Text of ascon A5RT 90 BR User Guide:

  • ascon A5RT 90 BR, 5 Cooling Operating Range Ensure the operating temperature is in allowable range. Heating Caution : The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. 0301 15 -15 -10 20 20 18 10 0 -20 27 Outdoor DB temperature (°C) Indoor WB Temperature (°C) Outdoor WB Temperature (°C) Indoor DB Temperature (°C) 52 50 43 40 20 10 30 0 -10 14 10 20 19 23 30 3.APPLICATIONINFORMATION

  • ascon A5RT 90 BR, 30 50 150 250 350 450 550 650 5300 5800 6300 6800 7300 7800 8300 A IR FLOW )aP( ERUSSERP CITATS LATOT 700 600 Internal Static Pressure Standard Point CFM 3.0 kW 2.2 kW 3.7 kW RPM 2500 2700 2900 3100 3300 3500 3700 3900 L/S 800 900 1000 A5RT180B(R)

  • ascon A5RT 90 BR, 43 3 rd Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 25°C DB, 17°C WB Outdoor Condition: 37°C DB Indoor WB ˚C Indoor DB ˚C Outdoor DB, ˚C 35 TC (kW) SHC (kW) 25 ...... 42.92 35.61 PI (kW) 37 40 TC (kW) SHC (kW) PI (kW) 12.91 40.03 33.60 14.02x y z Total capacity, TC Interpolation Method: ⇒ 40º C – 35º C = 40.03kW – 42.92kW 40.03kW – xkW 40º C – 37ºC ⇒ x = 41.76kW Sensible capacity, SHC Interpolation Method: ⇒ 40º C – 35º C = 33.60kW – 35.61kW 40º C – 37º C ⇒ y = 34.81kW 33.60kW – ykW Power Input, PI Interpolation Method: ⇒ 40º C – 35º C = 14.02kW – 12.91kW 40º C – 37º C �

  • ascon A5RT 90 BR, 1. NOMENCLATURE ..........................................................................................................1 - PRODUCT LINE-UP 2. FEATURES .....................................................................................................................3 3. APPLICATION INFORMATION .......................................................................................5 - OPERATING RANGE - REFRIGERANT CIRCUIT DIAGRAMS - CONTROLLERS - INSTALLATION 4. SOUND DATA ......................................

  • ascon A5RT 90 BR, 17 Special Precautions When Dealing With Refrigerant R410A Unit (1) What is new refrigerant R410A? R410A is a new HFC refrigerant which does not damage the ozone layer. The working pressure of this new refrigerant is 1.6 times higher than conventional refrigerant (R22), thus proper installation / servicing is essential. (2) Components Mixture weight composition R32(50%) and R125(50%) (3) Characteristic R410A liquid and vapor components have different compositions when the � uid evaporates or condenses. Hence, when leak occurs and only vapor leaks out, the composition of the refrigerant mixtu

  • ascon A5RT 90 BR, 22 Outdoor Noise Level 63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz 63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz 91 91 79 78 78 72 68 61 96 91 79 78 80 72 70 64 83 93 90 79 78 80 73 71 64 83 95 96 83 82 84 78 73 66 87 A5RT90BR 77 76 64 65 63 60 55 48 78 75 62 60 59 54 50 44 64 65 77 74 61 60 61 54 52 45 65 63 78 82 66 63 63 56 51 45 68 73 68 66 A5RT120BR A5RT150BR A5RT180BR A5RT90BR 82 A5RT120BR A5RT150BR A5RT180BR Model 1/1 Octave Sound Power (dB, ref 20µPa) Overall Noise Criteria (NC) 1/1 Octave Sound Pressure Level (dB, ref 20µPa) Model Overall (dBA) (dBA) Coil Mic. posit

  • ascon A5RT 90 BR, 34 Electrical Data - Heatpump (R410a) 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. POWER SOURCE V/Ph/Hz RATED INPUT POWER W 1910 2,580 RATED RUNNING CURRENT A 3.7 4.70 MOTOR OUTPUT W 2200 3,000 POWER SOURCE V/Ph/Hz RATED INPUT POWER W 790 780 RATED RUNNING CURRENT A 3.6 3.4 MOTOR OUTPUT W 510 590 POWER SOURCE V/Ph/Hz RATED INPUT POWER W 790 780 RATED RUNNING CURRENT A 3.6 3.4 MOTOR OUTPUT W 510 590 POWER SOURCE V/Ph/Hz CAPACIT

  • ascon A5RT 90 BR, 12 C. Installation When installing the LCD panel to the bracket, 2 petS 1 petS When removing the LCD panel from the bracket, 1 petS 2 petS 1. A 3V DC battery is supplied with the LCD. It is used to ensure that the LCD displays real time once the timer is set. 2. The LCD is wired to the main board via CN8 connection. Hook the LCD panel from the bottom fi rst Push to fasten the LCD panel to the bracket Remove the LCD panel from the top part first Remove the LCD panel

  • ascon A5RT 90 BR, 8 B. Main Menu How to use the Main Menu? Step 1 Press ENTER to view the sub-Menu under Main Menu. Step 2 Go to sub-Menu by pressing the ▲ or ▼ button. Press ENTER to select the sub-Menu. Step 3 Go to parameter to change or view by pressing the ▲ or ▼ button. Press ENTER to select this parameter. Step 4 Change the parameter by pressing the ▲ or ▼ button. Once completed press ENTER. Press ESC to go back to previous screen until you see the initial display screen. Operation Menu Settings Menu Note: The Set Parameter in the setting menu requires password for any changes to or to view its

  • ascon A5RT 90 BR, 45 Model: A5RT150BR Model: A5RT180BR TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 21°C 44.03 29.82 10.49 42.37 29.06 11.10 41.41 28.82 11.95 39.46 27.89 12.68 36.67 26.40 13.77 34.12 25.22 15.25 24°C 44.20 34.76 10.50 42.53 33.98 11.11 41.57 33.82 11.96 39.64 32.93 12.69 36.97 31.10 13.79 34.60 29.48 15.28 27°C 45.14 42.60 10.55 43.59 41.45 11.17 42.78 41.04 12.03 41.00 39.63 12.77 38.48 37.56 13.89 36.28 35.59 15.40 30°C 46.31 46.31 10.66 44.87 44.87 11.30 43.33 43.33 12.18 41.69 41.69 12.94 39.13 39.13 14.06 36.98 36.98 15.58 24°C 48.15 28.14 10.72 46.29 27.41 11.34 45.27 27.20 12.20 43.16 26.39 12.93 40.18 25.04 14.03 37.46 23.96 15.50 27°C

  • ascon A5RT 90 BR, 55 Service Of The Filter Filter Position The filters are mounted in front of the indoor heat exchanger. Unit shown in the diagram is A5RT90BR. Other models shall follow the same method. Remove filter cover for filter service. Alternatively, remove service panel for filter service. Vacuuming And Charging Invert cylinder without dip-pipe Liquid withdrawal Dip-pipe ! CAUTION • R410A must be charged as liquid. Usually R410A cylinder is equipped with a dip-pipe for liquid withdrawal. If there is no dip-pipe, the cylinder should be inverted so as to withdraw liquid R410A from the valve. • Do not top-up when servicing l

  • 33 Electrical Data -Heatpump (R410a) POWER SOURCE V/Ph/Hz RATED INPUT POWER W 800 1,160 RATED RUNNING CURRENT A 1.7 3.10 MOTOR OUTPUT W 1100 1,500 POWER SOURCE V/Ph/Hz RATED INPUT POWER W 560 870 RATED RUNNING CURRENT A 2.5 3.8 MOTOR OUTPUT W 360 550 POWER SOURCE V/Ph/Hz RATED INPUT POWER W 710 870 RATED RUNNING CURRENT A 3.2 3.8 MOTOR OUTPUT W 420 550 POWER SOURCE V/Ph/Hz CAPACITOR µF R

  • ascon A5RT 90 BR, 2 Product Line-up A5RT-BR Series Heat pump Rooftop controller PCB EXV Gold Fin (NA549) Scroll compressor Saranet Air Filter Side flow Convertible Filter Drier High pressure switch Low pressure switch 90BR FXAA X X X XX X X X X X X 120BR FXAA X X X X X X X X X 150BR FXAA X X X X X X X X X 180BR FXAA X X X X X X X X X X X X X X X Heating Nomenclature Classification Model A5RT Heat pump Remarks: Economizers & CO2 sensor will be ready soon.

  • ascon A5RT 90 BR, 48 Model:A5RT120BR DRAIN PIPE ø 1" RETURN AIR FOR HORIZONTAL DISCHARGE VERTICAL RETURN AIR 1.243 1.243 4.6451 1.22 5.89 2113.0 2230.0 57.5 207.3 7.212 630.0 264.8 544.0 650.5 614.3 135.6 249.9 395.1 405.0 1161.3 1069.3 164.3 630.0 146.7 614.3653.3537.5279.6 407.0164.3 FOR VERTICAL DISCHARGE All dimensions are in mm VERTICAL SUPPLY AIR 2180.0 167.8 CENTER OF GRAVITY 980.0 1407.0 SUPPLY AIR Back view of the unit: 2209.0 0.8201 CONTROL BOX

  • ascon A5RT 90 BR, 26 Drive Package A5RT90B(R) Type Diameter(mm) Bore(mm) Diameter(mm) Bore(mm) A5RT90BR SPZ1 160 25 71 24 A5RT120BR SPZ1 160 25 71 24 A5RT150BR SPZ2 160 25 80 28 A5RT180BR SPZ2 180 30 95 28 Pulley Centre Distance, C (mm) Nominal A5RT90BR 1450 545 1.1 1480 A5RT120BR 1600 620 1.5 1520 A5RT150BR 1420 590 2.2 1520 A5RT180BR 1862 715 3.0 1520 Motor Pulley, Dm Motor RPMMotor kWModel Model V-belt length, L(mm) Blower Pulley, Db 0 50 100 150 200 250 300 350 400 450 2600 2800 3000 3200 3400 3600 3800 4000 Air Flow )aP(erusserPcitatSlatoT 800 700 600 500 Internal Static Pressure Standard Point 400 CFM 900 1.5 kW 1.

  • ascon A5RT 90 BR, 28 A5RT120B(R) 50 100 150 200 250 300 350 400 450 500 550 600 3200 3500 3800 4100 4400 4700 5000 5150 Air Flow )aP( erusserP citatS latoT 900 800 700 600 Internal Static Pressure Standard Point CFM 2.2 kW 1.5 kW 1.1 kW MPR L/S 2200 1800 1700 1600 500 1000 1900 2000 2300 2400 2100

  • 59 1 Assy Tubing 2 Assy, Base Pan Main R50084107170 3 Assy, Separator R50014101962 Ins, Separator 3 R06014101995 Ins, Separator 3b R06014101996 Ins, Separator 3c R06014101997 Ins, Separator 3d R06014101998 Ins, Separator 3e R06014101999 Ins, Separator 3f R06014102000 4 Separator 1 R01014101973 Ins, Separator 1 R06014102001 Ins, Separa

  • 56 Causes Power failure. Fuse blown or circuit breaker tripped. Power supply wiring phase incorrect. Protection against frequent starting. Filter is filled with dust and dirt. There are some obstacles at the air inlet or outlet of the units. Dirty air filter. Temperature setting is too low (for cooling). Temperature setting is too high (for heating). Temperature setting is too high (for c

  • ascon A5RT 90 BR, 57 1 Structure, Base Right R01014087427 Support, Structure, Base R01014087430 Assy, Structure Base Back R50014088634 Assy, Structure Base Front R50014094739 Structure, Base Left R01014087428 Structure, Center R01014087432 2 Assy Tubing 3 Assy, Outdoor Base Panel R50014102424 4 Comp, Assy. ZP103KCE-TFD-522 Copeland R50049024296 5 Assy, Separator 5RT90BR R50014102162 Ins., Separator 1 (T10.0x986.0x700.0) R06014104788 Ins, Separator 2 (T10.0x986.0x894.5) R06014102165 Ins, Separator 3 (T10.0x878.6x157.0) R06014102164 6 Assy, Pillar Left Back R50014101430 7 Assy, Pillar Right Back

  • ascon A5RT 90 BR, 32 General Data - Heat pump (R410a) Btu/h 152600 190000 W 44720 55690 Btu/h 142600 184000 W 41790 53930 W 13040 16740 W 12860 15540 A 28.3 30.2 A 26.9 28.8 V/Ph/Hz W/W 3.43 3.33 W/W 3.25 3.47 dBA 75 82 dBA 80 84 AIR DISCHARGE OPERATION AIR FLOW l/s / cfm 2670 / 5650 3160/ 6700 Pa/in.wg. 147 / 0.6 206 / 0.8 mm/in 25.4 / 1 25.4 / 1.0 l/s / cfm 5710 / 12100 6090 / 12900 dBA 83 87 mm/in 1130 / 44.5 1048 / 41.3 mm/in 2209 / 87.0 2209/ 87.0 mm/in 2113 / 83.2 2670/ 105.1 mm/in 1325 / 52.2 1252 / 49.3 mm/in 2304 / 90.7 2304 / 90.7 mm/in 2372 / 93.4 2929 / 115.3 kg/lb 610 / 1345 780 / 1720 kg/lb (7.2 X 2) / (15.9 X 2) (8.7 X 2) / (19.2 X 2) SOUND POWER LEVEL CONTROL

  • ascon A5RT 90 BR, 27 BlowerCurves A5RT90B(R) 0 50 100 150 200 250 300 350 400 450 2600 2800 3000 3200 3400 3600 3800 4000 Air Flow )aP( erusserP citatS latoT 800 700 600 500 Internal Static Pressure Standard Point 400 CFM 900 1.5 kW 1.1 kW 0.75 kW MPR L/S 1800 1500 14001300 1600 1700

  • 39 Details: 1 st Step: Indoor WB ˚C Indoor DB ˚C Outdoor DB, ˚C 35 TC (kW) 16 25 ....................... x 1 y 1 24 41.41 43.48 35.59 41.63 12.81 12.94 27 Total capacity, TC ⇒ ⇒ Interpolation Method: 27º C – 24º C = 43.48kW – 41.41kW 27º C – 25º C x 1 = 42.10kW Sensible capacity, SHC Interpolation Method: ⇒ 27º C – 24º C 27º C – 25º

  • ascon A5RT 90 BR, 47 1.22 0.89 9.1501 1.0661 2063.0 2181.0 45.3 50.5 153.7 171.0 779.0 VERTICAL RETURN AIR VERTICAL SUPPLY AIR 97.1 513.0383.6536.5133.1 408.0 2131.0 171.2 0.0511 1638.0 FOR VERTICAL DISCHARGE All dimensions are in mm CENTER OF GRAVITY BACK VIEW OF THE UNIT 779.0 116.7 544.0 RETURN AIR SUPPLY AIR 369.0 405.0 398.0 872.1 788.1 DRAIN PIPE Ø 1" 379.1 513.0 84.8 179.5 213.5 FOR HORIZONTAL DISCHARGE 3.734 3.734 5.587 1274.5 850.0 Back view of the unit: Model:A5RT90BR 8.DIMENSIONALDATA

  • ascon A5RT 90 BR, While upmost care is taken in ensuring that all details in the publication are correct at time of going to press, we are constantly striving for improvement and therefore reserve the rights to alter model specifications and equipment without prior notice. Details of specifications and equipment are also subject to change to suit local conditions and requirements and not all models are available in every market.

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Fender PR 257 Owner's manual fender/pr-257-2BT.pdf 29 Aug 2023 4 0.23 Mb
2 Polycom SpectraLink 8002 Series Specifications polycom/spectralink-8002-series-2TT.pdf 20 Nov 2022 2
3 Dcm Time Frame TF400 Series Two Owner's instructions dcm/time-frame-tf400-series-two-LVE.pdf 10 Nov 2022 3 0.45 Mb
4 Kyocera Ecosys FS-1200 Operation & user’s manual kyocera/ecosys-fs-1200-45X.pdf 08 Sep 2023 119
5 Flymo Mini-Trim Trimmer I Instruction manual flymo/mini-trim-trimmer-i-91L.pdf 01 Sep 2023 15 0.19 Mb
6 Foscam FI8918W Quick installation & user manual foscam/fi8918w-ZRA.pdf 29 Mar 2023 18 1.29 Mb

Similar Resources:

  • Taurus

    ALPATEC AC2600 RVKT

    (160 pages)
    CatalàAC2600 RVKTAire Acondicionado portátilPortable air conditioningClimatiseur portableMobiles KlimagerätCondizionatore portatileAr condicionado portátilDraagbare airconditioningKlimatyzator przenośnyΦορητό κλιματιστικόПортативный кондиционерAparat de aer condiţionat portabilПреносима климатич …
  • Rubbermaid

    Thermo-Electric Travel Cooler and Warmer

    (5 pages)
    Thermo-ElectricTravel Cooler™and Warmer VEC213RBOWNER’S MANUAL & WARRANTY INFORMATIONIMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONSTHIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THEOPERATION AND WARRANTY OF THIS PRODUCT. PLEASE READ CAREFULLYBEFORE USE AND RETAIN FOR FUTURE REFERENCEwww.vectormfg.comRubbermaid®is a registered trademark …
  • Marstair

    CKC 15 1/50

    (20 pages)
    1 55008418-03 TECHNICAL MANUAL CKC CONDENSING UNITS …
  • Perlick

    US4KP

    (12 pages)
    MODEL NOS.US4KPUS10KPINSTALLATION AND OPERATION INSTRUCTIONSUTILITY COOLERSTable of ContentsCabinet Specifications ......................................... 2Preparing for Assembly Tools Required .................................................... 3Pre-Assembly ....................................................... 3Placing the Utility Cooler ............ …
  • Samsung

    ASHM070VE

    (26 pages)
    OWNER’S INSTRUCTIONSMANUAL DE INSTRUCCIONESISTRUZIONI PER L’USOMANUAL DE INSTRUÇÕESMANUEL D’UTILISATIONGEBRAUCHSANWEISUNGMULTI-SPLIT TYPE ROOM AIR CONDITIONER( Cool and Heat )ACONDICIONADOR DE AIRE DOMÉSTICO SISTEMA MULTI SPLIT( Refrigeración y Calefacción )CONDIZIONATORE D’ARIA PER PIÙ AMBIENTI AD UNITÀ SEPARATE( Raffreddamento e Riscaldament …
  • Elektronika

    SCM60ZD-S

    (82 pages)
    1(OUTDOOR UNIT)SCM60ZD-S(INDOOR UNIT)SKM22ZD-S STM25ZE-S SRRM25ZE-SSKM25ZD-S STM35ZE-S SRRM35ZE-SSKM28ZD-S STM50ZE-S SRRM50ZE-SSKM35ZD-S STM60ZE-S SRRM60ZE-SSKM50ZD-SSCM-ZD (3room)INVERTER MULTI-SPLIT SYSTEMROOM AIR-CONDITIONER[3room](Air to air heat pump type) …

Comments, Questions and Opinions: