Manualios.com

Panasonic CU-8ME1XPK Installation Manual

Panasonic CU-8ME1XPK Manual Online:

4.4, 638 votes
Panasonic CU-8ME1XPK User Manual
Panasonic CU-8ME1XPK User Guide
Panasonic CU-8ME1XPK Online Manual

Text of Panasonic CU-8ME1XPK User Guide:

  • Panasonic CU-8ME1XPK, ENGLISH DEUTSCH FRANÇAIS ESPAÑOL ITALIANO E§§HNIKA NEDERLANDS PORTUGUES INSTALLATION MANUAL Model No. (Urban Multi Heat recovery inverter series) CU-8ME1XPK CU-10ME1XPK PACKAGED AIR CONDITIONER R407C REFRIGERANT COVER 01.10.2, 1:55 PMPage 1 Adobe PageMaker 6.5J/PPC

  • Panasonic CU-8ME1XPK, 1 CONTENTS Introduction .................................................................................... 1 Combination .................................................................................... 1 Standard supplied accessories ...................................................... 2 Optional accessories ...................................................................... 2 Technical specifications .................................................................. 2 Electrical specifications .............

  • Panasonic CU-8ME1XPK, 2 ENGLISH Standard supplied accessories (see figure10) CU-∗∗ME1XPK 8/10 tie-wrap (1) gas side attached pipe (2) gas side attached pipe (2) liquid side attached pipe (2) discharge gas side attached pipe (2) installation manual (1) operation manual (1) 2 1 1 1 1 1 1 Optional accessories The outdoor unit requires purchasing the following refrigerant branch kits separately. Make sure to use exclusive parts for R407C. for 2 pipes for 3 pipes Herder branch pipes CZ-P18HK11P CZ-P18HK31P CZ-P37HK31P Line branch pipes CZ-P18BK11P CZ-P18BK31P CZ-P20BK31P Note - Refer to the chapter “Examp

  • 3 MAIN COMPONENTS For main components and function of the main components, refer to the Engineering Data Book. SELECTION OF LOCATION This unit, both indoor and outdoor, is suitable for installation in a commercial and light industrial environment. If installed as a household appliance it could cause electromagnetic interference. The inverter units should be installed in a location that meets

  • 4 ENGLISH Connecting the refrigerant piping 1. Installation of refrigerant piping is possible as front connection, side connection and bottom connection. 2. Make sure to perform the piping installation within the range of the maximum allowable pipe length, allowable level difference and allowable length after branching as indicated in chapter “Example of connection”

  • Panasonic CU-8ME1XPK, 5 z a ~ t 1234567 8 HR1 HR2 H2 H1 HR3 HR4 a bcde f g hk i n q st mpr AB CDE FG 123456 7 8 H2 H1 HR5 HR1 HR2 HR3 HR4 a hj ln gik m p q f ce d b A B 12 3 4 5 6 7 8 H2 H1 HR1 HR2 HR3 HR4 HR5 HR6 a fdbhjln gecikm p HR BOX Discharge gas line Suction gas line Liquid line Gas line Liquid line Example of connection Connection of 8 indoor units indoor unit line branch pipes header branch pipes three lines two lines connecting-line length Branch with line branch pipes Branch with line branch pipes and header branch pipes Branch with header branch pipes Branch with line branch pipes Branch with line branch pipes and

  • Panasonic CU-8ME1XPK, 6 ENGLISH - This outdoor unit is factory charged with refrigerant and depending on pipe sizes and pipe lengths some systems require additional charging of refrigerant. - Charge the refrigerant to the liquid pipe in its liquid state. Since R407-C is a mixed refrigerant, its composition changes if charged in a state of gas and normal system operation would no longer be assured. - Determine the weight of refrigerant to be charged additionally referring to the item “Additional refrigerant to be charged” in chapter “Example of connection”. And

  • Panasonic CU-8ME1XPK, 7 Internal wiring - parts table Refer to the wiring diagram sticker on the unit. The abbreviations used are listed below: A1P ................... Printed circuit board A2P ................... Printed circuit board (INV) A3P ................... Printed circuit board A4P ................... Printed circuit board BS1-5 ................ Push button switch (mode, set, return, wiring check, reset) C1R-4R ............. Capacitor F1S ................... Surge arrester F2C ................... Over current relay (M2C) F1U, 2U ..

  • Panasonic CU-8ME1XPK, 8 ENGLISH Sequential start Make the outdoor unit cable connections shown below. The outdoor unit PC board (A1P) is factory set at “Sequential start available”. Examples System example (refer to figure 5) 1 field power supply 2 main switch 3 earth leak detector 4 fuse 5 HR box 6 indoor unit 7 remote controller 8 selection of cooling and heating 9 cooling only power supply wiring (sheathed cable) transmission wiring (sheathed cable) Note - Select the particular size of electrical wire for power supply wiring

  • Panasonic CU-8ME1XPK, 9 BEFORE OPERATION Checks before initial start-up - To switch on the crankcase heater, turn on the circuit breaker. - Set the LED on the outdoor unit PC board after turning on the circuit breaker. - Before switching on the indoor unit(s), refer to the operation manual of the corresponding unit(s) for more details. - Turn on the switch to indoor unit(s) and HR box(es). - The test run must be performed starting with cooling operation. Start this operation about 8 minutes after turning on the indoor unit and outdoor unit power. Note - Do not try to get started with the remot

  • Panasonic CU-8ME1XPK, 10 ENGLISH How to operate stop valves (refer to figure 11) 1. To open 1. Remove the cap (1) and turn the shaft (2) counterclockwise with hexagon socket screw keys (JIS B 4648 nominal size 6 mm and 10 mm). 2. Turn it all the way until the shaft stops. 3. Tighten the cap firmly. 2. To close 1. Remove the cap and turn the shaft clockwise. 2. Tighten the shaft firmly until it reaches the sealed area (4) of the body. 3. Tighten the cap firmly. Note - Refer to the table at the end of this chapter for tightening torques and dimensions of the flares. - Be sure to use both, a spanner and a torque wrench, when connecting or disconnecting pipes to or from the unit. - When conn

  • 11 1 2 NOTES total volume of refrigerant in the refrigerant system size (m 3 ) of smallest room in which there is an indoor unit installed B. Where there is a room division but there is an opening between the rooms sufficiently large to permit a free flow of air back and forth. 1 opening between rooms 2 partition (Where there is an opening without a door or where there

More Instructions:

DOWNLOAD

Related Products and Documents (Heater):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 LG WD-1050FH Service manual lg/wd-1050fh-1Y2.pdf 08 Mar 2023 34
2 Randell 2235 Specifications randell/2235-YTW.pdf 15 Jul 2022 2 0.11 Mb
3 Korg EMX-1 Owner's manual korg/emx-1-3LG.pdf 08 Dec 2022 99
4 CYBEX 600T Owner's manual cybex/600t-SIV.pdf 19 Nov 2023 41 1.12 Mb
5 MTD OEM-190-604 Operator's manual mtd/oem-190-604-7EM.pdf 10 May 2023 4
6 Radio Shack Cordless Room Monitor Owner's manual radio-shack/cordless-room-monitor-27T.pdf 21 Jan 2024 16 0.43 Mb

Similar Resources:

  • Glen

    GL 7017

    (2 pages)
    U S E R ' S G U I D EThis GLEN Quartz Heater is fully warranted against any defect arising out of defective materials or faulty workmanship for a period of one years from the date of purchase. Should any defect develop in this product, the customer should bring the product to the nearest authorised service centre, where the company undertakes to get t …
  • Dimplex

    LPP050

    (9 pages)
    ContactDetailsPleasenotethatsomeofthecontactdetailsonthisPDFdocumentmaynotbecurrent.Pleaseusethefollowingdetailsifyouneedtocontactus:Telephone:08448793588Email:[email protected]Thecustomersupportsectio …
  • Baxi

    CL 50 CR

    (4 pages)
    CL 50 CR, HO 45, CL 60 & CL 60 CRCL 50 CR, CL 60& CL 60 CRHO 45Radiadores de Casa de BanhoInstruções de Montagem para o INSTALADORBathroom RadiatorsInstallation Instructions for the INSTALLERRadiadores para Cuarto de BañoInstrucciones de Instalación para el INSTALADORESGBPT …
  • Detroit Radiant Products

    MW-24

    (20 pages)
    WARNING!!Detroit Radiant Products CompanyAll persons involved with the installation, operation and maintenance of the heater system must read and understand the information in this manual.Overhead Medium Wave Electric Infrared Heater Installation, Operation, Maintenance and Parts1, 2 and 3 Lamp UnitsMW Series ManualImproper installation, adjustment, alterat …
  • Accorroni

    GTF Series

    (20 pages)
    0051Storage gas water heaters with forcedand sealed conbustion chamber, assisted gas fanINSTALLATION, USE AND MAINTENANCE MANUAL GTF SERIESMOD. 22030 kWMOD. 30034kWMOD. 40034kWMOD. 50034kWMOD. 80034kWAPRIL 2009 Issue (Italy)GTF SOL SERIESFOR USE WITH ASECOND ENERGY SOURCEMOD. 220MOD. 300MOD. 400MOD. 500MOD. 800 …
  • Honeywell

    HZ-515 Series

    (3 pages)
    IMPORTANTSAFEGUARDSREAD AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:IMPORTANT INSTRUCTIONS1. Read all instructions before using this heater.2. This heater is hot when in use. …

Comments, Questions and Opinions: