Text of EarthLinked HCM-1836C User Guide:

  • EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Copyright 2015 Earthlinked Technologies, Inc Hybrid Cooling Module Models HCM-1836C and HCM-4272C Installation Manual for R-410A CONTENTS PAGE Pre-Installation 3 Installation 5  Placement 5  Refrigerant Connections 7  Electrical and Start-Up 9  Fan Speed Control 10

  • EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 2 Disclaimer The EarthLinked ® Hybrid Cooling Module is sold as a system component part and must be properly sized and matched to the system compressor unit to provide the intended performance and safe operation of the system. This component must be installed and serviced by an ETI authorized technician. Installation and service must be made in accordance with the instructions set forth within this manual. Failure to provide installation and service by an E

  • HCM-410CP-IM (12/15) Page 3 Pre-Installation This Hybrid Cooling Module (HCM) is sold as a system component and must be properly matched with the compressor unit to provide the anticipated performance and safe operation of the system. The table below lists the properly matched EarthLinked ® Hybrid Cooling Module models with EarthLinked ® compressor unit mo

  • EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 4 The dimensions data for the Hybrid Cooling Module is shown in Figure 1. Dimensions, Inches Connections Tube, OD, inches Sound, dB(A) Net Weight, Lbs Coil H W D Inlet Outlet Rows Fins/inch Face Area, Sq Ft 25-7/8 36 17-3/8 7/8 7/8 52.0 95 2 15 7.0 Fan Electrical Type CFM RPM Dia., inches Power Fan HP Fan FLA Min Voltage Swept 1,800 810 20 230-1-60 1/6 1.0 207 Figure 1. Hybrid Cooling Module Dimensions and Data

  • EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 5 Installation – Hybrid Cooling Module Placement The Hybrid Cooling Module unit is placed as shown in Figure 2 relative to other components in the EarthLinked ® system. The Hybrid Cooling Module is located outdoors and will be connected to the refrigerant line set (vapor tube) outside the building. Figure 2. Hybrid Cooling Module Placement in EarthLinked ® System Location Requirements for the Hybrid Cooling Module: 1. Within 20 Feet of the earth loop line set. Minimize refrigerant line lengths. 2. No more than 20 feet higher than the earth loop manifolds. 3. With proper clearances around the unit:  24 inches

  • HCM-410CP-IM (12/15) Page 6 5. On a solid, level mounting pad. The mounting pad should extend a minimum of 2 inches beyond the cabinet size of the Hybrid Cooling Module. The minimum pad size is to be 22 inches by 46 inches. The pad should NOT be in contact with or be an integral part of the building foundation. The following DiversiTech Pads (or their equivalent) are

  • EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 7 Installation – Refrigerant Connections The Hybrid Cooling Module has two refrigerant connections on the service side of the unit as shown in Figure 1. The connections are the same size as each other. Each connection is identified with a label saying “Compressor” or “Earth loops”. Check Figure 1 and the table on page 3 to determine coupling sizes to match the line set vapor tube size. The refrigerant connections have caps brazed on at the factory. They should be un-brazed at the time that tubing is to be connected to the Hybrid Cooling Module. After locati

  • EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 8 Figure 4. Top View of Line Set Connections All refrigerant piping joints and connections in the EarthLinked® heating and cooling system, including the Hybrid Cooling Module, line sets and earth loop system are to be brazed with 15% silver content brazing alloy, utilizing the NITROGEN BRAZING PROCESS.

  • EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 9 Installation – Electrical and Start-Up 1. After turning “OFF” power to all EarthLinked ® and field supplied system components at the appropriate breakers remove the Hybrid Cooling Module control box access panel. 2. Connect appropriately sized line voltage wires and ground wire to the Hybrid Cooling Module, as shown in Figure 5. Figure 5. Hybrid Cooling Module Field Wiring 3. The Hybrid Cooling Module contains a pressure actuated fan speed control that has been factory set for a pre-determined R-410A system condensing pr

  • EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 10 Installation - Fan Speed Control The Hybrid Cooling Module (HCM) is equipped with a variable fan speed control that varies the speed of the fan as a direct function of the system condensing pressure. When the system is operating in cooling mode and the compressor unit turns on, the Hybrid Cooling Module fan speed will increase as condensing pressure increases. The fan will reach full speed at the factory- set condensing pressure. The system pressure setting and associated condensing temperature for full speed fan has been factory-set and is shown in Figure 6. Factory Setting f

  • EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 11 Figure 7. Field Adjustment Procedure After adjustment has been made, install the sealing plug and replace and fasten the control panel cover prior to restoring power to the Hybrid Cooling Module. The Hybrid Cooling Module does not operate in heating mode.

More Instructions:

DOWNLOAD

Related Products and Documents (Freezer):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Samsung SGH-T759 Operation & user’s manual samsung/sgh-t759-DUC.pdf 27 May 2023 259 8.15 Mb
2 StagePro SP LC 10 W Owner's manual stagepro/sp-lc-10-w-594.pdf 14 Mar 2023 69
3 AOC 2219V1 Specification sheet aoc/2219v1-GD4.pdf 25 Jun 2023 1 0.28 Mb
4 Apple External Video Connector Getting started apple/external-video-connector-AXZ.pdf 16 Mar 2023 63 1.39 Mb
5 Duerkopp Adler 971 Spare parts duerkopp-adler/971-YPH.pdf 04 Apr 2024 42 8.83 Mb
6 Freestyle FS84951 Operation & user’s manual freestyle/fs84951-CCE.pdf 28 Dec 2023 14 0.8 Mb

Similar Resources:

  • Phcbi

    MDF-DU702VHA

    (60 pages)
    MDF-DU702VHAMDF-DU502VHAPlease read the operating instructions carefully before using this product, and keep the operating instructions for future use. See page 58 for all model numbers. Operating Instructions Ultra-Low Temperature Freezer MDF-DU702VHA …
  • U-Line

    3036RRGLS-00B

    (31 pages)
    USER GUIDESAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICEModular 3000 Series • 3036RRGL • 36" Glass Door RefrigeratorRIGHT PRODUCT. RIGHT PLACE. RIGHT TEMPERATURE. SINCE 1962. …
  • Turbo Air

    TSD-27CF

    (26 pages)
    ISSUED BY: REVIEWED BY: REVISION 2.0 CHEST FREEZER Model : TSD-27CF TSD-27CF Specification: Subject to change without notice. SPECIFICATION TSD-27CF Classification Direct Cool, Manual Defrost, Tropical Power Source 115VAC, 60 Hz. Volume 138 Liters (4.9 cu.ft) Rated Current 2.0 Amp. Rated Power Input 13 …
  • Hussmann

    IMPACT LWU

    (6 pages)
    CACGCEEDDEFBDP/N 0395741_JMerchandisers®LWUTechnical Data SheetP/N 0395741_JNSF®CertifiedFebruary 2007Item Part # Description Wiring Item #FAN ASSEMBLIES AND THERMOSTATSA. 4W Fan Assembly (1)0392457 Fan Motor, Standard (MO.4410101)0409511 Front & Rear — Fan Bladeembossing toward motor (FB.0409511)0409513 End Compartment — Fan Bladeembossing towar …
  • LaboGene

    SCANVAC CoolSafe100-9 PROSuperior XS

    (20 pages)
    Code 9 9.900.900.763 1/19 U:\QA\Manualer\Arkiv\Manuals- Labogene-Origio-GKO\Manualer-WORD\ScanVac\CoolSafe XS XL Usermanual-Rev A5.docx Instruction Manual CoolSafe100-9 PRO Superior XS CoolSafe 95-15 PRO Superior XL © Copyright 2012 LaboGene ApS Industri …
  • Logik

    L60CW14E

    (68 pages)
    Installation /Instruction ManualFridge FreezerInstallasjons-/InstruksjonsmanualKombiskap Kjøl-FrysInstallation-/InstruktionsbokKyl FrysAsennus/KäyttöopasJääkaappipakastinInstallations-/BrugervejledningKøleskab FryserGBNOSEFIDKL60CW14EL60CW14E_IB_5L_140512_grace.indb 1 12/5/14 5:12 pm …

Comments, Questions and Opinions: