Manualios.com

HP Pavilion 501 Configuration And Administration Manual

  • Pavilion 501 Network Router
  • ma5muhRVY7uZQ
  • Configuration And Administration Manual
  • PDF / Adobe Acrobat Reader
  • 64

HP Pavilion 501 Manual Online:

3.65, 888 votes
HP Pavilion 501 User Manual
HP Pavilion 501 User Guide
HP Pavilion 501 Online Manual

Text of HP Pavilion 501 User Guide:

  • HP Pavilion 501, 12 Managing the HP 501 Configuring a management access control list You can create an access control list (ACL) that lists hosts that are authorized to access the HP 501 management tool. If this feature is disabled, anyone can access the management interface from any network client by supplying the correct user name and password. To enable the ACL feature: 1. S e l e c t Management > Management ACL to open the Management access control list configuration page. 2. Under Management ACL control, select Enabled. 3. Under Allowed IPv4 addresses and Allowed IPv6 addresses, enter an IPv4 address or IPv

  • HP Pavilion 501, LLDP configuration 41 LLDP configuration The HP 501 can use the Link-Layer Discovery Protocol (LLDP) to advertise information about itself, such as the system name, port name, and system capabilities, to devices on the wired network (LLDP information is not sent on the wireless network). This information can be useful for network management and monitoring purposes. The information contained in LLDP frames includes the device model and configured system name, the base MAC address and IPv4 address, the Ethernet port speed and duplex, and the max

  • RSSI log 51 Syslog message list The following table lists the syslog messages generated by the HP 501. The MAC address of the HP 501 is automatically added to the beginning of every syslog entry. Message Description Severity The AP startup configuration was updated successfully. Configuration settings were changed and subsequently saved. Informational Loop Protect: A loop detect

  • HP Pavilion 501, Network trace configuration 59 Wireshark is an open source tool and is available for free. It can be downloaded from www.wireshark.org. Performing a remote packet trace To perform a remote packet trace. 1. Set up the Wireshark session as described in Setting up Wireshark sessions on page 57. 2. On the HP 501 management tool, select Tools > Network trace. 3. In the Remote packet trace section, specify the Remote trace port to use as the destination for packet captures. The range is 1 to 65530 and the default port is 2002. If you change this value, you must click Save prior to starting the remote trace. 4. Click Start Remote Trace. Th

  • HP Pavilion 501, 16 Managing the HP 501 SNMPv3 configuration SNMPv3 adds security in the form of configurable encryption of data and enhanced authentication of users. You can configure security settings on a per-user basis. You can also configure a user as an SNMPv3 receiver, so that the HP 501 sends SNMP trap messages to the user. Configuring SNMPv3 users The SNMPv3 users page enables the network administrator to define multiple user IDs with different privileges and security levels. A user can be configured to have

  • HP Pavilion 501, 42 Network configuration Transmit interval The number of seconds between loop protection packets sent. The range is from 1 to 10 seconds and the the default is 3 seconds. Shutdown time The number of seconds the Ethernet interface is shut down when a loop is detected. The range is from 0 to 604800 seconds and the default is 180 seconds. If you specify a value of 0, the Ethernet interface is shut down indefinitely. Viewing loop protection statistics The following status and statistics for the loop protection feature ar

  • 24 Wireless configuration If multiple APs are detected with a stronger signal, preference is given to APs in the 5 GHz band over those in the 2.4 GHz band. The detected strength of each 5 GHz AP is increased by 10 dBm for comparison purposes only. The following examples illustrate the decision process and assume that the Mode is set to Auto. • If the HP 501 is currently co

  • HP Pavilion 501, RSSI log 49 Remote syslog Use this setting to enable or disable this feature. It is disabled by default. When enabled, messages of the selected Severity level or higher are sent to the configured syslog server. When disabled, a limited number of these messages is stored locally and can be viewed in the Events section of the System log page. Syslog server Specify the IP address or DNS name of the remote log server. Syslog port The syslog process uses logical port 514 by default. HP recommends that you keep this default. If you specify a different port number, ensure that the port number is not being used by another protocol on your network, and th

  • System log 47 6 Tools System log The system log is a comprehensive list of system messages and kernel messages, which may indicate error conditions such as dropped frames. The HP 501 stores up to 512 system error messages in volatile memory (RAM). You can view these events using the HP 501 management tool, and you can configure HP 501 to relay them as syslog messages

  • HP Pavilion 501, 46 Maintenance System information The System page enables you to download logs, settings, system tools outputs, and other information that customer support uses to diagnose problems. To download system information, select Maintenance > System. In the Show tech area, you can download a file that can be read in a text editor. The file contains configuration settings, including those that have been customized by the user. The file is named showtech.rtf by default. In the Save system information area, you can download an encrypted binary file. Although you cannot read this file, you can provide it to customer support to assist in debugging efforts. This file contains additional con

  • HP Pavilion 501, IP configuration 37 Static IPv6 address prefix length The prefix length must be an integer in the range from 0 to 128 bits. The prefix length determines the part of the IPv6 address that identifies the network to which the HP 501 is attached. Default IPv6 gateway The default gateway address for IPv6 traffic destined outside the network. IPv6 DNS nameservers You can configure up to two IPv6 DNS nameservers for resolving domain names to IP addresses. If you select Dynamic, be sure to enable DHCPv6 functionality in the field below. If you select Manual, enter up to two IPv6 addresses in the text boxes provided. Static IPv6 address status The operational statu

  • HP Pavilion 501, Email alert 53 • Alert indicates action must be taken immediately. • Critical indicates critical conditions. • Error indicates error conditions. • Warning indicates warning conditions. • Notice indicates normal but significant conditions. • Informational indicates informational messages. • Debug indicates debug-level messages. Non-urgent severity This setting determines the severity level for log messages that are considered to be non-urgent. Messages in this category are collected and sent in a digest

  • HP Pavilion 501, 36 Network configuration Static IP configuration You can manually assign an IP address to the Ethernet port. This requires that you also define the address of the default gateway and DNS server that are in use on your network. Connection type Select Static IP from the list to manually configure an IPv4 Ethernet address. Static IP address Set an address that is on the same subnet as the network to which the HP 501 will connect when installed. Respect any DHCP server-mandated static address ranges. Subnet mask Specify the mask for the IP address. Default gateway Set the IP address of

  • HP Pavilion 501, 50 Tools RSSI threshold When an RSSI value is detected that is lower than the configured RSSI threshold, the value is stored in the RSSI log and, if Syslog mode is enabled, sent to the configured Syslog server. Enter a value from –99 to –1 dBm. The default is –30 dBm. Logging interval The RSSI level is detected and logged at a regular interval. Enter the number of seconds between log entries, from 1 to 3600 seconds. Syslog mode Select Enabled to have RSSI log entries sent to the configured Syslog server when the detected RSSI value is below the threshold. Select Remote syslog configuration to display the System log

  • HP Pavilion 501, 10 Managing the HP 501 Managing HTTP SSL certificates When HTTPS access is enabled, the HP 501 must be able to present a Secure Sockets Layer (SSL) certificate to the web browser of a computer that attempts access to the management tool. The certificate assures that the browser is accessing the HP 501 with the specified IP address. It also provides information that the HP 501 and management computer use to encrypt their communication. A default certificate is present on the HP 501, based on the default device IP address 192.168.1.1. If you change the HP 501 IP address, you must update the certificate to reflect the new address; otherwise, a securi

  • HP Pavilion 501, Configuring radio settings 25 RTS threshold Specify a Request to Send (RTS) threshold value from 0 to 2347. The default is 2347 octets. To ensure that sufficient bandwidth is available to send a frame, the HP 501 can send an RTS packet to the upstream AP and await for a Clear to Send (CTS) reply. When the HP 501 receives the CTS, it sends the frame. The RTS/CTS handshake itself consumes bandwidth, so it is generally not desirable to perform the handshake prior to a large percentage of data exchanges. The RTS threshold indicates how large a frame must be in order for the HP 501

  • HP Pavilion 501, 34 Wireless configuration Viewing the MAC translation table You can select Status > MAC translation to view the MAC address/IP address associations for clients on the Ethernet network. The following fields display: Click Clear MAC table to delete all entries from the list. ACK failure count Count of ACK frames not received when expected. FCS error count Count of FCS errors detected in a received MPDU frame. Transmitted frame count Count of each successfully transmitted MSDU. WEP undecryptable count Count of encrypted frames received and the key configuration of the transmitter

  • HP Pavilion 501, Network trace configuration 57 3. Specify the following parameters: • Trace duration: The time duration in seconds for the trace (range 10 to 3600). • Max trace file size: The maximum allowed size for the trace file in KB (range 64 to 4096). If you change either of these values, you must click Save before initiating a trace. 4. Click Start Trace. The trace session runs for the specified duration. You can view the trace status in the File trace status section. Click Refresh to see updated trace time and file size

  • HP Pavilion 501, Network trace configuration 55 Network trace configuration Overview Network administrators can perform network traces to capture and analyze network traffic. Network trace operates in two modes: • Packet file trace mode: Captured packets are stored in a file on the HP 501. The HP 501 can transfer the file to a local PC or network location using HTTP or to a TFTP server. The file is formatted in pcap format and can be examined using tools such as Wireshark and OmniPeek. • Remote packet trace mode: The captured packet

  • HP Pavilion 501, 4 Software upgrade.............................................................................................................................. 45 System information.................................................................................................................................. 46 6 Tools........................................................................................................47 System log ............................................................................

  • HP Pavilion 501, Configuring radio settings 23 5 GHz bands and is capable of connecting with 802.11a/b/g/n/ac APs. This is the default setting. • IEEE 802.11a: The HP 501 can connect to an 802.11a or 802.11 a/n/ac AP as an 802.11a client. • IEEE 802.11b/g: (Compatibility mode.) The HP 501 can connect to an 802.11b/g or 802.11b/g/n AP as an 802.11b/g client. • IEEE 802.11b/g/n: (Compatibility mode.) The HP 501 can connect to an 802.11b, 802.11g, or 802.11b/g/n AP as an 802.11b/g/n client. • IEEE 802.11a/n/ac: (Compatibility mode.) The HP 501 can connect to 802.11a, 802.11n, and 802.11ac BSSIDs operating in 5 GHz frequency. • IEEE 802.11a/n: (Compatibility mode.) Only 802.11a and 802.11n BS

More Instructions:

DOWNLOAD

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 AMS Neve 88D Operation & user’s manual ams-neve/88d-37A.pdf 21 Mar 2024 85
2 Haier FCD-JTHSA80-III Operation & user’s manual haier/fcd-jthsa80-iii-A1L.pdf 12 Nov 2023 6 1.99 Mb
3 VOLTCRAFT P-600 Operating instructions manual voltcraft/p-600-5GI.pdf 12 Feb 2023 8
4 Panasonic DV-08VRE2 Installation instructions manual panasonic/dv-08vre2-G83.pdf 19 Oct 2022 8
5 One Stop Gardens 92793 Assembly & operating instructions one-stop-gardens/92793-2AA.pdf 18 Jun 2023 4
6 Apple Time Capsule Setup manual apple/time-capsule-TKY.pdf 01 Jun 2023 44 0.98 Mb

Similar Resources:

  • ORiNG

    IES-2042PA

    (42 pages)
    Industrial Lite-Managed Ethernet Switch IES-2042PA User’s Manual Version 2.0 NOV, 2011. ORing Industrial Networking Corp. Website: www.oring-networking.com E-mail: [email protected]
  • H3C

    MSR 5600

    (8 pages)
    H3C MSR 5600 Routers Comware 7 OAA Command Reference New H3C Technologies Co., Ltd. http://www.h3c.com Software version: MSR-CMW710-R0809 Document version: 6W400-20200823 …
  • King Pigeon

    N40 Series

    (9 pages)
    N40/N41 User Manual Ver 1.0 Date Issued: 2019-09-20 King Pigeon Hi-Tech. Co., Ltd. www.IOT-Solution.com Industrial Ethernet Switch …
  • Intellinet

    560535

    (12 pages)
    PoE WEB-MANAGED GIGABIT ETHERNET SWITCHWITH 2 SFP PORTSQUICK INSTALL GUIDE MODELS 560535 & 560559 INT-560535/560559-QIG-ML1-0714-0416-Port, 56053524-Port, 560559Important: Read before use. • Importante: Leer antes de usar.intellinet-network.com …
  • ADTRAN

    NetVanta 5305

    (38 pages)
    NetVanta 5305Hardware Installation Guide4200990L1 NetVanta 5305 AC Chassis4200990G1#120 NetVanta 5305 AC Chassis (RoHS Compliant) with 120 VDC Power Supply4200990G1#240 NetVanta 5305 AC Chassis (RoHS Compliant) with 240 VDC Power Supply4200995L1 NetVanta 5305 DC Chassis4200995G1 NetVanta 5305 DC Chassis (RoHS Compliant)4200990L2 NetVanta 5305 Chassis with En …
  • Asus

    GX-D1051

    (2 pages)
    • DO NOT place any device on top of the switch.• Leave enough space around the switch for adequate ventilation. Ensure that the switch is placed in a location that meets the environmental specications.Placement optionsDesktop placementPut the switch on a at and stable surface. Wall mountingMount the switch on a wall with the mounting screws.To mo …

Comments, Questions and Opinions: