Panasonic CS-E9HKEA Manual Online:

4.05, 743 votes
Panasonic CS-E9HKEA User Manual
Panasonic CS-E9HKEA User Guide
Panasonic CS-E9HKEA Online Manual

Text of Panasonic CS-E9HKEA User Guide:

  • Panasonic CS-E9HKEA, 7 1. Cooling capacities are based on indoor temperature of 27qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air temperature of 35qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.) 2. Heating capacities are based on indoor temperature of 20qC D.B. (68qF D.B.) and outdoor air temperature of 7qC D.B. (44.6qF D.B.), 6qC W.B. (42.8qF W.B.) Note • Specifications are subject to change without notice for further improvement. Heat Exchanger Fin Material Aluminium (Pre Coat) Aluminium Fin Type Slit Fin Corrugated Fin Row x Stage x FPI 2 x 15 x 21 2 x 24 x 17 Size (W x H x L) mm 610 x 315 x 25.4 36.4 x 504 x 713 684 Air Filter Material P.P. Honey Comb — Type One-Touch �

  • Panasonic CS-E9HKEA, 3 1. The equipment must be earthed. It may cause electrical shock if grounding is not perfect. 2. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire. 3. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture. 4. Pb free solder has a higher melting point than standard solder; typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high temperature sol

  • Panasonic CS-E9HKEA, 51 16.2. Sensible Capacity Chart CS-E9HKEA CU-E9HKEA 230V Outdoor Temp. (qC) Indoor wet bulb temp. 30 35 40 46 TC SHC IP TC SHC IP TC SHC IP TC SHC IP 17.0qC 2.58 1.96 0.54 2.41 1.88 0.58 2.24 1.80 0.62 2.04 1.71 0.67 19.0qC 2.60 0.59 19.5qC 2.83 2.05 0.55 2.65 1.97 0.59 2.46 1.89 0.63 2.24 1.80 0.68 22.0qC 3.09 2.12 0.56 2.88 2.04 0.60 2.68 1.97 0.64 2.44 1.88 0.70 CS-E12HKEA CU-E12HKEA 230V Outdoor Temp. (qC) Indoor wet bulb temp. 30 35 40 46 TC SHC IP TC SHC IP TC SHC IP TC SHC IP 17.0qC 3.47

  • 5 1. Cooling capacities are based on indoor temperature of 27qC D.B. (80.6qF D.B.), 19.0qC W.B. (66.2qF W.B.) and outdoor air temperature of 35qC D.B. (95qF D.B.), 24qC W.B. (75.2qF W.B.) 2. Heating capacities are based on indoor temperature of 20qC D.B. (68qF D.B.) and outdoor air temperature of 7qC D.B. (44.6qF D.B.), 6qC W.B. (42.8qF W.B.) Note • Specifica

  • Panasonic CS-E9HKEA, 29 12.1.2.2. Horizontal Airflow 1. Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the angles as stated below. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1 below. 2. Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below and the positions of the vane are as Figure 2 above. 12.1.3. Quiet operation (Cooling Mode/Cooling area of

  • Panasonic CS-E9HKEA, 32 a. Ionizer Only Operation. 1. When air-conditioner unit is at “OFF” condition (standby) and ION operation button at remote control is pressed. Fan & ionizer on, ION LED illuminates, but power LED maintain off. (1 o 2) However, fan speed can be adjusted later by customer during this operation. Airflow direction (Horizontal Vane) control: Follow vane direction control at cooling mode. Horizontal vane can be changed by customer during ion only operation. b. Operation Mode + Ionizer Operation. 1. Ionising Operation Start Condition When air conditioner unit is in “ON” condition (Heat, Cool, Dry, Aut

  • Panasonic CS-E9HKEA, 52 17 Exploded View and Replacement Parts List 17.1. Indoor Unit Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.

  • Panasonic CS-E9HKEA, 25 11.4. Outdoor Unit 11.4.1. INSTALL THE OUTDOOR UNIT • After selecting the best location, start installation according to Indoor/Outdoor Unit Installation Diagram. 1. Fix the unit on concrete or rigid frame firmly and horizontally by bolt nut (ø10 mm). 2. When installing at roof, please consider strong wind and earthquake. Please fasten the installation stand firmly with bolt or nails. 11.4.2. CONNECTING THE PIPING Connecting The Piping To Indoor Unit Please make flare after inserting flare nut (locate a

  • Panasonic CS-E9HKEA, 21 11 Installation Instruction 11.1. Select The Best Location INDOOR UNIT • Do not install the unit in excessive oil fume area such as kitchen, workshop and etc. • There should not be any heat source or steam near the unit. • There should not be any obstacles blocking the air circulation. • A place where air circulation in the room is good. • A place where drainage can be easily done. • A place where noise prevention is taken into consideration. • Do not install the unit near the door way. • Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles. • Recommended installation

  • 31 (c) Heating Operation 12.1.5. ON Timer Control ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is to provide a comfortable environment when reaching the set ON time. 60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to determine the in

  • Panasonic CS-E9HKEA, 6 2.2. CS-E12HKEA CU-E12HKEA ITEM UNIT INDOOR UNIT OUTDOOR UNIT Performance Test Condition EUROVENT C O O L I N G Capacity kW 3.50 (0.60 ~ 4.00) kCal/h 3010 (520 ~ 3440) EER W/W 3.80 (5.00 ~ 3.39) kCal/hW 3.27 (4.33 ~ 2.92) Noise Level dB (A) High 42, Low 29, Q-Lo 26 High 48 Power level dB 53 61 H E A T I N G Capacity kW 4.80 (0.60 ~ 6.60) kCal/h 4130 (520 ~ 5680) COP W/W 3.81 (5.22 ~ 3.57) kCal/hW 3.28 (4.52 ~ 3.07) Noise Level dB (A) High 42, Low 33, Q-Lo 30 High 50 Power level dB 53 63 Moisture Removal l/h 2.0 pt/h 4.2 Air Volume Lo m 3 /min (ft 3 /min) Cooling; 5.8 (204) — Heating; 7.4 (261) Me m 3 /min (ft 3 /min) Cooling; 8.1 (286)

  • Panasonic CS-E9HKEA, 35 14 Troubleshooting Guide 14.1. Refrigeration Cycle System In order to diagnose malfunctions, make sure that there are no electrical problems before inspecting the refrigeration cycle. Such problems include insufficient insulation, problem with the power source, malfunction of a compressor and a fan. The normal outlet air temperature and pressure of the refrigeration cycle depends on various conditions, the standard values for them are shown in the table to the right.

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sony DAV-X1 Quick start manual sony/dav-x1-QPL.pdf 18 Mar 2023 2 0.38 Mb
2 Samsung HT-D6500 Declaration of conformity samsung/ht-d6500-DA6.pdf 17 Oct 2022 1 0.07 Mb
3 VTech GZ2434 - VMix Cordless Phone Operating instructions manual vtech/gz2434-vmix-cordless-phone-238.pdf 05 Nov 2023 28 1.11 Mb
4 Waterpik Water Flosser plus WP-900 Instruction manual waterpik/water-flosser-plus-wp-900-T4U.pdf 25 Sep 2023 12
5 Haier HM-09CA03 Operation manual haier/hm-09ca03-6ED.pdf 29 Jun 2023 15
6 Laney Nexus FET NXF Operating instructions manual laney/nexus-fet-nxf-JEU.pdf 14 Oct 2023 20

Similar Resources:

  • SPT

    WA-60FMS1

    (18 pages)
    WINDOW AIR CONDITIONERBefore using your air conditioner, please readthis manual carefully and keep it for future reference.WINDOW/WALLTYPEBefore using your air conditioner, please readthis manual carefully and keep it for future reference.WINDOW/WALLTYPEBefore using your air conditioner, please readthis manual carefully and keep it for future reference.WINDO …
  • Rotex

    Bi-Bloc Ultra RHBX08DA9W

    (20 pages)
    User reference guideROTEX HPSU low temperature Bi‑blocEnglishUser reference guideROTEX HPSU low temperature Bi‑blocRHBX04DA6VRHBX04DA9WRHBX08DA6VRHBX08DA9WFinal English - Tanslations in progress …
  • Friedrich

    MR24C3F

    (24 pages)
    SPLIT TYPEROOM AIR CONDITIONERWALL MOUNTEDtypeCONTENTSSPECIFICATIONS ................... 1DIMENSIONS ....................... 2REFRIGERANT SYSTEM DIAGRAM .... 3CIRCUIT DIAGRAM ................. 4ERROR CONTENTS ................5INDOOR PCB CIRCUIT DIAGRAM .....8OUTDOOR PCB CIRCUIT DIAGRAM . . .13DISASSEMBLY ILLUSTRATION ....... 14PARTS LIST .................... …
  • LU-VE

    SHVN Series

    (8 pages)
    ISTRUZIONE PER IL MONTAGGIO E LA MANUTENZIONE PER INSTALLATION AND MAINTENANCE INSTRUCTION FOR INSTRUCTION POUR LE MONTAGE ET L’ENTRETIEN POUR MONTAGE UND WARTUNGSANLEITUNG FÜR 1ITALIANODICHIARAZIONE DEL FABBRICANTE. Riferimento EC Direttiva Macchine 89/392 CEE e successivi emendamenti.Gli apparecchi sono stati progettati e costruiti per poter essere inco …
  • Haier

    HSU24VHJ

    (28 pages)
    84 Domestic air conditioner4 Pull the front grille outhorizontally and removeit.When assembling, install thefront grille horizontally so asnot to stuff the flap inside.When assembling, makesure the three hooks arecaught properly.StepProcedure PointsHSU24VHJ(DB) RemovalProcedure …
  • GE

    ASM18DK

    (2 pages)
    Note: When installing slide-out chassis units in through-the-wall applications, keep louvers free. Do not restrict air flow areas. Fixed chassis units are not suitable for through-the-wall applications.Wall Outlets: All wiring including installation of receptacle must be made in accordance with local electrical codes and regulations. Electrical outlet shoul …

Air Conditioner Instructions:

Comments, Questions and Opinions: