EarthLinked HCM-1836C Installation Manual
|
EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Copyright 2015 Earthlinked Technologies, Inc Hybrid Cooling Module Models HCM-1836C and HCM-4272C Installation Manual for R-410A CONTENTS PAGE Pre-Installation 3 Installation 5 Placement 5 Refrigerant Connections 7 Electrical and Start-Up 9 Fan Speed Control 10
EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 2 Disclaimer The EarthLinked ® Hybrid Cooling Module is sold as a system component part and must be properly sized and matched to the system compressor unit to provide the intended performance and safe operation of the system. This component must be installed and serviced by an ETI authorized technician. Installation and service must be made in accordance with the instructions set forth within this manual. Failure to provide installation and service by an E
HCM-410CP-IM (12/15) Page 3 Pre-Installation This Hybrid Cooling Module (HCM) is sold as a system component and must be properly matched with the compressor unit to provide the anticipated performance and safe operation of the system. The table below lists the properly matched EarthLinked ® Hybrid Cooling Module models with EarthLinked ® compressor unit mo
EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 4 The dimensions data for the Hybrid Cooling Module is shown in Figure 1. Dimensions, Inches Connections Tube, OD, inches Sound, dB(A) Net Weight, Lbs Coil H W D Inlet Outlet Rows Fins/inch Face Area, Sq Ft 25-7/8 36 17-3/8 7/8 7/8 52.0 95 2 15 7.0 Fan Electrical Type CFM RPM Dia., inches Power Fan HP Fan FLA Min Voltage Swept 1,800 810 20 230-1-60 1/6 1.0 207 Figure 1. Hybrid Cooling Module Dimensions and Data
EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 5 Installation – Hybrid Cooling Module Placement The Hybrid Cooling Module unit is placed as shown in Figure 2 relative to other components in the EarthLinked ® system. The Hybrid Cooling Module is located outdoors and will be connected to the refrigerant line set (vapor tube) outside the building. Figure 2. Hybrid Cooling Module Placement in EarthLinked ® System Location Requirements for the Hybrid Cooling Module: 1. Within 20 Feet of the earth loop line set. Minimize refrigerant line lengths. 2. No more than 20 feet higher than the earth loop manifolds. 3. With proper clearances around the unit: 24 inches
HCM-410CP-IM (12/15) Page 6 5. On a solid, level mounting pad. The mounting pad should extend a minimum of 2 inches beyond the cabinet size of the Hybrid Cooling Module. The minimum pad size is to be 22 inches by 46 inches. The pad should NOT be in contact with or be an integral part of the building foundation. The following DiversiTech Pads (or their equivalent) are
EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 7 Installation – Refrigerant Connections The Hybrid Cooling Module has two refrigerant connections on the service side of the unit as shown in Figure 1. The connections are the same size as each other. Each connection is identified with a label saying “Compressor” or “Earth loops”. Check Figure 1 and the table on page 3 to determine coupling sizes to match the line set vapor tube size. The refrigerant connections have caps brazed on at the factory. They should be un-brazed at the time that tubing is to be connected to the Hybrid Cooling Module. After locati
EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 8 Figure 4. Top View of Line Set Connections All refrigerant piping joints and connections in the EarthLinked® heating and cooling system, including the Hybrid Cooling Module, line sets and earth loop system are to be brazed with 15% silver content brazing alloy, utilizing the NITROGEN BRAZING PROCESS.
EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 9 Installation – Electrical and Start-Up 1. After turning “OFF” power to all EarthLinked ® and field supplied system components at the appropriate breakers remove the Hybrid Cooling Module control box access panel. 2. Connect appropriately sized line voltage wires and ground wire to the Hybrid Cooling Module, as shown in Figure 5. Figure 5. Hybrid Cooling Module Field Wiring 3. The Hybrid Cooling Module contains a pressure actuated fan speed control that has been factory set for a pre-determined R-410A system condensing pr
EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 10 Installation - Fan Speed Control The Hybrid Cooling Module (HCM) is equipped with a variable fan speed control that varies the speed of the fan as a direct function of the system condensing pressure. When the system is operating in cooling mode and the compressor unit turns on, the Hybrid Cooling Module fan speed will increase as condensing pressure increases. The fan will reach full speed at the factory- set condensing pressure. The system pressure setting and associated condensing temperature for full speed fan has been factory-set and is shown in Figure 6. Factory Setting f
EarthLinked HCM-1836C, HCM-410CP-IM (12/15) Page 11 Figure 7. Field Adjustment Procedure After adjustment has been made, install the sealing plug and replace and fasten the control panel cover prior to restoring power to the Hybrid Cooling Module. The Hybrid Cooling Module does not operate in heating mode.
DOWNLOAD |
Samsung SR-608EV Freezer Owner's instructions manual
SR-608EV |
Liebert Series 300 Freezer Installation, operation and maintenance manual
Series 300 |
Electrolux TF422 Freezer User handbook manual
TF422 |
Liebherr G 33 910 Freezer Operating instructions manual
G 33 910 |
Kuppersbusch IKEF 308-5Z3 Freezer Operating instructions manual
IKEF 308-5Z3 |
EarthLinked HWM-1836 Freezer Installation, operation & maintenance manual
HWM-1836 |
Black & Decker bdv212f Freezer Manual
bdv212f |
Kenwood KFC60B15 Freezer Installation instructions manual
KFC60B15 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Samsung | SGH-T759 | Operation & user’s manual | samsung/sgh-t759-DUC.pdf | 27 May 2023 | 259 | 8.15 Mb |
2 | StagePro | SP LC 10 W | Owner's manual | stagepro/sp-lc-10-w-594.pdf | 14 Mar 2023 | 69 | |
3 | AOC | 2219V1 | Specification sheet | aoc/2219v1-GD4.pdf | 25 Jun 2023 | 1 | 0.28 Mb |
4 | Apple | External Video Connector | Getting started | apple/external-video-connector-AXZ.pdf | 16 Mar 2023 | 63 | 1.39 Mb |
5 | Duerkopp Adler | 971 | Spare parts | duerkopp-adler/971-YPH.pdf | 04 Apr 2024 | 42 | 8.83 Mb |
6 | Freestyle | FS84951 | Operation & user’s manual | freestyle/fs84951-CCE.pdf | 28 Dec 2023 | 14 | 0.8 Mb |
Phcbi
MDF-DU702VHAMDF-DU502VHAPlease read the operating instructions carefully before using this product, and keep the operating instructions for future use. See page 58 for all model numbers. Operating Instructions Ultra-Low Temperature Freezer MDF-DU702VHA
…
MDF-DU702VHA(60 pages) |
U-Line
USER GUIDESAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICEModular 3000 Series • 3036RRGL • 36" Glass Door RefrigeratorRIGHT PRODUCT. RIGHT PLACE. RIGHT TEMPERATURE. SINCE 1962.
…
3036RRGLS-00B(31 pages) |
Turbo Air
ISSUED BY: REVIEWED BY: REVISION 2.0 CHEST FREEZER Model : TSD-27CF TSD-27CF Specification: Subject to change without notice. SPECIFICATION TSD-27CF Classification Direct Cool, Manual Defrost, Tropical Power Source 115VAC, 60 Hz. Volume 138 Liters (4.9 cu.ft) Rated Current 2.0 Amp. Rated Power Input 13 …
TSD-27CF(26 pages) |
Hussmann
CACGCEEDDEFBDP/N 0395741_JMerchandisers®LWUTechnical Data SheetP/N 0395741_JNSF®CertifiedFebruary 2007Item Part # Description Wiring Item #FAN ASSEMBLIES AND THERMOSTATSA. 4W Fan Assembly (1)0392457 Fan Motor, Standard (MO.4410101)0409511 Front & Rear — Fan Bladeembossing toward motor (FB.0409511)0409513 End Compartment — Fan Bladeembossing towar …
IMPACT LWU(6 pages) |
LaboGene
Code 9 9.900.900.763 1/19 U:\QA\Manualer\Arkiv\Manuals- Labogene-Origio-GKO\Manualer-WORD\ScanVac\CoolSafe XS XL Usermanual-Rev A5.docx Instruction Manual CoolSafe100-9 PRO Superior XS CoolSafe 95-15 PRO Superior XL © Copyright 2012 LaboGene ApS Industri …
SCANVAC CoolSafe100-9 PROSuperior XS(20 pages) |
Logik
Installation /Instruction ManualFridge FreezerInstallasjons-/InstruksjonsmanualKombiskap Kjøl-FrysInstallation-/InstruktionsbokKyl FrysAsennus/KäyttöopasJääkaappipakastinInstallations-/BrugervejledningKøleskab FryserGBNOSEFIDKL60CW14EL60CW14E_IB_5L_140512_grace.indb 1 12/5/14 5:12 pm
…
L60CW14E(68 pages) |
Gira Intercom System 2551 20#BNW97E: 2551 20 Intercom System Installation and operating instructions manual 2551 20, 20 |
Carson Remote Control Reflex Wheel Ultimate Touch 2.4gCarson Reflex Wheel Ultimate Touch 2.4g User Guide (Doc Type: Remote Control Instruction manual) Reflex Wheel Ultimate Touch 2.4g, 96 |
NCR Touch terminals P1535Touch terminals Quick reference manual (NCR P1535) P1535, 2 |
Polaroid Film Camera Splash IISplash II (Film Camera ePDF Guide, #B12JYJ) Splash II, 2 |
Reer Security Sensors JANUS#469CL3 JANUS: Reer Security Sensors Owner Documentation JANUS, 4 |
Sony Monitor GDM-F500#M298B1 GDM-F500: Sony Monitor Owner Documentation GDM-F500, 60 |
Electra Oven EL 303EL 303 Installation and user manual - U8KE82 EL 303, 28 |
Lenovo Server ThinkServer TS430Operation & user’s manual for Lenovo ThinkServer TS430 Server ThinkServer TS430, 222 |
GlassCrafters Other Equalis seriesInstallation instructions manual for GlassCrafters Equalis series Other Equalis series, 16 |
Acorn Desktop Archimedes 305Archimedes 305 (Desktop ePDF User Guide, #HAE1H6) Archimedes 305, 23 |
IKEA Indoor Furnishing FLYTTA KITCHEN CART 38 5/8X22 1/2"#6QR86P FLYTTA KITCHEN CART 38 5/8X22 1/2": IKEA Indoor Furnishing Owner Documentation FLYTTA KITCHEN CART 38 5/8X22 1/2", 4 |
Riccar Vacuum Cleaner 1800Owner's manual for Riccar 1800 Vacuum Cleaner 1800, 14 |