  • Siemens RUGGEDCOM RMC, Chapter 6 Certification RUGGEDCOM RMC Installation Guide 22 EMI and Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-2 Dry Heat Test Bd 85 °C (185 °F), 16 Hours IEC 60068-2-30 Humidity (Damp Heat, Cyclic) Test Db 95% (non-condensing), 55 °C (131 °F), 6 cycles IEC 60255-21-1 Vibration 2 g @ 10-150 Hz Class 2 IEC 60255-21-2 Shock 30 g @ 11 ms Class 2

  • Siemens RUGGEDCOM RMC, Chapter 1 Introduction RUGGEDCOM RMC Installation Guide 2 Ports, Controls and Indicator LEDs Universal Power Supply Options • 24VDC, 48VDC or HI (88-300VDC / 85 - 264VAC) options for worldwide operability • Integrated high-reliability power supply eliminates the need for external power transformer • Screw down terminal blocks ensure reliable maintenance-free connections • All power supplies CSA/UL 60950 approved for 85 °C (185 °F) operation Section 1.2 Ports, Controls and Indicator LEDs The RMC features various ports, controls and indicator LEDs on the front panel for configurin

  • Siemens RUGGEDCOM RMC, RUGGEDCOM RMC Installation Guide Preface Alerts v Preface This guide describes the RUGGEDCOM RMC. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device. It is also recommended for use by network and system planners, system programmers, and line technicians. Alerts The following types of alerts are used when necessary to highlight important informati

  • Siemens RUGGEDCOM RMC, Chapter 3 Communication Ports RUGGEDCOM RMC Installation Guide 12 Fiber Optic Ethernet Ports Mode Selector Positioning Configuration SW1 SW2 Description FDX Mode ON OFF Full-Duplex fiber partner (default) Reserved ON ON a Should ONLY be used on 10FL series RMC products. The transparent mode can be utilized when BOTH the copper side and fiber side devices are capable of auto- negotiating duplex mode and speed as per TIA/EIA-785. When both partners are capable of negotiation, the RMC can support 100Base-TX to 100Base-SX, full duplex, copper-to-fiber

  • RUGGEDCOM RMC Installation Guide Table of Contents iii Table of Contents Preface ................................................................................................................ v Alerts .................................................................................................................................................. v Accessing Documen

  • Siemens RUGGEDCOM RMC, RUGGEDCOM RMC Installation Guide Chapter 1 Introduction Feature Highlights 1 Introduction The RUGGEDCOM RMC is an industrially hardened fiber optical media converter specifically designed to operate in harsh environments such as those found in electric utility substations and factory floors. The RMC provides industrial strength Ethernet copper-to-fiber media conversion allowing for 10Base-T to 10Base-FL and 100Base-TX to 100Base-FX over SingleMode or MultiMode fiber optics. The RMC is specifically designed to meet the same EMI immunity and environmental requirements as mission critical protective relaying devices in

  • Siemens RUGGEDCOM RMC, RUGGEDCOM RMC Installation Guide Chapter 4 Technical Specifications Power Supply Specifications 13 Technical Specifications The following sections provide important technical specifications related to the device and available modules: • Section 4.1, “Power Supply Specifications” • Section 4.2, “Copper Ethernet Port Specifications” • Section 4.3, “Fiber Optic Ethernet Port Specifications” • Section 4.4, “Supported Networking Standards” • Section 4.5, “Operating Environment” • Section 4.6, “Mechanical Specifications” Section 4.1 Power Supply Specifications Power Supply Type

  • Siemens RUGGEDCOM RMC, Preface RUGGEDCOM RMC Installation Guide vi Training Training Siemens offers a wide range of educational services ranging from in-house training of standard courses on networking, Ethernet switches and routers, to on-site customized courses tailored to the customer's needs, experience and application. Siemens' Educational Services team thrives on providing our customers with the essential practical skills to make sure users have the right knowledge and expertise to understand the various technologies associated with critical communications network infrastr

  • Siemens RUGGEDCOM RMC, RUGGEDCOM RMC Installation Guide Chapter 3 Communication Ports Fiber Optic Ethernet Ports 11 When connecting to end devices, the X-over switch should be selected to reflect the type of cabling used. Specifically, straight through should be selected when using straight through cabling, an crossover (X-over) should be selected when using crossover cabling. The presence of an active LINK LED indicates the X-over selection switch is in the proper position. IMPORTANT! For substation applications, it is not recommended to use these ports to interface with field devices across distances that could produce high levels of ground pot

  • Siemens RUGGEDCOM RMC, Chapter 2 Installing the Device RUGGEDCOM RMC Installation Guide 4 Mounting the Device on a DIN Rail Section 2.1.1 Mounting the Device on a DIN Rail For DIN rail installations, the RMC can be equipped with a DIN rail bracket pre-installed on the back of the chassis. The bracket allows the device to be slid onto a standard 35 mm (1.4 in) DIN rail. To mount the device to a DIN rail, do the following: 1. Align the slot in the bracket with the DIN rail. 1 1 2 3 Figure 2: DIN Rail Mounting 1. DIN Rail 2. DIN Rail Bracket 3. Screw Driver 2. Pull the release on the bracket down and slide the device onto the DI

  • Siemens RUGGEDCOM RMC, RUGGEDCOM RMC Installation Guide Chapter 4 Technical Specifications Operating Environment 15 Section 4.5 Operating Environment Parameter Range Comments Ambient Operating Temperature -40 to 85 °C (-40 to 185 °F) Measured from a 30 cm (12 in) radius surrounding the center of the enclosure. Ambient Relative Humidity 5% to 95% Non-condensing Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F) Section 4.6 Mechanical Specifications Parameter Value Dimensions Refer to Chapter 5, Dimension Drawings Weight 0.68 kg (1.5 lbs) Ingress Protection IP40 (1 mm or 0.04 in

  • Siemens RUGGEDCOM RMC, Chapter 3 Communication Ports RUGGEDCOM RMC Installation Guide 10 Copper Ethernet Ports WARNING! Electric shock hazard – risk of serious personal injury and/or equipment interference. If shielded cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more importantly, create a potential shock hazard that can result in serious injury. Each port features a Speed and Link LED that indicates the state of the port. LED State Description Yellow The port is operating at 100 MbpsSpeed Off The por

  • RUGGEDCOM RMC Installation Guide Chapter 2 Installing the Device Mounting the Device 3 Installing the Device The following sections describe how to install the device, including mounting the device, installing/removing modules, connecting power, and connecting the device to the network. DANGER! Electrocution hazard – risk of serious personal injury and/or damage to equipment. Before performing a

  • Siemens RUGGEDCOM RMC, Table of Contents RUGGEDCOM RMC Installation Guide iv Chapter 5 Dimension Drawings .......................................................................................... 17 Chapter 6 Certification ........................................................................................................ 19 6.1 Agency Approvals ...................................................................................................................... 19 6.2 FCC Compliance ........................................................................................................................

  • Siemens RUGGEDCOM RMC, RUGGEDCOM RMC Installation Guide Chapter 6 Certification EMI and Environmental Type Tests 21 Test Description Test Levels Severity Levels IEC 61000-4-17 Ripple on DC Power Supply DC Power ports 10% 3 Signal ports 2 kVAC (Fail-Safe Relay output) DC Power ports 1.5 kVDC Dielectric Strength AC Power ports 2 kVDC Signal ports 5 kV (Fail-Safe Relay Output) DC Power ports 5 kV IEC 60255-5 HV Impulse AC Power ports 5 kV a Siemens specified severity level. IEEE 1613 (C37.90.x) EMI Immunity Type Tests NOTE The RMC meets Class 2 requirements for an all-fiber con

  • Siemens RUGGEDCOM RMC, RUGGEDCOM RMC Installation Guide Chapter 2 Installing the Device Connecting DC Power 7 3. Using a braided wire or other appropriate grounding wire, connect the surge ground terminal to the chassis ground connection. The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit. 4. Connect the ground terminal on the power source to the chassis ground terminal on the device. Section 2.2.2 Connecting DC Power To connect a high or low DC power supply to the device, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Before te

  • Siemens RUGGEDCOM RMC, RUGGEDCOM RMC Installation Guide ii Copyright © 2014 Siemens Canada Ltd. All rights reserved. Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application or trademark registration. This document contains proprietary information, which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced or translated to another langu

  • Siemens RUGGEDCOM RMC, RUGGEDCOM RMC Installation Guide Chapter 3 Communication Ports Copper Ethernet Ports 9 Communication Ports The RMC can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through . For more information on how to access the factory data file, refer to the User Guide for the RMC. Each communication port type has a specific place in the RMC chassis. 2 1 Figure 6: Port Assignment 1. Port 1 2. Port 2 Port Type 1 Fast Ethernet Port (10/100Base-TX) 2 Fast Ethernet Port (10Base-FL or 100Base-FX) The following sections describe the available ports: • Sect

  • Chapter 2 Installing the Device RUGGEDCOM RMC Installation Guide 6 Connecting AC Power • Clamping Voltage: 50 V to 200 V • Insertion Loss: < 0.1 dB at 10 MHz • Peak Surge Current: 10 kA, 8x20µs waveform The following sections describe how to connect power to the device: • Section 2.2.1, “Connecting AC Power” • Section 2.2.2, “Connecting DC Power” Section 2.2.1 C

  • Siemens RUGGEDCOM RMC, RUGGEDCOM RMC Installation Guide Chapter 6 Certification Agency Approvals 19 Certification The RMC device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. • Section 6.1, “Agency Approvals” • Section 6.2, “FCC Compliance” • Section 6.3, “Industry Canada Compliance” • Section 6.4, “EMI and Environmental Type Tests” Section 6.1 Agency Approvals Agency Standards Comments CSA CSA C22.2 No. 60950-1, UL 60950-1 Approved CE EN 60950-1, EN 61000-6-2, EN 55022 Class A, EN 60825-1 CE Compliance is claimed vi

  • Chapter 4 Technical Specifications RUGGEDCOM RMC Installation Guide 14 Fiber Optic Ethernet Port Specifications Section 4.3 Fiber Optic Ethernet Port Specifications The following details the specifications for fiber optic Ethernet ports that can be ordered with the RMC. NOTE • All optical power numbers are listed as dBm averages. To convert from average to peak add 3 dBm. To convert from p

More Instructions:

DOWNLOAD

Related Products and Documents (Media Converter):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 KYORITSU KEW1020R Instruction manual kyoritsu/kew1020r-RRA.pdf 26 Jun 2023 1
2 Monogram ZIPS360NHSS Owner's manual monogram/zips360nhss-32K.pdf 03 Jan 2024 20
3 Garmin Approach G5 - GPS-Enabled Golf Handheld Important safety and product information garmin/approach-g5-gps-enabled-golf-handheld-6G3.pdf 01 Jan 2023 46 0.56 Mb
4 Parkside PWS 230 SE - MANUEL 7 Operation and safety notes parkside/pws-230-se-manuel-7-783.pdf 29 Oct 2023 103 4.76 Mb
5 Nordson Prodigy Robot Gun Customer product manual nordson/prodigy-robot-gun-L62.pdf 17 Oct 2022 31
6 Bushnell BackTrack D-TOUR 360310BG Instruction manual bushnell/backtrack-d-tour-360310bg-GR6.pdf 14 Mar 2023 60 3.77 Mb

Similar Resources:

  • Transition Networks

    C/PS-CF-01SC

    (4 pages)
    MEDIA CONVERTER TECHNICAL SPECIFICATIONSHost Connection IBM® S/3x (System 34, 36, 38) host, AS/400™host or 5x94 remote controllerCase dimensions 4.75" x 3.0" x 1.0" (119mm x 76mm x 25mm)Shipping Weight 2 pounds (0.9 kilograms)Environment Temperature: 0-50°C (32-122°F)Humidity 10-90%, non condensing Altitude 0-10,000 feetWarranty Five year …
  • ADF Web

    HD67B09-2-B2

    (33 pages)
    Industrial Electronic Devices ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31 User Manual OPC UA Client / Modbus Slave Document code: MN67B09_ENG Revision 1.000 Page 1 of 33 User Manual Revision 1. …
  • Infineon

    D2 PAK

    (20 pages)
    User Guide Please read the Important Notice and Warnings at the end of this document Revision 1.0www.infineon.com 2018-03-01UG_1801_PL16_1802_225559Full-bridge converter for UPSD2PAK/D2PAK-7 kitAbout this documentThis user guide describes the Infineon full-bridge demo board for UPS. The current design considers only thepower section including drivers and pow …
  • Whelen Engineering Company

    E-747

    (11 pages)
    Page 1©1994 Whelen Engineering Company Inc.Form No.13585 (011501)Mass Notification®ENGINEERING COMPANY INC.For warranty information regarding this product, visit www.whelen.com/warrantyOPERATION & INSTALLATION MANUALBasic description and operationof theE-747 ENCODER WARNING: This product can expose you to chemicals including Lead which is known t …
  • Cobalt Digital Inc

    9902-UDX

    (104 pages)
    2406 E. University Ave.Urbana, IL 61802Voice 217.344.1243 • Fax 217.344.1245www.cobaltdigital.comProduct Manual9902UDX-OM (V1.3)Cobalt Digital Inc.3G/HD/SD-SDI Up-Down-Cross Converter/Framesync/Audio Embed/De-Embedwith Multi-Input Auto-Changeover9902-UDX9902-UDX …
  • Common

    CMK-03

    (86 pages)
    CMK-03 GAS VOLUME CONVERTER OPERATING INSTRUCTION Edition: CMK3 / 102U Firmware version: 2.2.39-39-2.7.8 Lodz, June 2016 Technical specification and construction may change due to improvement. This publication serves as general information only, and all specifi-cations are subject to confirmation by COMMON S …

Comments, Questions and Opinions: