Manualios.com

Siemens 7NG3092-8KU Operating Instructions Manual

Siemens 7NG3092-8KU Manual Online:

3.9, 852 votes
Siemens 7NG3092-8KU User Manual
Siemens 7NG3092-8KU User Guide
Siemens 7NG3092-8KU Online Manual

Text of Siemens 7NG3092-8KU User Guide:

  • Siemens 7NG3092-8KU, Commissioning 5.2 Commissioning the modem Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 34 Operating Instructions, 06/2014, A5E00468983-04 Note If you are using the USB modem for parameterization of SITRANS TH100/TH200/TR200/TF200/TF with TH200, do not disconnect the USB connector from the PC or the modem during the parameterization process. Note RF interference The MODEM is a class A device. This device may emit RF interference in residential areas. In this case, you need to take appropriate measures. Note Interference emission of

  • Siemens 7NG3092-8KU, Installing 4.3 Windows XP and earlier Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 Operating Instructions, 06/2014, A5E00468983-04 23 3. Select the COM port number that you have noted. This is the COM port that was displayed in "Device Manager". It was "COM3" (COM port 3) in our example. 4. Confirm the setting with "OK." Result The installation of the USB driver is completed successfully. See also Step 2: Installation of the USB modem (Page 16) 4.3.2 Uninstalling USB drivers Introduction You can uninstall the USB driver manually if you do not wish to continue using the SIPROM T parameterizat

  • Siemens 7NG3092-8KU, Installing 4.3 Windows XP and earlier Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 Operating Instructions, 06/2014, A5E00468983-04 13 Procedure Prepare for the installation of the USB modems as specified below: 1. Connect the USB modem to a free USB port of your computer using the cable provided. The 7NG3092-8KU modem is compatible with USB 1.x and USB 2.0. After plugging in, Windows opens the Hardware wizard automatically: 2. Click on the second installation option "Install from a list or specific location (Advanced)". 3. Co

  • Siemens 7NG3092-8KU, Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 Operating Instructions, 06/2014, A5E00468983-04 33 Commissioning 5 5.1 Safety notes for commissioning WARNING You must only use the 6 V power adapter provided with the device for supplying power to the RS232 modem. Connect the modem only to the prescribed SITRANS TH100/TH200/TR200/TF200/TF with TH200 transmitter. Only use the connecting cable provided with the modem for connecting the modem to the PC.

  • Siemens 7NG3092-8KU, Installing 4.3 Windows XP and earlier Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 Operating Instructions, 06/2014, A5E00468983-04 21 13.Click "Advanced..." The following window opens: 14.Select a matching port number in the "COM Port Number" field. COM numbers with the "in use" comment have already been occupied and can no longer be used. If all COM ports are occupied, one serial port must be disabled to be able to install the USB driver. Please contact your system administrator in thi

  • Installing 4.3 Windows XP and earlier Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 12 Operating Instructions, 06/2014, A5E00468983-04 3. Click "Software". 4. Click "SIPROM T". The SIPROM T parameterization software will be installed on your PC. 5. Follow the instructions and notes displayed during the installation proc

  • Siemens 7NG3092-8KU, Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY Order number: A5E00468983 Ⓟ 06/2014 Subject to change Copyright © Siemens AG 2014. All rights reserved Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury wi

  • Installing 4.3 Windows XP and earlier Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 16 Operating Instructions, 06/2014, A5E00468983-04 4.3.1.2 Step 2: Installation of the USB modem Prerequisites After executing step 1 of the installation, the Hardware wizard should open again automatically. The following window appears:

  • Siemens 7NG3092-8KU, Installing 4.4 Windows 7 and higher Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 28 Operating Instructions, 06/2014, A5E00468983-04 5. Click "Next". The USB driver is installed. The following window opens: 6. Click "Finish". 7. Check whether the system has installed the correct COM port for the SIPROM T parameterization software. To do this, proceed as described in steps 6 to 11 in chapter "Step 2: Installation of the USB modem (Page 16)".

  • Siemens 7NG3092-8KU, Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ SITRANS Accessories Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF Operating Instructions 7NG3092-8KU, 7NG3092-8KM 06/2014 A5E00468983-04 Introduction 1 General safety notes 2 Description

  • Description 3.3 Scope of delivery Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 10 Operating Instructions, 06/2014, A5E00468983-04 3.3 Scope of delivery 3.3.1 Modem with a USB connection (7NG3092-8KU) The following is supplied with your modem for SITRANS TH100/TH200/TR200/TF200/TF with TH200 with a USB connection: ● Warnings

  • Siemens 7NG3092-8KU, Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 Operating Instructions, 06/2014, A5E00468983-04 37 Operating SIPROM T 6 Introduction This section describes the most important menu items in brief. Please refer to the online help of the SIPROM T parameterization software regarding further notes for operating this software. You will find the technical details regarding the sensor characteristics of SITRANS TH100/TH200/TR200/TF200/TF with TH200 in the corresponding operating instruction

  • Siemens 7NG3092-8KU, Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 Operating Instructions, 06/2014, A5E00468983-04 43 Technical data 8 Modem for SITRANS TH100/TH200/TR200/TF200/TF with TH200 including SIPROM T parameterization software Power supply (relevant only for the RS232 version) Supply of the power adapter (power adapter is included in the scope of delivery) AC 90 ... 265 V, 50/60 Hz, max 6 W USB port (relevant only for the USB version) USB version USB 1.1, com

  • Siemens 7NG3092-8KU, Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 Operating Instructions, 06/2014, A5E00468983-04 9 Description 3 3.1 Applications The modem for SITRANS TH100/TH200/TR200/TF200/TF with TH200 is used for the operation and parameterization of the transmitters in the "Offline state". The modem is available in two different versions: ● Modem with a USB connection (order number 7NG3092-8KU) ● Modem with a RS232 connection (order number 7NG3092-8KM) These operating instructions deal with the connection of the

  • Siemens 7NG3092-8KU, Installing 4.3 Windows XP and earlier Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 14 Operating Instructions, 06/2014, A5E00468983-04 5. Click "Browse". The following window opens: 6. Select the directory in which the SIPROM T parameterization software and the USB drive were installed. The USB driver is installed in the 'C:\Program Files\SIPROM T\USB' sub-directory in case of a standard installation of the SIPROM T parameterization so

  • Siemens 7NG3092-8KU, General safety notes 2.3 Qualified Personnel Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 8 Operating Instructions, 06/2014, A5E00468983-04 2.3 Qualified Personnel "Qualified personnel" means those who are familiar with the installation, mounting, commissioning and operation of the product. They must have the following, appropriate qualifications for their activities: ● Training or instruction/authorization in operating and maintaining devices and systems according to the safety regulations for electrical circuits. ● For explosion-proof devices: Training or instruction/

  • Siemens 7NG3092-8KU, Installing 4.4 Windows 7 and higher Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 26 Operating Instructions, 06/2014, A5E00468983-04 4.4 Windows 7 and higher 4.4.1 Installing USB drivers Procedure 1. Open the SIPROM T Software directory. 2. Open the "USB/Win7&Higher" folder. 3. Right-click on the "CDM20830_Setup.exe" file and select "Execute as administrator". The following window opens:

  • Siemens 7NG3092-8KU, Commissioning 5.3 Meaning of LEDs on the modem Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 36 Operating Instructions, 06/2014, A5E00468983-04 5.3 Meaning of LEDs on the modem LEDs on the modems for the SITRANS TH100/TH200/TR200/TF200/TF with TH200 parameterization software have the following meaning: Name Color Meaning Power Green Continuous For the USB modem: Illuminates when the modem is connected to the USB port of the PC and the operating system of your PC is in the normal mode. This LED switches off if the PC is in the standby or idle mode. For the RS232 modem: Illuminates when the supply

  • Installing 4.3 Windows XP and earlier Modem and SIPROM T for SITRANS TH100/TH200/TR200/TF200/TF with TH200 18 Operating Instructions, 06/2014, A5E00468983-04 7. Double-click the "System" entry. The following window opens: 8. Click "Device Manager" in the "Hardware" tab. Windows calls up the Device Manager. The fol

Related Products and Documents (Modem):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 American DJ Aquarius 250 User instructions american-dj/aquarius-250-7PG.pdf 13 Sep 2022 8 1.45 Mb
2 Toshiba Satellite L835 Operation & user’s manual toshiba/satellite-l835-3GL.pdf 23 Dec 2022 156 5.91 Mb
3 Kenwood DP-M993 Instruction manual kenwood/dp-m993-6EX.pdf 26 Jul 2022 24
4 Intel RAID AXXRSBBU6 Operation & user’s manual intel/raid-axxrsbbu6-1C8.pdf 08 May 2023 14
5 NETGEAR SSL312 - ProSafe SSL VPN Concentrator 25 Reference manual netgear/ssl312-prosafe-ssl-vpn-concentrator-25-T82.pdf 14 Jul 2023 112
6 TRENDnet TK-208K Operation & user’s manual trendnet/tk-208k-3NN.pdf 27 Mar 2023 12 1.56 Mb

Similar Resources:

  • Cisco

    ASR 5000 Series

    (123 pages)
    Cisco ASR 5000 Enhanced Wireless Access Gateway Administration Guide Version 15.0 Last Updated November 30, 2013 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 …
  • FlexDSL

    ORION 2

    (115 pages)
    User Manual NTU Orion 2 1 FlexDSL ORION 2(+) NTU DEVICES TECHNICAL DESCRIPTION AND OPERATIONS MANUAL Version 1.4 Document name UM_Flexdsl-NTU-Orion2_V1-4.Doc Revision 18. November 2008 …
  • AOpen

    FM56-SVV

    (15 pages)
    Installation Guide of FM56-SVV Soft PCI Modem Support O/S 1. Windows 9x 2. Windows ME 3. Windows 2000 4. Windows NT 5. Windows XP Outlet Description The Appearance of PCI Modem PCI Card Bracket Connection 1 …
  • ICPDAS

    I-8120W

    (6 pages)
    I-8120W Quick Start User Guide (Version 1.2, Apr/22/2015) -----1 Quick Start User Guide 1. Introduction This user guide introduces users to apply the I-8120W in their application quickly. Therefore, if users want to know the details, please refer to the user manual of I-8120W. You can find it in the CD or the website. CD path: CAN/SlotModule/ I_8120 …
  • Telebit

    NetBlazer STi

    (48 pages)
    Part Number 90453-02 Revision A0Copyright © 1997 Telebit, Inc.Printed in U.S.A. STi and 40i Installation GuideNetBlazer®NetBlazer STi¤LAN POWER RESETNetBlazer 40iLAN POWER RESET¤ Book Page 1 Thursday, March 27, 1997 10:55 AM …
  • Cisco

    Router Cisco 3600

    (58 pages)
    CHAPTER5-1Cisco 3600 Series Hardware Installation GuideOL-2056-025Installing Memory in the RouterThis chapter describes procedures for adding and replacing memory in Cisco 3600 series routers, andcontains the following sections:• Accessing the Mainboard, page 5-2• Replacing DRAM and SDRAM, page 5-6• Replacing Flash Memory SIMMs, page 5-19• Replacing …

Comments, Questions and Opinions: