Manualios.com

Aico New 160 Series 160 Series Product Manual

Aico New 160 Series 160 Series Manual Online:

4, 1927 votes
Aico New 160 Series 160 Series User Manual
Aico New 160 Series 160 Series User Guide
Aico New 160 Series 160 Series Online Manual

Text of Aico New 160 Series 160 Series User Guide:

  • Aico New 160 Series 160 Series, (68.52) X New 160 Series nowNew 160 Series now with REMOTE CONTROL with REMOTE CONTROL functionalityfunctionality New 160 Series now with REMOTE CONTROL functionality Product Guide for Smoke & Heat Alarms Ahead on Quality Ahead on Performance Ahead on Features Ahead on Quality Ahead on Performance Ahead on Features

  • Aico New 160 Series 160 Series, The Solution Provider for Smoke & Heat Alarm Installation Standards The Ei Range of Smoke Alarms from Aico offers the complete solution to meeting the new requirements of BS 5839: Pt.6: 2004 for Residential Fire Detection. Proven and reliable technology is combined with innovative product development to provide the best possible performance available in real fire situations. Various options are offered in order that specifiers and end users can select the ideal product for every individual installation with regard to the building and its occupants. All options offer value for money, unprecedente

  • Aico New 160 Series 160 Series, Residential Fire Detection & Regulations ... how do they affect me? What do Building Regulations Demand in New Build and Materially Altered Dwellings? Architects, builders and installers must comply with Building Regulations and install mains powered smoke alarms in new and materially altered dwellings. England & Wales Building Regulations Approved Document B (Fire Safety) minimum requirements are currently Grade D, LD3, but also defines that installation should be to BS 5839 Pt.6 and therefore Grade D, LD2 is recommended. Grade D, LD2 ● Mains alarms with battery back-up wired to a lighting circuit or a dedicated circuit ● Smoke ala

  • Aico New 160 Series 160 Series, Ionisation Alarms where should they be used? Ionisation type sensors are particularly sensitive to the almost invisible smoke produced by fast flaming fires. This makes them more liable to false alarm due to cooking fumes if sited in a hallway close to a kitchen. Ionisation alarms are less vulnerable to false alarms caused by dense tobacco smoke, excessive dust and insect ingress. The BS 5839: Pt.6: 2004 Standard recommends that ionisation alarms should not be used in hallways and landings, where there is a risk of

  • Aico New 160 Series 160 Series, Selection, Positioning, Wiring Smoke & Heat Alarms 5 SITING DIAGRAMS Simple Interconnect Wiring for all Mains Powered Smoke and Heat Alarms 140/160RC Series 140/160RC Series To mains power supply - e.g. lighting circuit or distribution board To other alarms in the system (as required) Live Neutral Interconnect Which Alarms to Fit Where Important Interconnection is vital to ensure the alarm is heard throughout the property by all occupants. Average two storey house Single storey dwelling Optical or Ionisation smoke alarm as best suited for the particular circumstances Optical smoke alarm Smoke or heat alarm as best suited for the particular circum

  • Innovative Design & Quality Features Ei's unique large volume optical smoke chamber & sophisticated electronics have a proven track record of reliability and high efficiency detection. Longevity and resistance to false alarms as well as reliable protection from electromagnetic interference has also been proven over the last 15 years. At 85dB(A) at 3 metres our alarms

  • Aico New 160 Series 160 Series, 7 Product Specifications Remote Control System Option ✔✔ Ionisation Sensor ✔✔✔ Optical Sensor ✔✔✔ Heat Sensor ✔✔✔ Mains Supply ✔✔✔✔ Lithium Rechargeable Cell Back-up ✔✔ ✔ Alkaline Battery Back-up ✔ Lithium Battery ✔ Interconnectable ✔✔ ✔ ✔ 85dB(A) @ 3m Sound Output ✔✔✔ Easi-fit System ✔✔ ✔ Test, Hush Feature ✔✔✔✔✔ Test, Hush and Fire Locate Feature ✔✔ Radio-Frequency Interconnect ✔✔ High Performance Ionisation Chamber ✔✔ ✔ Large Volume Optical Chamber ✔✔✔

  • Aico New 160 Series 160 Series, 8 The 160RC Series, Easi-fit mains powered smoke and heat alarms are our highest specification range, especially so when coupled to the RadioLINK system. Designed for the specifier, installer and end user demanding the very highest standards of safety, performance and reliability you'd expect from Europe's leading manufacturer of mains powered fire detection products. Almost all practical duty of care provisions are catered for. With no risk of casual back-up cell removal, the power supply is virtually guaranteed against any external threat to the energy supply. Risks of false alarms are minimised and installa

  • Aico New 160 Series 160 Series, COLOUR CODED PACKAGING FOR EASY RECOGNITION COLOUR CODED PACKAGING FOR EASY RECOGNITION BS 5446: Pt.1: 2000 Ei161RC Ionisation BS 5446: Pt.1: 2000 Ei166RC Optical 9 TEST Test all alarms from one convenient switch HUSH Any nuisance alarm can be quickly and easily silenced LOCATE Allows the source of the alarm to be identified. MAINS The Test function will not operate without mains power, CHECK providing a simple way to test the mains supply MANUAL CALL POINT MCP401RC Manual Call Point Surface Mount for use with all Ei mains alarms This simple remote

  • Aico New 160 Series 160 Series, 10 RadioLINK Wireless For use with 160RC Ser THE COMPLETE SOLUTION TO THE NEW BS 5839: Pt.6: 2004 REQUIREMENTS Interconnecting mains powered smoke alarms is essential to provide the earliest possible warning of a fire. Fire statistics show that the quicker occupants are alerted to a fire, the less risk of death or injury there is. Furthermore, property damage is also reduced. With RadioLINK, mains powered smoke alarms are interconnected by wireless signals rather than cabling. It's so much simpler, more convenient - and easier to change or extend as and when required. Code Description

  • Aico New 160 Series 160 Series, Interconnection ies Smoke & Heat Alarms RadioLINK SYSTEM CONTROL DEVICES Slide a 160RC Series alarm on to the Ei168RC base which will automatically activate the rechargeable back-up cells, and then repeat this procedure for all the alarms in the system. House code each alarm in the system. Easy to fit Ei411H Wireless Remote Control Switch ● When used in conjunction with RC alarms, with the Ei168RC RadioLINK base, the switch offers three vital remote control functions. ● TEST - Provides a full system test equivalent to pressing the Test button on all units simultaneously ● HUSH - Allows the silencing of any possi

  • Aico New 160 Series 160 Series, MAINS POWERED ALARMS WITH ALKALINE BATTERY BACK-UP Designed for applications where the budget is a key consideration and where maintenance is in the hands of the owner occupier or there is no requirement for lithium power cell back-up. The 140 Series provides an alkaline battery back-up instead of rechargeable cells. Further cost savings are possible through the innovative and totally unique Easi-fit technology, as there is no need to purchase additional wiring enclosures, mounting kits, leads or connectors. In a field where time is money, the fact that Easi-fit alar

  • Alarm Systems for the Deaf & Hearing Impaired People with hearing difficulties require a different approach to fire protection, as a conventional alarm sounder will not be sufficient for their needs. Aico's range of alarms for the deaf and hearing impaired are the only units currently available from an experienced smoke alarm manufacturer. They are also avai

  • Aico New 160 Series 160 Series, Low Voltage Smoke & Heat Alarms Other Smoke & Heat Alarms and Control In properties where there is a requirement to connect smoke and heat alarms to a low voltage security system, or Warden Call System, the Ei180 Series alarms can provide the ideal solution. 14 Surface Mount Kits enable easier installation of the alarms. Relays provide the option of signalling to almost any other device. Relays can be used to signal to: Warden Call Systems Strobes Sounders Door Closers Smoke Vents Other Fire Alarm Systems Code Description Ei181 10-30VDC Ionisation Smoke Alarm Ei184 10

  • Devices 15 NO ALARM - NO CHANCE! Carbon Monoxide or (CO), is a particularly insidious gas. It is a killer. The naked eye can't see it, it does not smell, it has no taste. The need for a reliable mains powered alarm that will operate even in the event of a mains failure is obvious. The Ei professional range includes fully featured product usually specified by Local Auth

Related Products and Documents (Smoke Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 GE ZISS480NXSS Datasheet ge/ziss480nxss-359.pdf 25 Oct 2023 2
2 Ahuja BTZ-7000 Operation manual ahuja/btz-7000-CWO.pdf 28 Jun 2022 20
3 JVC VN-V225VPU Specifications jvc/vn-v225vpu-751.pdf 13 Apr 2023 2
4 Majestic Appliances 17-2013 Owner's manual majestic-appliances/17-2013-44P.pdf 09 Jan 2024 18
5 Cooper Lighting IRIS RPN3MR Specification sheet cooper-lighting/iris-rpn3mr-17A.pdf 20 Dec 2022 2 0.14 Mb
6 DirecTV RC71 Manual  directv/rc71-181.pdf 24 Aug 2022 3

Similar Resources:

  • Notifier

    SDX-751TEM

    (4 pages)
    N600-05-00© System Sensor 2001I56-1320-0011INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR MODEL SDX-751TEMANALOGUE ADDRESSABLE MULTI-CRITERIA SMOKE SENSORBefore installing the sensor, please thoroughly read System Sensor’s wiring and installation manual, I56-407-XX, Guide for Proper Use of SystemSensor Smoke Detectors. This manual includes detailed inform …
  • Johnson Controls

    IR6003/7

    (6 pages)
    IR Oil Mist/Smoke DetectorFeatures• AutomaticSelfCalibration• Range=2-30metres• WeatherprooftoIP65• CertifiedIntrinsicallySafeEExibIIBT5• RobustDesign• HeavyDutyMountingBracketavailable• Independentbeamblockedoutput• Cleaningstatusoutput• Dual …
  • LST

    200 Series

    (1 pages)
    © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 [email protected] • WWW.LST.AT • ALL RIGHTS RESERVEDB501_DBL_LST_EN_0804.PDF • PAGE 1ABuilding Safety. Building Security.Detector Base Series 200B501/B501DGDescriptionSpecifi cationsThe Detector Base B501/B501DG is designed to ac-co …
  • Bosch

    Titanus Pro?Sens TP-1 A

    (12 pages)
    Bosch Sicherheitssysteme GmbH - 1 - F.01U.045.264 | de/en/fr | A6 | 2007.03 Installationshinweise Rauchansaugsystem TITANUS PRO⋅SENS® TP-1 A TITANUS PRO⋅SENS® TP-2 A Installation Instructions Aspirating Smoke Detector TITANUS PRO⋅SENS® TP-1 A TITANUS PRO⋅SENS® TP-2 A Instructions de mise en place Système aspirant de détection d’incendie TI …
  • Quell

    Q1300

    (16 pages)
    Smoke alarmInstallerʼs Manual240V Interconnectable Main Operated AlarmFor models: Q1300Thank you for purchasing Quell 240V hard-wired photoelectricsmoke alarm. Please read through our guide in full. Chubb Fire & Security Pty Limited recommends for maximumprotection that both ionisation and photo-electric (optical) smokealarms be installed. Ionisation se …
  • System Sensor

    i4 Series COSMO-2W

    (4 pages)
    SS-500-003 1 I56-3747-001Ri4 Series Combination Carbon Monoxide(CO)/Photoelectric Smoke DetectorCOSMO-2W (2-wire) and COSMO-4W (4-wire)INSTALLATION AND MAINTENANCE INSTRUCTIONS3825 Ohio Avenue, St. Charles, Illinois 601741-800-SENSOR2, FAX: 630-377-6583www.systemsensor.comNotice: This manual shall be left with the owner/user of this equipment.BEFORE INSTA …

Comments, Questions and Opinions: