Manualios.com

Siemens I-SURF Operation & User’s Manual

Siemens I-SURF Manual Online:

4.8, 2132 votes
Siemens I-SURF User Manual
Siemens I-SURF User Guide
Siemens I-SURF Online Manual

Text of Siemens I-SURF User Guide:

  • Siemens I-SURF, 1. About This Documentation 3 1. About This Documentation 1.1 Introduction This documentation describes the installation and operation of the Siemens ISDN Adapter and contains a lot of other interesting information on ISDN and on using your ISDN Adapter in conjunction with application programs. If the information in the README.TXT file on the installations diskettes (or CD) differs from the content of this documentation, please follow the instructions in README.TXT. 1.2 Where to find information in

  • Siemens I-SURF, Appendix 63 A3: ISDN S 0 Interface Pin Assignment ISDN S 0 interface pin assignment (RJ45 plug/jack) (CCITT I.430/ISO 8877) Pin Signal 1 Not used 2 Not used 3 STA (Sending A) 4 SRA (Receiving A) 5 SRB (Receiving B) 6 STB (Sending B) 7 Not used 8 Not used A4: Terminal Resistor for ISDN S 0 Interface The last jack on your ISDN S 0 bus must be terminated with two 100 ohm terminal resistors.

  • 6. Installation and Configuration under Windows 98 19 5. Confirm the location of the driver by clicking 'Next' again. The Hardware Wizard will now start updating the driver database, copying the ISDN Adapter driver to your hard disk. This process will take a bit of time; watch the progress indicator on your screen. 6. The last installation step requires that the

  • 11. Troubleshooting 56 Installation Installation does not start automatically No new hardware detected Is the ISDN Adapter connected to the PC? Properly connect the USB cable to the ISDN Adapter and reboot. Previous installation was interrupted Remove previous installation and reboot. Adapter already installed Does the ISDN Adapter appear in the network adapter list of the Devic

  • Siemens I-SURF, 7. Installation and Configuration under Windows 2000 25 5. Confirm the location found for the driver database by clicking 'Next' again. The Hardware Wizard will now start updating the driver database, copying the ISDN Adapter driver to your hard disk. This process will take a bit of time; watch the progress indicator for the various installation steps on your screen. 6. As the installation progresses, you will see a question concerning a digital signature that was not found. Simply continue the installation by clicking Yes.

  • Siemens I-SURF, 8. I-Surf USB Utilities 38 Single-clicking one of these icons opens a popup menu with the following selections: Command Description Log Opens the connection log, which contains logged data for all connections. Info Opens a dialog box containing information on the current connection. Exit Terminates the CAPI Monitor To automatically load the CAPI Monitor each time Windows is started, copy the CAPI Monitor program icon to the Windows Startup folder.

  • Siemens I-SURF, 11. Troubleshooting 59 Dial-up Network Dial-up Network shows “verifying user name and password” but then stops User account not valid Connection has been established. Are the , user ID and password valid? Consult dial-up server administrator for help. Dial-up Network does not show “verifying user name and password” and stops Wrong phone number Is the phone number of dial-up server correct? Consult dial-up server administrator for help. Dial-up Network shows “logging onto the network” but then stops Incorrect n

  • 11. Troubleshooting 54 11.3 Dial-Up Network If you wish to use the ISDN Adapter with the Windows Dial-Up Network, you will first have to configure a connection. Once a connection is configured, click the connection icon to establish the connection. The current connection status will be displayed in the status window. Error messages indicating possible causes of the error will be displayed in case

  • Siemens I-SURF, 7. Installation and Configuration under Windows 2000 26 7. Select the language and click ‘OK‘ . 8. Once the software installation is completed, the installation of the I-Surf ISDN Utilities (ISDN Tools) is started automatically. Click 'Next'.

  • Siemens I-SURF, 2. Introduction 6 2.3 Deliverables The following components are supplied with your I-SURF USB: 1 I-SURF USB box 1 ISDN S 0 connection cable with RJ45/IAE plugs (not illustrated) 1 USB cable for connecting to the PC 1 CD ROM with drivers for Windows 98 and Windows 2000, RVS-COM Lite and online documentation (not illustrated) 1 set of operating instructions (not illustrated) USB box USB cable 2.4 Instructions for care Wipe the device with a damp cloth or with an antistatic cloth. Do not use cleaning agents. Do not use a dry cloth, because then you run the ris

  • Siemens I-SURF, Appendix 62 A2: CAPI 2.0 Error Messages Number (hex) Description 0x1001 Error in API_REGISTER 0x1002 Invalid application ID 0x1003 Invalid message 0x1004 Invalid command or subcommand 0x1005 Queue full 0x1006 Queue empty 0x1007 Queue overflow 0x1008 Deinstallation error 0x2001 Invalid controller 0x2002 Invalid PLCI 0x2003 Invalid NCCI 0x2004 Invalid type 0x3101 Error in B channel 0x3102 Error in info mask 0x3103 Error in MSN service mask 0x3104 Error in SI service mask 0x3105 Invalid protocol layer 2 0x3106 Invalid DLPD 0x3107 Invalid protocol layer 2 0x3108 Invalid NCPD 0x3109 Invalid NCPIs 0x3201 General controller error 0x3202 L

  • Siemens I-SURF, 3. Basics of ISDN 9 3. Basics of ISDN 3.1 What is ISDN ? ISDN is an abbreviation for Integrated Services Digital Network, a modern communications network. ISDN lets you enjoy all the many facets of electronic communications. You can surf the Internet, balance your accounts using home banking services, or remotely connect to your company's computer network. 3.2 What Does ISDN Have to Offer? The ISDN telecommunications network offers subscribers digital payload channels (B channels) with a maximum transfer speed of 64 kbps. The most important improvement of ISDN over conventional analog public communications networks is that ISDN suppo

  • Siemens I-SURF, 6. Installation and Configuration under Windows 98 21 After the system has been restarted, your ISDN Adapter is ready to use. The installation program will have installed the following components on your system: NDIS WAN Miniport Treiber CAPI driver ISDN Utilities program group ISDN configuration wizard CAPI tray (B channel usage indicator) Loopback test program Uninstall Your PC’s Device Manager will show two new devices: USB ISDN Adapter WAN-Miniport + Capi 2.0 USB ISDN Adapter This is where you find the Device Manager: My Computer / Control Panel / System / Device Manager

  • Siemens I-SURF, 3. Basics of ISDN 10 3.3 ISDN Access Converting a standard analog phone line to ISDN has become very simple these days. The existing phone line can simply be changed over to ISDN at a specified point in time. Since ISDN uses existing telephone cables, the telephone company does not need to run any new lines to your house or office. At the end of the phone line you need an NTBA (network terminator/bus adapter) to convert the two-wire signals for the four-wire ISDN S 0 bus. 3.4 Features ISDN offers a great variet

  • Siemens I-SURF, 7. Installation and Configuration under Windows 2000 28 11. This concludes the installation of the I-Surf ISDN Utilities. Click ‘Finish‘ . The installation program will have installed the following components on your system: NDIS WAN Miniport driver CAPI driver I-Surf USB Utilities program folder ISDN configuration wizard CAPI tray (B channel usage indicator) Loopback test program Uninstall

  • Siemens I-SURF, 10. Internet access 51 10.3 Online Services You can use your ISDN Adapter to access a variety of online services. Online services offer a broad spectrum of information services that is continuously being updated. Online services offer up-to-date information, the way newspapers and magazines have done, but by an electronic route. Learn all you can about what the different services have to offer before signing up with the service most suitable for your needs. Major online services usually offer their own software packages you can use to access thse services. The software packages of most major online services include CAPI support. You may therefore select the CAPI as access mode instead of a m

  • Siemens I-SURF, 8. I-Surf USB Utilities 35 8. I-Surf USB Utilities When you have installed your software and restarted your computer, you will find a new icon for the I-Surf ISDN Utilities program folder on your Windows desktop. (It is possible that this icon is covered by another window.) Open the program folder by clicking/double-clicking it. It contains software components described separately in the following sections.

  • Siemens I-SURF, 7. Installation and Configuration under Windows 2000 23 7. Installation and Configuration under Windows 2000 7.1 Automatic Installation 1. If a device driver or application software are already installed for an ISDN Adapter, this driver or software (such as RVS-COM) should be uninstalled as per its manufacturer’s instructions in order to ensure proper installation of the new software. If you want to update a Windows 98 installation that has ISDN software installed to Windows 2000, you should first unin

  • 7. Installation and Configuration under Windows 2000 30 7.2 Deactivation (Hot Plug) and Configuration nder Windows 2000, you may deactivate your ISDN Adapter without uninstalling the device driver software. This allows you, for example, to use your ISDN Adapter on a different computer temporarily. 1. The system task bar contains the following icon: Left-click this icon. 2. The Unplug or Eje

  • Siemens I-SURF, 7. Installation and Configuration under Windows 2000 27 9. Enter or select a destination folder for the I-Surf ISDN Utilities (ISDN Tools). Click 'Next'. 10. Select an existing program folder where the I-Surf ISDN Utilities icons are to be installed. To install the I-Surf ISDN Utilities icons in a new program folder, enter the name for the new folder instead. Click Next.

  • Siemens I-SURF, 11. Troubleshooting 55 11.5 Check Liste Effect Cause Check Action Connecting I-Surf USB Operating system does not recognize I-Surf USB when it is plugged in Incorrect operating system Are you using Windows 98 or Windows 2000? Install Windows 98 or Windows 2000. USB controller deactivated in the BIOS Activate the USB controller in the BIOS. USB controller not correctly installed within the operating system. Has the USB Controller been properly installed in the Device Manager of the operating system? Use the

  • Siemens I-SURF, 10. Internet access 47 4. Select the appropriate settings for the protocols supported by the server (here: TCP/IP): Limiting the number of protocol will speed up the connection process. Now you can connect to the server by double-clicking on the connection icon.

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 AccuEnergy AcuMesh Wireless RS485 Manual  accuenergy/acumesh-wireless-rs485-8GF.pdf 01 Apr 2023 20
2 Rotel RMB-1506 Specifications rotel/rmb-1506-BEB.pdf 01 Aug 2023 1 0.2 Mb
3 Strong SRT ANT 12 User manaul strong/srt-ant-12-G82.pdf 01 Aug 2022 7 0.64 Mb
4 Garmin GPSMAP 200 Owner's manual garmin/gpsmap-200-648.pdf 10 Jan 2024 60 1.6 Mb
5 HP 8050 PhotoSmart Inkjet Features manual hp/8050-photosmart-inkjet-7G4.pdf 16 Mar 2023 7 0.26 Mb
6 Tesco VC010 Operation & user’s manual tesco/vc010-CG1.pdf 01 Oct 2022 6

Similar Resources:

  • SMC Networks

    EZ CARD 1255TX-1

    (2 pages)
    1. 2. 3. 1.SMC1255TX-1SMC1255TX-1EZ Card™ 10/10010/100 Mbps Fast Ethernet PCI Cardwith Wake-On-LANQuick Installation GuideInstallationskurzanleitungManual de instalación rápidaGuide d’installation rapideBeknopte installatiehandleidingManual de Instalação RápidaSnabbinstallationshandbokEEnngglliisshh11.. HHaarrddwwaarree IInnssttaallllaattiio …
  • Jabra

    8110

    (8 pages)
    GN 8110 USBUser Guide 77 Northeastern Blvd. • Nashua, NH 03062 USA1-800-826-4656 • www.gnnetcom.com54-0137APrinted in ChinaJanuary 2001System RequirementsThe GN8110-USB requires the following operating systems:• Windows 98 SE (Second Edition)• Windows 2000• Windows ME (Millennium Edition)• Macintosh OS 9.0.4 or greater.You must have an available …
  • TYAN

    Thunder S2462

    (2 pages)
    www.tyan.comS2462Thunder K7Tyan's Thunder K7 is the world's first dual-processor platform for the AMD Athlon MPprocessor. This high-quality, feature-richsystem board provides cutting-edgeperformance for today's most demandingworkstation and server applications, andincludes powerful connectivity andmanagement features. The Thunder K7features th …
  • Renesas

    Direct Dummy IC M3T-DIRECT100S

    (4 pages)
    ( 1 / 4 )M3T-DIRECT100SDirect Dummy IC for 100-pin 0.65-mm-pitch QFPUser's ManualKeep safety first in your circuit designs!• Renesas Technology Corporation and Renesas Solutions Corporation put the maximum effort into making semiconductor products better and morereliable, but there is always the possibility that trouble may occur with them. Trouble wi …
  • Fostex

    9046

    (1 pages)
    TRAINING GUIDE: MODEL 9046 DVD OPTION DESCRIPTION The Model 9046 is to be installed in D2424 secondary drive to archive data from the primary drive. A DVD-RAM disk can archive 4.7GB of data on each side for a total storage capacity of 9.4GB. Recorded audio data on the primary hard drive can also be exported to / imported from the DVD-RAM as .WAV file …
  • Campbell

    SC32B

    (14 pages)
    INSTRUCTION MANUAL Issued: 17.3.14 Copyright © 1987-2013 Campbell Scientific Inc. Printed under Licence by Campbell Scientific Ltd. CSL 482 SC32B Optically Isolated RS-232 Interface …

Comments, Questions and Opinions: