  • HP ProCurve 9304M, v Twisted-Pair Cable for Switch (MDI-X) to Hub or Switch (MDI-X) Network Connection . . . . . . . . . . . . . . . . . . . B-3 Twisted-Pair Cable Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . B-4 Twisted-Pair Straight-Through Cable . . . . . . . . . . . . . . . . . . . . . . B-4 Twisted-Pair Cross-Over Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4 Fiber-Optic Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5 10Base-FL Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • HP ProCurve 9304M, Index – 1 Index Index Numerics 10/100Base-TX ports location on switch … 1-2 100Base-FX connections, length limitations … 2-4 ports, cables used with … 2-4, B-5 100Base-TX connections, length limitations … 2-4 ports, cables used with … 2-4 10Base-FL connections, length limitations … 2-4 ports, cables used with … 2-4, B-5 10Base-T connections, length limitations … 2-4 ports, cables used with … 2-4 A address learning … 1-8 address table automatic address learning … 1-8 filterin

  • HP ProCurve 9304M, B-5 Cables and Connectors Fiber-Optic Cables Cables and Connectors Fiber-Optic Cables 10Base-FL Ports Fiber-optic cables connected to the 10Base-FL Switch Module ports must be 1300 nm wavelength, multimode cable conforming to the ISO/IEC 793-2 type B1, and ITU-T G.652 standards, and the cables must have ST-type connectors. 100Base-FX Ports Fiber-optic cables connected to the 100Base-FX Switch Module ports must be 1300 nm wavelength, multimode cable conforming to the ISO/IEC 793-2 type B1, and ITU-T G.652 standards, and the cables must have SC-type connectors. Gigabit-SX Ports Fiber-optic cab

  • 3-7 Troubleshooting Hardware Diagnostic Tests Troubleshooting Hardware Diagnostic Tests Testing the Switch by Resetting It If you believe that the switch is not operating correctly, you can reset the switch to test its circuitry and operating code. To reset a switch, either: ■ Unplug and plug in the power cord (power cycling) ■ Press the reset button on the front of the switch Power cycling t

  • HP ProCurve 9304M, B-3 Cables and Connectors Twisted-Pair Cable/Connector Pin-Outs Cables and Connectors Twisted-Pair Cable for Switch (MDI-X) to Hub or Switch (MDI-X) Network Connection To connect hubs or switches or other MDI-X network devices to these ports, use a “crossover” cable. Note Pins 1 and 2 on connector “A” must be wired as a twisted pair to pins 3 and 6 on connector “B”. Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 1 and 2 on connector “B”. Pins 4, 5, 7, and 8 are not used in this application, although they may be wired in the cable. . Crossover Cable white/orange orange/white white/green gre

  • 1-3 Introducing the HP Switch 1600M Front of the Switch Introducing the HP Switch 1600M Clear Button This button is used for these purposes: ■ Deleting Passwords - When pressed by itself for at least one second, deletes any switch console access passwords that you may have config- ured. Use this feature if you have misplaced the password and need console access. This button is provide

  • HP ProCurve 9304M, 1-1 Introducing the HP Switch 1600M 1 Introducing the HP Switch 1600M The HP Switch 1600M is a multiport switch that can be used to build high- performance switched workgroup networks. This switch is a store-and- forward device that offers low latency for high-speed networking. Throughout this manual, this switch will be abbreviated as the Switch 1600M. The Switch 1600M has 16 10/100Base-T RJ-45 ports, and a slot for installing any of the supported switch modules. At the time of this printing, there are 4: ■ HP J4111A Switch 10/100Base-T Module (8 RJ-45 ports) ■ HP J4112A Switch 100Base-FX Module (4 SC-connector fiber-optic ports) ■ HP J4113A Sw

  • HP ProCurve 9304M, A-1 Specifications A Specifications Physical Electrical The switch automatically adjusts to any voltage between 100-127 and 200-240 volts and either 50 or 60 Hz. Environmental Acoustic Geraeuschemission LwA=54 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19 Width: 44.2 cm (17.4 in) Depth: 33.5 cm (13.2 in) Height: 6.6 cm (2.6 in) Weight : 4.5 kg (9.9 lbs) AC voltage: 100–127 volts 200–240 volts Maximum current: 1.0 A 0.6 A Frequency range: 50/60 Hz 50/60 Hz Operating Non-Operating Temperature: 0°C to 55°C (32°F to 131°F) -40°C to 70°C (-40°F to 158°F) Relative humidity: (non-condensing) 15% to 95% at 40°C (104�

  • HP ProCurve 9304M, 1-8 Introducing the HP Switch 1600M Switch Operation Overview Introducing the HP Switch 1600M Switch Operation Overview Address Table Operation Address Learning. As devices are connected to the switch ports, either directly or through hubs or other switches that are connected to the switch, the MAC addresses of those devices are learned automatically and stored in the Switch 1600M’s 8000-entry address table. The switch also identifies the number of the port on which each address is learned so

  • HP ProCurve 9304M, Hewlett-Packard Company 8000 Foothills Boulevard, m/s 5552 Roseville, California 95747-5552 http://www.hp.com/go/network_city © Copyright 1998 Hewlett-Packard Company All Rights Reserved. This document contains information which is protected by copyright. Reproduction, adaptation, or translation without prior permission is prohibited, except as allowed under the copyright laws. Publication Number J4120-90001 June 1998 Applicable Products HP ProCurve Switch 1600M (HP J4120A) Disclaimer The information con

  • HP ProCurve 9304M, 2-9 Installing the Switch 1600M Installation Summary Installing the Switch 1600M 2. Partially install a screw (5/8-inch number 12-24) into the top hole of a pair of holes that are 0.5 inches apart in each rack/cabinet upright as shown in the illustration below. Ensure that the screws are at the same level in each upright. . 3. Place the switch in the rack and lower it so the notches in the bottom of the bracket slide onto the screws, then tighten these screws. . partially install a screw into the top hole of a close (0.5-inch) pair on both sides of the rack lower switch with mounting brackets onto the partially installed screw Def_hw~1.boo : DEFHW2.FM Page 9 Thursday, May 21

  • C-8 Safety and EMC Regulatory Statements EMC Regulatory Statements Safety and EMC Regulatory Statements EMC Regulatory Statements U.S.A. FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference whe

  • HP ProCurve 9304M, 3-8 Troubleshooting Hardware Diagnostic Tests Troubleshooting Testing Twisted-Pair Cabling If you think the cable should work but still isn’t working, it may not be compatible with the IEEE 802.3 Type 10Base-T or 100Base-T standards. The twisted-pair cables attached to the Switch 1600M must be compatible with these standards.To verify that your cable is compatible with these standards, use a qualified cable test device. HP also offers a wire testing service. Contact your HP-authorized LAN dealer or your local HP sales office for more information. Note Make sure that you are using the correct cabling type for each connection. The switch UTP

  • HP ProCurve 9304M, B-2 Cables and Connectors Twisted-Pair Cable/Connector Pin-Outs Cables and Connectors Twisted-Pair Cable for Switch (MDI-X) to Computer (MDI) Network Connection To connect PCs or other MDI network devices to these ports, use a “straight- through” cable. Note Pins 1 and 2 on connector “A” must be wired as a twisted pair to pins 1 and 2 on connector “B”. Pins 3 and 6 on connector “A” must be wired as a twisted pair to pins 3 and 6 on connector “B”. Pins 4, 5, 7, and 8 are not used in this application, although they may be wired in the cable. . Strai

  • HP ProCurve 9304M, 2-15 Installing the Switch 1600M Hot Swapping the Switch Port Module Installing the Switch 1600M Hot Swapping the Switch Port Module The switch port module can be “hot swapped”, that is installed or replaced while the switch is powered on. The procedures differ slightly, though between adding a new module to the empty slot or replacing the module with the same type, and exchanging the module with a different type. Adding or Replacing the Module If a module has to be replaced with one of the same type, or you are expanding the switch capability by adding a module when one was not previ

  • HP ProCurve 9304M, 1-4 Introducing the HP Switch 1600M Front of the Switch Introducing the HP Switch 1600M Table 1-2. Switch Port Module LEDs Self Test (green) Off The normal operational state; the switch is not undergoing self test. On The switch self test and initialization are in progress after you have power cycled or reset the switch. The switch is not operational until this LED goes off. The Self Test LED also comes on briefly when you “hot swap” a module into the switch; the module is self tested when hot swapped. Flashing † A component of the switch has failed its self test. The status LED for that component, for example a fan, and the switch Fa

  • HP ProCurve 9304M, 3-4 Troubleshooting Diagnosing with the LEDs Troubleshooting Diagnostic Tips: Tip Number Problem Solution  The switch is not plugged into an active AC power source, or the switch’s power supply may have failed. 1. Verify that the power cord is plugged into an active power source and to the switch. Make sure these connections are snug. 2. Try power cycling the switch by unplugging and plugging the power cord back in. 3. If the Power LED is still not on, verify that the AC power source works by plugging another devic

  • HP ProCurve 9304M, 2-10 Installing the Switch 1600M Installation Summary Installing the Switch 1600M 4. Install the other number 12-24 screw into the upper hole in each bracket. Tighten these screws. Horizontal Surface Mounting Place the switch on a table or other horizontal surface. Use a sturdy surface in an uncluttered area. You may want to secure the networking cables and switch power cord to the table legs or other part of the surface structure to help prevent people from tripping over the cords. Note Make sure the air flow is not restricted around the sides and back of the switch. install additional screw Def_hw~1.boo : DEFHW2.FM Page 10 Thursday, May 21, 1998 5:36 PM

  • HP ProCurve 9304M, 3-9 Troubleshooting HP Customer Support Services Troubleshooting Testing End-to-End Network Communications Both the switch and the cabling can be tested by running an end-to-end communications test -- a test that sends known data from one network device to another through the switch. For example, if you have two PCs on the network that have LAN adapters between which you can run a link-level test or Ping test through the switch, you can use this test to verify that the entire communication path between the two PCs is functioning cor

  • HP ProCurve 9304M, B-4 Cables and Connectors Twisted-Pair Cable/Connector Pin-Outs Cables and Connectors Twisted-Pair Cable Pin Assignments Twisted-Pair Straight-Through Cable Twisted-Pair Cross-Over Cable Switch End (MDI-X) Computer, Transceiver, or Other MDI Port End Signal Pins Pins Signal receive + receive - transmit + transmit - 1 2 3 6 1 2 3 6 transmit + transmit - receive + receive - Switch End (MDI-X) Hub or Switch Port, or Other MDI-X Port End Signal Pins Pins Signal receive + receive - transmit + transmit - 1 2 3 6 6 3 2 1 transmit - transmit + receive -

  • HP ProCurve 9304M, 1-9 Introducing the HP Switch 1600M Switch Operation Overview Introducing the HP Switch 1600M Simultaneous Network Communications In addition to traffic isolation benefits provided by the Switch 1600M address table operation, the switch also enhances network performance because it can conduct multiple, simultaneous network connections. Instead of sharing the network bandwidth, as in connections to a hub, each connection has its own 10 Mbps, 100 Mbps, or 1000 Mbps bandwidth to use. Effect of VLANs If you configure multiple virtual LAN

  • HP ProCurve 9304M, 1-7 Introducing the HP Switch 1600M Features Introducing the HP Switch 1600M Features The features of the Switch 1600M include: ■ 16 10/100Base-TX RJ-45 ports ■ a slot for installing any of the available switch port modules—as of this printing, this includes: • 8-port 10/100Base-TX Module with RJ-45 connectors • 4-port 100Base-FX Module with fiber-optic SC connectors • 1-port Gigabit-SX Module with fiber-optic SC connector • 4-port 10Base-FL Module with fiber-optic ST connectors ■ the module is “hot swappable” ■ plug-and-play networking—all

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Alesis QuadraVerb GT Service manual alesis/quadraverb-gt-AVQ.pdf 05 Nov 2023 33
2 Candy CC2 66T Instruction book candy/cc2-66t-476.pdf 04 Dec 2023 40 1.34 Mb
3 Jade CHITWOOD SMOKE BROILER KC-24 Features & dimensions jade/chitwood-smoke-broiler-kc-24-65N.pdf 28 Jun 2023 2
4 Coleman 9730 Instructions for use coleman/9730-FOV.pdf 07 Aug 2023 2 0.15 Mb
5 Sony VGN-TX850P Quick start sony/vgn-tx850p-1AR.pdf 24 Jul 2023 2
6 Silver King SKUCF7F Technical manual and replacement parts list silver-king/skucf7f-184.pdf 10 Mar 2024 12 2.36 Mb

Similar Resources:

  • ZyXEL Communications

    VMG1312

    (124 pages)
    1 ZyXEL Confidential www.zyxel.com ZyXEL VMG1312 Broadband Router CLI Reference Manual Version 1.0 04/22/2013 …
  • Cisco

    12000 - Series Chassis Modular Expansion Base

    (62 pages)
    CHAPTER2-1Cisco 12000 Series Router SIP and SPA Hardware Installation GuideRelease 12.0(33)S, OL-8831-01, Rev. G92Overview: Cisco 12000 Series Router Shared Port AdaptersRelease 12.0(33)S, OL-8831-01, Rev. G9This chapter describes the shared port adapters (SPAs) that are supported on the Cisco 12000 Series Router and contains the following sections:• SPA S …
  • SMC Networks

    SMC EZ Connect SMC70032AE

    (2 pages)
    BenefitsSMC70032AEModel Number::EZ ConnectTMADSL Ethernet Modem• Supports both voice and fast Internet access over the existing telephone lines.• ST Microelectronic/Virata chipset• Compliant to G.dmt (ITU G.992.1),ANSI T1.413 Issue 2,and G.lite(ITU G.992.2)• Built-in micro-filter.2 port RJ-11 connector (ADSL line and phone interface)• One 10Mbps Et …
  • TRENDnet

    TW100-BRF114

    (2 pages)
    TRENDnet's TW100-BRF114 4-Port Cable/DSL Firewall Router allows multiple users to share internet access pro-tected from unwanted intruders via a robust Stateful Packet Inspection Firewall (SPI). The Firewall provides advanced protection against popular Denial of Service attacks. Multiple Web Patrol features allow parents and Netwo …
  • Moxa Technologies

    ToughNet TN-5524-8PoE-P24-T

    (12 pages)
    P/N: 1802055240012 *1802055240012* TN-5524-8PoE Quick Installation Guide Moxa ToughNet Switch Edition 3.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778 Moxa China (Shanghai office): Toll-free: 800-820-5036 Tel: +86-21-5258-9955 Fax: +86-21-5258- …
  • Cisco

    SFE2000 - Small Business Managed Switch

    (21 pages)
    Release Notes for Cisco Small Business SFE2000 Series 24-port 10/100 Ethernet Switches 1Release Notes Release Notes for Cisco Small Business SFE2000 Series 24-port 10/100 Ethernet SwitchesNovember 20, 2008These release notes contain important information about the Cisco SFE2000 24-port 10/100 Ethernet Switch family and any limitations, restrictions, or cavea …

Comments, Questions and Opinions: