Manualios.com

Hitachi PC-P5H Installation And Operation Manual

  • PC-P5H Remote Control
  • ma/bQguGXHLng
  • Installation And Operation Manual
  • PDF / Adobe Acrobat Reader
  • 12

Hitachi PC-P5H Manual Online:

4.5, 738 votes
Hitachi PC-P5H User Manual
Hitachi PC-P5H User Guide
Hitachi PC-P5H Online Manual

Text of Hitachi PC-P5H User Guide:

  • Hitachi PC-P5H, INSTALLATION AND OPERATION MANUAL MANUAL DE INSTALACIÓN Y FUNCIONAMIENTO INSTALLATIONS- UND BETRIEBSHANDBUCH MANUEL D’INSTALLATION ET DE FUNCTIONNEMENT MANUALE D’INSTALLAZIONE E D’USO MANUAL DE INSTALAÇÄO E DE FUNCIONAMENTO BRUGER- OG MONTERINGSVEJLEDNING INSTALLATIE- EN BEDIENINGSHANDLEIDING HANDBOK FÖR INSTALLATION OCH ANVÄNDING ÅÃ×ÅÉÑÉÄÉÏÅÃÊÁÔÁÓÔÁÓÇÓÊÁÉËÅÉÔÏÕÑÃÉÁÓ PC-P5H REMOTE CONTROLLER ENGLISHENGLISH ESPAÑOL DEUTCH FRANÇAIS FRANÇAIS ITALIANO PORTUGUESDANSK DANS

  • Hitachi PC-P5H, ESPAÑOLDEUTSCHFRANÇAISPORTUGÊSDANSKNEDERLANDSSVENSKA ITALIANOEΛΛHNIKA ENGLISH Õ DANGER – Immediate hazard which WILL result in severe injury or death. PELIGRO – Riesgos inmediatos que PRODUCIRÁN lesiones personales graves e incluso la muerte. GEFAHR – Unmittelbare Gefahrenquellen, die zu schweren Verletzungen oder zum Tod führen. DANGER – Dangers instantanés de blessures corporelles sévères ou de mort. PERICOLO – Pericolo immediato che PRODURRÀ ferite gravi o la morte. PERIGO – Problemas imediatos que IRÃO

  • Hitachi PC-P5H, SAFETY SUMMARY 1 ENGLISH 1. SAFETY SUMMARY Ö DANGER: DO NOT pour water into the remote control switch (hereafter called “controller”). This product is equipped with electrical parts. If poured, it will cause a serious electrical shock. Õ WARNING: DO NOT perform installation work and electrical wiring connection by yourself. Contact your distributor or dealer of HITACHI and ask them for installation work and electrical wiring by service person.  CAUTION: - DO NOT install the indoor unit, outdoor unit, controller and cable at such places as; - Where there is oil vapor and the oil is disper

  • Hitachi PC-P5H, 2 INSTALLATION WORK 2.3. INSTALLATION SPACE  In case of installing the controllers in vertical line, keep a distance more than 50mm between the controllers vertically. If the distance is insufficient, the front cover of the controller can not open wide enough.   2.4. INSTALLATION PROCEDURES 1. Insert the edge of the screwdriver into the groove parts at the bottom of the holding bracket, push and turn the screw driver and remove the controller from the holding bracket.  2. Connection of cable. Connect the accessory cable to the fielded cable by soldering. 3. Attach the controller to the holding bracket and connect the cable as follows. - In Case

  • Hitachi PC-P5H, ELECTRICAL WIRING 3 ENGLISH - When Using Switch Box Prepare field-supplied JIS Box (JIS C 8336-1988). ? 4. Attach the controller onto the holding bracket. At first, attach the upper side, and then the lower side. ? ?  3. ELECTRICAL WIRING 3.1. STANDARD WIRING  Õ ATTENTION: - Attach the ring core (black) (accessory) when installing the unit. - Insert the controller cable into the ring core 2 turns as shown in the left figure before connecting to the terminal board. If wiring is 0.75mm 2 it is necessary to peel the outside cover. - Fix the cable by using the band (accessory) Controller Ring core Band Controller cable M4 Screws (Field Supplie

  • Hitachi PC-P5H, 4 ELECTRICAL WIRING 3.2. ELECTRICAL WIRING FOR MULTIPLE UNITS This remote control switch can control sixteen units, as the maximum. In case of this modification, wiring connection and other works shall be performed as indicated in the following procedures. Two Remote Controls can be connected in the same unit or unit groups. The second one is Subsidiary Remote Control Switch as indicated below. Check Chapter 6 for more information. A B A B Remocon B Remocon A  Comunication cable shall be Field Supplied.  It should be use

  • CHECKING PROCEDURE 5 ENGLISH  CAUTION: - Use the twist (shield) pair cable (2x0.75mm²) as transmitting wire cable for prevention of the malfunction (The total cable length is max. 200m). When the total cable length is within 30m, other type cable (more than 0.3mm²) can be used. - Keep a distance more than 30cm between the remote control cable and the transmiss

  • Hitachi PC-P5H, 6 OPERATION 5. OPERATION  Temperature Indication  RUN LED (Red)  RUN/STOP Switch  Temperature Setting Switch  FAN SPEED (Green)  FAN SPEED Setting Switch-High  FAN SPEED Setting Switch-Medium  FAN SPEED Setting Switch-Low  To Start 1. When turning ON the indoor unit, initial process will start. ºC 2. Set at your required temperature by pressing the  switch. The set temperature is indicated on the  display. 3. Select one of the fan speed by pressing the , ,  switches. The set fan speed is indicated by the green LED . 4. Press the  Switch. The red LED  turns ON.  To Stop 1. Press the  Switch. Air Conditioning is st

  • OPTIONAL FUNCTION 7 ENGLISH 6. OPTIONAL FUNCTION  Mode Setting  ( )  Cancellation of Adjusting Set Temperature for Heating Operation  ( ) Push twice  Simultaneous operation Setting (Total Heat Exchanger model only)  ( )  Remote Control Main-Sub Setting Press the  ( )  ( ) and  ( )Switch simultaneously Settin g Mode No.  ºC Press the &

  • Hitachi PC-P5H, 8 ALARM INDICATION 7. ALARM INDICATION  The Run LED (Red) is flickering.  Indoor Unit No. and Alarm Code is indicated as shown in the right figure. (*) Model Code Model  UTOPIA $ DC Inverter  SET-FREE The other code Not Used Refrigerant Cycle Number Indoor Unit Number After 1 second ºC Model Code ( *) Alarm Code Total Number of connected units (A ~ G indicates 10 ~ 16) ºC ºC After 1 second After 1 second

Related Products and Documents (Remote Control):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 ADJ ULTRA GO PAR7X User instructions adj/ultra-go-par7x-77B.pdf 23 Aug 2022 14
2 Yamaha PM1D Overview yamaha/pm1d-8V5.pdf 11 May 2023 1 0.04 Mb
3 Shindaiwa T3410 Owner's/operator's manual shindaiwa/t3410-32G.pdf 05 Sep 2023 63
4 Benchmark ADC16 Instruction manual benchmark/adc16-I9S.pdf 18 Feb 2023 35
5 Allen-Bradley GuardShield 440L-T2KA series Installation instructions manual allen-bradley/guardshield-440l-t2ka-series-625.pdf 12 Dec 2022 20
6 Philips VR 475 Operating instructions manual philips/vr-475-267.pdf 13 Mar 2024 18

Similar Resources:

  • Cisco

    AT 6400 All Touch

    (2 pages)
    AT6400 AllTouch IR UniversalRemote ControlUser GuideWelcome to the Ultimate Control ExperienceYour new AT6400 AllTouch® Infrared (IR) Universal Remote Control (remote) is a true universal remote, functioning as four remotes in one. As one example, you can use this remote to operate your set-top, your TV, and two other devices, such as a DVD pl …
  • Samsung

    MWR-WG00JN

    (28 pages)
    Air conditionerUser manualWired remote controller MWR-WG00JN ࡙ Thank you for purchasing this Samsung Product. ࡙ Before operating this unit, please read this user manual carefully and retain it for future reference. …
  • HumanTechnik

    lisa

    (216 pages)
    1DEFunk-Kombimelder CO/TemperaturBedienungsanleitungENCombined detector CO/TemperatureUser manualFRDétecteur combiné CO/TempératureMode d’emploiNLCombinatiedetector CO/temperatuurGebruiksaanwijzingFIHäkä-/lämpötilailmaisinKäyttöohjeetSVRadiokombidetektor CO/temperaturBruksanvisning …
  • Philips

    SBC RU 760

    (25 pages)
    Universal6SBC RU 760/00Instructions for useEnglish 3Mode d'emploiFrançais 15BedienungsanleitungDeutsch 27GebruiksaanwijzingNederlands 39Instruzioni per l'usoItaliano 51Instrucciones de manejoEspañol 63Manual de utilizaçãoPortuguês 75BrugsanvisningDansk 87BruksanvisningSvenska 99BruksanvisningNorsk 111KäyttöohjeSuomi 123 …
  • Meltem

    M-WRG-FBH

    (44 pages)
    Meltem Wärmerückgewinnung GmbH & Co. KGAm Hartholz 4 · D-82239 [email protected] · www.meltem.comVENTILATION THE RIGHT WAYVENTILATION & HEAT RECOVERYUSER GUIDEHOME VENTILATION WITH HEAT RECOVERYWireless remote controlM-WRG-FBHPart no. 5302-25-01 Week 26/2020 EN …
  • Biamp

    IWA SERIES

    (4 pages)
    IWA Series Remote Control PCB Installation & Operation Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A. (503) 641-7287 http://www.biamp.com an affiliate of Rauland-Borg Corp. …

Comments, Questions and Opinions: