Manualios.com

Akai AUS-12H53R150P9 Instruction Manual

Akai AUS-12H53R150P9 Manual Online:

3.85, 602 votes
Akai AUS-12H53R150P9 User Manual
Akai AUS-12H53R150P9 User Guide
Akai AUS-12H53R150P9 Online Manual

Text of Akai AUS-12H53R150P9 User Guide:

  • Akai AUS-12H53R150P9, N13275 3.50kW INVERTER Reverse Cycle Split System Air Conditioner AUS-12H53R150P9(De3) Instruction Manual AFTER SALES SUPPORT NZ: 0800 836 761 AU: 1300 886 649 PROTECT YOUR WARRANTY This unit must be installed by a registered, licensed installer as required by Government regulations. FOR THE INSTALLER

  • Akai AUS-12H53R150P9, Contents 1 Safety rules and recommendations for the Installer 2 Safety rules and recommendations for the User 4 Safety rules and prohibitions 5 Selecting the installation place - Installation diagrams 7 - Location of the Indoor unit - Location of the Outdoor unit 7 Installation of the Indoor unit - Securing the mounting plate on the wall 8 - Drilling the wall 9 - Wiring 10 - Attaching the indoor unit to the mounting plate 11 - Pipe connection - Arrangement of the drain hose 12 - Wall sealing and Pipe fastening 13 Installation of the Outdoor Unit - Wiring 15 - Connection diagram 16 - Installation of the drain joint 17 - Join the connecting pipe - Air exhausting 18

  • Akai AUS-12H53R150P9, 1 Safety rules and recommendations for the Installer Please keep this instruction manual in a safe place, along with the warranty card, purchase receipt and carton for future reference. • Read this guide before installing and using the appliance. • During the installation of the indoor and outdoor units, access to the working area should be forbidden to children. Unforeseeable accidents could happen. Make sure that the base of the outdoor unit is rmly xed. • Check that air cannot enter the refrigerant system and check for refrigerant leaks when moving the air conditioner. • Carry

  • Akai AUS-12H53R150P9, 2 • The appliance must be installed 2.5m above the oor Safety rules and recommendations for the User Please keep this instruction manual in a safe place, along with the warranty card, purchase receipt and carton for future reference. • Do not try to install the conditioner alone; always contact specialised technical personnel. • Cleaning and maintenance must be carried out by specialised technical personnel. In any case disconnect the appliance from the mains electricity supply before carrying out any cleaning or maintenance. • Ensure that the mains voltage corresponds to that stamped on the rating plate. Keep the switch or

  • Akai AUS-12H53R150P9, 3 legislation and insert a thermomagnetic circuit breaker. • Unhook the automatic switch if you foresee not to use the device for a long time. The airow direction must be properly adjusted. • The aps must be directed downwards in the heating mode and upwards in the cooling mode. • Only use the air conditioner as instructed in this booklet. These instructions are not intended to cover every possible condition and situation. As with any electrical household appliance, common sense and caution are therefore always recommended for installation, operation and maintenance. • Ensure that the a

  • Akai AUS-12H53R150P9, 4 Safety rules and prohibitions • Do not bend, tug or compress the power cord as this could damage it. Electrical shocks or re are usually due to a damaged power cord. Only specialised technical personnel must replace a damaged power cord. • Do not use extensions or gang modules. • Do not touch the appliance when barefoot or parts of the body are wet or damp. • Do not obstruct the air inlet or outlet of the indoor or the outdoor unit. The obstruction of these openings causes a reduction

  • Akai AUS-12H53R150P9, 5 Selecting the installation place Installation diagrams IMPORTANT: Only persons and/or companies qualied and experienced in the installation, service and repair of refrigerant products should be permitted to do so. The purchaser must ensure that the person and/or company who is to install, service or repair this air conditioner has qualications and experience in refrigerant products. NOTE: Installation location notes are found on pg. 7. NOTE: The gures of the air conditioner and its working parts (above and right) are only intended to be a simple diagram of the appliance and may not correspond

  • 6 While installing the pipeline on the thin armor plate or on the wall of metal mesh, you should use a wooden board to clamp between the wall and the pipeline or wrap the pipeline with 7–8 layers of insulating plastic tape. IMPORTANT: The allowable length of the connecting pipe is 10m. The allowable distance between the indoor unit and outdoor unit is 5m. Cover

  • Akai AUS-12H53R150P9, 7 1. Location of the Indoor unit • Keep the air inlet and outlet at a far distance from the blockage. • Keep the height distance between the indoor and outdoor unit at most 5m. • Mount securely on a wall solid enough to bear the weight of the unit. Ensure that the wall chosen is not subject to vibration or shaking. • Avoid direct sunshine. • Condensate drain must sit comfortably and be easy for connecting with the outdoor unit. • Keep a far distance away from uorescent light; it may inuence the operation of remote controller. • Keep at least 1m away from the TV or radio and other home appliances. 2. Locati

  • Akai AUS-12H53R150P9, 8 2. Drilling the wall • The holes at solid arrow position must be secured to avoid the mounting plate shaking or moving. • When the expansion bolts are used, two holes (11x20 or 11x26) should have the distance of 450mm between them adopted. • Mark the wall to conrm the position of holes and drill holes on the wall. Center of hole( ) 65mm Center of hole( ) 65mm Pipe hole

  • Akai AUS-12H53R150P9, 9 3. Wiring 1. Open the front grille. 2. Remove the screw from electrical box cover, pull the electrical box cover away from the unit and set aside. 3. Remove the screw from fastener, pull the fastener away from the unit and set aside. 4. Connect the cable. 5. Replace the fastener and electrical box cover. NOTE: • The appliance shall be installed in accordance with national wiring regulations. • The appliance must not be installed in the laundry. • The appliance must be installed 2.5m above the oor

  • Akai AUS-12H53R150P9, 10 Route of pipe • If pipe comes out of the right side of the indoor unit, cut part “1” of the unit; • If pipe comes out of the lower-right side of the indoor unit, cut part “2” of the unit; • If pipe comes out of the left side of the indoor unit, cut part” 3” of the unit. Ret of drain hose • If pipe comes out of the left side of the indoor unit, the drain hose must be retted, otherwise water leakage may occur. • Readjustment methods: Interchange the position of drain hose and drain rubber plug. •

  • Akai AUS-12H53R150P9, 11 6. Pipe connection • The number of bent position of the pipe in the indoor unit should not exceed 10. • The number of bent position of the pipe in the indoor unit and the outdoor unit should not exceed 15. • The radius of bent position should be more than 10cm. • Please break the evaporator craft tube with pincers before connecting. After exhausting the inside air, use the wrench to twist down the nut of the connecting tube of the evaporator. (Fig. 1) Put some seal oil to cover the joint and the are. • Align the centre of joint in line with that of are and tighten the nut of connecting pipe with wrench. (Fig. 2) IMPORTANT: • Do not exhaust the i

  • Akai AUS-12H53R150P9, 13 Installation of the Outdoor unit 1. Wiring Wiring For Above 6000W Model (above 21000BTU/h model) 1. Remove the self-tapping screws (2 pcs) on the maintenance board and take out the maintenance board. 2. Loosen the self-tapping screws (2 pcs) on the xing clip to loosen the xing clip. 3. Loosen the xing screw of the wire terminal board, pass the power wire and signal wire through the xing clip. Then rmly x the power wire and signal wire on the terminal board with the xing screw. (Earth wire must be connected rmly.) Single Spli

  • 14 The cable wire can be led from the back hole of the piping hole or ejecting hole. Please utilize outdoor pipe support when the cable wire is led from the backside. 4. Tighten the self-tapping screw on the xing clip. 5. Install the maintenance board. After the pipes and cable wire are installed, please seal the sponge block as per drawing indication.

  • 15 Connection diagram NOTE: • If not include the connect diagram you need, please see the wiring diagram. • If you nd that the color of connecting cable does not comply with the top diagram, please take the actual purchased products as your major reference. However, the terminal of the same sign must be joint with the connecting cable of the same color. • The plug h

  • Akai AUS-12H53R150P9, 16 • Special cable must be used to connect indoor unit and outdoor unit. It should be ensured that the terminals are not inuenced by external force. Poor connection may cause re. • The electric box cover must be mounted and secured in position, otherwise re or electrical shock may occur because of dust or moisture. • The temperature of refrigerant circuit will be high. Please keep the interconnection cable away from the connecting tube. • All the models shall be connected with the mains which have system impedance limitations. While installing the unit, please see the following table for impedance information or cons

  • Akai AUS-12H53R150P9, 17 3. Join the connecting pipe • Put some seal oil to cover the joint and the are. • Align the centre of joint in line with that of the are and tighten the nut of the connecting pipe with a wrench. (Adjust the torque by the same method of connecting pipe for the indoor unit.) 4. Air exhausting • Screw down the cap of both gas shut-o valve and liquid shut-o valve as well as the nut of service port. • Use an Allen key to turn the valve cork of the liquid side

  • Akai AUS-12H53R150P9, 18 5. Process of ared tube • Use the pipe cutter to cut o the broken part of are. • Remove burrs at the cut of the are. • Insert a nut into the connecting pipe and do aring with specied aring tools, reamers for example. • Check the quality of the aring technique

  • 19 6. Adding refrigerant • If the connecting pipe is longer than 7m, add refrigerant as needed. Add amount A= (Lm-7m) x 50g/m. (A = amount of added refrigerant; L = the length of connecting pipe) • Exhaust the air as the above- mentioned method. • Screw the gas shut-o valve to close, connect charging hose(low pressure) to the service valve and then open gas

  • Akai AUS-12H53R150P9, 20 Operation test Before test operation, wiring safety inspection must be carried out carefully again. • Emergency switch operation: Every press of emergency switch, the air conditioner runs as in the following order: Heat pump type: Cool --> Heat --> Shut o • Remote controller operation: If the indoor unit sounds like “Di, di” when pressing I/O button, that indicates the air conditioner is under the operation of remote controller. After that, press every button to test their functions. • Ch

  • Akai AUS-12H53R150P9, Warranty We pride ourselves on producing a range of quality home appliances that are both packed with features and completely reliable. We are so condent in our products, we back them up with a full 2 year replacement warranty. Now you too can relax knowing that you are covered. Customer Helpline NZ: 0800 836 761 AU: 1300 886 649 This Product is covered by 2 year replacement warranty when accompanied by proof of purchase.

More Instructions:

DOWNLOAD

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Samsung E810 Service manual samsung/e810-1ID.pdf 18 Dec 2023 28
2 Sony DVP-NC600 (DVP-NC600 CD/DVD Player) Operating instructions manual sony/dvp-nc600-dvp-nc600-cd-dvd-player-1OA.pdf 13 Sep 2022 84 1.19 Mb
3 Quer Micropower 400 Operation & user’s manual quer/micropower-400-B34.pdf 11 Sep 2023 28
4 Printek 850 Series Operator's manual printek/850-series-AYP.pdf 27 Feb 2024 108
5 Leading Edge HX8410 Operation & user’s manual leading-edge/hx8410-1ID.pdf 30 Mar 2023 25
6 Monoprice VGA Operation & user’s manual monoprice/vga-28C.pdf 29 Nov 2023 2

Similar Resources:

  • Mitsubishi Electric

    MXZ-2B20NA

    (25 pages)
    MITSUBISHIELECTRICSplit-type Air-ConditionerIViXZ-2B20NAiNSTALLATiON MANUAL]• Refer to the installation manual of each indoor unit for indoor unit in- |/stallation.This manual mentions how to install only the outdoor unit MXZ-2B20NA.As for the way of installation for indoor unit, please refer to the installation manualbeing attached each indoor unit.The in …
  • Samsung

    SPF-83V

    (13 pages)
    | Installation| Installing USB driver| Installation 1. Click the Frame Manager icon to run the setup file. 2. Click Next. 3. Select I agree to the terms of this license agreement and click Next. 4. Click Next. Install the Application first before connecting the Digital Photo Frame to a PC. To Install the Frame Manager Software and USB Secondary Di …
  • Mitsubishi Electric

    Y Series

    (16 pages)
    CONTENTS1. Specifications2. Capacity Tables2-1 Correction by temperature2-2 Correction by total indoor2-3 Correction by refrigerant piping length2-4 Correction at frosting and defrosting2-5 Operation limit3. Sound Levels4. External Dimensions5. Electrical Wiring Diagram6. Refrigerant Circuit Diagram And Thermal SensorPUMY-71VM, PUMY-125VM·········� …
  • Stirling

    A013A-14CB

    (24 pages)
    Portable Air ConditionerINSTRUCTION MANUALAFTER SALES SUPPORT1300 886 [email protected]: A013A-14CB PRODUCT CODE: 12221 10/2019Model Number A013A-14CB …
  • TCL

    TAC-12CPA

    (27 pages)
    TCL Air Conditioner Service Manual1TCLPORTABLE AIR CONDITIONERSSERVICE MANUAL No.________ModelsTAC-12CPA/KATAC-12CHPA/KATAC-14CPA/KATAC-14CHPA/KACONTENTS1. IMPORTANT NOTICE2. TECHNICAL SPECIFICATION3. REFRIGERATION CYCLE DIAGRAM4. OPERATION DETAILS5. WIRING DIAGRAM6. EXPLOSION VIEW AND PART LISTS7. PRECAUTION8. NAMES OF PARTS9. INSTALLATION MANUAL10. CARE AN …
  • Premier

    CR-4758R

    (18 pages)
    MANUAL DE INSTRUCCIONES ENFRIADOR DE AIRE PORTÁTIL CR-4758R ESTIMADO CLIENTE Con el fin de que obtenga el mayor desempeño de su producto, por favor lea este manual de instrucciones cuidadosamente antes de comenzar a utilizarlo, y guárdelo para su futura referencia. Si necesita soporte adicional, no dude en escribir a: info@ …

Comments, Questions and Opinions: