  • Hyundai HY2524, CONTENTS TITLE PAGE No 1. SAFETY 3/4 2. PARTS 5/6 3. APPLICATION 7 4. INSTALLATION INSTRUCTIONS 7 5. ADDITIONAL SAFETY 7/9 6. INSTALLATION & COMISSIONING 10/11 7. TECHNICAL DATA 12 8. CLEANING & MAINTENANCE 12/13 9. DISPOSAL & RECYCLING 14 10. TROUBLESHOOTING 14 11. GENPOWER CONTACT DETAILS 15 12. DECLARATIONS of CONFORMITY 15 Page 2 Rev 2

  • 1. SAFETY. 1.1. The operator of the machine; 1.1.1. Is responsible for and has a duty of care in making sure that the compressor is operated safely and in accordance with the instructions in this user manual. 1.1.2. Should never leave it in a condition which would allow an untrained or unauth

  • Hyundai HY2524, 1.3. Electrical Safety. 1.3.1. Electricity can kill - never work on LIVE/ENERGISED equipment. 1.3.2. Identify electrical isolation method and always isolate all electrical supplies, prior to carrying out any maintenance work. 1.3.3. Prior to use and with all electrical supplies isolated check all electrical cables, plugs and connections for the following. 1.3.3.1. Are intact and have no signs of damage, to include but not limited to bare wires, chaffing, cuts and loose wiring. If there are any signs of damage, the damaged item should be taken out of service until the damage has been repaired by an electrically competent person. 1.3.4.

  • Hyundai HY2524, 2. PARTS. Picture 1. Picture 2. Picture 3. 1. Inlet air filter. 2. Compressor. 3. Oil level indicator. 4. Air tank. 5. Foot. 6. Handle. 7. ON- OFF switch 8. Pressure gauge 9. Pressure relief valve 10. Quick relase outlet. 11. Pressure regulator. 12. Tank drain valve Page 5 Rev 2

  • Hyundai HY2524, 2. PARTS Continued. Accessory kit a. Wheels x 2 b. Wheel bolts x 2 c. Oil filler cap x 1 d. Rubber foot x 1 e. Nut/Bolt for foot x 1 f. Air filter x 1 Page 6 Rev 2

  • Hyundai HY2524, 3. APPLICATION. This compressor is used to produce compressed air for pneumatic tools. 4. INSTALLATION INSTRUCTIONS. 4.1 Check the unit when it is delivered. Any damage should be immediately reported to the company. 4.2 Check the oil level before starting up. 4.3 Turn the machine on only if you are close to it. 4.4 Long air lines and long supply lines (extension) should be avoided. 4.5 Make sure that the air-intake is dry and has no dust. 4.6 Do not install the compressor in the damp or wet room. 4.7 The compressor is only allowed to wo

  • 5.1.10 Maintain your compressor with care. 5.1.10.1 Keep your compressor clean. 5.1.10.2 Follow the maintenance instructions. 5.1.10.3 Regularly check the plug and electrical supply lead. 5.1.10.4 Any damaged parts should be dealt with by a qualified person. 5.1.10.5 Inspect extension supply leads periodically and replace them if they are found damaged. 5.

  • There will be a risk of inhaling noxious fumes, mists and vapours. 5.2 Safety instructions for the operation of the compressed air and blow guns. 5.2.1 The compressor reaches a high temperature during operation. Touching it when hot can lead to burns. 5.2.2 The compressor must not be allowed to take in impurities in the air; otherwise it will l

  • Hyundai HY2524, 6. INSTALLATION & COMISSIONING. Before commissioning, all parts should be completely installed. 6.1 Installation of the wheels and foot. 6.1.1 Select parts as shown in image below (1). 6.1.2 Assemble as shown in (1)(2) by taking bolt (a) and pushing it through the centre hole of wheel (b), then put washer over protruding bolt (a). Then pass bolt through wheel frame (g), next put washers (d) and (e) over bolt, finally secure the bolt using nut (f). DO NOT overtighten the bolt, the wheel must be left

  • Hyundai HY2524, 6.2 Installation (replacing) of the air filter. 6.2.1 .1 Remove the shipping plug (Picture 4) with a screwdriver or a similar tool. Unscrew the air filter (1) with the wing nut (a) attached to the machine (Picture 5). 6.3 Filling with oil. 6.3.1 Use a screwdriver to remove the oil filler cap (Picture 6 (a)) and fill with oil into machine as shown (b) in the oil filler (Picture 7). 6.4 Electrical connections.. 6.4.1 The compressor is supplied with a power lead to three pin earthed plug. This can be connected to any power socket 230V ~ 50Hz, whic

  • Hyundai HY2524, 7. TECHNICAL DATA. 7.1 Technical data for HY2524. Model HY2524 Voltage - V 230 Number of phases 1 Frequency – Hz 50 Connection method/Cable length m 3 pin plug - BS1363A/1.3 Motor power hp/kw 2.5/1.865 Rated Speed (motor) – RPM 2800 Cubic Foot per Minute @ 6.2 Bar N/A Maximum Pressure - PSi/Bar 145/10 Cut-out Pressure - PSi/Bar 128/8.8 Cut-in Pressure - PSi/Bar 87/6 Tank Capacity - L 24 Free air delivery - CFM - L/min 5.19/147 Displacement - CFM/L/min 7.42/210 Air Outlet Machine - Male 3/8" tapered quick release euro/Hose -

  • Hyundai HY2524, 8.2 Condensation. Condensation inside the tank may contain the oil residues. Dispose of the condensation in an environmentally friendly way. DO NOT put it down the drain or onto the ground. 8.2.1 You MUST remove condensed water is daily. 8.2.2 This can be achieved by opening the condensation drain plug at the bottom of the compressor. 8.3 Safety valve. 8.3.1 The safety valve has been factory set to the maximum pressure of the tank. DO NOT attempt to adjust or remove. If there is a probl

  • Hyundai HY2524, 9. DISPOSAL & RECYLING. 9.1 Do not dispose of electric equipment together with household waste material! In observance of European Directive 2012/19/EC on waste electrical and electronic equipment and its implementation in accordance with national law, electric equipment that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility. If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. 19.2 For further information on the disp

  • Hyundai HY2524, 11. . GENPOWER CONTACT DETAILS. 11.1 1 Postal address; Genpower Limited, Isaac Way, Pembroke Dock, Pembrokeshire, SA72 4RW, UK. 11.2 2 Telephone and Fax contact numbers; Office +44 (0) 1646 687880. Fax +44 (0) 1646 686198. 11.3 3 Email contact; Techinical - [email protected] 11.4 4 Web site; www.hyundaipowerequipment.co.uk 12. DECLARATIONS of CONFORMITY. 12.1 Genpower Ltd confirms that this Hyundai product conform to the following CE directives. 2002/95/EC Restriction of Hazardous Substances 2004/108/EC EMC Directive 2006/42/EC Machinery Directive 2006/95/EC Low Voltage Di

  • Hyundai HY2524, www.hyundaipowerequipment.co.uk GENPOWER LTD Isaac Way, London Road Pembroke Dock, UNITED KINGDOM, SA72 4RW T: +44 (0) 1646 687 880 F: +44 (0) 1646 686 198 [email protected]

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Candy PVS 640 User instructions candy/pvs-640-FD5.pdf 04 Feb 2024 32 1.94 Mb
2 GAMES MICROSOFT XBOX DEAD OR ALIVE 3 Manual  games-microsoft-xbox/dead-or-alive-3-39L.pdf 23 Nov 2023 24 4.53 Mb
3 Norcold N260 Owner's manual & installation manual norcold/n260-345.pdf 04 Dec 2023 17
4 Whirlpool LMR4131A Use and care manual whirlpool/lmr4131a-6OC.pdf 30 Mar 2023 24 1.3 Mb
5 BTC DSC 3300V Operation & user’s manual btc/dsc-3300v-7Z5.pdf 01 Mar 2024 60 4.29 Mb
6 Samson Bass Enclosure VX410 Owner's manual samson/bass-enclosure-vx410-WOJ.pdf 21 Mar 2024 4 2.26 Mb

Similar Resources:

  • Vixen Air

    VXF1GP2R

    (2 pages)
    VXF1GP2R INSTALLATION GUIDE PAGE 1 of 2 BEFORE BEGINNING YOUR INSTALLATION Read through the instruction guide before getting started with the installation. Professional installation is recommended for this product. CONTENTS  Single Gauge Black Powder Coated Metal Dash Panel  Two 3-Position Momentary Rocker Switches (Pre-installed) SAFETY INS …
  • Atlas Copco

    AUTOMAN AC40

    (40 pages)
    Instructions manual ENCompressorsType AC40 to AC10062 305 013 01 ed00GUARANTEEThe AC 40 to 100 is guaranteed for 12 months as of the date of commissioningthe maximum duration of the guarantee is 18 months as of the date of manufacturing.Particular conditions :For the compressors from 4 to 5,5 ch included: the guarantee excludes travel expensesThe guarantee w …
  • Air Armor

    M240

    (2 pages)
    Owner’s Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING YOUR AIR COMPRESSOR Q Industries Inc. 401 East Las Olas Blvd., Suite 130 Fort Lauderdale, Florida 33301 P: 954.689.2263 F 303.568.7700 E Mail: [email protected] Parts and Accessories are available at: www.qindustries-store.net SPECIFICATIONS Motor: 12-Volt D …
  • Powermate

    200-2504

    (8 pages)
    200-2504Revision BParts ManualManuel de piècesManual de piezasSpecification Chart________Tableau des spécifications_______Cuadro de especificacionesQuestions? See back pages.___Questions ? Consultez la pages final.___¿Preguntas? Vea la páginas final.?Single Stage, Belt Drive, Electric Air CompressorsD’une seule étape, actionnement pour courroie, compr …
  • Craftsman

    919.152141

    (25 pages)
    Owner's ManualPermanently LubricatedTank MountedAIR COMPRESSORModel No.919.152141• Safety Guidelines• Assembly• Operation• Maintenance• Service and Adjustments• Troubleshooting• Repair PartsCAUTION: Read the Saf_y Guidelinesand All Instructions Carefully BeforeOpsr_ing.Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.Visit our Cre_t …
  • Kobalt

    K7045V

    (8 pages)
    Air CompressorManualFor Kobalt ModelsK7580V2StationaryFor questions concerning this air compressor,please call: 1-866-242-4298.Printed In USAStationary Compressor Limited Warranty Lowe’s Kobalt Models K7045V, K7060HFV & K7580V2 Warranty This warranty of the Lowe’s Kobalt Stationary Single-Stage Models K7045V and K7060HFV, and Stationary Two-Stage M …

Comments, Questions and Opinions: