Manualios.com

Akai MWF-18CRN1-QC1G Instruction Manual

Akai MWF-18CRN1-QC1G Manual Online:

3.6, 2791 votes
Akai MWF-18CRN1-QC1G User Manual
Akai MWF-18CRN1-QC1G User Guide
Akai MWF-18CRN1-QC1G Online Manual

Text of Akai MWF-18CRN1-QC1G User Guide:

  • Akai MWF-18CRN1-QC1G, 18 After Sales Support 1300 886 649 5.4.2 Installation of the unit into the housing • Slide the unit into the housing until it is rmly against the rear of the housing. Care is required to ensure the foam sealing strips on the housing remain in position. • Connect the air conditioner to the power and position excess cord length beneath the air conditioner base. • Engage the chassis xing brackets into the bottom housing rail and secure to the base with the screw provided. • Remove the front panel from it's carton and plastic bag and t as per the installation instruction. • Switch unit on. Check for op

  • Akai MWF-18CRN1-QC1G, 31 After Sales Support 1300 886 649 Compressor doesn’t work. Check whether the indoor temperature is lower than 15°C or larger than. Check whether the voltage is too high or too low. Check whether the compressor is under overload protection. Check the power supply. Check the wiring. Check whether the relay of compressor in PCB works normally (Start the unit, after 3mins, and set the unit with cool mode and 17°C (62°F). Then check the output of relay and replace the PCB if failed. Check whether the externa

  • Akai MWF-18CRN1-QC1G, 22 After Sales Support 1300 886 649 7.1 Cooling operation Outdoor air temp. °C DB Indoor air temp. °C DB Note: The chart is the result from the continuous operation under constant air temperature conditions. However, excludes the initial pull-down stage. 7. Operation limits

  • Akai MWF-18CRN1-QC1G, 7 After Sales Support 1300 886 649 4.1 Unplug the power cord and move the unit to open place. 4.2 How to disassemble front panel. You should unplug the power cord (see 1 step). First, pull the front panel from bottom side. Second, open left and right side slots, lift the front panel up at the same time. 4. Disassembly instructions slot

  • Akai MWF-18CRN1-QC1G, 2 After Sales Support 1300 886 649 1.1 Safety precaution • To prevent injury to the user or other people and property damage, the following instructions must be followed. • Incorrect operation due to ignoring instruction will cause harm or damage. • Before service unit, be sure to read this service manual at rst. 1.2 Warning • Do not use damaged power cords, plugs, or a loose socket. • Always use the power plug and socket with the ground terminal. • Do not modify or extend the power cord. • Do not turn the air-

  • 16 After Sales Support 1300 886 649 5.2 Check o installation • The setting conditions must be checked prior to initial starting. The under mentioned items are especially important checking points when the installation is nished. • Grounding wire (yellow/Green) is provided in the power cord. The wire must be grounded. • Ensure that the unit is

  • Akai MWF-18CRN1-QC1G, 30 After Sales Support 1300 886 649 Display keeps showing "Ed". Check whether the evaporator frosts. Check whether the indoor ambient temperature is too low. Check whether there is too much water on the chassis. Check whether the indoor air inlet is blocked. Check whether the indoor dust lter is too dirty. Check the wiring of pipe temperature sensor. Check the pipe temperature sensor. Replace the pipe temperature sensor. Replace the main control board. No No No No No No No Yes

  • Akai MWF-18CRN1-QC1G, 20 After Sales Support 1300 886 649 Step 4. Install the frame. Install the frame making sure not to interfere with the temperature sensor cable (See Fig.9). Fix the screws on the frame (See Fig.3). Step 5. Install the air lter and front panel. Install the air lter into the frame's slot from upside to underside (See Fig.2). Hang the front panel on the frame's buckle, then press the front panel into the frame's slot until you hear a click (See Fig10).

  • Akai MWF-18CRN1-QC1G, 17 After Sales Support 1300 886 649 5.4 How to install 5.4.1 Installation of the housing Step1 Remove the air conditioner from it's packaging, remove xing screws and slide the air conditioner out of it's housing (Refer to Installation Steps) Step2 Prepare the hole in the wall so that the bottom of the housing is well supported, the top has minimum clearance and the air inlet louvers have clearance as shown below in options A and B. Holes from the outside through to the cavity should be sealed. The housing should slope down towards the rear b

  • Akai MWF-18CRN1-QC1G, 6 After Sales Support 1300 886 649 3. Unit dimension Model A (mm) B (mm) C (mm) MWF-05CRN1-QC1G 346 450 535 MWF-07CRN1-QC1G MWF-07HRN1-QC1G MWF-09CRN1-QC1G 380 600 560 MWF-09HRN1-QC1G MWF1-12CRN1-QC1G MWF-12HRN1-QC1G 430 660 687 MWF-16CRN1-QC1G MWF-16HRN1-QC1G MWF-18CRN1-QC1G MWF-18HRN1-QC1G 430 660 770 MWF-21CRN1-QC1G MWF-21HRN1-QC1G

  • Akai MWF-18CRN1-QC1G, 33 After Sales Support 1300 886 649 The compressor operates run-stop frequently. Check whether the airow passage is blocked. Check whether capacitor of compressor work normally. Replace the PCB. Check whether the fan motor doesn’t work. Check whether the capillary is blocked. Replace the capillary. Replace the compressor. Check whether the relay of compressor on PCB works normally. No

  • Akai MWF-18CRN1-QC1G, 11 After Sales Support 1300 886 649 Third, snip the tighten strip as following and pull the Electrical Box. Fourth, remove the Electrical Box’s front plastic cover. Fifth, remove the screws and open the Electrical Box. Tighten strip

  • Akai MWF-18CRN1-QC1G, 1 After Sales Support 1300 886 649 Contents 2 1. Precaution 3 2. Features and panel 6 3. Unit dimension 7 4. Disassembly instructions 15 5. Installation 21 6. Refrigerant cycle diagram 22 7. Operation limits 23 8. Wiring diagram 27 9. Protection function 29 10. Troubleshooting 38 11. Characteristic of temperature sensor

  • Akai MWF-18CRN1-QC1G, 27 After Sales Support 1300 886 649 9.1 Proper symbols and their meaning • T1: Indoor ambient temperature • T2: Indoor evaporator temperature • T3: Outdoor condenser temperature • Ts: Setting temperature through the remote controller 9.2 Protection Function 9.2.1 Three minutes delay at restart for compressor. 9.2.2 Anti-freezing protection at cooling or dry mode. • Anti-freezing control according to T2 (Indoor evaporator temperature). If the evaporator pipe temperature had been lower than 1°C for 14 minutes, the evaporator anti-freezing protection will be activated. The compressor will keep o in the following

  • Akai MWF-18CRN1-QC1G, 21 After Sales Support 1300 886 649 The gure below is a brief description of the important components and their function in what is called the refrigeration system. This will help to understand the refrigeration cycle and the ow of the refrigerant in the cooling cycle. 6. Refrigerant cycle diagram

  • Akai MWF-18CRN1-QC1G, 3 After Sales Support 1300 886 649 2.1 Features • Powerful cooling. • Slide-in and slide-out chassis for the simple installation and service. • Side air-intake, side cooled-air discharge. • Washable one-touch lter and easy removed panel. • Super compact design. • Reliable and ecient rotary compressor is equipped. • Unique Quiet Design. • Fresh air switch. • Anti-freezing control in cooling mode. Prevent the water being freezed on evaporator by sensing the evaporator pipe temperature in cooling mode. • Time Delay Safety. Restarting is for approx. 3

  • Akai MWF-18CRN1-QC1G, 9 After Sales Support 1300 886 649 4.5 How to pull the refrigerant system from unit cabinet. 4.5.1 You should unplug the power cord (see 1 step). 4.5.2 You should disassemble the front panel (see 2 step). 4.5.3 You should remove the lter (see 3 step). 4.5.4 You should disassemble the front frame (see 4 step). First, remove left and right screws (2) and back screws (2) as following pictures. Second, pull the refrigerant system with grip as following. g ri p

  • Akai MWF-18CRN1-QC1G, 12 After Sales Support 1300 886 649 4.7 How to disassemble the centrifugal fan (indoor). 4.7.1 You should unplug the power cord (see 1 step). 4.7.2 You should disassemble the front panel (see 2 step). 4.7.3 You should remove the lter (see 3 step). 4.7.4 You should disassemble the front frame (see 4 step). 4.7.5 You should pull the refrigerant system from unit cabinet (see 5 step). First, remove the four screws and evaporator, disassemble the screw of centrifugal fan. Second, remove the 2 screws as following, disassemble the air inlet cover and take o centrif

  • Akai MWF-18CRN1-QC1G, 34 After Sales Support 1300 886 649 Water drips from the unit. Check whether the ambient humidity is too high. Check whether the unit is correctly installed. Check whether the foam of evaporator base is damaged. Check whether the indoor outlet airow foam is too wet, and louver drip. Check whether the drain passage of evaporator is blocked. Replace if failed. Check whether the air outlet foam install normally. Fan motor speed can’t change. Check the wiring. Replace the PCB. Check the capacitor of fan motor. Replace if fa

  • Akai MWF-18CRN1-QC1G, 32 After Sales Support 1300 886 649 Cooling mode doesn't work or cooling not enough. The air-con doesn’t work. Check the operation mode. Check the power supply. Check whether dust lter is too dirty. Replace the PCB. Replace the capillary. Check the setting temperature. Check the wiring. Start the unit with cool mode and check whether the temperature of compressor’s discharge pipe is smaller than 90°C. If no, recharge refrigerant. Check whether the transformer is failed. Measure the output voltage of transformer and check whether it is the range from +5V to 12V. If not, replace the transformer. No No No No No No No

More Instructions:

DOWNLOAD

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Dodge RAM 2500 hEAvy Duty 08 Buyer's manual dodge/ram-2500-heavy-duty-08-E85.pdf 29 Dec 2022 15 1.63 Mb
2 MSI MS-7199 Operation & user’s manual msi/ms-7199-18M.pdf 24 Jul 2023 27
3 Sony NAS-Z200IR Operating instructions manual sony/nas-z200ir-HUY.pdf 24 Feb 2024 84
4 Nilfisk-Advance SW4000 Service manual nilfisk-advance/sw4000-972.pdf 22 Jan 2023 232
5 Directed Electronics VA200 Installation manual directed-electronics/va200-3A7.pdf 26 May 2023 1 0.02 Mb
6 Barco iD H250 Specifications barco/id-h250-M94.pdf 15 Jun 2023 2 0.36 Mb

Similar Resources:

  • Impecca

    IPAC16-BRB

    (80 pages)
    Portable Air Conditioner—User Manual Aire Acondicionado Portátil – Manual de UsuarioClimatiseur Portatif – Manuel De L'utilisateurModel: IPAC16-BRBwww.impecca.comV 1.97 …
  • Seifert

    Progressive Series

    (22 pages)
    Version Nr. 1-6 - 25.07.2022 Doc. No. 9987030082USL 1 / 22Table of Content 87030082USL1. User manual 2 .................................................................................................................................. 2. Legal regulations 2 ..................................................................................................... …
  • Samsung

    LN40A630M1F

    (107 pages)
    Contact SAMSUNG WORLDWIDEIf you have any questions or comments relating to Samsung products, please contact the SAMSUNG customer care center.Contacte con SAMSUNG WORLDWIDESi tiene alguna pregunta o comentario referente a nuestros productos, por favor contacte con nuestro Servicio de Atención al Cliente.CountryCustomer Care CenterWeb Site AddressCANADA 1-80 …
  • dirna Bergstrom

    Bycool Green Series

    (62 pages)
    220AA35381Air conditioning for vehiclesF-4218 rev.01SLIM FITInstrucciones de MontajeESSpanishMounting InstructionsENEnglishInstructions de MontageFRFrenchMontageanweisungenGEGermanIstruzioni di MontaggioITItalian …
  • Frigidaire

    FAC086L7A2

    (12 pages)
    ROOM AIR CONDITIONERModel No.FAC086L7A©2002 Electrolux Home Products, Inc.All rights reservedFACTORY PARTS CATALOGROOM AIR CONDITIONERWIRING DIAGRAM - # 309341601OWNER’S GUIDE - # 309000825ENERGY GUIDE - # 309369904ELECTROLUX HOME PRODUCTS, INCP.O.BOX 212378, AUGUSTA, GA 30917PRODUCT NO. BASE MODEL NO. SERIES VOLTS BTU-COOLINGFAC086L7A2 FAC086L7A Gallery …
  • Fujitsu

    9319357041

    (14 pages)
    EnglishFrançaisEspañolINSTALLATION MANUALMANUEL D’INSTALLATIONMANUAL DE INSTALACIÓNFor authorized service personnel only.Pour le personnel agréé uniquement.Solo para personal autorizado.PART NO. 9319357041AIR CONDITIONER9319357041_IM.indb 19319357041_IM.indb 1 11/30/2011 1:31:47 PM11/30/2011 1:31:47 PM …

Comments, Questions and Opinions: