  • Cooper&Hunter CH-S09FTXN, Clean and Maintenance 1. Check whether air inlets and air outlets are blocked. 2. Check whether air switch, plug and socket are in good condition. 4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer. 5. Check whether drainage pipe is damaged. 1. Disconnect power supply. 3. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer. Notice for recovery 1. Many packing materials are recyclable materials. Please dispose them in appropriate recycling unit. 2. If you want to dispose the air conditioner, please contact local dealer or consultant

  • Cooper&Hunter CH-S09FTXN, 6 (Display content or position may be different from above graphics, please refer to actual products) Parts Name Indoor Unit Outdoor Unit remote control air inlet panel horizontal louver air outlet heating indicator temp. indicator cooling indicator power indicator receiver window aux.button drying indicator display air inlet handle air outlet NOTICE: Actual product may be different from above graphics, please refer to actual products. FAN AUTO OPER HEALTH AIR FILTER TURBO ON/OFF X-FAN HOUR HUMIDITY ON/OFF MODE FAN X-FAN TURBO TEMP TIMER SLEEP LIGHT

  • Cooper&Hunter CH-S09FTXN, Step six: neaten the pipes 1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Min. semidiameter of bending the pipe is 10cm. 2. If the outdoor unit is higher than the wall hole, you must set a U-shaped curve in the pipe before pipe goes into the room, in order to prevent rain from getting into the room. ● The through-wal height of drain hose shouldn't be higher than the outlet pipe hole of indoor unit. ● Slant the drain hose slightly dow- nwards. The drain hose can't be curved, raised and

  • Cooper&Hunter CH-S09FTXN, 13 Operation guide 1. After putting through the power, press " " button on remote controller to turn on the air conditioner. 2. Press " " button to select your required mode: AUTO, COOL, DRY, FAN, HEAT. 3. Press "+" or "-" button to set your required temperature. (Temperature can’t be adjusted under auto mode). 4. Press " " button to set your required fan speed: auto, low, medium and high speed. 5. Press " " button to select fan blowing a

  • Cooper&Hunter CH-S09FTXN, Do not block air outlet or air inlet. It may cause malfunction. remote controller may be broken. ● Power cord is overheating or damaged. ● There’s abnormal sound during operation. ● Circuit break trips off frequently. ● Air conditioner gives off burning smell. ● Indoor unit is leaking. contact the dealer or qualified professionals for service. When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal. outlet. It may cause personal injury or damage. Precautions WARNING conditioner and disconnect power

  • Cooper&Hunter CH-S09FTXN, 10 HEALTH SAVE button 7 HEALTH FUNCTION: After pressing HEALTH button, remote controller will switch circularly as below: "HEALTH"→"AIR"→"AIR HEALTH"→"no display" ● When selecting "HEALTH" by remote controller, HEALTH function will be started up. ● When selecting "AIR" by remote controller, AIR function will be started up. ● When selecting "AIT HEALTH", AIR and HEALTH function will be started up. ● When there’s no display on remote con

  • Cooper&Hunter CH-S09FTXN, Additional refrigerant charging amount for R22, R407C, R410A and R134a Diameter of connection pipe Liquid pipe(mm) Gas pipe(mm) Φ6 Φ6 or Φ9.52 Φ9.52 or Φ12 Φ12 Φ16 Φ19 Φ22.2 Φ16 or Φ19 Φ19 or Φ22.2 Φ25.4 or Φ31.8 _ _ Cooling only(g/m) Cooling and heating(g/m) 15 15 30 60 250 250 350 350 120 120 50 20 Outdoor unit throttle Conguration of connection pipe 35

  • Cooper&Hunter CH-S09FTXN, Pipe expanding method Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: A: Cut the pipe ● Conrm the pipe length according to the distance of indoor unit and outdoor unit. ● Cut the required pipe with pipe cutter. pipe pipe cutter leaning uneven burr B: Remove the burrs ● Remove the burrs with shaper and prevent the burrs from getting into the pipe. downwards pipe shaper C: Put on suitable insulating pipe D: Put on the union nut

  • Cooper&Hunter CH-S09FTXN, 12 Function introduction for combination buttons Introduction for buttons on remote controller TURBO button 11 When pressing this button under cooling or heating mode, air conditioner will enter into quick cooling or quick heating mode. The character of "TURBO" is displayed on remote controller. Press this button again to exit turbo function and the character of "TURBO" will be disappeared on remote controller. SLEEP button 12 Press this button under cooling, heating mode can start up sleep function. " " icon will be displayed on remote controller. Pre

  • Cooper&Hunter CH-S09FTXN, 25 1. Aim the pipe joint at the corresponding bellmouth. 2. Pretightening the union nut with hand. 3. Adjust the torque force by referring to the following sheet. Place the open-end wrench on the pipe joint and place the torque wrench on the union nut. Tighten the union nut with torque wrench. 2. When select leading out the pipe from left or right, please cut off the corresponding hole on the bottom case. cut off the hole left right 1. The pipe can be led out in the direction of right, rear right, left or rear

  • Conguration of connection pipe 1. Standard length of connection pipe ● 5m, 7.5m, 8m. 4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe ● After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for each additional 5m of

  • Cooper&Hunter CH-S09FTXN, 20 Malfunction analysis Error code H1 E5 H4 U8 H6 C5 F1 F2 Troubleshooting Means defrosting status. It’s the normal phenomenon. It can be eliminated after restarting the unit. If not,please contact qualified professionals for service. contact qualified professionals for service. contact qualified professionals for service. contact qualified professionals for service. It can be eliminated after restarting the unit. If not,please It can be eliminated after restarting the unit. If not,please It can be eliminated after restarting the unit. If not, please Please contact qualified professionals for service. Please contact qualified pr

  • Cooper&Hunter CH-S09FTXN, Precautions WARNING Do not connect air conditioner to multi-purpose socket. This appliance can be used by children aged from 8 Operation and Maintenance If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Do not spray water on indoor unit. It may cause electric shock or malfunction. Otherwise, it may cause fire hazard. Children shall not play with the appliance. Cleaning and user maintenance shall not be

  • Cooper&Hunter CH-S09FTXN, 11 Introduction for buttons on remote controller TIMER button 10 ● At ON status, press this button once can set TIMER OFF. The character of HOUR TIMER ON. After each pressing of "+" or "-" button, time will increase or decrease half an Note: ● Outdoor ambient temperature display may can’t be selected for some models. When indoor unit receives " " signal, it displays indoor set temperature. ● Only for the model whose indoor unit has dual-8 display. TEMP

  • 30 Installation of outdoor unit Step four: connect indoor and outdoor pipes 1. Remove the screw on the right han- dle of outdoor unit and then remove the handle. 2. Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe. 3. Pretightening the union nut with hand. 4. Tighten the union nut with torque wrench by referrin

  • Cooper&Hunter CH-S09FTXN, Do install the circuit break. If not, it may cause malfunction. of at least 3mm in all poles should be connected in fixed wiring. magnet buckle and heating buckle function, it can protect the circuit-short and overload. power supply circuit and circuit break. Precautions WARNING note the following table.Air switch should be included Make sure the power supply matches with the requirement of air conditioner.Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner. An all-pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit.

  • Cooper&Hunter CH-S09FTXN, 27 4. Put wiring cover back and then tighten the screw. 5. Close the panel. Installation of indoor unit Note: ● All wires of indoor unit and outdoor unit should be connected by a professional. for a new one. Avoid extending the wire by yourself. installation. ● For the air conditioner without plug, an circuit break must be installed in the line. The circuit break should be all-pole parting and the contact parting distance should be more than 3mm. 3. Remove the wire clip; connect the

  • Check after installation 33 Test operation Items to be checked Possible malfunction The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? (heating) capacity. It may cause condensation and water dripping. Is water drained well? It may cause condensation and water dripping. Is the voltage of power supplyaccord- ing to the voltage ma

More Instructions:

DOWNLOAD

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Whirlpool WGD94HEAW Installation instructions manual whirlpool/wgd94heaw-IB9.pdf 11 Sep 2022 44
2 Pride Mobility C550 Owner's manual pride-mobility/c550-A49.pdf 27 May 2023 27
3 Apple Personal LaserWriter 300 Service source apple/personal-laserwriter-300-5R9.pdf 19 Sep 2022 172 1.89 Mb
4 Aiwa XP-R237 Operating instructions aiwa/xp-r237-S7F.pdf 11 Mar 2023 2 0.27 Mb
5 Sony PCWA-A500 - Wireless Lan Access Point Operating instructions manual sony/pcwa-a500-wireless-lan-access-point-T93.pdf 20 Jul 2023 32 0.44 Mb
6 Harman Kardon CP 35 Quick start manual harman-kardon/cp-35-68S.pdf 27 Jan 2024 4 0.63 Mb

Similar Resources:

  • Fujitsu

    ASU18RLF

    (100 pages)
    SPLIT TYPE ROOM AIR CONDITIONER Models Indoor unit Outdoor unitAOU36RLXFZHAOU45RLXFZINVERTER MULTISERVICE INSTRUCTIONR410ACompact Wall MountedWall Mounted / Floor Compact Cassette / Slim Duct ARU7RLFARU9RLFARU12RLFARU18RLFARU24RLFAUU7RLFAUU9RLFAUU12RLFAUU18RLFASU18RLFASU7RLF1ASU9RLF1ASU12RLF1AGU9RLFAGU12RLFAGU15RLFASU24RLF …
  • Frigidaire

    FRA184MT2

    (13 pages)
    TABLE OF CONTENTSAll about theUse &CareCare and Cleaning .............................................. 11Energy Saving Ideas ........................................... 112020218A0885 (June 2009) Product Registration...........................................................4Packaging 4Normal Sounds ............................................... …
  • Lennox

    13ACX

    (24 pages)
    09/08 506081−01*2P0908* *P506081-01*Page 12008 Lennox Industries Inc.Dallas, Texas, USA RETAIN THESE INSTRUCTIONSFOR FUTURE REFERENCEWARNINGImproper installation, adjustment, alteration,service or maintenance can cause personal injury,loss of life, or damage to property.Installation and service must be performed by alicensed professional installer (or e …
  • Friedrich

    MR18Y3F

    (19 pages)
    SPLIT TYPEROOM AIR CONDITIONERWALL MOUNTEDtypeERROR CONTENTS . . . . . . . . . . . . . . . . . .ModelsIndoor unit Outdoor unitMW18Y3F MR18Y3FCONTENTSSPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . 1OUTLINE AND DIMENSIONS . . . . . . . . . . . 2STANDARD ACCESSORIES . . . . . . . . . . . 17REFRIGERANT SYSTEM DIAGRAM . . . . . 3CIRCUIT D …
  • Frigidaire

    FAX051P7

    (4 pages)
    Product No. FAX051P7A1 FAX051P7A2 FAX051P7A3 FAX051P7A4 FAX051P7A5 FAX051P7A6 Series OPP5 OPP5 OPP5 OPP5 OPP5 OPP5 Color N/A N/A N/A N/A N/A N/A Volts 115 115 115 115 115 115 BTU-Cooling 5000 5000 5000 5000 5000 5000 Owner's Guide 220201d036 220201d036 220201d036 220201d036 220201d036 220201d036 Installation Instructions opp5installen opp5i …
  • EdgeStar

    AP10000HW

    (21 pages)
    Portable Air Conditioner Owner’s Manual This owner’s manual provides instructions on safe installation use, and maintenance. Please read it carefully and save it for reference AP10000H W …

Comments, Questions and Opinions: