Manualios.com

Agilent Technologies Multiple Channel Controller 85330A Service Manual

  • Multiple Channel Controller 85330A Network Card
  • makuWWyVAKCQ.
  • Service Manual
  • PDF / Adobe Acrobat Reader
  • 166

Agilent Technologies Multiple Channel Controller 85330A Manual Online:

3.55, 1985 votes
Agilent Technologies Multiple Channel Controller 85330A User Manual
Agilent Technologies Multiple Channel Controller 85330A User Guide
Agilent Technologies Multiple Channel Controller 85330A Online Manual

Text of Agilent Technologies Multiple Channel Controller 85330A User Guide:

  • 85330A Multiple Channel Controller 6-15 Programming To Use Run-Time Control Mode Event Trigger If TTL triggering has been selected, the 85330A waits for an Event Trigger pulse before sending a measurement trigger to the receiver. If IMM triggering has been selected, the measurement trigger is sent to the receiver immediately. The trigger mode is selected using RUNT:EVEN:TR

  • Agilent Technologies Multiple Channel Controller 85330A, Index-2 85330A Multiple Channel Controller F fast data acquisition modes, A-12 fast source control, 6-8 frequency response measurements using IMM triggering, 6-12 front panel features, 4-11, 5-2 front panel operation, 5-2 G general information, 4-1 GPIB address, 1-8 adjustments, 9-23 GPIB commands ROUT DELay, 7-6 RUNTime, 7-7, 7-8, 7-9, 7-10, 7-11, 7-12, 7-13, 7-14, 7-15, 7-16 CONTroller, 7-8 GPIB softkey, 5-4 I IMM, 7-10 IMM triggering mode, 7-9 in case of difficulty, 8-11 INITiate, 7-10 installation 85330A fast source control, 1-2 installing 85330A, 1-2 choosing configuration, 1-2 L loading 85330A downloadable driver, 1-6 local control cable, 4-5 M manual oper

  • Agilent Technologies Multiple Channel Controller 85330A, 85330A Multiple Channel Controller 4-1 General Information 4 General Information In This Chapter • Product description • Required equipment • Supplied equipment and software • Agilent 85330A multiple channel controller characteristics • Front panel features • Rear panel features • AC power cord Figure 4-1 85330A System Overview

  • Agilent Technologies Multiple Channel Controller 85330A, 85330A Multiple Channel Controller A-1 Glossary A Glossary a1 The reference IF channel of the 8530A. This channel can be used as a phase lock reference or a test channel. a2 The test IF channel of the 8530A. This channel can be used as a phase lock reference or a test channel. AUT Antenna Under Test b1 One of three test channels of the 8530A. b2 One of three test channels of the 8530A. Channel Each switch module has either two or four possible switch positions, or channels. Controller The mode the 85330 operates in when it is controlling other 85330As. Refer to “RUNTime:CONTroller” command on page 7-8 and Chapter 6, “Programming” for more information. Direct Cont

  • Agilent Technologies Multiple Channel Controller 85330A, xiv 85330A Multiple Channel Controller Voltage Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Inputs/Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Output Trigger Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Pulse Receive and Cycle Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 Counter Pulse Delay Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 Measurement Busy Signal and Pulse Width Test . . . . . . . . . . . . . . 2-11 Verifying the Switch Control Unit . . . . .

  • Agilent Technologies Multiple Channel Controller 85330A, 85330A Multiple Channel Controller 6-3 Programming To Choose a Measurement Configuration To Choose a Measurement Configuration The measurement configuration you use depends on the type of measurement (CW or multiple-frequency) and the type of system (one-source or two-source system). One-source systems use the Agilent 8511A/B frequency converter, two-source systems use the Agilent 85309A frequency converter. Refer to Figure 6-1. How to Use the Figure Follow the flow chart from the top. Determine if your measurements are made with a single frequency (CW) or multiple frequencies. Proceed down the appropriate flow chart path. Proceed in this way until you ge

  • Agilent Technologies Multiple Channel Controller 85330A, 2-8 85330A Multiple Channel Controller Performance Verification Verifying the Multiple Channel Controller On the oscilloscope, press [CLEAR DISPLAY]. Set the [TIMEBASE] to {5 us/Div}. You should see a positive pulse, with an approximate width of 10 to 14 microseconds. 5. Connect the BNC cable to the SRC 2 TRIG connector on the multiple channel controller, and press: {SRC_2} On the oscilloscope, press [CLEAR DISPLAY]. You should see a positive pulse, with an approximate width of 10 to 14 microseconds. 6. Remove the BNC cable from the multiple cha

  • Agilent Technologies Multiple Channel Controller 85330A, 6-28 85330A Multiple Channel Controller Programming Programming Examples 1135 ENTER @Rec_data;Preamble,Data_bytes 1136 ENTER @Rec_data;Data_freq(*) 1137 NEXT N 1138 IF Passes<>Angle_pts THEN 1139 OUTPUT @Rec;”CLES;SING;” ! Have the receiver take another sweep. 1140 END IF 1141 NEXT Passes 1142 ! 1143 END

  • Agilent Technologies Multiple Channel Controller 85330A, 9-16 85330A Multiple Channel Controller Service Replaceable Parts Mainframe, Plug-in Cards The mainframe consists of a E1301B VXI mainframe. For information of replaceable parts for this mainframe, see the “Replaceable Parts” chapter of the Agilent E1301B Service Manual. Table 9-6 85330A Mainframe Replacement Parts Reference Designator Description Part Number Qty. A1 VXI Mainframe E1301B (Option 010) 1 A2 Digital I/O Card for VXI Size B E1330B 1 A3 85330-60002 Card 85330-60002 1 U2 A3U2 PAL for 85330A standard A3U2 PAL for 85330A H30 85330-80013 85330-80014 1 1 W1 A2-A3 Ribbon Cable Assembly 0.4

  • Agilent Technologies Multiple Channel Controller 85330A, 85330A Multiple Channel Controller 9-7 Service Theory of Operation of channel-address decode. The six channel-address bits allow unique addressing for switches up to a 64 throw switch. For the detailed theory of operation for the E1301B VXI mainframe, see the Service chapter in the Agilent E1301B Service Manual.

  • Agilent Technologies Multiple Channel Controller 85330A, 85330A Multiple Channel Controller 6-27 Programming Programming Examples 1089 OUTPUT @Rec;”TRGSEXT;HOLD;” ! SET TO EXTERNAL TRIGGER FOR CONTROLLED 1090 ! 1091 ! 1092 Set_85330a:! 1093 ! 1094 OUTPUT @Hp85330a;”*RST;” ! SOFT RESET 1095 ! 1097 OUTPUT @Hp85330a;”RUNT:EVEN:TRIG TTL;” ! Set the triggering. 1098 OUTPUT @Hp85330a;”RUNT:EVEN:COUN “;Angle_pts;”;” ! Angle increments 1099 ! 1100 OUTPUT @Hp85330a;”RUNT:TIME:EVEN 0,15000000;” ! timeout 1st point: 15 sec. 1101 OUTPUT @Hp85330a;”RUNT:TIME:EV

  • Agilent Technologies Multiple Channel Controller 85330A, 85330A Multiple Channel Controller 9-1 Service 9 Service Introduction This chapter explains the following topics: • Theory of Operation (how the multiple channel switching system works) • Recommended Test Equipment (the equipment required for servicing these instruments) • Service ❍ Troubleshooting (how to determine which part of the system is faulty) ❍ Replaceable Parts (how to identify and order parts) ❍ Assembly/Disassembly (how to remove and replace failed assemblies) ❍ Adjustments

  • Agilent Technologies Multiple Channel Controller 85330A, 85330A Multiple Channel Controller 9-19 Service Assembly and Disassembly Assembly and Disassembly CAUTION The assemblies used in the multiple channel controller system are static sensitive. Use anti-static techniques when performing the following procedures. For example, wear an anti-static ground strap and work at a station equipped with an anti-static mat. Mainframe For assembly and disassembly information on the E1301B VXI mainframe, see the Service chapter in the E1301B Service Manual. Disassembly

  • A-2 85330A Multiple Channel Controller Glossary Fast Data Acquisition Modes Fast Data Acquisition modes (also called “Fast CW” modes) refer to a set of similar 8530A measurement modes where: • All data processing except averaging is suspended to provide fastest possible measurement speed. • All data is stored in a 100,000 point FIFO data buffer, which can be read by a c

  • Agilent Technologies Multiple Channel Controller 85330A, 85330A Multiple Channel Controller 7-5 Remote Programming Command Reference Standard Command Reference Standard Command Reference The following pages describe 85330A multiple channel controller standard commands. ROUTe Subsystem Command Syntax :CLOSe port,(@switch address [,switch address]); :DELay <micro-seconds>; :CONTrol <data>; ROUTe:CLOSe Closes individual switch states in direct control only. The parameters are the switch port address, 1 or 2 and the switch address. The switch address is the concatenation of the SCU address and the channel. Examples are provided earlier in this chapter. This command can also be used to set t

  • Agilent Technologies Multiple Channel Controller 85330A, iv 85330A Multiple Channel Controller Appendix • Glossary of Terms - This glossary defines special terminology associated with this system. Words shown in bold text are defined in the glossary. Warranty Certification Agilent Technologies certifies that this product met its published specifications at the time of shipment from the factory. Agilent further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology (NIST, formerly NBS), to the extent allowed by the Institute

  • Agilent Technologies Multiple Channel Controller 85330A, 85330A Multiple Channel Controller 5-3 Manual Operation Softkey Map Softkey Map Figure 5-1 85330A Softkey Menu Map NOTE Refer to Chapter 3 of the Agilent 75000 Series B Mainframes Agilent E1300A and E1301A/B User’s Manual.

  • 85330A Multiple Channel Controller 9-23 Service Adjustments Figure 9-4 Positive/Negative-Edge EVENT TRIG jumpers 1. Remove the two screws that hold the E1330B board in place. 2. Remove the four screws that hold the 85330-60002 board in place. 3. Pull out the two boards at the same time. You can do this by pulling each one out a little at a time, until they are both removed. Place

  • Agilent Technologies Multiple Channel Controller 85330A, 9-14 85330A Multiple Channel Controller Service Replaceable Parts Replaceable Parts This section contains information for ordering replaceable parts for the multiple channel switch system. The replaceable parts include major assemblies and chassis hardware. Parts List Description The following tables show the location and identification of replaceable parts. The list provides the following information: 1. Reference designator: identifies the part in the accompanying figure. 2. Agilent part number. 3.

  • 85330A Multiple Channel Controller A-5 Glossary Standard System A “standard system” uses one 85330A with one or two switch control units, each with a two-throw or four-throw switch module. Remember that 85330A PORT 1 and PORT 2 are addressed independently. So: • If you have two SCUs, both can use the default SCU address (0). • You can use the default channel numbe

  • 85330A Multiple Channel Controller 3-1 Operator’s Check 3 Operator’s Check Purpose This operator’s check verifies that the Agilent 85330A can close switches, showing that the 85330A, switch control units, and switches are working. You can perform this check daily, or as desired. This is not a performance verification procedure (refer to Chapter 2, “Performance Verification” for mor

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Spirit XC8500 Instruction and user's manual spirit/xc8500-5YZ.pdf 03 Oct 2022 31 2.86 Mb
2 Clavia Nord Modular V3 Operation & user’s manual clavia/nord-modular-v3-AP1.pdf 25 Jun 2023 232 4.54 Mb
3 Plantronics CLARITY EXL-30 Declaration of conformity plantronics/clarity-exl-30-QIJ.pdf 16 Sep 2022 1
4 Samsung S24C230JL Operation & user’s manual samsung/s24c230jl-421.pdf 23 May 2023 77
5 Lightronics FXLD1036C4O Owners mnaul lightronics/fxld1036c4o-D72.pdf 14 Mar 2024 6
6 Rane SP 15 Operating and service manual rane/sp-15-R5C.pdf 08 Nov 2023 9 5.16 Mb

Similar Resources:

  • Xerox

    WNA-100 - Bridge

    (2 pages)
    Guide d’installation . Guida all’installazione . Installationshandbuch . Guía de instalación . Guia de instalaçãoInstallation Guidewireless network adapter4Copyright © 2007 by Xerox Corporation. All Rights Reserved.www.xerox.com/office/wna721P58810 Rev A132http://169.254.111.111Enter the adapter’s IP Address in your web browser, and then …
  • Agilent Technologies

    HDMP-3001

    (124 pages)
    Agilent HDMP-3001Ethernet over SONET Mapper ICDevice SpecificationData SheetTable of Contents1. Introduction............................................................................................... 51.1 Internal Functional Blocks .............................................................. 51.2 HDMP-3001 Features List ................................ …
  • Linksys

    WUSB54AG

    (2 pages)
    Model No.Product DataWirelessWUSB54AGThe easy way to connect your desktop or notebook to high-speed Wireless-A, -B, or -G networksUniversal wireless adapter connects your desktop or note-book to Wireless-A, -B, or -G networksWireless communi-cations are pro-tected by up to 128-bit data encryptionData rates up to 54Mbps when used with a USB 2.0 portEasy, no-t …
  • SEH

    ISD300-PoE

    (36 pages)
    Quick Installation Guide 1 Monday - ThursdayFriday8:00 a.m. to 4:45 p.m. and 8:00 a.m. to 3:15 p.m. (CET) ℡+49 (0)521 94226-44 @ [email protected] Spooling DeviceISD300-PoEQuick Installation GuideOverview [en]This Quick Installation Guide providesa brief description of the installationof …
  • Patton electronics

    2173

    (20 pages)
    USER MANUALMODEL 2173 CopperLINK™ High Speed Ethernet ExtenderSALES OFFICE(301) 975-1000TECHNICAL SUPPORT(301) 975-1007Part# 07M2173-UMRev. BRevised 8/31/10An ISO-9001CertifiedCompanyThis is a Class A device and is not intended for use in a residential environment. …
  • Cisco

    ONS 15454 Series

    (62 pages)
    CHAPTER 4-1Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.1 and Release 9.278-19418-014Error MessagesNote The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as …

Comments, Questions and Opinions: