Manualios.com

Carrier Access Adit 3500 Quick Start Manual

Carrier Access Adit 3500 Manual Online:

3.35, 1982 votes
Carrier Access Adit 3500 User Manual
Carrier Access Adit 3500 User Guide
Carrier Access Adit 3500 Online Manual

Text of Carrier Access Adit 3500 User Guide:

  • Adit 3500 - Release 1.6 37 Quick Start Guide Basic Configuration 9. Select (click) New Connection to create the ML-PPP connection. 10. Select the Multilink Point-to-Point Protocol over DS0 (Multilink), and select Next.

  • Adit 3500 - Release 1.6 15 Quick Start Guide Installation #2 Adit 3500 and Battery Backup mounted to the wall This method requires a more wall space. Note: This installation will require a minimum of wall space of: 17" (H) x 14" (W) x 2.5" (D). 1. Mount the Battery Backup to the wall with (4) #6 screws, by: z Mark the location of the left-side 2 screws (using

  • Carrier Access Adit 3500, Adit 3500 - Release 1.6 19 Quick Start Guide Interface Connectors DS1/E1 Connection Ports Each DS1/E1 connection port is equipped with a standard RJ-48C (female) on the Adit 3500 unit. Note: E1 will be available in a future release. The pinouts are as follows: DS1/E1 RJ-48C The pinouts are as follows: The LEDs are as follows (left LED only): Pin Name Description 1 Receive Ring Receive from DS1 network 2 Receive Tip Receive from DS1 network 3 N/C Not connected 4 Transmit Ring To DS1 network 5 Transmit Tip To DS1 network 6 -8 N/C Not connected State Description Off Off line Green Normal Red Loss of Signal (LOS) Yellow Bipolar Violation (BPV) Flashing Green Loopback active F

  • 12 Adit 3500 - Release 1.6 Quick Start Guide Installation Battery Backup This is an Optional Feature. The Adit 3500 Battery Backup is designed specifically for the Adit 3500. The battery backup unit is a single 12V sealed lead-acid battery in a metal enclosure designed for wall mounting. Installation There are two possible configurations to wall mount

  • Carrier Access Adit 3500, 42 Adit 3500 - Release 1.6 Quick Start Guide Basic Configuration 4. Select the Enable button, to configure the WAN Ethernet up (or in-service). 5. Select the Settings button. 6. Set Network type to WAN. 7. Set Internet Protocol option (method of IP address assignment). 8. Select OK to apply the new settings and exit this window. 9. Select OK again to return to the Network Connections window.

  • Carrier Access Adit 3500, 36 Adit 3500 - Release 1.6 Quick Start Guide Basic Configuration 4. Set the proper Framing Type and Line Coding. 5. Select OK to apply the new settings and exit this window. 6. Select OK again to return to the Network Connections window. 7. Repeat steps #1-6 for additional T1s required for the ML-PPP 8. Select (click) the delete icon associated with the Serial 1 connection. Select OK to confirm the deletion of this connection.

  • Carrier Access Adit 3500, 24 Adit 3500 - Release 1.6 Quick Start Guide Setting up a CLI Connection Setting up a CLI Connection A CLI connection will require the LAN or WAN IP address of the unit. Note: If the WAN IP address is used, the remote admin WAN access must be enabled with the following command sequence: NOTE: For Adit 3500 CLI commands see the Adit 3000 CLI Reference Manual. This is a separate document and can be found on the CD that is provided with the product, or on the Carrier Access customer website. To connect with CLI, set up the connection: z If connecting via the Ethernet 100Base-TX connection, use a Telnet TCP/IP program to access the CLI. This requires an IP address

  • Carrier Access Adit 3500, Adit 3500 - Release 1.6 29 Quick Start Guide Basic Configuration Modify Default Admin User For security purposes it is recommended that the Administrator User be changed from the default settings. Modify the Administrator User in the web-browser: z Select Advanced from the Navigation bar z Select Users icon z Select Administrator, to open the profile.

  • Carrier Access Adit 3500, Adit 3500 - Release 1.6 39 Quick Start Guide Basic Configuration 15. The new Multilink connection will display on the Network Connections window. 16. Select (click) the Multilink 1 connection. 17. Select the Settings button.

  • Carrier Access Adit 3500, Adit 3500 - Release 1.6 13 Quick Start Guide Installation #1 Adit 3500 mounted on top of the Battery Backup This method will use a minimal amount of wall space. Note: This installation will require a minimum wall space of space of: 9" (H) x 14" (W) x 5" (D). 1. Mount the Battery Backup to the wall with (4) #6 x 1 coarse thread screws Note: Screws are not provided z Mark the location for the top 2 screws (using BBU mounting keyhole as a guide) z Screw these 2 screws into the wall at marked locations. Note: do not screw tight to the wall, leave 1/4" to allow BBU mounting keyholes to slip over screw head. z Attach the BBU by slipping the screw head

  • Carrier Access Adit 3500, 34 Adit 3500 - Release 1.6 Quick Start Guide Basic Configuration 9. Set the following on the Configure Serial 1 window: - Network Type to WAN (this is the default setting) - PPP Authentication to your required preferences 10. Select OK to apply the new settings and exit this window. 11. Select OK again to return to the Network Connections window.

  • Carrier Access Adit 3500, Adit 3500 - Release 1.6 31 Quick Start Guide Basic Configuration Configure WAN Interface for Internet Connectivity There are options to this WAN configuration. This is the connection to the end user’s internet provider. It can be the following: z Single T1 (PPP) z Multiple T1s (Multilink) z Ethernet WAN Single T1 (PPP) To configure a single T1 utilizing PPP: 1. Select Network Connections from the Navigation bar. 2. Select (click) a T1 Interface (from T1 1 - T1 4) to configure, T1 1 is recommended. Note: Using T1 1 and the preconfigured Serial 1 makes this configuration very simple. If you use T1 2-T1 4, you will need to delete the preconfigured Serial 1 and make

  • Carrier Access Adit 3500, 50 Adit 3500 - Release 1.6 Quick Start Guide Basic Configuration 21. Enter the phone number range for numbers to be routed to the trunk interface for incoming SIP calls, on the Call Destination window. Use Strip and Prefix entries to translate the incoming destination number from SIP to the destination number to be sent to the PRI/CAS interface. 22. Select OK to save and exit this window. Note: this information will display at the bottom of the Trunk Settings window. 23. Select OK again to return to the Voice Over IP window.

  • Carrier Access Adit 3500, 48 Adit 3500 - Release 1.6 Quick Start Guide Basic Configuration 14. The current User ID of the FXS lines will display. 15. Select the Line Monitoring tab. This window displays the SIP status of the FXS ports. Note: When a telephone port is successfully registered the Registration Status column displays "Registered" in green." 16. Select the Trunk Settings tab. 17. Select (click) on the trunk to configure. 18. Set the Trunk Signaling type to PRI or CAS.

  • Carrier Access Adit 3500, Copyright 2007 Carrier Access Corporation. All rights reserved. The information presented in this manual is subject to change without notice and does not represent a commitment on the part of Carrier Access Corporation. The hardware and software described herein are furnished under a license or non- disclosure agreement. The hardware, software, and manual may be used or copied only in accordance with the terms of this agreement. It is against the law to reproduce, transmit, transcribe, store in a retrieval system, or translate into any medium - electronic, mechanical, magnetic, optical, chemical, manual, or otherwise - any part of this man

  • Carrier Access Adit 3500, 16 Adit 3500 - Release 1.6 Quick Start Guide Chassis Overview Adit 3500 Battery Backup Power Connector The following cable, is hard wired to the Adit 3500 Battery Backup and connects the Adit 3500. Chassis Overview The following illustrations show all connectors on the Adit 3500. Pinout Wire Definition Red 12V (+) Black 12V (-) (2) 10/100Base-T (4) DS1/E1 (4) Analog (FXS) connectors Alarm Status Reset RS-232 Management Port Power Ground Back Front Battery (E1 Future)

  • Carrier Access Adit 3500, Adit 3500 - Release 1.6 9 Quick Start Guide Installation Wall Mounting Before beginning the mounting process, verify that the installation area is a stable environment, clean and free from extremes of temperature, shock, vibration and EMI. See Installation Environment on page 5. The Adit 3000 is delivered with mounting brackets that can easily be attached for quick and easy wall mounting, as shown in the illustration above. To install the unit to the wall: 1. Attach the wall mount brackets to the Adit 3000, with wall attachment flange pointing away from the unit, as shown above. Attach with 4 screws provided (2 for each bracket). 2. Mount the unit to t

  • Carrier Access Adit 3500, Adit 3500 - Release 1.6 17 Quick Start Guide Interface Connectors Interface Connectors The following are the Adit 3500 interface connectors: Note: The following is dependant upon how the system (hardware) is configured. Systems can be ordered with/without FXS, and can have from 1-4 DS1 ports. Front of Adit z 4 DS1 Ports (used for DS1 WAN and/or PRI/CAS trunks) (RJ-45C connector). - (1) T1-based WAN - uses 1 or 2 DS1 ports - (1) PRI/CAS group - uses 1 or 2 DS1 ports z (1) 10/100Base-TX WAN port (RJ-45 connector) z (1) 10/100Base-TX LAN port (RJ-45 connector) z 4 FXS (RJ-11 connector) Back of Adit z RS-232 craft port connector for local man

  • Carrier Access Adit 3500, 32 Adit 3500 - Release 1.6 Quick Start Guide Basic Configuration 3. Select the Settings button. 4. Set the proper Framing Type and Line Coding. 5. Select OK to apply the new settings and exit this window. 6. Select OK again to return to the Network Connections window.

Related Products and Documents (Network Card):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Nailor 0763 Installation instructions nailor/0763-6FX.pdf 19 Nov 2022 2
2 Aluratek AEBK01F Quick start manual aluratek/aebk01f-YPQ.pdf 18 Jun 2023 2 0.79 Mb
3 Radiodetection RD1500 Quick start manual radiodetection/rd1500-5E8.pdf 05 Aug 2022 2
4 idatastart BM1 Owner's manual idatastart/bm1-57T.pdf 01 Jun 2023 8
5 Man B&W S80ME-C7 Project manual man/b-w-s80me-c7-XHS.pdf 22 Feb 2023 353
6 ATI Technologies DDA SERIES Operating and maintenance manual ati-technologies/dda-series-I82.pdf 24 Jun 2023 8

Similar Resources:

  • Panasonic

    Transistors 2SC3930G

    (5 pages)
    Transistors1Publication date: April 2007 SJC00357AEDThis product complies with the RoHS Directive (EU 2002/95/EC).2SC3930GSilicon NPN epitaxial planar typeFor high-frequency amplificationComplementary to 2SA1532G■ Features• Optimum for RF amplification of FM/AM radios• High transition frequency fT• S-Mini type package, allowing downsizing of the equi …
  • B&B Electronics

    RS-232 Digital I/O Module 232SDD16

    (27 pages)
    232SDD16-1005 Manual Cover Page B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 -- FAX (815) 433-5104 RS-232 Digital I/O Module Model 232SDD16 Documentation Number 232SDD16-1005 pn#3604-r1 This product Designed and Manufactured In Ottawa, Illinois USA of domestic and imported parts by B&B Electronics Mfg. …
  • Renesas

    M16C FAMILY

    (423 pages)
    RENESAS 16-BIT SINGLE-CHIP MICROCOMPUTERM16C FAMILY / M16C/Tiny SERIESM16C/28 Group(M16C/28, M16C/28B)16Rev. 2.00Revision Date: Jan.31, 2007Hardware Manualwww.renesas.comAll information contained in these materials, including products and product specifications, represents information on the product at the time of publication and is subject to change by Rene …
  • Panasonic

    Zener Diodes MAYS0750Y

    (3 pages)
    Zener Diodes Publication date: February 2007 SKE00031AED 1 This product complies with the RoHS Directive (EU 2002/95/EC).MAYS0750YSilicon epitaxial planar typeFor ESD protection of high speed signal line Features Maintain signal cobs with low insertion loss, distortion. Absolute Maximum Ratings Ta = 25°CParameter Symbol Rating UnitTotal power d …
  • 3Com

    ATMLINK 155 PCI

    (130 pages)
    ® ATML INK ™ 155 PCI N ETWORK I NTERFACE C ARDS U SER G UIDE A member of the 3Com family of ATMLink network interface cards Part No. 09-1038-000Published February 1997 …
  • ADC

    Ethernet Distribution Frame TrueNet

    (2 pages)
    www.adc.com • +1-952-938-8080 • 1-800-366-3891Spec SheetTrueNet® Ethernet Distribution FrameADC’s TrueNet® Ethernet Distribution Frame (EDF) forms a central patching location between active Ethernet network elements. By creating a centralized craft interface for adds, upgrades, and rearrangements on Ethernet equipment, the EDF enables change without …

Comments, Questions and Opinions: