Text of INVERTEC optidrive E IP20 User Guide:

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 2 www.invertekdrives.com 1 Quick Start Up 1. Quick Start Up...................................................................................................................................................................... 4 1.1. Important Safety Information 4 1.2. Quick Start Process 5 2. General Information and Ratings ......................................................................................................................................... 7 2.1. Identifying the Drive by Model Number 7 2.2. Drive Model Numbers 7 3. Mechanical Installation .........................................

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 www.invertekdrives.com 9 3 Mechanical Installation 3.5. Mechanical Dimensions – IP66 (Nema 4X) Enclosed Units Drive Size A B D E F G H I J Weight mm in mm in mm in mm in mm In mm in mm in mm in mm in kg lb 1 232.0 9.13 207.0 8.15 189.0 7.44 25.0 0.98 179.0 7.05 161.0 6.34 148.5 5.85 4.0 0.16 8.0 0.31 3.1 6.8 2 257.0 10.12 220.0 8.67 200.0 7.87 28.5 1.12 187.0 7.36 188.0 7.40 176.0 6.93 4.2 0

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 www.invertekdrives.com 27 9 Technical Data 9.3. Additional Information for UL Compliance Optidrive E3 is designed to meet the UL requirements. For an up to date list of UL compliant products, please refer to UL listing NMMS.E226333 In order to ensure full compliance, the following must be fully observed. Input Power Supply Requirements Supply Voltage 110 – 115 RMS Volts for 115 Volt rated units, + /- 10% variation allowed. 115 Volt RMS Maximum 200 – 240 RMS Volts for 230 Volt rated units

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 www.invertekdrives.com 3 1 Quick Start Up Declaration of Conformity Invertek Drives Ltd hereby states that the Optidrive ODE-3 product range conforms to the relevant safety provisions of the following council directives: 2004/108/EC (EMC) and 2006/95/EC (LVD) (Valid until 20.04.2016) 2014/30/EU (EMC) and 2014/35/EU (LVD) (Valid from 20.04.2016) Designed and manufacture is in accordance with the following harmonised European standards:

  • Optidrive ODE-3 1Ph Output User Guide Revision 1.00 16 www.invertekdrives.com 6 Parameters 6. Parameters 6.1. Standard Parameters Par. Description Minimum Maximum Default Units P-01 Maximum Frequency / Speed Limit P-02 500.0 50.0 (60.0) Hz / RPM Maximum output frequency or motor speed limit – Hz or RPM. If P-10 >0, the value entered / displayed is

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 28 www.invertekdrives.com 10 Trouble Shooting 10. Trouble Shooting 10.1. Fault Code Messages Fault Code No. Description Suggested Remedy  00 No Fault Not required  01 Brake channel over current Check external brake resistor condition and connection wiring  02 Brake resistor overload The drive has tripped to prevent damage to the brake resistor  03 Output Over Current Instantaneous Over current on the drive output. Excess load or shock loa

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 6 www.invertekdrives.com 1 Quick Start Up Quick Start – IP20 & IP66 Non Switched Connect a Start / Stop switch between control terminals 1 & 2 5k – 10k Close the Switch to Start Open to Stop Connect a potentiometer (5k – 10kΩ) between terminals as shown to vary the speed from P-2 (0Hz default) to P-01 (50 / 60 Hz default) 0....10V 0.......50/60Hz Quick Start – IP66 Switched Switch the unit on using the isolator switch on the pan

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 www.invertekdrives.com 5 1 Quick Start Up 1.2. Quick Start Process Step Action See Section Page 1 Identify the Enclosure Type, Model Type and ratings of your drive from the model code on the label. In particular - Check the voltage rating suits the incoming supply - Check the output current capacity meets or exceeds the full load current for the intended motor 2.1 Identifying the Drive by Model Number 7 2 Unpack and check the drive. Notify the supplier and shipp

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 www.invertekdrives.com 19 6 Parameters Par. Description Minimum Maximum Default Units P-37 Access Code Definition 0 9999 101 - Defines the access code which must be entered in P-14 to access parameters above P-14 P-38 Parameter Access Lock 0 1 0 - 0 : Unlocked. All parameters can be accessed and changed 1 : Locked. Parameter values can be displayed, but cannot be changed except P-38. P-39 Analog Input 1 Offset

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 www.invertekdrives.com 13 4 Power Wiring 4.8. Connection Diagram Power Connections A Incoming Power Supply B External Isolator / Disconnect C External MCB or Fuse D Optional Input Choke E Optional Input Filter F Optional Brake Resistor G Shielded Motor Cable H Analog / Digital Output I Relay Output Control Connections See section 4.10 8 Analog Output 0 – 10 Volts 9 0 Volt 10 Relay Output ‘Drive Healthy’ = Closed 11

  • Optidrive ODE-3 1Ph Output User Guide Revision 1.00 8 www.invertekdrives.com 3 Mechanical Installation 3. Mechanical Installation 3.1. General  The Optidrive should be mounted in a vertical position only, on a flat, flame resistant, vibration free mounting using the integral mounting holes or DIN Rail clip.  IP20 Optidrives must be install

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 www.invertekdrives.com 15 5 Operation 5. Operation 5.1. Managing the Keypad The drive is configured and its operation monitored via the keypad and display. NAVIGATE Used to display real-time information, to access and exit parameter edit mode and to store parameter changes UP Used to increase speed in real-time mode or to increase parameter values in parameter edit mode DOWN Used to decrease speed in real-time mode or to decrease parameter values in parameter edit mode RESET / STOP Used to reset

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 www.invertekdrives.com 17 6 Parameters 6.2. Extended Parameters Par. Description Minimum Maximum Default Units P-15 Digital Input Function Select 0 17 0 - Defines the function of the digital inputs depending on the control mode setting in P-12. See section 7 Analog and Digital Input Macro Configurations for more information. P-16 Analog Input 1 Signal Format See Below U0-10 -  = Uni-polar 0 to 10 Volt Signal. The

  • Optidrive ODE-3 1Ph Output User Guide Revision 1.00 22 www.invertekdrives.com 7 Analog and Digital Input Macro Configurations 7. Analog and Digital Input Macro Configurations 7.1. Overview Optidrive E3 uses a Macro approach to simplify the configuration of the Analog and Digital Inputs. There are two key parameters which determine the input functions and dri

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 14 www.invertekdrives.com 4 Power Wiring 4.9. Using the REV/0/FWD Selector Switch (Switched Version Only) By adjusting the parameter settings the Optidrive can be configured for multiple applications. This could typically be for Hand/Off/Auto applications (also known and Local/Remote) for HVAC and pumping industries. Note : Forward / Reverse operation of single phase motors is not possible Switch Position Parameters to Set Notes P-12 P-15 Run (Pot)

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 10 www.invertekdrives.com 3 Mechanical Installation 3.7. Gland Plate and Lock Off The use of a suitable gland system is required to maintain the appropriate IP / Nema rating. The gland plate has pre moulded cable entry holes for power and motor connections suitable for use with glands as shown in the following table. Where additional holes are required, these can be drilled to suitable size. Please take care when drilling to avoid leaving any particles within the product. Cable Gland recommended Hole Sizes & types:

  • Optidrive ODE-3 1Ph Output User Guide Revision 1.00 www.invertekdrives.com 25 8 Modbus RTU Communications 8. Modbus RTU Communications 8.1. Introduction The Optidrive E3 can be connected to a Modbus RTU network via the RJ45 connector on the front of the drive. 8.2. Modbus RTU Specification Protocol Modbus RTU Error check CRC Baud rate 9600bp

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 24 www.invertekdrives.com 7 Analog and Digital Input Macro Configurations 7.7. Fire Mode The Fire Mode function is designed to ensure continuous operation of the drive in emergency conditions until the drive is no longer capable of sustaining operation. The Fire Mode input may be a normally open (Close to Activate Fire Mode) or Normally Closed (Open to Activate Fire Mode) according to the setting of P-30 Index 2. In addition, the input may be momentary or maintained type, selected by P-30 Index 3. This input may be linked to a fire control system to

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 www.invertekdrives.com 7 2 General Information and Ratings 2. General Information and Ratings This chapter contains information about the Optidrive E3 including how to identify the drive 2.1. Identifying the Drive by Model Number Each drive can be identified by its model number, as shown in the table below. The model number is on the shipping label and the drive nameplate. The model number includes the drive and any options. ODE - 3 -

  • INVERTEC optidrive E IP20, Optidrive ODE-3 1Ph Output User Guide Revision 1.00 www.invertekdrives.com 23 7 Analog and Digital Input Macro Configurations P-15 DI1 DI2 DI3 / AI2 DI4 / AI1 Diagram 14 STOP RUN DI2 E-TRIP  OK DI2 DI4 PR 14 0 0 P-20 1 0 P-21 0 1 P-22 1 1 P-23 15 STOP RUN P-23 REF AI1 Fire Mode Analog Input AI1 2 16 STOP RUN P-23 REF P-21 REF Fire Mode No Function 3 17 STOP RUN DI2 Fire Mode DI2 DI4 PR 3 0 0 P-20 1 0 P-21 0 1 P-22 1 1 P-23 7.4. Macro Func

Related Products and Documents (Controller):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Lexmark W850 Maintenance manual lexmark/w850-DY1.pdf 28 Sep 2023 15
2 Essentials KE7542 Instruction manual essentials/ke7542-916.pdf 24 Feb 2024 12
3 Omnitronic CPA-5200 Operation & user’s manual omnitronic/cpa-5200-69Z.pdf 07 Jan 2024 22
4 Samsung DVD-P548K Operation & user’s manual samsung/dvd-p548k-DTK.pdf 27 Feb 2023 19 2.06 Mb
5 Craftsman 315.116271 Owner's manual craftsman/315-116271-38N.pdf 14 Dec 2022 12 0.47 Mb
6 Bongioanni Multidea Evo 60 Installation and maintenance instructions manual bongioanni/multidea-evo-60-981.pdf 30 Jun 2022 64

Similar Resources:

  • Doli

    EDC580

    (2 pages)
    EDC580 EDC580 1 1 6) 4ETF/4FAD montieren, BNC Adapter aufschrauben / mount 4ETF/4FAD and screw down BNC adaptor / 安装 4ETF 或 4FAD 模板,用螺钉拧紧 BNC 转接头 Siehe Schritte 3 und 4. / see steps 3 and 4. / 见步骤 3 和 4 7) Deckel wieder montieren / Remount the lid / 重新安装上盖 Siehe Schritt 1 in umgekehrter Reihenfolge. / Se …
  • Lunos

    5/ZII

    (4 pages)
    Einbauanleitung für den Micro Controller-Zeitnachlauf Typ 5/ZII - Bitte an den Nutzer weiterleiten - Anwendung Das Zeitnachlaufmodul 5/ZII ist eine programmierbare Steuerung für Lüfter-motore: Funktionen - Einschaltverzögerung - Nachlaufzeit - Inversbetrieb - Intervallschaltung Eine Kopplung mit der Raumbeleuch-tung ist möglich. Sachfremde Anwen …
  • Store It Cold

    CoolBot

    (2 pages)
    Rev: 2017 – 1A ©2017 Store It Cold, LLC. QUICK START SET UP GUIDE STEP 1 Plug the wires into the corresponding labelled ports at the bottom of the CoolBot temperature controller. STEP 2 Mount the CoolBot on the wall next to the A/C’s control panel side. STEP 3 Remove the air filters from the front of …
  • Phocos

    Any-Grid PSW-H-5kW-230/48V

    (5 pages)
    Phocos Any-Grid™ series Any-Grid™ use with Lithium battery models: Arco Invincible III Applicable for Any-Grid™ PSW-H-5kW-230/48V, PSW-H-5kW-120/48V and PSW-H-6.5kW-120/48V Recommended battery settings guide …
  • Mateksys

    F722-SE

    (6 pages)
    Nov.2018 Rev 1.0 www.mateksys.comFLIGHT CONTROLLER F722-SEBASIC MANUALMCU: 216MHz STM32F722RET6IMU: MPU6000 & ICM20602, Dual Gyros built-inBaro: BMP280OSD: AT7456EBlackbox: MicroSD card slot5x Uarts (1,2,3,4,6) with built-in inversion1x Softserial supported8x Dshot/Proshot/oneshot outputs1x I2C4x RX6 pads for BLheli32 ESC telemetry4x individual ESC pow …
  • Varian

    MiniVac 929-0190

    (28 pages)
    87-900-049-01 (E) APRIL 2006 (I) MANUALE DI ISTRUZIONI (D) BEDIENUNGSHANDBUCH (F) NOTICE DE MODE D’EMPLOI (GB) INSTRUCTION MANUAL MiniVac Controller Model 929-0190 Model 929-0290 Model 929-0191 Model 929-0291 vacuum technologies …

Comments, Questions and Opinions: