Hitachi PC-P5H Installation And Operation Manual
|
Hitachi PC-P5H, INSTALLATION AND OPERATION MANUAL MANUAL DE INSTALACIÓN Y FUNCIONAMIENTO INSTALLATIONS- UND BETRIEBSHANDBUCH MANUEL D’INSTALLATION ET DE FUNCTIONNEMENT MANUALE D’INSTALLAZIONE E D’USO MANUAL DE INSTALAÇÄO E DE FUNCIONAMENTO BRUGER- OG MONTERINGSVEJLEDNING INSTALLATIE- EN BEDIENINGSHANDLEIDING HANDBOK FÖR INSTALLATION OCH ANVÄNDING ÅÃ×ÅÉÑÉÄÉÏÅÃÊÁÔÁÓÔÁÓÇÓÊÁÉËÅÉÔÏÕÑÃÉÁÓ PC-P5H REMOTE CONTROLLER ENGLISHENGLISH ESPAÑOL DEUTCH FRANÇAIS FRANÇAIS ITALIANO PORTUGUESDANSK DANS
Hitachi PC-P5H, ESPAÑOLDEUTSCHFRANÇAISPORTUGÊSDANSKNEDERLANDSSVENSKA ITALIANOEΛΛHNIKA ENGLISH Õ DANGER – Immediate hazard which WILL result in severe injury or death. PELIGRO – Riesgos inmediatos que PRODUCIRÁN lesiones personales graves e incluso la muerte. GEFAHR – Unmittelbare Gefahrenquellen, die zu schweren Verletzungen oder zum Tod führen. DANGER – Dangers instantanés de blessures corporelles sévères ou de mort. PERICOLO – Pericolo immediato che PRODURRÀ ferite gravi o la morte. PERIGO – Problemas imediatos que IRÃO
Hitachi PC-P5H, SAFETY SUMMARY 1 ENGLISH 1. SAFETY SUMMARY Ö DANGER: DO NOT pour water into the remote control switch (hereafter called “controller”). This product is equipped with electrical parts. If poured, it will cause a serious electrical shock. Õ WARNING: DO NOT perform installation work and electrical wiring connection by yourself. Contact your distributor or dealer of HITACHI and ask them for installation work and electrical wiring by service person. CAUTION: - DO NOT install the indoor unit, outdoor unit, controller and cable at such places as; - Where there is oil vapor and the oil is disper
Hitachi PC-P5H, 2 INSTALLATION WORK 2.3. INSTALLATION SPACE In case of installing the controllers in vertical line, keep a distance more than 50mm between the controllers vertically. If the distance is insufficient, the front cover of the controller can not open wide enough. 2.4. INSTALLATION PROCEDURES 1. Insert the edge of the screwdriver into the groove parts at the bottom of the holding bracket, push and turn the screw driver and remove the controller from the holding bracket. 2. Connection of cable. Connect the accessory cable to the fielded cable by soldering. 3. Attach the controller to the holding bracket and connect the cable as follows. - In Case
Hitachi PC-P5H, ELECTRICAL WIRING 3 ENGLISH - When Using Switch Box Prepare field-supplied JIS Box (JIS C 8336-1988). ? 4. Attach the controller onto the holding bracket. At first, attach the upper side, and then the lower side. ? ? 3. ELECTRICAL WIRING 3.1. STANDARD WIRING Õ ATTENTION: - Attach the ring core (black) (accessory) when installing the unit. - Insert the controller cable into the ring core 2 turns as shown in the left figure before connecting to the terminal board. If wiring is 0.75mm 2 it is necessary to peel the outside cover. - Fix the cable by using the band (accessory) Controller Ring core Band Controller cable M4 Screws (Field Supplie
Hitachi PC-P5H, 4 ELECTRICAL WIRING 3.2. ELECTRICAL WIRING FOR MULTIPLE UNITS This remote control switch can control sixteen units, as the maximum. In case of this modification, wiring connection and other works shall be performed as indicated in the following procedures. Two Remote Controls can be connected in the same unit or unit groups. The second one is Subsidiary Remote Control Switch as indicated below. Check Chapter 6 for more information. A B A B Remocon B Remocon A Comunication cable shall be Field Supplied. It should be use
CHECKING PROCEDURE 5 ENGLISH CAUTION: - Use the twist (shield) pair cable (2x0.75mm²) as transmitting wire cable for prevention of the malfunction (The total cable length is max. 200m). When the total cable length is within 30m, other type cable (more than 0.3mm²) can be used. - Keep a distance more than 30cm between the remote control cable and the transmiss
Hitachi PC-P5H, 6 OPERATION 5. OPERATION Temperature Indication RUN LED (Red) RUN/STOP Switch Temperature Setting Switch FAN SPEED (Green) FAN SPEED Setting Switch-High FAN SPEED Setting Switch-Medium FAN SPEED Setting Switch-Low To Start 1. When turning ON the indoor unit, initial process will start. ºC 2. Set at your required temperature by pressing the switch. The set temperature is indicated on the display. 3. Select one of the fan speed by pressing the , , switches. The set fan speed is indicated by the green LED . 4. Press the Switch. The red LED turns ON. To Stop 1. Press the Switch. Air Conditioning is st
OPTIONAL FUNCTION 7 ENGLISH 6. OPTIONAL FUNCTION Mode Setting ( ) Cancellation of Adjusting Set Temperature for Heating Operation ( ) Push twice Simultaneous operation Setting (Total Heat Exchanger model only) ( ) Remote Control Main-Sub Setting Press the ( ) ( ) and ( )Switch simultaneously Settin g Mode No. ºC Press the &
Hitachi PC-P5H, 8 ALARM INDICATION 7. ALARM INDICATION The Run LED (Red) is flickering. Indoor Unit No. and Alarm Code is indicated as shown in the right figure. (*) Model Code Model UTOPIA $ DC Inverter SET-FREE The other code Not Used Refrigerant Cycle Number Indoor Unit Number After 1 second ºC Model Code ( *) Alarm Code Total Number of connected units (A ~ G indicates 10 ~ 16) ºC ºC After 1 second After 1 second
Hitachi RC-R008 Remote Control Operation & user’s manual
RC-R008 |
Hitachi CLE-971 Remote Control Operation & user’s manual
CLE-971 |
Hitachi RAR-3R5 Remote Control Operation & user’s manual
RAR-3R5 |
Hitachi PC-ARH Remote Control Installation and operation manual
PC-ARH |
Hitachi RAR-5E2 Remote Control Manual
RAR-5E2 |
Hitachi SPX-RCK3 Remote Control Operation & user’s manual
SPX-RCK3 |
Hitachi RAR-5J1 Remote Control Manual
RAR-5J1 |
Hitachi SPX-RCK2 Remote Control Instruction manual
SPX-RCK2 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | ADJ | ULTRA GO PAR7X | User instructions | adj/ultra-go-par7x-77B.pdf | 23 Aug 2022 | 14 | |
2 | Yamaha | PM1D | Overview | yamaha/pm1d-8V5.pdf | 11 May 2023 | 1 | 0.04 Mb |
3 | Shindaiwa | T3410 | Owner's/operator's manual | shindaiwa/t3410-32G.pdf | 05 Sep 2023 | 63 | |
4 | Benchmark | ADC16 | Instruction manual | benchmark/adc16-I9S.pdf | 18 Feb 2023 | 35 | |
5 | Allen-Bradley | GuardShield 440L-T2KA series | Installation instructions manual | allen-bradley/guardshield-440l-t2ka-series-625.pdf | 12 Dec 2022 | 20 | |
6 | Philips | VR 475 | Operating instructions manual | philips/vr-475-267.pdf | 13 Mar 2024 | 18 |
Cisco
AT6400 AllTouch IR UniversalRemote ControlUser GuideWelcome to the Ultimate Control ExperienceYour new AT6400 AllTouch® Infrared (IR) Universal Remote Control (remote) is a true universal remote, functioning as four remotes in one. As one example, you can use this remote to operate your set-top, your TV, and two other devices, such as a DVD pl …
AT 6400 All Touch(2 pages) |
Samsung
Air conditionerUser manualWired remote controller MWR-WG00JN ࡙ Thank you for purchasing this Samsung Product. ࡙ Before operating this unit, please read this user manual carefully and retain it for future reference.
…
MWR-WG00JN(28 pages) |
HumanTechnik
1DEFunk-Kombimelder CO/TemperaturBedienungsanleitungENCombined detector CO/TemperatureUser manualFRDétecteur combiné CO/TempératureMode d’emploiNLCombinatiedetector CO/temperatuurGebruiksaanwijzingFIHäkä-/lämpötilailmaisinKäyttöohjeetSVRadiokombidetektor CO/temperaturBruksanvisning
…
lisa(216 pages) |
Philips
Universal6SBC RU 760/00Instructions for useEnglish 3Mode d'emploiFrançais 15BedienungsanleitungDeutsch 27GebruiksaanwijzingNederlands 39Instruzioni per l'usoItaliano 51Instrucciones de manejoEspañol 63Manual de utilizaçãoPortuguês 75BrugsanvisningDansk 87BruksanvisningSvenska 99BruksanvisningNorsk 111KäyttöohjeSuomi 123 …
SBC RU 760(25 pages) |
Meltem
Meltem Wärmerückgewinnung GmbH & Co. KGAm Hartholz 4 · D-82239 [email protected] · www.meltem.comVENTILATION THE RIGHT WAYVENTILATION & HEAT RECOVERYUSER GUIDEHOME VENTILATION WITH HEAT RECOVERYWireless remote controlM-WRG-FBHPart no. 5302-25-01 Week 26/2020 EN
…
M-WRG-FBH(44 pages) |
Biamp
IWA Series Remote Control PCB Installation & Operation Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A. (503) 641-7287 http://www.biamp.com an affiliate of Rauland-Borg Corp.
…
IWA SERIES(4 pages) |
IEI Technology Single board computers WAFER-ULT-i1Operation & user’s manual for IEI Technology WAFER-ULT-i1 Single board computers WAFER-ULT-i1, 164 |
ASROCK Motherboard K7S8X - VERSION 3.1ASROCK K7S8X - VERSION 3.1 Motherboard Operation & user’s manual K7S8X - VERSION 3.1, 29 |
AFG Treadmill 3.0 AT SERIES#V3CP8E: 3.0 AT SERIES Treadmill Operation & user’s manual 3.0 AT SERIES, 21 |
Aprilaire Recording Equipment 81208120 Safety & installation instructions - 2FF17R 8120, 6 |
Samsung VCR DVD-V3650DVD-V3650 Manual del instrucción - GK6R67 DVD-V3650, 34 |
Bard Dehumidifier CHDMBard Dehumidifier CHDM Installation instructions manual CHDM, 14 |
Lenovo Server ThinkServerThinkServer Operation & user’s manual - M2Z7B7 ThinkServer, 210 |
JVC Projection TV HD-Z56RF7JVC Product User Guide: HD-Z56RF7 PDF Service manual - 45X936 HD-Z56RF7, 172 |
HP Storage STORAGEWORKS ALL-IN-ONE STORAGE SYSTEMManual: HP STORAGEWORKS ALL-IN-ONE STORAGE SYSTEM (5M9C12, Upd.26/11/2023) STORAGEWORKS ALL-IN-ONE STORAGE SYSTEM, 136 |
Compex Switch PS2208B-SS#89UC46 PS2208B-SS: Compex Switch Owner Documentation PS2208B-SS, 2 |
Genz Benz Speakers 3030Genz Benz Speakers Owner's manual (File: genz-benz-3030-owner-s-manual-2, 01/02/2024) 3030, 2 |
Rosemount Touch Panel 751PDF User Manual (@X75KGT), Rosemount 751 Touch Panel (Tue 09.2023) 751, 42 |