  • 1 Dual-network Wired&wireless LCD Alarm System User Manual Table of Contents 1 Features and Technical Parameter……………………………………………………………………Page 2 2 Zone Types and Definitions…………………………………..……………………………………… .Page 2 3 Modes of arming……………………

  • Alarma 5200, 2 Ⅰ、Features 1. Touch keypad; Big LCD displays(Capacitive touch screen times,New experience) 2. GSM+PSTN dual network. If PSTN is disable, it will switch to GSM automatically 3. Calendar+5 alarm call(SMS) No.+1 alarm center call No.+1 alarm SMS No.+ 10S record+ Arm Delay + Alarm Delay + Alarm Beep Setting+ Call-in time setting+ Wireless Program+ Zone Attribute Setting+ User password + Program Password + Reset +100 Alarm History and Status History 4. 30 wireless zones + 8 wired zones, every zone attribute, name, bypass, alarm delay, intelligent door sensor function, beep indication could do free setting. 5. Alarm Inform Mode: P

  • 3 Alarm Host Fron Alarm Host Backside Ⅵ、LED Indicators Left Blue LED:GSM Signal indicator Quick flash: No signal or the SIM Card don’t fix properly Slow flash : get signal, under workin

  • Alarma 5200, 4 Ⅶ、Shortcut Keys ●Under standby, press “ ”, away arm activate ●Under standby, press “ ”, home arm activate ●Under standby, press “ ”+Password+” ”, disarm activate(User Password Default:1111) ●Under standby, press “ ” to check alarm or status history. Press “ ” to change pages ●Under standby, press “SOS” for 2 second, emergency alarm activate Ⅷ、Prompt tone ●Press any buttons--- one short tone ●Arm--- one short tone ●Away arm delay--- one short tone every second ●Alarm delay--- one short tone ev

  • Alarma 5200, 5 9.3【SMS Setting】: a. “ ” delete the original phone number, enter your new phone No. to save(only for SMS, no call) b. to select “AC Power off or recover inform”, and choose “Yes” or “No”. to save c. to select “Arm or Disarm inform”, and choose “Yes” or “No”. to save d. to select “PSTN off inform”, and choose “Yes” or “No”. to save e. to select “Alarm Host Back-up Battery Low Level Inform”, and choose “Yes” or “No”. to save Total is 1 group alarm phone number, max. 15 bytes. All default settings is No 9.4【Record】:

  • Alarma 5200, 6 b. Arm or disarm internal siren: to choose “Yes” or “No”. to save. Default is “No” c. Arm or disarm wireless siren : to choose “Yes” or “No”. to save. Default is “No” Note that the wireless siren max. sound time is 59 minute 9.9【Call In Setting】: a. PSTN Phone No: “ Delete” the original setting, and enter ring (1 to 9), to save. Default is 6 ring b. GSM Phone No: “ Delete” the original setting, and enter right (1 to 9), to save. Default is 3 ring 9.10【 Program & delete 】: a. Program:” Delete” the zone No, enter new zone No.”▼”

  • Alarma 5200, 7 Zone Number 00 12 21 01 02 Sensor Code Menu Name CID Code CID Name 00 Medical Alarm E100 Medical Alarm 01 Emergency E121 emergency alarm 02 Emergency( E120 emergency alarm 03 Fire Alarm E110 fire alarm 04 Smoke Alarm( E111 smoke alarm 05 Kitchen E130 burglar alarm 06 Gas Leak Alarm E112 gas alarm 07 Tamper Alarm E137 tamper alarm 08 Heat Alarm E158 heat alarm 05 1 st group zone E131 1 st group zone 06 Door E134 2 nd group zone 07 Front Door E134 2 n

  • Alarma 5200, 8 Sensor Door Wire less zone 21 22 23 24 25 26 27 28 29 30 Type Defa ult Alar m Delay Cod e 13 PIR 13 PIR 12 PIR 14 Drawing Room 14 Drawing Room 15 Bedroom 15 Bedroom 15 Bedro om 12 Car House 17 Doorb ell 2 nd group zone on 0ff Wire zone 31 32 33 34 35 36 37 38 Type Defa ult Alarm Delay Cod e 06 Door Sensor 051 st group zone 051 st group zone 13 PIR 13 PIR 00 Emergen cy 03 Fire 04 Kitche n 31/32/33

  • Alarma 5200, 9 9.14【Pin setting】: Delete the original password, and enter new password(4 digits),delete and enter again to confirm the new password. to save. Default is 1234 9.15【Reset】: Reset: “ ”--- “Yes” or “No”, to save. After reset all information will recover to default setting, include alarm phone No., SMS information setting, arm delay setting, zone attribute, delete all sensors, Central Monitoring Center Upload. User Password:1111 and program password:1234 Note that if finish the setting, press ”ESC” to exit. If don’t operate within 30S,it will exit automatically. Program Password Reset: Press key button on b

  • 10 If start alarm: a. The alarm host will dial CID CMS to upload alarm information firstly via PSTN b. And then dial and send SMS to personal phone No’s in queue. If the PSTN and GSM are available, PSTN own priority. This mean will call via PSTN and send SMS via GSM. The SMS content is “XX zone YYYY is alarming”. XX mean zone No. YYYY mean sensors name, for details please check tabl

  • Alarma 5200, 11 Activate Sensors Alarm Host Passive Sensors Alarm Host Note:V1 mean +12V power source, A1 mean 31 to 38 zone. . Understanding of Basic Accessories (Wireless) Wireless Remote Features:  To control the alarm host to arm and disarm.  With the emergency key for urgent help. Specifications:  Operating power: 27A 12V alkaline battery  Emitting distance: ≥100m (in open area)  Service life: ≤1 year Program sensor / Delete sensor a. Porgam sensor 1.1、【 SET + Progarmming code + “▲▼”to choose“Program&delete” + ENT + p

  • Alarma 5200, 12 Program sensor / Delete sensor a. Porgam sensor 1.1、【 SET + Progarmming code + “▲▼”to choose“Program&delete” + ENT + press“Delete/Left button + input YY+ “▲▼” to choose Program + ENT】( LCD screen would say“programming”); 1.2、Trigger door sensor 2 times,alarm host panel would say“study successfully”, press“ENT”, and it means succefully in setting。 1.3、“ Y Y”: means zone number with 2 digits, can be from 11~20 b、Delete sensor 1. 1、【 SET + Progarmming code

  • Alarma 5200, 13 ●SIM card not found,GSM not dialing out or no SMS sent ●SIM card unloaded ●SIM requires a password to dial ●GSM signal not good ●SIM card contact points not good ●Voice calling disable ●SMS message disable ●SIM card is a pre-paid type of card and no enough deposit ●Closed the SMS messages function ●Install SIM card ●Cancel the password of SIM ●Change place of alarm panel to test signal ●Change other SIM for trial ●Make sure voice calling an

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Southwestern Bell FM2552 Owner's manual southwestern-bell/fm2552-14J.pdf 03 Dec 2022 16
2 Essex Electronics Encoded Keyless Entry Installation instructions manual essex-electronics/encoded-keyless-entry-676.pdf 30 Jun 2023 40
3 Yamaha DTT3KSP Manual  yamaha/dtt3ksp-5VT.pdf 11 Nov 2023 1 0.24 Mb
4 Sanyo AVM-2751S Owner's manual sanyo/avm-2751s-FU9.pdf 03 Apr 2023 52 3.63 Mb
5 Viking Professional 7 Series Installation manual viking-professional/7-series-UW9.pdf 02 Nov 2023 14
6 Compaq ProLiant 8500 Technology brief compaq/proliant-8500-M91.pdf 03 Feb 2023 23 1.99 Mb

Similar Resources:

  • X10

    VT38A

    (7 pages)
    IIIIINDOORNDOORNDOORNDOORNDOOR/O/O/O/O/OUTDOORUTDOORUTDOORUTDOORUTDOOR C C C C COLOROLOROLOROLOROLORCCCCCAMERAAMERAAMERAAMERAAMERA WITHWITHWITHWITHWITH B B B B BUILUILUILUILUILTTTTT-----INININININ 2.4 2.4 2.4 2.4 2.4GHGHGHGHGHZZZZZ W W W W WIRELESSIRELESSIRELESSIRELESSIRELESS T T T T TRANSMITTERRANSMITTERRANSMITTERRANSMITTERRANSMITTER,,,,,MMMMMOOOOOTIONT …
  • Roule

    RL-0506AB

    (2 pages)
    RL-0506AB MULTI-DIRECTION WIRELESS ALARM SYSTEM Equipments: 1. 3×magnet sensor(enclosed 3 ×LR44 batteries, each sensor with double-side tape.) 2. 1×main unit(enclosed 3×AA batteries) 3. 3×infrared sensor (used 3×AAA batteries, low-power consumption.) 4. 2×remote(enclosed 1×23A battery for each remote.) Usage: • Ideal for house, …
  • ACA

    ALLERTOR 125

    (17 pages)
    - 1 - INSTALLATION OPERATION MAINTENANCE And PARTS MANUAL 4801 W. Woolworth Ave. Milwaukee, WI. 53218 Phone # (414) 358-8000 Fax # (414) 358-8008 ALLERTOR 125 ROTATING DIRECTIONIAL SIREN …
  • Kidde

    123I

    (8 pages)
    1Thank you for purchasing a Kidde Fyrnetics alarm. Please read through our guide in full. It should be retained for future reference.Kidde Fyrnetics recommends for maximum protection that both ionisation andphoto-electric (optical) smoke alarms be installed. Ionisation technology is faster atdetecting fast flaming fires that give off little smoke. Photo-elec …
  • Cisco

    ASA 5512-X

    (12 pages)
    QUICK START GUIDECisco ASA 5500-X SeriesASA 5512-X, ASA 5515-X, ASA 5525-X, ASA 5545-X, and ASA 5555-X1 Powering On the ASA2 Connecting Interface Cables and Verifying Connectivity3 Launching ASDM4 Running the Startup Wizard5 (Optional) Allowing Access to Public Servers Behind the ASA6 (Optional) Running VPN Wizards7 (Optional) Running Other Wizards in ASDM8 …
  • ADEMCO

    TI110B1

    (18 pages)
    1TI110B1 GSM/PSTN Dual Network Burglar Alarm System .OverviewⅠ TI110B1 GSM/PSTN Dual Network Burglar Alarm System is ADEMCO compatibility alarm system, which adopts the advanced security technology, American-originated chipsets and siemens industrial-grade GSM module. And it boasts its dual networks to send alarm information out. When something wrong …

Comments, Questions and Opinions: