  • HP MSA 2040, Device description 45 5 Connecting to the controller CLI port Device description The MSA 2040 controllers feature a command-line interface port used to cable directly to the controller and initially set IP addresses, or perform other configuration tasks. This port employs a mini-USB Type B form factor, requiring a cable that is supplied with the controller, and additional support, so that a server or other computer running a Linux or Windows operating system can recognize the controller enclosure as a connected device. Without this

  • HP MSA 2040, Installation checklist 19 3Installing the enclosures Installation checklist The following table outlines the steps required to install the enclosures and initially configure the system. To ensure a successful installation, perform the tasks in the order they are presented. 1 The SMU is introduced in "Accessing the SMU" (page 51). See the SMU Reference Guide or online help for additional information. 2 If the systems are cabled for replication and licensed to use the Remote Snap feature, you can use the Replication Setup Wizard to prepare to replicate an existing volume to another vdisk. See the SMU Reference Guide for additional information. FDE considerations The Full Disk Encry

  • HP MSA 2040, Resolving voltage and temperature warnings 69 Power supply module voltage sensors Power supply voltage sensors ensure that the enclosure power supply voltage is within normal ranges. There are three voltage sensors per power supply. Table 25 Voltage sensor descriptions Sensor Event/Fault LED condition Power supply 1 voltage, 12V < 11. 0 0 V > 13.00V Power supply 1 voltage, 5V < 4.00V > 6.00V Power supply 1 voltage, 3.3V < 3.00V > 3.80V

  • HP MSA 2040, 58 Troubleshooting NOTE: See "FDE considerations" (page 19). Is a connected host port Host Link Status LED off? Is a connected port Expansion Port Status LED off? Yes, and the Online/Activity LED is off. The disk drive is offline. A predictive failure alert may have been received for this device. • Check the event log for specific information regarding the fault. • Isolate the fault. • Contact an authorized service provider for assistance. Yes, and the Online/Activity LED is blinking. The disk drive is active, but a predictive failure alert may have been received for this device. • Check the event log for specific information regarding the fault

  • 66 Troubleshooting Can you replicate a volume? Can you view a replication image? Can you view remote systems? Answer Possible reasons Actions Yes System functioning properly. No action required. No Remote Snap is not licensed on each controller enclosure used for replication. See actions described in "Can you successfully use the Remote Snap feature?" (page 64). No

  • HP MSA 2040, Powering on/powering off 29 Figure 16 AC power supply To power on the system: 1. Obtain a suitable AC power cord for each AC power supply that will connect to a power source. 2. Plug the power cord into the power cord connector on the back of the drive enclosure (see Figure 16). Plug the other end of the power cord into the rack power source. Wait several seconds to allow the disks to spin up. Repeat this sequence for each power supply within each drive enclosure. 3. Plug the power cord into the power cord connector on the back of the controller enclosure (see Figure 16). Plug the other end of the

  • HP MSA 2040, Connecting the enclosure to data hosts 37 Four servers/one HBA per server/dual path Figure 22 Connecting hosts: direct attach—four servers/one HBA per server/dual path Connecting switch attach configurations Dual controller configuration Two servers/two switches Figure 23 Connecting hosts: switch attach—two servers/two switches 6Gb/s S S A 6Gb/s S S A Server 1 Server 2 Server 3 Server 4 MSA 2040 SAN 12Gb/s S S A 12Gb/s S S A 6Gb/s S S A 6Gb/s S S A 12Gb/s S S A 12Gb/s S S A Server 1 Server 2 Server 3 Server 4 MSA 2040 SAS 6Gb/s S S A 6Gb/s S S A Server 1 Server 2

  • HP MSA 2040, Connecting controller and drive enclosures 25 Figure 13 Cabling connections between MSA 2040 controllers and drive enclosures of mixed model type The figure above provides sample diagrams reflecting cabling of MSA 2040 controller enclosures and supported mixed model drive enclosures. In this example, the SFF drive enclosures follow the LFF drive enclosures. Given that both drive enclosure models use 6 Gb SAS link-rate and SAS2.0 expanders, they can be ordered in desired sequence within the array, following the controller enclosure. The diagram at left shows fault-tolerant cabling of a dual-controller enclosure and mixed model driv

  • HP MSA 2040, Isolating a host-side connection fault 61 3. Check the Cache Status LED to verify that the controller cached data is flushed to the disk drives. • Solid – Cache contains data yet to be written to the disk. • Blinking – Cache data is being written to CompactFlash. •Flashing at 1/10 second on and 9/10 second off – Cache is being refreshed by the supercapacitor. • Off – Cache is clean (no unwritten data). 4. Remove the SFP and host cable and inspect for damage. 5. Reseat the SFP and host cable. Is the host link status/link activity LED on? • Yes – Monitor the status to ensure that there

  • HP MSA 2040, © Copyright 2014 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products

  • HP MSA 2040, 78 Regulatory information Warranty information HP Proliant Servers http://www.hp.com/support/ProliantServers-Warranties HP Enterprise Servers http://www.hp.com/support/EnterpriseServers-Warranties HP Storage Products http://www.hp.com/support/Storage-Warranties HP Networking Products http://www.hp.com/support/Networking-Warranties

  • HP MSA 2040, Using the CLI port and cable—known issues on Windows 49 Using the CLI port and cable—known issues on Windows When using the CLI port and cable for setting controller IP addresses, be aware of the following known issues on Microsoft Windows platforms. Problem On Windows operating systems, the USB CLI port may encounter issues preventing the terminal emulator from reconnecting to storage after the Management Controller (MC) restarts or the USB cable is unplugged and reconnected. Workaround Follow these steps when using the mini-USB cable and USB Type B CLI port to communicate out-of-band between the host and controller module for setting network port IP addresses. To cr

  • HP MSA 2040, Contents 3 1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 MSA 2040 Storage models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 MSA 2040 SAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 MSA 2040 SAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Fea

  • 90 Specifications and requirements • Site wiring must include an earth ground connection to the DC power source. Grounding must comply with local, national, or other applicable government codes and regulations. • Power circuits and associated circuit breakers must provide sufficient power and overload protection. Weight and placement guidelines Refer to &qu

  • HP MSA 2040, Connecting two storage systems to replicate volumes 41 The diagram below shows host interface connections and replication, with I/O and replication occurring on different networks. For optimal protection, use two switches. Connect two ports from each controller module to the first switch to facilitate I/O traffic, and connect two ports from each controller module to the second switch to facilitate replication. Using two switches in tandem avoids the potential single point of failure inherent to using a single switch, however, if one switch fails, either I/O or replication will fail, depending on which of the switches fails. Figure 27 Connecting two storage systems fo

  • 6Contents C Specifications and requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Safety requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Site requirements and guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • HP MSA 2040, 48 Connecting to the controller CLI port set network-parameters ip address netmask netmask gateway gateway controller a|b where: • address is the IP address of the controller • netmask is the subnet mask • gateway is the IP address of the subnet router • a|b specifies the controller whose network parameters you are setting For example: # set network-parameters ip 192.168.0.10 netmask 255.255.255.0 gateway 192.168.0.1 controller a # set network-parameters ip 192.168.0.11 netmask 255.255.

  • HP MSA 2040, 60 Troubleshooting If the controller has failed or does not start, is the Cache Status LED on/blinking? NOTE: See also "Cache Status LED details" (page 86). Transporting cache To preserve the existing data stored in the CompactFlash, you must transport the CompactFlash from the failed controller to a replacement controller using the procedure outlined in HP MSA Controller Module Replacement Instructions shipped with the replacement controller module. Failure to use this procedure will result in the loss of data stored in the cache module. CAUTI

  • HP MSA 2040, 72 Support and other resources Prerequisites Knowledge of relevant topics is required for installing and using this product: • Servers and computer networks • Network administration • Storage system installation and configuration • Storage area network management • Relevant protocols: • Fibre Channel (FC) • Internet SCSI (iSCSI) • Serial Attached SCSI (SAS) •Ethernet Troubleshooting resources See Troubleshooting for simple procedures pertaining to initial setup of the controller enclosure hardware. The chapter describes fault isolation methodolog

Related Products and Documents (Network Hardware):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Phase Linear UV8020 Installation and operation manual phase-linear/uv8020-1KW.pdf 22 Dec 2023 30
2 Sanyo VCC-5884E - 1/3" Color CCD DSP High-Resolution Camera Specifications sanyo/vcc-5884e-1-3-color-ccd-dsp-high-resolution-camera-7WD.pdf 19 Jun 2022 2 0.34 Mb
3 Carson Z-80S Instructions carson/z-80s-AVI.pdf 20 Nov 2022 1 2.96 Mb
4 Stearns 429-07 Instructions stearns/429-07-67N.pdf 06 Feb 2024 1 0.33 Mb
5 Audio Pro wigo Wi-130 Technical data audio-pro/wigo-wi-130-6X5.pdf 04 Nov 2022 4 0.07 Mb
6 Wasp WPL25 Operation & user’s manual wasp/wpl25-H23.pdf 18 Dec 2023 40

Similar Resources:

  • Texas Instruments

    DRV8308

    (18 pages)
    User’s Guide SLVUA41E – May 2015 1 DRV8308 User’s Guide This document describes how to use the DRV8308EVM to spin sensored brushless DC motors, as well as a tuning process for the DRV8308 speed control system. Table of Contents 1. The DRV8308EVM and motor.................................. 2 1.1 Overview .............................. …
  • Juniper

    NFX250

    (7 pages)
    Quick Start GuideNFX250IN THIS GUIDEStep 1: Begin | 1Step 2: Up and Running | 3Step 3: Keep Going | 6Step 1: BeginIN THIS SECTIONMount the NFX250 | 2Connect Power to the NFX250 | 3To mount and connect power to the Juniper Networks®NFX250 Network Services Platform, and perform initialconfiguration, you need:•Electrostatic discharge (ESD) grounding strap (n …
  • Sony

    PWS-110RX1A

    (78 pages)
    NETWORK RX STATIONPWS-110RX1A電気製品は、安全のための注意事項を守らないと、火災や人身事故になることがあります。このオペレーションマニュアルには、事故を防ぐための重要な注意事項と製品の取り扱いかたを示してあります。このオペレーションマニュアルをよくお� …
  • Belkin

    OmniView

    (2 pages)
    The Belkin OmniView USB CAT5 Extender allows you to control your computer or KVM switch from up to 500 feet (150m) away. It is perfect for isolated server rooms, large server farms, secure systems, or test benches where the computer or KVM switch may be inaccessible to the user. The CAT5 Extender signicantly reduces cable bulk and simplies cable manage …
  • Draytek

    Vigor2930 Series

    (222 pages)
    Vigor2930 Series Dual-WAN Security Firewall User’s Guide Version: 1.0 Date: 2007/06/06 Copyright 2007 All rights reserved. This publication contains information that is protected by copyright. No part may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without written permission f …
  • Motorola

    WS2000 - Wireless Switch - Network Management Device

    (4 pages)
    SPECIFICATION SHEETSimple, cost-effective wired and wirelessnetworking for enterprise branch officesThe WS2000 Wireless Switch is a powerful all-in-one solution that simplifies and helps reduce the costs of managing wired and wireless (802.11a/b/g) networks in enterprise branch offices. The WS2000 provides best in class secure wireless and wired network s …

Comments, Questions and Opinions: