Manualios.com

Altigen Advanced Call Router Manual 

Altigen Advanced Call Router Manual Online:

4.7, 2362 votes
Altigen Advanced Call Router User Manual
Altigen Advanced Call Router User Guide
Altigen Advanced Call Router Online Manual

Text of Altigen Advanced Call Router User Guide:

  • Altigen Advanced Call Router, Advanced Call Router Manual i Contents New in Previous Release, 5.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 To Configure/Run Advanced Call Router . . . . . . . . . . . . . . . . . . . . 2 Advanced Call Router Route Rules . . . . . . . . . . . . . . . . . . . . . . . . . 3 Creating Route Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Viewing Advanced Call R

  • Altigen Advanced Call Router, Advanced Call Router Advanced Call Router Manual 11 Enter the workgroup extension as the WorkGroup ID and password, and enter the virtual extension’s password. In the field for Default Wait Time in Queue, type in the desired minutes. (By default, the Extension ID field is grayed out.) • Delete button—click Delete to remove the selected workgroup from the display. • Change Default Wait Time—click this button to change the default anticipated wait time associated with the workgroup queue. Note: The workgroup to which incoming trunk calls will be routed via Call Router must be assigned to the Auto Attendant whose Action i

  • Altigen Advanced Call Router, Advanced Call Router Route Rules 8 Advanced Call Router Manual Note: Play WG Queue Status - if you select “Play WG Queue Status,” Advanced Call Router must log on as a workgroup extension with password (View > Show Workgroup Status > Add) and Call Router’s virtual extension and password. (The virtual extension that Call Router uses does not have to be a member of the workgroup.) Specify this workgroup extension in the textbox that appears when you select Play WG Queue Status. (See “Queue Announcements” on

  • Altigen Advanced Call Router, Testing Call Router 22 Advanced Call Router Manual Testing SQL Server Database To test SQL server database access performance of Call Router: 1. Add a database for the SQL server. For example, for a database “calldb” and table name “RTMCALL”, 10,000 records are added to the table. Note: Because the data of DDR request has been hard coded, if you want a rule match, you need to add the record to the table. The caller ID of test request will be “1039470405.” IVR Path of test request will be “0&9.” To use the “SessionId” field in the table to match caller ID of the request, you must add a record to the table and set the SessionId value to “1039470405�

  • Advanced Call Router Route Rules 4 Advanced Call Router Manual • Add - opens a Custom Record dialog box, where you can create a new record and build the conditions for the record. • Modify - opens the Customer Record dialog box to modify the record selected in the Record List. • Delete - deletes the record selected in the Record List. • Delete All - deletes all records in the Record

  • Altigen Advanced Call Router, Advanced Call Router Advanced Call Router Manual 19 The Monitor window shows that Call Router is logged on to both workgroups. Calls to each workgroup will be checked against the rules and will trigger a queue announcement if a match is found and all agents are busy. Testing Call Router To test the performance of Call Router, you can access a test tool from the Call Router main menu. Call Router must be stopped in order to run the test.

  • Altigen Advanced Call Router, Advanced Call Router Advanced Call Router Manual 17 In the Monitor window, click Add to log on to Sales, entering both the workgroup extension & password and the virtual extension & password you specified in the “Auto Attendant Sales Queue Announcement” rule:

  • Altigen Advanced Call Router, Additional Advanced Call Router Features 18 Advanced Call Router Manual In the Monitor window, click Add to log on to Support, entering both the workgroup extension & password and the virtual extension & password you specified in the “Auto Attendant Sales Queue Announcement” rule:

  • Altigen Advanced Call Router, Advanced Call Router Advanced Call Router Manual 5 Default Routing Action options: No Action, Goto Top Level, Repeat Current Level, Call to Extension/Workgroup, Call to Operator, Dial by Name, Collect Extension, Directory Service, Record Message (specify target data in accompanying text box), Mailbox Access, Disconnect, System Callback, Collect Digits (specify fields in accompanying Collect Digit dialog box), Other DDR Application (specify target data in accompanying text box), Play WG Queue Status (specify target

  • Altigen Advanced Call Router, WARNING! Toll fraud is committed when individuals unlawfully gain access to customer telecommunication systems. This is a criminal offense. Currently, we do not know of any telecommunications system that is immune to this type of criminal activity. AltiGen Communications, Inc., will not accept liability for any damages, including long distance charges, which result from unauthorized and/or unlawful use. Although AltiGen Communications, Inc., has designed security features into its products, it is your sole responsibility to use

  • Altigen Advanced Call Router, Advanced Call Router Route Rules 6 Advanced Call Router Manual 3. In the Rule Name field, enter or modify the rule name. 4. Select the data to match against routing rules. • If Caller Info contains—lets you select Call Route Request data to match against the customer record. a) Select “Match one” or “Match all” from the drop-down list. b) Select the items you want. c) Click in the Data column and type to specify the data. To manually specify data for an item, right-click the item, select Input data and enter information in the column. • Caller Entered Digits must be numeric only. • You can enter “*” as a wildcard character for any length of digits, or “?�

  • Altigen Advanced Call Router, To Configure/Run Advanced Call Router 2 Advanced Call Router Manual To Configure/Run Advanced Call Router 1. Launch Call Router from the Windows Start menu. 2. Click the Connect button to enter the Call Router Server Name or IP address to connect to, then click OK. To disconnect from this server, click the Disconnect button. 3. Select Operation > Logon Info.

  • Altigen Advanced Call Router, Additional Advanced Call Router Features 14 Advanced Call Router Manual requirement to use the same virtual agent extension if you are writing several different queue announcement rules. 2. In AltiWare Administrator, you must configure one of the Auto Attendant numbers to which Call Router is assigned to “Advanced Call Router.” 1) Enter the same “Item Name” you use in the rule discussed immediately above. 2) Replace the “No Action” level with “Call – to Ext./Workgroup,” and enter the workgroup extension number. For further information on configuring Auto Attendants, see the AltiWare Administration Manual and the AltiAPI Programmer Guide. If your organization has mul

  • Altigen Advanced Call Router, Advanced Call Router Advanced Call Router Manual 3 4. In the Logon Info window, enter the Server Name that Advanced Call Router will connect to, along with the Default Virtual Extension and Password then click OK. (Optional) Check Auto Start Service to have Advanced Call Router start routing calls automatically, after the system restarts or after Advanced Call Router service has been stopped and restarted. Note: Up to 8 login attempts are allowed, after which login will be disabled from 1 to 24 hours (dependin

  • Advanced Call Router Advanced Call Router Manual 9 Call Route Request Data The “Call Router Request” message sent by AltiServ to Call Router contains data about the incoming call, which Call Router attempts to match against your routing rules. Call Route Request data consists of Caller ID, IVR Path, IVR data and DNIS, all collected via real-time monitoring. Note: IVR Path

  • Advanced Call Router Route Rules 10 Advanced Call Router Manual Note: If no match is found between the Call Route Request Data and the routing rules, the call is routed according to the business rules that check monitored workgroups for the longest available agent, maximum service level, and minimum expected delay. Show Workgroup Status To view real-time data

  • Altigen Advanced Call Router, Clearing Advanced Call Router History Data 12 Advanced Call Router Manual Clearing Advanced Call Router History Data To clear data from the Advanced Call Router History window 1. Go to the directory “Program Files\AltiGen\Call Router” and locate the Call Router.csv file. 2. Open Call Router.csv and delete all contents. 3. Save and close Call Router.csv. Additional Advanced Call Router Features Building SQL Queries To build an SQL query that Call Router will send to your database, use the CallerId Dat

  • Altigen Advanced Call Router, Testing Call Router 24 Advanced Call Router Manual You can change the rule configuration to fit your own conditions. During the test, Call Router will use this rule to match the DDR request. When using this rule, Call Router will access the SQL server to execute the SQL query.

  • Altigen Advanced Call Router, Advanced Call Router Advanced Call Router Manual 1 Advanced Call Router Advanced Call Router is the standard AltiGen Call Router application plus call router service. Advanced Call Router requires the purchase and activation of an Advanced Call Router license. Note: The workgroup to which incoming trunk calls will be routed via Call Router must be assigned to the auto attendant whose Action is set to “Adv - Advanced Call Router,” with Ext Num set to the virtual extension you use to configure Call Router. For information on configuring auto attendants, refer to the Auto Attendant Configuration chapter of the Alti

  • Altigen Advanced Call Router, Testing Call Router 20 Advanced Call Router Manual To test Call Router: 1. With Call Router function stopped, go to Test in the Tool drop-down list of the Call Router main menu for the Test dialog box. 2. In the Configuration fields, you can input the following test parameters: • Number of concurrent calls • Interval between calls • Number of test cycles For example, inputting 5 for concurrent calls, 3 for interval between calls, and 4 for test cycles means that every 3 seconds, there will be 5 concurrent call requests to Call Router. Total cycles of concurrent requests will be 4 tim

  • Altigen Advanced Call Router, Advanced Call Router Advanced Call Router Manual 23 The “TestSQL” is the newly added data source. This data source is connected to the SQL server’s “calldb” database. 3. In Call Router, add a rule to access database.

  • Altigen Advanced Call Router, Advanced Call Router Advanced Call Router Manual 7 For example, if you specify Call ID Data “510252*,” this will match all Caller IDs 510-252-xxxx. If you specify Call ID Data “510252????,” this will match all Caller IDs 510 252-xxxx. • To specify data from an existing database, right-click the item, select From user database, and enter information in the DataSource dialog box. 5. Select a Target action for Call Router to perform when Call Route Request data matches this record. Target action options: No Action, Goto Top Level, Repeat Current Level, Call to Extension/Workgroup, Call to Operator, Dial by Name, Collect Extension, Directory Service, Record Message (specify

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Rolando Texart XT-640 Operation & user’s manual rolando/texart-xt-640-1K3.pdf 18 Jul 2022 156
2 Bronpi Dama Hydro Installation, operating and service instructions bronpi/dama-hydro-8C2.pdf 06 Jan 2023 120
3 Cateye Vectra CC-VT100W Owner's manual cateye/vectra-cc-vt100w-H6L.pdf 18 Mar 2023 3 0.41 Mb
4 GE ASQ10AL Dimensions and installation information ge/asq10al-WFS.pdf 05 Aug 2023 2 0.16 Mb
5 Vitek VTD-A4F/IWM Operation & user’s manual vitek/vtd-a4fiwm-QI8.pdf 13 Feb 2023 28
6 Pioneer DEH-P5800MP Operation manual pioneer/deh-p5800mp-638.pdf 17 Jun 2023 110

Similar Resources:

  • TRENDnet

    TEW-P21G

    (30 pages)
    - 2 - TABLE OF CONTENTS ABOUT THIS GUIDE..................................................................................4 1. INTRODUCTION.....................................................................................5 PACKAGE CONTENTS ....................................................................................6 SYSTEM REQUIREMENTS....... …
  • EnGenius

    EPG600

    (11 pages)
    EPG600version l.0IoT GatewayQuick Start GuideEnglish Español Português brasileiroDeutsch Français Polski 簡体中文 Türkçe русский …
  • Cisco

    1760V

    (85 pages)
    CISCO ACCESS AND INTEGRATED SERVICES ROUTERSCisco SOHO, 800, 1700, 1800, 2600, 2800, 3700, 3800, 7200, and 7300 SeriesCISCO ROUTER GUIDEFOR TELEWORKERS, SMALL OFFICES, SMALL TO MEDIUM-SIZED BUSINESSES, AND ENTERPRISE BRANCH AND HEAD OFFICESFALL 2004 / WINTER 2005 V.1 …
  • Cal Amp

    VIPER SC+ 100 series

    (206 pages)
    VIPER SC+™ INTELLIGENT IP ROUTERS FOR LICENSED SPECTRUM User Manual Viper SC+™ Intelligent IP Routers for Licensed Spectrum PN 001-5008-000 Rev. C Revised February 2016 …
  • EFOY

    Pro Series

    (4 pages)
    Firmware Guide – EFOY Pro Series SFC Energy AG Tel.: +49 89 673 592 – 0 Fax: +49 89 673 592 – 369 Email: [email protected] Subject to modifications and errors Web: www.efoy-pro.com 1 / 4 Valid from: 23th March 2018 How to find out, which firmware …
  • GSD

    Wi-Plus Controller

    (12 pages)
    Installation & User Manual V2.04No.1 Turnpike Business Park,Ballymount,Dublin 22, Ireland.Telephone: +353 1 524 2691.Fax: +353 1 4430 430.3Contents6Installation Diagrams98System Overview Wi-Plus ControllerOther products from GSD“Wireless NetworkSystem”GSD Wi-Max System is the next generationin access control solutions. It provides aWireless Network t …

Network Router Instructions:

Comments, Questions and Opinions: