Text of Altek SR1128 User Guide:

  • Altek SR1128, SR1128 operation manual ~9~ 3.5 Menu description Code ˄ Main menu ˅ Code (Submenu) Menu Description DT For set the operation temperature difference TEMP For set correlative temperatures EMOF The maximum switch-off temperature of collector EMON The maximum switch-on temperature of collector CMX The maximum temperature of collector (Collector cooling function) CMN Low temperature protection of collector CFR Frost protection of collector REC Tank recooling function SMX1 Maximum temperature of tank1

  • Altek SR1128, SR1128 operation manual ~14~ -------------------------------------------------------------------------------------------------------------------------- ►Press “+” button, “tH 3o 17:00” displays on the screen, to access the submenu of the switch-on time and temperature for the third schedule of heating function. ► Press “SET” button again, “17” of hour time blinks on screen. ►Press “+” “-” button to adjust hour of time. ►Repress “SET” button again, “00” of minute time blinks on screen. ►Press “”“”button to adjust minute of time. ►Repress “SET” button, temper

  • SR1128 operation manual ~4~ Please immediate take the device out of operation. Note: ensure that the device cannot be accidentally placed into operation. 1.4 Important remark We have carefully checked the text and pictures of this manual and provided the best of our knowledge and ideas, however inevitable errors maybe exist. Please note that we cannot guarantee that th

  • Altek SR1128, SR1128 operation manual ~28~ ►Press “ESC” button to exit the menu or wait for 20 seconds to exit automatically, parameters are saved automatically. 5.8 OSDC SD card data save function Description: Put the SD card in the groove, data is logged immediately. Then under menu of the OSDC card, “OSDC ON” displays automatically, it means data is logging, the interval of data log can be set. If card is full, then data logging is stopped, and CFULL displays on the screen. 5.8.1 OSDC Card fu

  • Altek SR1128, SR1128 operation manual ~2~ 5.5 OHQM Thermal energy measuring ....................................................................... 23 5.5.1 FMAX Flow rate ................................................................................................. 24 5.5.2 MEDT Type of heat transfer liquid ...................................................................... 25 5.5.3 MED% Concentration of heat transfer liquid ...................................................... 25 5.6 INTV Pump interval function ................................................................................. 25 5.6.1 ISTAR

  • Altek SR1128, SR1128 operation manual ~8~ z Output ports Input Ports: Input ports L, N is power connection terminal, please connect correctly. is Ground line terminal. Output P1˖Semiconductor relay (SCR relay), for solar circuit pump, also suitable for RPM (speed) control; Max. Switching current: 1A. Output H1˖for by-pass circuit pump or valve, electromagnetic relay, max. switching current 3.5A, R1 ports are always open Note: Depending on the solar system selection, pump and sensors should be connected to the controller are different, all wires should be installed in protection pipe.

  • Altek SR1128, SR1128 operation manual ~20~ CMN signal displays on screen, it indicates that this function is activated. 5.3.5 CFR frost protection of collector Description: In winter when the temperature of collector is below the preset frost protection temperature (factory set is 4 o C), solar circuit pump is triggered to transfer hot water from tank to collector and to heat collector by this reversed circuit. And when tank temperature (T2) drops to 6 o C, electrical heater is triggered automatically and it keeps running until tank temperature T2 raises up to 21 o C or it is stopped when program of CFR is exited. When collector temperature rises u

  • Altek SR1128, SR1128 operation manual ~23~ Setup steps: To access PUMP, then select submenu DTS “DTS 08 o C” displays on screen. ►Press “SET” button, parameter “08 o C” blinks on the screen ►Press “+” “-” button, to adjust the standard DTS, adjustable range ˄2 o C̚30 o C˅, factory set is 08 o C ►Press “ESC” button to exit the menu or wait for 20 seconds to exit automatically, parameters are saved automatically. 5.4.2 RIS Gain for circulation pump 1 (speed adjusting) Setup steps: To access menu PUMP, then select submenu RIS, “RIS

  • Altek SR1128, SR1128 operation manual ~6~ 1 x RS485 remote control connection x Outputs˖1 PWM output˄≤200W˅; 1 relay output ( each available power≤300W˅ x Ambient temperature˖-10-50 o C x Water proof grade˖IP40 Note: SD card isn’t included within the delivery scope of controller. 3. Installation Controller can only be installed indoors, far away from dangerous place and away from the electromagnetic field. 3.1 Installing controller Note: the controller can only be mounted in an area havin

  • Altek SR1128, SR1128 operation manual ~24~ ►Press “SET” button, parameter “OFF” blinks on the screen ►Repress “SET” button to activate this function, then “OHQM ON” appears on the screen ► Press “ESC” button to exit the menu or wait for 20 seconds to exit automatically, parameters are saved automatically. Thermal energy got in current day, accumulative thermal energy and operation time of pump can be reset, doing like following. Operation steps: under standby status, ►Press “+” “-”

  • Altek SR1128, SR1128 operation manual ~27~ set is “30 minute” ► Press “+” “-” button, to adjust time, adjustable range (2~ 60 minutes). ► Press “ESC” button to exit the menu or wait for 20 seconds to exit automatically, parameters are saved automatically. 5.6.4 IRUN Pump running time Setup steps: To select submenu IRUN, “IRUN 15” displays on the screen. ► Press “SET” button, parameter “15” displays and blinks, factory set is “15 seconds” ► Press “+” “-” button, to adju

  • Altek SR1128, SR1128 operation manual ~5~ Picture 3 Picture 4 2.2 Scope of delivery x 1 x controller x 1 x user manual x 2 x screw and dowel x 1 x PT1000 sensor (φ6*50mm,length of cable 1.5 meter˅ x 2 x NTC10K˄φ6*50mm, length of cable 3 meter˅ x 1 x bag of strain relief 2.3 Technical data x Material of cases: ABS x Available ambient temperature: 0 ... 40 o C x Dimensions: 188 x 138 x 43 mm x Mounting: on wall or in the electrical cases x Operation button: 6 operation buttons on panel x Functions: controller used in solar hot w

  • Altek SR1128, SR1128 operation manual ~25~ 5.5.2 MEDT Type of heat transfer liquid MEDT: type of heat transfer liquid, adjustable range (00̚03)ˈ factory set ˖01 Type of heat transfer liquid: 00˖Water 01˖Propylene glycol 02˖Glycol 03˖Tyfocor LS/G-LS Setup steps: To select submenu MEDT, “MEDT 01” displays on screen. ►Press “SET” button, parameter “01” blinks on the screen ►Press “+” “-” button, to adjust type of heat transfer liquid, adjustable range (00̚03˅ ► Press “ESC” button to exit the menu or

  • SR1128 operation manual ~18~ 5.3.2 EMON Collector maximum switch-on temperature (for collector emergency close function) Setup steps: To access main menu TEMP, then select submenu EMON, “EMO 120 o C” displays on screen ►Press “SET” button, parameter “120 o C” blinks. ►Press “+” “-” button, to adjust this maximum switch-on temperature, adj

  • Altek SR1128, SR1128 operation manual ~36~ in system and incorrect operation, the quality responsibility is invalid for them. The warrantee expires within 24 months after the date of purchasing the controller. 10. Accessories A01: sensor for collector PT1000ˈФ6*50mm A02: sensor for tank and pipe NTC10KˈB=3950ˈФ6*50 A05˖˖stainless steel thermowell Parameter˖1/2’ OTˈФ8*200 USB to RS485 Converter Digital flow meter

  • SR1128 operation manual ~19~ circulation or when tank temperature rises its emergency temperature (95 o C). When displays, and blinks on the screen, it indicates that tank emergency temperature reaches, tank temperature is ≥95ć Setup steps: To access main menu TEMP, then select submenu CMX, “CMX 110 o C” displays on screen ►Press “SET”

  • Altek SR1128, SR1128 operation manual ~35~ Symptoms Secondary symptoms Possible cause Procedure Controller does not appear any functions at all Display shows nothing, no display illumination Controller power supply is interrupted or program is out of work Check the controller power cable and fuse The solar pump doesn’t operate, despite the fact that switch -on conditions are satisfied The pump symbol on the display blinks Pump power supply is interrupted Check t

  • Altek SR1128, SR1128 operation manual ~1~ Content 1. Safety information .................................................................................................... 3 1.1 Installation and commissioning ............................................................................... 3 1.2 About this manual ................................................................................................... 3 1.3 Liability waiver .................................................................................................

  • Altek SR1128, SR1128 operation manual ~17~ Tem. Code Function of temperature Adjustable range Factory set Function exit tem. Paragraph EMOF Collector maximum switch - off temperature (ON+3 o C)~ 200 o C 130 o C 5 .3.1 EMON Collector maximum switch - on temperature 80 o C ~ (OF-3 o C) 120 o C 5 .3.2 CMX Maximum limited collector temperature (collector cooling function) 70 o C ~190 o C 110 o C 107 o C 5 .3.3 CMN Low temperature protection of collector 0 o C~90 o C --- 5 .3.4 CF R Frost p

  • SR1128 operation manual ~34~ 8. Trouble shooting 8.1 Trouble protection a. When there is a break or short circuit between the connection of temperature sensors, controller switches off the corresponding functions and no more output signals are given, at the same time error signals show on the display. If controller does not work correctly, please chec

  • Altek SR1128, SR1128 operation manual ~30~ screen, H1 output is switched-on ►Repress “SET” again, “HND2 off” displays, H1 output is switched-off ►Press “ESC” to exit H1 setup. -------------------------------------------------------------------------------------------------------------- Note: when manual mode is activated, signal displays on the screen, after 15 minutes all outputs are switched-off, controller exits manual mode automatically. 5.11 REST Recovery to factory set Setup steps: To access main menu REST, ►Press “SET” button

  • Altek SR1128, SR1128 operation manual ~33~ 7 Protection function 7.1. Memory protection In case power failure occurs, controller keeps the parameter settings unchanged. 7.2 Screen protection When no any press on button for 3 minutes, screen protection is activated automatically, and then LCD lighting lamp is switched-off. Through press any button to light LCD lamp again. 7.3 pump idling protection Pump station monitors that no flow is in the circuit pipe within 3 minutes, then system pump is ceased, "P1" blinks on the screen, through this function, pump is prevented from damaging caused by pump idling. ˖reasons fo

  • Altek SR1128, SR1128 operation manual ~16~ years’ experience, only in special application cases it needs to be changed, (e.g. far distance heat transferring), normally we recommend using default set. Switch-on and switch-off DT are alternating set. To avoid mistake the minimum difference between two temperature differences (ΔTon –ΔToff) is set as 2 o C. Setup temperature difference: Under standby, following steps descript in paragraph 6.1 to access main menu DT ►Press “SET” button, to access settings program of main menu DT, “DT 1o 08 o C” displays on screen, “08 o C” blinks, the first switch-on temperature difference can be set. ►P

  • Altek SR1128, SR1128 operation manual ~26~ at ISTAR and IEND submenu. Setup steps: To select submenu INTV, “INTV” displays on the screen. ► Press “SET” button to access menu, “INTV OFF” displays. ► Repress “SET” button, parameter “OFF” blinks, factory set is “OFF” ► Press “SET” button, to activate this function, then “INTV ON” displays on the screen. ► Press “ESC” button to exit the menu or wait for 20 seconds to exit automatically, parameters are saved automatically. 5.6.1 ISTAR Turn-on time set for pump interval running function Setup steps: To select submenu ISTAR, “ISTAR 07:00” displays on the screen. ►

  • Altek SR1128, SR1128 operation manual ~13~ ►Press “+” button, “tH 1F 05:00” displays on the screen, to access the submenu of the switch-off time and temperature for the first schedule of heating function. ► Press “SET” button again, “05” of hour time blinks on screen. ►Press “+” “-” button to adjust hour of time. ►Repress “SET” button again, “00” of minute time blinks on screen. ►Press “”“”button to adjust minute of time. ►Repress “SET” button, temperature “45ć” blinks on screen. ►Press “”“”button, to set the switch-off temperature of heating. ►Then, press “ESC�

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sharp AF-R140CX Supplemental service manual sharp/af-r140cx-275.pdf 17 Apr 2023 8
2 Norton CM 351 Operating instructions manual norton/cm-351-59D.pdf 08 Nov 2022 16
3 GE PSS25NGN and Dimension manual ge/pss25ngn-and-L6C.pdf 22 Aug 2023 2 0.07 Mb
4 Blodgett MT3270 Manual  blodgett/mt3270-DEV.pdf 05 Nov 2023 2 0.15 Mb
5 Yamaha YZF-R1SV Assembly manual yamaha/yzf-r1sv-NK7.pdf 12 Oct 2023 26
6 Acer AcerPower 4100 Getting started manual acer/acerpower-4100-Z2U.pdf 10 Oct 2023 19 0.34 Mb

Similar Resources:

  • Watchguard

    V10

    (4 pages)
    WatchGuard WatchGuard WatchGuard WatchGuardFirebox VclassFirebox VclassFirebox VclassFirebox VclassQuickStart GuideQuickStart GuideQuickStart GuideQuickStart GuideThank you for purchasing the WatchGuard Firebox Vclass. The Firebox Vclass acts as a barrier between your networks and the public Internet, protecting them from security threats. This QuickStart G …
  • Sprint

    Merlin S720

    (4 pages)
    Note: Before using the device in your Applecomputer, you must do the following on a Windows-based PC (described in this document):If you’ve received the device from Sprint activated and locked: unlock the deviceIf your device has not been activated: activate itAfter Sprint sets up your account on the network,your device is activated and ready to use on you …
  • Bluepath

    netgenie

    (5 pages)
    Bluepath Setup Guides replacing a bt home hub & bt openreach modem with the netgenie router.docx 1 January 2014 Bluepath Setup Guides Replacing a BT Openreach Modem and Router with the NetGenie Smart Home Router. Before installing the NetGenie, please refer to the NetGenie Quick Start Guide and familiarise yourself its pages. This guide applies …
  • DeWalt

    DWP610

    (7 pages)
    Definitions: Safety Guidelines The definitions below describe the level of severity for each signal word. Please read the manual and pay attention to these symbols.DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.WARNING: Indicates a potentially hazardous situation which, if not avoided, could …
  • NETGEAR

    DG834GV

    (106 pages)
    202-10169-01 September 2006NETGEAR, Inc.4500 Great America Parkway Santa Clara, CA 95054 USAReference Manual for the Integrated ADSL Modem and Wireless Router with Voice, Model DG834GV …
  • ATTO Technology

    1550D

    (2 pages)
    Product Features Technical Specification For More Information: www.ATTOTech.com or to Purchase: www.ATTOStore.com (716) 691-1999 iPBridgeTM 1550D iSCSI-to-SCSI High Performance Bridge for Cost-effective IP SAN Connectivity Internet SCSI technology (iSCSI) is one of today’s fastest growing storage networking protocols. iSCSI utilizes Ethernet netw …

Comments, Questions and Opinions: