Manualios.com

ClearOne Unite 200 Operation & User’s Manual

ClearOne Unite 200 Manual Online:

3.05, 2099 votes
ClearOne Unite 200 User Manual
ClearOne Unite 200 User Guide
ClearOne Unite 200 Online Manual

Text of ClearOne Unite 200 User Guide:

  • ClearOne Unite 200, 29 UNITE 200: User Guide 7) I key frame interval: Set interval between 2 I frame. The bigger the interval, lower the response will be from viewing window. 8) Bit Rate control Options: Constant bit rate: video coder will be coding according to preset speed Variable bit rate: video coder will adjust the speed based on preset speed to gain the best image quality 9) Fluctuate level Restrain the fluctuation magnitude of variable rate. Options: 1 - 6 6.3. Image Setup, Click “Image.” 1)

  • ClearOne Unite 200, 14 UNITE 200: User Guide IR REMOTE CONTROL 0. Standby Button Press this button to enter standby mode. Press it again to enter normal mode. NOTE: Power consumption in standby mode is approximately half of the normal mode. 1. Position Buttons To set preset or call preset 2. * Button 3. Set/Clear Preset Buttons Set preset: Store a preset position [SET PRESET] + Numeric button (0-9): Setting a corresponding numeric key preset position NOTE: Preset 0-9 via remote control and the rest from web, keyboard and the

  • ClearOne Unite 200, 4 UNITE 200: User Guide CONTENTS PREFACE .............................................................................................................. 5 PRECAUTIONS .................................................................................................... 5 SUPPLIED ACCESSORIES ................................................................................ 6 QUICK START....................................................................................................... 7 FEATURES ........................................................................

  • ClearOne Unite 200, 28 UNITE 200: User Guide in or zooming out. Focus In/ Focus Out: Focusing on distant objects or Focusing on close objects. 4) Set/Call: When PTZ has been set to a desired position, you can save that configuration as a preset for later use. Click the “Set” button to save a preset. At any point later, you can click the “Call” button to call this preset. 6.2. Media For Video Setup, Select "Video". 1) Video format Supports 50HZ (PAL) and 60HZ (NTSC), and Dia

  • ClearOne Unite 200, UNITE ® 200 CAMERA U SER GUIDE NOTE: For the UNITE 200 camera’s control, use the COLLABORATE Codec Appliance’s remote control. The remote control that comes with this camera is only for advanced configurations, if required.

  • 17 UNITE 200: User Guide SERIAL COMMUNICATION CONTROL In default working mode, the camera can be controlled via RS232 or RS485 (half-duplex mode). The parameters are as follows: Baud rate: 2400/4800/9600 bit/s. Start bit: 1 bit. Data bit: 8 bits. Stop bit: 1bit. Parity bit: none. When the camera initializes, Pan-Tilt rotates to the maximum position of top righ

  • 24 UNITE 200: User Guide IP FUNCTION 1. Operating Environment Operating System: Windows 7/8/8.1/10 Note: Using the included utility programs requires Windows, but using the Web interface does not require any particular operating system. Network Protocol: TCP/IP 2. Equipment Installation 1) Connect the camera to your network or to your PC directly via an Ethernet cable. No

  • ClearOne Unite 200, 5 UNITE 200: User Guide PREFACE This manual introduces the function, installation, and operation of the UNITE 200 camera. Prior to installation and usage, please read the manual thoroughly. PRECAUTIONS This product can be used only under the specified conditions in order to avoid any damage to the camera:  Don’t subject the camera to rain or moisture.  Don’t remove the cover; otherwise, you may get an electric shock. In case of abnormal operation, contact ClearOne Technical Support.  Never opera

  • ClearOne Unite 200, 26 UNITE 200: User Guide After login, the Web interface appears, as shown below: NOTE: If this is the first time using the web interface, you must install the VLC player software. 5. Access the camera though WAN. 5.1. Dynamic DNS setup for accessing the camera Once you have set a domain name to camera, and forwarded the traffic to the traffic to the correct address and port number, then you can use a domain name to access camera. Access link: http://hostname: port number. For example, set up host computer name as: youdomain.f3322.org, camera port number: 554. Access link would be: http://youdomain.f3322.org:554.

  • ClearOne Unite 200, 25 UNITE 200: User Guide Method 1: a. Open the camera’s Web interface (see Access Camera’s Web Interface later in this Manual for detailed instructions). b. On Web interface page, find “Network”--->Change IP. Enter a new IP address, then Click “Apply”. c. Restart camera. Method 2: Run “upgrade_En.exe”, change the IP address, and then click “Set”. The camera will restart. 4.2. Access camera’s web Input http://192.168.100.88 into a browser (Internet Explorer and Firefox work best). Note: If you have changed the

  • ClearOne Unite 200, 9 UNITE 200: User Guide FEATURES  72.5°Wide-angle Lens 72.5° wide-angle,high-quality lens; supports 12x optical zoom.  USB 3.0 USB3.0 ultra-high speed interface; can transfer uncompressed original video, and downward compatible with USB2.0. The USB, HDMI, and Network interfaces can output at the same time.  AAC Audio Encoding Supports audio line input. Supports AAC audio encoding, for better sound quality and lower bandwidth.  H.265 Support Supports H.265 encoding, enabling full HD 1080p/60fps video stream at ultra-low bandwidth.  1080P Full HD A 1/2.7 inch, 2.07 million effective pixels high quality

  • ClearOne Unite 200, 7 UNITE 200: User Guide QUICK START Step 1. Please ensure connections are correct before starting Step 2. Setting of the bottom switches Set both of the switch1 and switch2 to ‘OFF’. That is ‘Normal Working Mode’. SW-1 SW-2 Mode 1 OFF OFF Normal Working Mode 2 ON OFF - 3 OFF ON - 4 ON ON -

  • ClearOne Unite 200, 6 UNITE 200: User Guide SUPPLIED ACCESSORIES When you unpack, check that all the supplied accessories are included:  Camera  AC power adapter  Power cord  RS232 cable  Remote controller  User manual  USB3.0 Cable

  • ClearOne Unite 200, 34 UNITE 200: User Guide 3. Check the server's IP address and subnet mask and gateway address. 4. Check for MAC address conflicts. 5. Make sure the HTTP port isn’t occupied by other devices, or that routing rules aren’t sending the traffic to a different address or port. IP address modified incorrectly or forgot Web interface password You can recover access to the camera using the IR remote control. Press "[*] + [#] + [Manual]" to restore the default values (default IP: 192.168.100.88, default

  • ClearOne Unite 200, 10 UNITE 200: User Guide PRODUCT SPECIFICATION Details Model UNITE™ 200 Name UNITE™ Full-HD Video Conference Camera Camera Video System HD: 1080p/60, 1080p/50, 1080i/60, 1080i/50, 1080p/30,1080p/25, 720p/60, 720p/50, 720p/30, 720p/25 Sensor 1/2.7 inch, CMOS, Effective Pixel: 2.07M Scanning Mode Progressive Lens 12x, f3.5mm - 42.3mm, F1.8 - F2.8 Minimal Illumination 0.05 Lux @ (F1.8, AGC ON) Shutter 1/30s - 1/10000s White Balance Auto, Indoor, Outdoor, One Push, Manual Backlight Compensation Support Digital Noise Reduction 2D&3D Digital Nois

  • 30 UNITE 200: User Guide After adjusting any parameters, click “Apply” to save the settings or click “Cancel” to cancel the adjustment of the parameters. Click “Default” to revert to the default value. 6.4. Audio Setup, Click “Audio.” 1) Audio Type Option: AAC. 2) Sample rate Options: 44.1K and 48K. 3) Bit rate Options: 96K

  • ClearOne Unite 200, 27 UNITE 200: User Guide 6. IP Camera parameter setup 6.1. Homepage introduction Menu All pages include two menu bars: Real time monitoring: displaying video image Parameter setup: with function buttons Video viewing window Video viewing window must be same as video resolution; the bigger the resolution, the bigger the playing area. Double-click the viewing window to show full-screen; double-click again to return to initialized size. PTZ Setup 1) Pan-Tilt control: Up, Down, Left, Right,Home button as shown above. 2) Rate: Vertical speed can be chosen as 1 - 24,

  • ClearOne Unite 200, 23 UNITE 200: User Guide agreement,AUTO, VISCA protocol Options: 1 - 7 P_D_Address: PELCO-D protocol. Options: 0-254 P_P_Address: PELCO-P protocol. Options: 0-31 V_AddrFix: The switch you can change camera uart address. Options: On, Off (When set to On, the 88 30 01 FF command is invalid.) Net Mode: Set the serial port control networking. Options: Serial, Paral Baudrate: Serial port baud rate. Options: 2400, 4800, 9600 8. RESTORE DEFAULT Select Restore Default in the main menu and press the [HOME] button. The RESTORE DEFAULT menu appears, as shown in the following figure: Restore

  • ClearOne Unite 200, 12 UNITE 200: User Guide Power Consumption 12W (Max) Dimensions 240mm x 144mm x 160mm Weight 1.65Kg (3.6lb) MAIN UNIT 1. Lens 11. RJ45 Interface 2. Sensor for the Remote Control 12. Reserved Interface 3. Power Lamp 13. Line In Interface 4. Standby Lamp 14. Reserved Interface 5. Bottom Switches 15. HDMI Interface 6. Tripod Screw Hole 16. USB 3.0 7. Fixing Screw Hole 17. Reserved Interface 8. System Select Switch 18. DC IN 12V Interface 9. RS232 OUT Interface 19. POWER Switch 10. RS232 IN Interface

  • 18 UNITE 200: User Guide CameraWindows DB-9 Camera In Camera Out 1. DTR 1.CD 1. DTR 1.DTR 2. DSR 2.RXD 2. DSR 2.DSR 3.TXD 3.TXD 3. TXD 3.TXD 4.GND 4.DTR 4. GND 4.GND 5.RXD 5.GND 5. RXD 5.RXD 6.RS485- 6.DSR 6. RS485- 6.GND 7.IR OUT 7.RTS 7. IR OUT 7.NC 8.RS458+ 8.CTS 8. RS485+ 8.NC 9.RI Network configuration Under VISCA Under Pelco-D/P

  • ClearOne Unite 200, 8 UNITE 200: User Guide Step 3. Set the Video System Switch to the desired setting Video format options: VIDEO SYSTEM 0 1080p60 8 720p30 1 1080p50 9 720p25 2 1080i60 A - 3 1080i50 B - 4 720p60 C - 5 720p50 D - 6 1080p30 E - 7 1080p25 F - NOTE: After changing the switch, you need to restart the camera to take effect. Step 4. Press the ON/OFF button to turn on the camera. Step 5. When the camera starts, Pan-Tilt rotates to the maximum position of top right, then it returns to the center position. The initialization process is finished. NOTE: If the position pre

  • ClearOne Unite 200, 20 UNITE 200: User Guide On, Off. DRC: Dynamic range control strength.Options: 0 - 8. Bright (Effective only when exposure mode is Bright): Exposure bright level, Options: 0 - 17. Anti-Flicker (Effective only when exposure mode is Auto/Bright): Options: Off, 50Hz, 60Hz. Iris (Effective only when exposure mode is Manual / AAE): Aperture value. Options: F1.8, F2.0, F2.4, F2.8, F3.4, F4.0, F4.8, F5.6, F6.8, F8.0, F9.6, F11.0, Close. Shutter (Effective only when exposure mode is Manual /SAE): Shutter value. Options: 1/30,1/60, 1/90,1/100,1/125,1/180,1/

More Instructions:

DOWNLOAD

Related Products and Documents (Webcam):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Zooper PBTA-200 Operation & user’s manual zooper/pbta-200-MPB.pdf 17 Jun 2022 6 0.6 Mb
2 FujiFilm A600 Quick start fujifilm/a600-LD7.pdf 12 Sep 2022 2 0.6 Mb
3 Fluke Q-RPT Instruction sheet fluke/q-rpt-474.pdf 19 Mar 2023 4 0.27 Mb
4 Craftsman 139.53661SRT3 Owner's manual craftsman/139-53661srt3-6SL.pdf 28 Jul 2022 40 2.22 Mb
5 Samsung BX2031 Manual del usuario samsung/bx2031-LXA.pdf 10 Jan 2024 67 2.51 Mb
6 Night Owl NOPEN-4GB-B Instruction manual night-owl/nopen-4gb-b-659.pdf 14 Aug 2023 8

Similar Resources:

  • i3-TECHNOLOGIES

    i3CAMERA PRO

    (2 pages)
    1 Product Appearance2 Packing List4 Product Featuresat a maximum of 30 frames per second. Other available reso-lutions include 1080p (default), 720p, and other resolutions.Fully featured USB 3.0 interface, power supply, video and au-dio connection in one. It also supports two channels of video signal, and one channel of audio source.Wide Dynamic Range-ent …
  • PTZ Optics

    Webcam v2

    (9 pages)
    Please check PTZOPTICS.com for the most up to date version of this document Rev 1.0 9/20 PTZOptics Webcam v2 User Manual Model No: PT-WEBCAM-80-v2 V1.0 (English) …
  • König Electronic

    CMP-WEBCAM3D10

    (72 pages)
    CMP-WEBCAM3D10MANUAL (p. 2)3D Webcam with 3D glassesMODE D’EMPLOI (p. 12)Webcam 3D avec lunettes 3D MANUALE (p. 22)Webcam 3D con occhiali 3D BRUKSANVISNING (s. 42)3D Webcam med 3D-glasögonMANUAL DE UTILIZARE (p. 52)Cameră web 3D cu ochelari 3D BRUGERVEJLEDNING (p. 62)3D videokamera med 3D linseHASZNÁLATI ÚTMUTATÓ (o. 32.)3D webkamera 3D szemüvegKÄYT …
  • Philips

    SPC 300NC

    (2 pages)
    For preview purpose onlySimply superior performance!Live video messagingIf you want to get into the fascinating world of face-to-face video chatting and video mails, the SPC 300NC is the smart way to get on-line and share the live action. It comes with everything you need, including v-mail software.High picture & video quality• VGA snapshot resolution …
  • PTZOptics

    PT-WEBCAM-80-v2

    (9 pages)
    Rev 1.0 9/20 Please check PTZOPTICS.com for the most up to date version of this document PTZOptics Webcam v2 User Manual Model No: PT-WEBCAM-80-v2 V1.0 (English) …
  • Lindy

    42950

    (2 pages)
    USB 2.0 WebCam User Manual English Benutzerhandbuch Deutsch Manuel Utilisateur Français Manuale d’uso Italiano LINDY No. 42950 www.LINDY.com © LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - FIRST EDITION (Aug-2004) English Manual Deutsches Benutzerhandbuch Driver Installation P …

Comments, Questions and Opinions: