION Earth (Ground) the unit. Do not connect the earth (ground) cable to a gas pipe, water pipe, lightning rod, or a telephone earth (ground) cable. Improper earthing (grounding) may cause electric shock. Do not connect power supply cables to the transmission or remote controller terminals, as this will damage the product. Never bundle the power supply cable and transmission

  • Fujitsu UTP-VX60A, En-9 A. For solid core wiring (1) To connect the electrical terminal, follow the below diagram and connect after looping it around the end of the cable. (2) Use the specifi ed cables, connect them securely, and fasten them so that there is no stress placed on the terminals. (3) Use an appropriate screwdriver to tighten the terminal screws. Do not use a screwdriver that is too small, otherwise, the screw heads may be damaged and prevent the screws from being properly tightened. (4) Do not tighten the terminal screws too much, otherwise, the screws may break. (5)

  • En-10 7.4. Connection of wiring 7.4.1. Terminal Explanation and Cable Holes • Only one cable can be passed through each cable hole. To pass multiple cables through a single cable hole, use a (fi eld supply) multi-conductor cable with more wires, and bundle multiple cables into one. • Maximum length of cable is 10 m. (recommended value, Except "P1" and "TR1") TH1

  • Fujitsu UTP-VX60A, En-11 7.4.2. Connecting the Cables CAUTION Pay attention to the following during installation. Failure to do so may cause water penetration damage. • Use the attached waterproof cable gland. • Multiple differently-shaped waterproof cable glands are attached, so make sure to use the waterproof cable gland suited to the cable hole. • Make sure to fi rmly secure the waterproof cable gland to the cable hole. • When attaching the cable gland, using a tightening torque that is less than the recommended value may cause water penetration. Using a tightening torque that is more than the recommended value may cause damage to the cable gland. (1) Connect th

  • Fujitsu UTP-VX60A, En-12 (3) Wiring the remote controller cable (device side) Y1 Y2 Y3Y1 Y2 Non-polar *1 Red White Black For 2-wire type For 3-wire type Remote controller cable Cable tie (Accessories) *1) If you connect the remote controller cable to the terminal Y3, 2-wire type remote con- troller does not work. (4) Set the DIP switch according to the type of remote controller used. Factory setting : 2WIRE DIP switch (SW1) • When using the wired remote controller, if the temperature drops below 0°C, the LCD display may become dim, the response may become slower, and the time accuracy of the clock will be lost. 7.5. External input and external

  • Fujitsu UTP-VX60A, En-13 When connected to Apply voltage terminals of multiple DX-kits with a connected unit, be sure to make a branch outside the DX-kit using a pull box, etc. as shown on below example. Power supply DC 12 to 24 V Load resistance Load resistance connected unit Input device 2 Control unitControl unit Control unit Input device 1 Terminal board P.C.B. CNA01 CNA01 CNA01 ● Dry contact terminal ([CNA02], [CNA04] ,[CNA07]) When a power supply is unnecessary at the input device you want to connect, use the Dry contact terminal ([CNA02], [CNA04], [CNA07]). C

  • Fujitsu UTP-VX60A, En-14 7.5.2. Analog external inputs Changing the voltage of the signals entered to “analog external inputs” enables you to set either the operation temperature or the required operation performance. If using this function, make the following DIP switch settings. i) Set the “Analog external inputs ON/OFF” setting to “ON”. ii) Set the control item (either the operation temperature or required operation perfor- mance). Connected unit Connected device Control unit (DX-kit) Analog signal 7.5.3. External output No. Terminal block Type-i Type-ii Status DX-kit interna

  • En-15 8. FIELD SETTING Dip switch [LED1 indicator] ON: Normal operation; Flashing: Error SET*-SW1 SET*-SW2 SET*-SW3 SET*-SW4 Dip switch Rotary switch IU AD ×10 IU AD ×1 REF AD ×1 REF AD ×10 RC AD ×1 LED1 SET2 SET3 SET4 SET1 Dip switch CAUTION Be sure to turn OFF the power before performing the fi eld setting. 8.1. Setting the address 8.1.1. Setting the

  • Fujitsu UTP-VX60A, En-16 8.2. Dip switch setting (1) Capacity settings of indoor units to be controlled The capacity of indoor units to be controlled is set. Indoor unit capacity Dip switch setting (*: factory setting) SET1-1 SET1-2 SET1-3 SET1-4 SET2-1 5.0 kW * ON OFF ON OFF OFF 6.3 kW ON OFF ON OFF ON 8.0 kW ON ON ON OFF OFF 10.0 kW OFF ON ON OFF ON 12.5 kW OFF ON OFF ON OFF 14.0 kW ON ON OFF ON OFF 20.0 kW ON OFF ON ON OFF 25.0 kW OFF ON ON ON OFF 40.0 kW ON OFF OFF ON ON 50.0 kW OFF ON OFF ON ON Not described above Settings prohibited (2) Setting digital input signal methods • Select

  • En-17 9. TEST RUN The test run function will force the outdoor unit to operate. When performing the test run, confi rm that the entire system including the external devices operates normally. (If only the outdoor unit operates, it may cause damage to the entire refrigerant system.) 9.1. Test run using Outdoor unit (PCB) • Refer to the Installation Manu

  • Fujitsu UTP-VX60A, En-18 12. OPERATIONS 12.1. Analog external inputs CAUTION • Use an insulated screwdriver to set the adjustment dial. • Do not apply voltage greater than 10V. The operation temperature and required operation performance are set by changing the voltage of the signals entered to “analog external inputs”. Compensating the analog circuit tolerance before using this function is recommended. (1) Initial settings for using the analog external inputs circuit. Set the DIP switch SET3-1 to “ON”. Set the DIP switch SET

More Instructions:

DOWNLOAD

Related Products and Documents (Control Unit):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 ASROCK K10N780SLIX3-WIFI Installation manual asrock/k10n780slix3-wifi-2WT.pdf 16 Oct 2023 224 4.75 Mb
2 Micro-Aide VDL S7?300 Operation & user’s manual micro-aide/vdl-s7-300-15P.pdf 25 Dec 2022 108
3 BLADEZ JET BIKE Owner's manual bladez/jet-bike-82B.pdf 23 Dec 2023 11
4 MTD 142-669 Operating/service instructions manual mtd/142-669-995.pdf 30 Dec 2023 20
5 Frigidaire Gallery FGET2745K Install manual frigidaire/gallery-fget2745k-YQ4.pdf 27 Sep 2022 24 1.67 Mb
6 Grizzly G0453 Owner's manual grizzly/g0453-XGU.pdf 07 Sep 2022 72 4.18 Mb

Similar Resources:

  • Hach

    8398 Series

    (68 pages)
    DOC023.98.93070Polymetron InductiveConductivity Sensors05/2015, Edition 3User ManualBedienungsanleitungManuale d'usoManuel d'utilisationManual de usuarioManual do utilizador用户手册GebruikershandleidingInstrukcja obsługiBruksanvisningKäyttäjän käsikirjaРуководство пользователя …
  • iDataLink

    Maestro RR

    (6 pages)
    NOTICE: Automotive Data Solutions Inc. (ADS) recommends having this installation performed by a certifi ed technician. Logos and trademarks used here in are the properties of their respective owners.WARNINGPressing the printer icon or “quick printing” this document will printall of the guides in this compilation.Open the Bookmarks menu and find your veh …
  • BFT

    BEBA Z-WAVE

    (2 pages)
    GUIDA VELOCEQUICK GUIDED812087 00500_02 07-03-14NODO ZWAVE PER CENTRALI ULINK COMPATIBILIZWAVE NODE FOR ULINK COMPATIBLE UNITSIl modulo BEBA Z-WAVE è ideato per funzionare solo con centrali BFT compatibili al protocollo U-LINK.IMPOSTAZIONI NECESSARIE PER IL FUNZIONAMENTOLogiche su centrali di comando Impostazioni Dip switchModo seriale 0Indiri …
  • Truth Hardware

    Marvel

    (2 pages)
    Programming of Hand Held Remote ONMotor Controller(cover removed)Learn buttonfor RFRemote110 VACConnectionDip switches(do not change)RedGreenLED light conditions:1) Green "on" = 110vac is present2) Green "blinking" = Remote signal received3) Red "on" = receiver looking for Remote4) Red "off" = Remote programing is com …
  • Chamberlain

    CLLA1

    (2 pages)
    To prevent possible SERIOUS INJURY or DEATH from electrocutionor fire, the light control is ONLY for indoor use.WARNINGCAUTIONWARNINGWARNINGATTENTIONAVERTISSEMENT AVERTISSEMENTAVERTISSEMENTRATINGResistive Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 AmpsMotor Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/3 HPInca …
  • ENFORCER

    SA-025

    (2 pages)
    The SA-025 Programmable Timer Module is suitable for a wide range of timed securityand access control operations, such as door unlock timing, siren or bell timer, VCR timer,and so on. Auto-sensing of input voltage and DIP switches for programming makeinstallation easy.Features / Specifications:• Timer can be set from 1 second to 60 minutes• Can be trigge …

Comments, Questions and Opinions: