Manualios.com

HP VMA SAN Installation And Configuration Manual

HP VMA SAN Manual Online:

3.55, 1484 votes
HP VMA SAN User Manual
HP VMA SAN User Guide
HP VMA SAN Online Manual

Text of HP VMA SAN User Guide:

  • HP VMA SAN, 26 HP VMA SAN Gateway Installation and Configuration Guide AM456-9025A The fastest way to configure a master or standalone HP VMA SAN Gateway node is with the setup configuration wizard. Note: Interface bonding and cluster VLAN configuration are not included in the configuration wizard setup. For initial cluster setup, or for single-Ethernet cable to Gateway configurations, you can specify the eth1 interface as the “Public interface name” and “Cluster interface name” in the wizard. Then confi

  • HP VMA SAN, AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 63 CHAPTER 6 Multipath Client-Side Configuration This chapter provides examples of client-side multipath setup for the HP VMA SAN Gateway. The following topics are covered: • Multipath Overview on page 60 • Multipath Setup on page 61 Note: The examples in this chapter are guidelines for (client-side) Red Hat Enterprise Linux 5.x DM Multipath. For more information, go to the Red Hat Web site: http://docs.redhat.com/docs/en-US/Red_Hat_Enterprise_Linux/ Multipath Over

  • HP VMA SAN, AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 5 Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 CHAPTER 1. HP VMA SAN Gateway Hardware Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 System Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Planning a Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Defining a Configuration .

  • HP VMA SAN, AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 3 OTHERWISE), FOR ANY DIRECT, INDIRECT, PUNITIVE, INCIDENTAL, RELIANCE, SPECIAL, EX- EMPLARY OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, ANY LOSS OF DATA, LOSS OR INTERRUPTION OF USE, COST OF PROCURING SUBSTITUTE TECHNOLOGIES, GOODS OR SERVICES, OR LOSS OF BUSINESS, REVENUES, PROFITS OR GOODWILL, EVEN IF AD- VISED OF THE POSSIBILITY OF SUCH DAMAGES. Violin Memory, Inc. 685 Clyde Avenue Mountain View, CA 94043USA Compliance notices and information can be found in Compliance Information on page 12. DISCLAIMER Portions of this document are i

  • HP VMA SAN, 76 HP VMA SAN Gateway Installation and Configuration Guide AM456-9025A • The power supply power chord must include a grounding plug and must be plugged into grounded circuit outlets. • Use only one hand when working with powered-on electrical equipment. This helps to avoid creating a complete circuit, thus preventing electrical shock. WARNING! There is a danger of explosion if the onboard battery is installed upside down, as a result of reversed polarities. This battery must be replaced only with the same type of batter,

  • HP VMA SAN, AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 69 APPENDIX A System Specifications This appendix contains the system specifications for the HP VMA Array and HP VMA Array. HP VMA SAN Gateway Specifications Review the following table to plan for a deployment that meets the requirements of your site. 3000 Series Model Violin Memory 3205 Violin Memory 3210 Flash Type SLC SLC Raw Capacity (GiB/GB) 5.3TB/5.7TB 10.7TB/ 11.5TB VIMM Count (Data + Hot Spare) 40+2 40+2 Reliability / Resiliency System Level Hardware Based vRAID VIMM level Hot-Swap Redundant power supply and fans Active/Active external memory gateways

  • HP VMA SAN, 18 HP VMA SAN Gateway Installation and Configuration Guide AM456-9025A Requirements Checklist Before you begin the installation process, it is important that you have the necessary materials on hand and have met the other requirements on the following checklist: Requirement Notes Laptop computer with terminal emulation software PuTTY or similar emulation application Appropriate serial cables for the Memory Array and San Gateway Network cable to attach between your laptop and a node, if necessary USB to serial converter to connect the serial cable to your laptop The appropriate SAN licenses, such as vSHARE For more informatio

  • HP VMA SAN, AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 49 Configuration Overview Configuring vSHARE is a prerequisite to using a HP VMA SAN Gateway for block storage. The vSHARE configuration allows you to define sophisticated rules for controlling access to the LUNs by initiator groups, initiators, or target ports. Configuring target ports and initiator groups are optional steps in the vSHARE configuration process. Organizations that do not want to use LUN-masking can control access to LUNs through ports or switches. LUN masking is an authorization process used to make a logical unit number available to some hosts an

  • HP VMA SAN, 22 HP VMA SAN Gateway Installation and Configuration Guide AM456-9025A Secondary Node Parameters A secondary node in a cluster automatically inherits all the global cluster parameters from the master node. Hence, there are fewer questions in the configuration wizard to answer for the standby node. The following table lists the configuration parameters for secondary nodes, along with a description for each. Cluster expected nodes Set the number of nodes (HP VMA SAN Gateways) in the cluster to "1". Change the value as in instructed in the

  • HP VMA SAN, AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 29 Configuring a Secondary HP VMA SAN Gateway Node Configuring a secondary SAN Gateway node is similar to configuring an additional node in a SAN Gateway cluster (a standby or normal node). Note: If you are configuring an additional node in a cluster, you should have successfully completed the procedure described in Configuring a HP VMA SAN Gateway Master/Standalone Node on page 23. • Standby node: The second node added to the

  • 60 HP VMA SAN Gateway Installation and Configuration Guide AM456-9025A lun export Command The lun export command enables you to export the LUNs within a specific container to an initiator or initiator group. A single LUN may be exported multiple times through different target ports (multipathing) or to different initiators (shared access). Syntax [no] lun export container <cont

  • 36 HP VMA SAN Gateway Installation and Configuration Guide AM456-9025A 2. Log in as admin. 3. Enter enable mode, and then configure terminal with the following commands. 4. Enable bonding using the following commands: 5. Repeat steps 1 through 4 on the secondary node. 6. Reboot both HP VMA SAN Gateway nodes to reconnect the cluster. VLAN Cluster Interface You can hide the cluster mu

  • HP VMA SAN, AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 81 Index A admin role 38 access privileges 38 password, setting 38 B battery, lithium 72 block size, of LUNs 55 block storage media devices initializing Memory Arrays 47–48 block storage, configuring 48 BSMI statement, Taiwan 74 C cabinet safety 72 caution icons 7 cluster configuration guidelines 36 configure Gateway 27 expected nodes 20 ID 20 interface name 19 name 20 network switches 35 node replacement 39 nodes, adding 27, 29 cluster management virtual IP address 20 virtual netmask 20 command modes roles, correspondence to 38 compliance information 69 s

  • HP VMA SAN, AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 59 Syntax Description show containers Command The show containers command displays all available containers. Syntax show containers Exporting LUNs The fifth step in configuring the vSHARE HP VMA SAN Gateway is to export the LUNs to an initiator. The LUN must be exported before it may be accessed over block protocols. Note: vSHARE LUNs are defined and saved within the Arrays themselves. vSHARE LUN export records are, however, managed and stored within the vCLUSTER configurat

  • HP VMA SAN, AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 77 Lithium Battery Caution WARNING! Observe the correct polarity when changing the lithium battery. There is a danger of explosion if battery is installed incorrectly. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions and local disposal requirements. Note: Switzerland: Annex 4.10 of SR 814.013 applies to batteries. Cabinet Safety Precautions

  • 38 HP VMA SAN Gateway Installation and Configuration Guide AM456-9025A Defining Additional Parameters Set the following parameters via the serial console port on the Master SAN Gateway, or via the management VIP address: • Global network parameters: Default Gateway or DNS Server information. • NTP Server IP address for time synchronization. • SMTP Server IP addr

  • HP VMA SAN, 50 HP VMA SAN Gateway Installation and Configuration Guide AM456-9025A Configuring Storage Containers The first step in configuring a vSHARE HP VMA SAN Gateway is to format the HP VMA-series Arrays and create the containers needed to manage LUNs in the target storage on each Memory Array. LUNs are addressable subsets of the container in a Memory Array. When a LUN is created, it is assigned to a specific container and inherits the attributes of that container. Note: As of this release, one container comprises a HP VMA-series Array. Initializing HP VMA-series Arrays To configure a HP VMA-series Array to support block storage, first initialize the HP

  • HP VMA SAN, 8 HP VMA SAN Gateway Installation and Configuration Guide AM456-9025A Document Conventions This documentation follows the conventions outlined in this section. Important Information The following table summarizes the notations used to call out important information, such as warning, caution, and note Typographical Conventions The following typographic conventions are used in this guide: Safety Icons Icon Sample Text WARNING! WA RN IN G! Only authorized, qualified, and trained personnel should attempt to work on this equipment. Caution: Caution: Follow the listed safety precaution

  • HP VMA SAN, AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 31 The following table lists the recommended software and settings for optimum performance of the VMA Gateway Web Interface. Accessing the VMA Gateway Web Interface You must use a supported browser with JavaScript and cookies enabled, as described in Supported Web Browsers on page 28. To access the VMA Gateway Web Interface, do the following: 1. Open a (supported) browser window. 2. Enter the following URL in the address field, substituting the variable in <brackets> with the actual value for your system. http://<Gateway_IP_address_or_hostname> The log in page appears. 3. Log

  • HP VMA SAN, AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 67 In the above example, support for Memory Array devices was added. When configuring this file, pay particular attention to the following: • path_grouping_policy should be set to group_by_serial • getuid_callout should be set • path_checker should be tur(TEST_UNIT_READY) • failback should be immediate • rr_weight should be uniform since weights are not assigned to the individual paths • no_path_retry should be set to immediately bring path back online • rr_min_io should be set to 4, but can be subject to change depending on the environment and workload. 2. Save the multipath.conf file and proceed with Con

  • HP VMA SAN, AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 41 CHAPTER 4 VMA Gateway Node Replacement This chapter demonstrates how to replace a HP VMA SAN Gateway node in a redundant pair, and covers the following topics: • Prerequisites on page 39 • Procedure Steps on page 40 • Completing the Replacement on page 41 Prerequisites A typical VMA gateway configuration consists of one or two HP VMA SAN Gateways, one of which is designated as the master node (mg-b) and one which is designated as the secondary node (mg-a).

  • HP VMA SAN, AM456-9025A HP VMA SAN Gateway Installation and Configuration Guide 57 1. From the CLI, enter into Enable mode using the enable command and then Configure mode using the configure terminal command. 2. All LUNs are created and managed within a container. To view the available containers, use the show containers command. Check the size of the containers. LUNs are implemented in 1 GB increments; the size of the container may restrict the number of LUNs that may be created. 3. Enter the lun create command to create LUNs within a cont

Related Products and Documents (Gateway):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Craftsman 183.172521 Owner's manual craftsman/183-172521-SE7.pdf 18 Nov 2023 52 2.7 Mb
2 Jenoptik 10.0z3 EasyShot Operation & user’s manual jenoptik/10-0z3-easyshot-WTH.pdf 20 Nov 2022 52
3 RIP TUNES MP1872 Instruction manual rip-tunes/mp1872-BGW.pdf 03 Jan 2024 21
4 Clarion APX320.2 Owners & installation manual clarion/apx320-2-55K.pdf 10 Jan 2024 19 0.5 Mb
5 RCA D770 - D 770 Universal Remote Control Code list rca/d770-d-770-universal-remote-control-914.pdf 02 Nov 2022 8 0.04 Mb
6 Nevion ADC-AES8 Operation & user’s manual nevion/adc-aes8-OP8.pdf 08 Mar 2023 13

Similar Resources:

  • ActionTec

    GT704WGRV

    (2 pages)
    1Connect the Gateway to a ComputerStep 3 Plug the smaller endof the Power Cord into theBlack Port on the back of theGateway.Step 4 Plug the larger end ofthe Power Cord into a PowerOutlet.Step 1 Get the Wireless DSLGatewayfrom your DSL Quick Start Kit.Step 2 Get the Power Cordfrom your DSL Quick Start Kit.Wireless DSL GatewayPower CordPower CordBlack PortStep …
  • Opengear

    ACM5504-5-GS-I

    (4 pages)
    ACM5504'5'GS'I+Q u ick +St art +(5 20 0 71'Rev+1.0)+ Page+1 !ACM5504(5(GS(I! Quick Start Guide Thank you for purchasing the ACM5504-5-GS-I management gateway. This Quick Start walks you through installation, configuration & local operation. More details are available in the User Manual, which can be downloaded from: http://op …
  • ICP DAS USA

    GW-7472

    (7 pages)
    GW-7472 The package includes the following items: I n s t a l l G W -7 4 7 2 U t i l i t y : The softwar e is located at: Fieldbus_CD:\EtherNetIP\Gateway\GW-7472\Utility http://ftp.icpdas.com/pub/cd/fieldbus_cd/ethernetip/gateway/gw-7472/utility/ Software CD Quick Start Guide (This Document) For …
  • Nortel

    1000

    (12 pages)
    Copyright © 2007 Nortel Networks. All rights reserved.Nortel Application Gateway Pre-Installation Checklist for Communication ServerThe Application Gateway 1000/2000 delivers business applications to Internet-enabled IP telephones and personal computers. It is an open, standards-based network platform that supports simultaneous voice and data services. IP p …
  • AudioCodes

    Media Pack Series

    (2 pages)
    Analog VoIP Gateways (MP-11X, MP-124D)MediaPackTM Series• Provides voice, fax and modem support• Offers toll quality voice compression• Enhanced capabilities including MWI, long haul, Metering Tones Generation, CID and outdoor protection**• Allows Fallback to PSTN for E911 (Emergency number PSTN breakthrough) or upon network/power failure (FXO an …
  • Berker

    75710016

    (4 pages)
    zKNX-DALI Gatewaytunable whiteyGateway KNX-DALIbianco modulabileDescription1 Keyboard for manual control2 Push Button and LED indicator for addressing3 KNX Connection4 Display of Dali numbers5 Connection to the network6 Dali connection.Control Control Elements 4 Display of the DALI numbers - 4a DALI Groups - 4b Individual participants- bc : If the display …

Comments, Questions and Opinions: