Electronics Line EL-4703, Wireless Supervisor Photoelectric Smoke Detector 2 GENERAL DESCRIPTION Electronics Line's smoke detector is single station, photoelectric smoke detector with a built-in supervised wireless transmitter. When sufficient smoke is detected, or the test feature is operated, the detector will sound its alarm horn and the transmitter will send an ALARM message. The Alarm output in the receiver will remain activated until the alarm condition clears. The smoke alarm base lock discourages unauthorized removal of the smoke alarm by requiring a screwdriver to remove the alarm from the bas
Wireless Supervisor Photoelectric Smoke Detector 3 EN SELECTING A LOCATION Smoke detectors should be installed in accordance with the NFPA Standard 74 (National Fire Protection Association, Batterymarch Park, Quincy, MA 02169). For complete coverage in residential units, smoke detectors should be installed in all rooms, halls, storage areas, basements, and atti
Electronics Line EL-4703, Wireless Supervisor Photoelectric Smoke Detector 4 ♦ If ceiling mounting is not possible and wall mounting is permitted by your local and state codes, put wall-mounted detectors between 4 and 6 inches (10 ~ 15 cm) from the ceiling, also see Figure 4. ♦ If some of your rooms have sloped, peaked, or gabled ceilings, try to mount detectors 3 feet (0.9 meter) measured horizontally from the highest point of the ceiling as shown in Figure 5. CAUTION: (As required by the California State Fire Marshall) “Early warning fire
Electronics Line EL-4703, Wireless Supervisor Photoelectric Smoke Detector 5 EN Where to Install Your Smoke Detectors in Mobile Homes and RVs Mobile homes and RVs built after about 1978 were designed and insulated to be energy-efficient. In mobile homes and RVs built after 1978, smoke detectors should be installed as described above. Older mobile homes and RVs may have little or no insulation compared to current standards. Outside walls and roofs are often made of non-insulated metal, which can transfer thermal energy flow from outdoors. This makes the air right next to them hotter or colder than the rest of the insid
Electronics Line EL-4703, Wireless Supervisor Photoelectric Smoke Detector 6 ♦ In very cold or very hot areas, including unheated buildings or outdoor rooms. If the temperature goes above or below the operating range of smoke detector, it will not work properly. The temperature range for your smoke detector is 4°C to 38°C (40°F to 100°F). ♦ In very dusty or dirty areas, dirt and dust can build up on the detector's sensing chamber, to make it overly sensitive. ♦ Additionally, dust or dirt can block openings to the sensing chamber and keep the detector from sensing smoke. ♦ Near fresh air vents or very drafty areas like air conditioners, heaters or fans. Fresh ai
Electronics Line EL-4703, Wireless Supervisor Photoelectric Smoke Detector 7 EN INSTALLATION The smoke detector is to be mounted on the ceiling or on the wall, if necessary. Since the smoke detector is a single-station type, it cannot be linked to other detectors. WARNING: Do not connect the smoke detectors to any other alarm or auxiliary device. Connecting anything else to this detector will prevent it from working properly. Read the “Where To Install Your Smoke Detector” and “Where Not To Install Your Smoke Detec
Electronics Line EL-4703, Wireless Supervisor Photoelectric Smoke Detector 8 Mounting a Detector ♦ Select the installation location. ♦ Remove locking pin securing the mounting bracket to the unit (see Figure 7). ♦ Remove the mounting bracket from the unit by rotating it counterclockwise. ♦ Use the bracket as a template for marking the mounting holes ♦ Using an appropriate drill, drill two holes at the marks and insert anchors. ♦ Using screws (supplied) attach the bracket to the wall as in
Electronics Line EL-4703, Wireless Supervisor Photoelectric Smoke Detector 9 EN RED INDICATOR When the red LED indicator (see Figure 9) flashes once in 30 seconds, it indicates the detector is under normal operation. When the red LED flashes very frequently and an audible alarm sounds simultaneously, it indicates that the detector senses smoke. NOTE: The red LED behaves according to one of the following set modes: Mode 1: The red LED indicator will not reset automatically at the end of an alarm event. This means that after the smoke chamber is cleared, the audible alarm will stop automati
Electronics Line EL-4703, Wireless Supervisor Photoelectric Smoke Detector 10 TAKING CARE OF YOUR SMOKE DETECTOR To keep your detector in good working condition, you must test the detector weekly, according to the “Testing Your Smoke Detector” section. CLEANING THE SMOKE DETECTOR Clean the housing with a dry or damp cloth to remove dust and dirt. If necessary, open the smoke chamber and clean the interior of the detector. 1. Remove the detector from the detector base. 2. Remove the batteries. 3. Using a flat screwdriver release the smoke detector cover. 4. Using a flat screwdriver lift the smoke chamber housing slightly. 5. Use a fine paintbrush to
Electronics Line EL-4703, Wireless Supervisor Photoelectric Smoke Detector 11 EN Specifications In order to continue improving the product, Electronics Line reserves the right to change specifications and/or designs without prior notice. Note: Smoke detectors are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose. RTTE Compliance Statement Hereby, Electronics Line declares that this equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. For the CE Declaration of Conformity please refer to our website
Wireless Supervisor Photoelectric Smoke Detector 12 Electronics Line Limited Warranty EL and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect the product and because the prod
BRK electronic Smoke and Carbon Monoxide Alarm SC01N Smoke Alarm Operation & user’s manual
Smoke and Carbon Monoxide Alarm SC01N |
Honeywell R7824 Smoke Alarm Product data
R7824 |
White Rodgers 50A62-820 Smoke Alarm Operation & user’s manual
50A62-820 |
LST ECO1003 Smoke Alarm Specification sheet
ECO1003 |
Honeywell GasAlert Extreme Smoke Alarm Operation & user’s manual
GasAlert Extreme |
Firex AD Smoke Alarm Instructions manual
AD |
First Alert SCO5 Smoke Alarm Operation & user’s manual
SCO5 |
Notifier AFP-400 Smoke Alarm Installation manual
AFP-400 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Sharp | AQUOS LC-40LX530H | Operation manual | sharp/aquos-lc-40lx530h-5C7.pdf | 11 Aug 2023 | 81 | |
2 | GeoVision | GV-BX110D | Quick start manual | geovision/gv-bx110d-OA3.pdf | 31 Jan 2024 | 130 | |
3 | Kodak | Pixpro 4KVR360 | Operation & user’s manual | kodak/pixpro-4kvr360-SXZ.pdf | 17 Aug 2023 | 56 | |
4 | Sven | AC-116 | Operation & user’s manual | sven/ac-116-D51.pdf | 16 Dec 2023 | 4 | |
5 | iHome | ibt88 | Operation & user’s manual | ihome/ibt88-P2P.pdf | 06 Jun 2023 | 5 | |
6 | RocketFish | RF-P2USB3 | Quick setup manual | rocketfish/rf-p2usb3-V1X.pdf | 07 Aug 2022 | 2 | 0.16 Mb |
Perenio
PECSS01 Smoke Sensor Quick Start Guide EN……………………………………………………………… 1 LT………………………………………………………………11 RU……………………………………………………………… 2 LV…………………………………………� …
PECSS01(24 pages) |
Notifier
Page 1 of 2 — 990-077990-077, Issue 1 June 2002This document is not intended to be used for installation purposes. Every care has been taken in thepreparation of this document but no liability can be accepted for the use of the information therein.Design features may be changed or amended without prior notice. For more information, contact NOTIFIER.Charl …
SD-851E(2 pages) |
Zooper
ZT 37 -250 PREMIER AL Local Panel Repeater Application, Installation and Commissioning Manual For the PREMIER AL Contents 1.0 Introduction ........................................................................................................... 2 2.0 Cabinet Specifications................................................................................... …
ZT37 -250 REP-AL/P(15 pages) |
Vivanco
Page /SeiteD Bedienungsanleitung 2 –6GB Operating instructions 7 – 11F Mode d’emploi 12 – 16E Manual de Instrucciones 17 – 21I Istruzioni per l’uso 22 – 26NL Gebruiksaanwijzing 27 – 31PL Instrukcja obsługi 32–36P Manual de instruções 37 – 41DK Betjeningsvejledning 42 – 46SD 5YPage /SeiteN Bruksanvisning 47 – 51S Bruksanvisning 52 � …
SD 5Y(96 pages) |
Notifier
DETECTOR TEST LOGDetector Identification InformationManufacturer and Serial DateDetector Model: __________________ Number: ___________________ Installed: ________________Description of Detector Location:_____________________________________________________________________________________________________________________________________________________________ …
DHX-502(6 pages) |
IEH
Für eine umfassende Abdeckung von Haushalten sollten Rauchmelder in allenRäumen, Korridoren, Lagerbereichen, Keller- und Speicherräumen installiertwerden. Eine minimale Absicherung wird erreicht durch je einen Rauchmelderim Flur und im Treppenbereich auf jeder Etage und einer in jedemSchlafbereich. In Häusern mit mehreren Wohneinheiten sollte jede Famili …
22 Series(32 pages) |
Solaire Medical Indoor Furnishing Inner Space EvolveInner Space Evolve (Indoor Furnishing ePDF User Guide, #GBI466) Inner Space Evolve, 6 |
Thermomix Mixer TM5User Guide: Thermomix TM5 (6VT55G, Upd.03.09.2023) TM5, 34 |
American DJ DJ Equipment Sonic Beam IISonic Beam II User instructions - 78676E Sonic Beam II, 8 |
D+H Indoor Furnishing STRATUS BEDD+H Indoor Furnishing Assembly instructions (File: dh-stratus-bed-assembly-instructions-3, 12.11.2023) STRATUS BED, 3 |
MELAG Packaging equipment MELAseal 100+Operating manual for MELAG MELAseal 100+ Packaging equipment MELAseal 100+, 26 |
B-52 Amplifier AT-100Amplifier PDF Instruction manual AT-100, 8 |
Delta Kitchen & Bath Fixtures 21996LFDelta Kitchen & Bath Fixtures 21996LF Manual 21996LF, 6 |
Insignia Battery Pack NS-MB5000-CBattery Pack Quick setup manual (Insignia NS-MB5000-C) NS-MB5000-C, 2 |
Echo Pole Saw PPF-210Pole Saw Operator's manual (Echo PPF-210) PPF-210, 28 |
Dell Laptop Adamo 13Dell Laptop Adamo 13 Service manual Adamo 13, 22 |
Conceptronic Webcam CLLCHATCAM v3.0Conceptronic Product User Manual: CLLCHATCAM v3.0 PDF Quick installation manual - 1934FH CLLCHATCAM v3.0, 71 |
Mettler Toledo Scales Cub-IIScales PDF Service manual Cub-II, 25 |