Manualios.com

Siemens SMD21300 Instruction Manual

Siemens SMD21300 Manual Online:

3.95, 1100 votes
Siemens SMD21300 User Manual
Siemens SMD21300 User Guide
Siemens SMD21300 Online Manual

Text of Siemens SMD21300 User Guide:

  • Siemens SMD21300, 10.03 Instruction Manual 6 Adjustments 6.1 Overview All displays are optimally set in the factory so that no adjustments are usually necessary. If adjustments to the settings are nevertheless required, they can be made using the VOSD and SMfit ACT (V3.0 or later) program. The VOSD program is supplied for each display as a Windows version on CD. It includes a part of the functionalities of SMfit ACT. SMfit ACT must be ordered separately. Install VOSD according to the description in the Readme.txt file on the CD. The program has two display levels: user and servicing. In the user level, only a portion of the functions are seen which are available in the s

  • Siemens SMD21300, 10.03 Instruction Manual Main menu Function Adjustment/range Description Test pattern (U) DIN geometry (U) Display test pattern DIN gray (U) Display test pattern DIN resolution (U) Display test pattern SMPTE (U) Display test pattern Grid (U) Display test pattern Briggs (U) Display test pattern Astigmatism (U) Display test pattern Dynamic focus (U) Display test pattern Static focus (U) Display test pattern VeriLUM (U) Display test pattern AAPM (U)

  • 10.03 Instruction Manual 5.2 Serial interface The display has a serial RS 232 interface with 6-contact mini-DIN socket. The following units may be connected to the socket: − Ambient lighter sensor for the SMD display range (permissible in patient environment) − Serial luminance meter with adapter from 9-contact Sub-D to 6-contact mini- DIN socket *) − Serial spot m

  • 10.03 Instruction Manual 1 Application The gray scale flat panel display SMD 21300 CS Order No.: 6GF6201-5WA01 SMD 21300 D Order No.: 6GF6201-5WA03 has been specially designed for medical diagnostics. The display is available for ceiling suspension (CS) and as a desktop version (D). The two displays differ in that the desktop version is supplied together with a stand and

  • Contents 1 Application ............................................................................................... 3 2 Safety precautions................................................................................... 4 3 Scope of delivery ..................................................................................... 6 4 Installation and assembly .......................

  • Siemens SMD21300, 10.03 Instruction Manual 5.1.2 Power supply connection Check the permissible voltage range before connecting the display (see Section 9.2). Caution Only use the power cable supplied in the delivery, or a cable with PE conductor and appliance socket to DIN 49 547, IEC 320 (max. length 3 m, cable e.g. H05VV-F 3x1.0 mm 2 ). Furthermore, the cable must correspond to the safety regulations of the specific country. Information for installations in the USA and Canada: Molded power supply plugs must comply with the requirem

  • Siemens SMD21300, 10.03 Instruction Manual 7 Operation 7.1 Switching on the display and PC • Switch on all displays and the PC (note: any switch-on sequence) • The operation LED now lights up green permanently. 7.2 Cleaning Caution Care of unit / cleaning agents • The front panel is extremely sensitive to mechanical damage. Avoid all scratches, knocks etc.! • Remove water drops immediately; extended contact with water discolors the surface. Clean the front panel when dirty using a microfiber cloth and, if necessary, a glass cleaning agent. Only clean housi

  • Siemens SMD21300, 10.03 Instruction Manual 2 Safety precautions Correct and safe operation of the display is dependent on proper transport, storage, installation and assembly, as well as careful operation and maintenance. The unit must only be used for applications normally requiring a display. The information in the Section "Technical data" must be observed exactly. In the following, Users refer to medical personnel (e.g. radiology technician, medical technician), and Servicing refers to specifically trained and authorized personnel (e.g. hospital technician, manufactur

  • Siemens SMD21300, 10.03 Instruction Manual 4 Installation and assembly Distances The unit should be positioned on a hard, level and horizontal surface. It should be positioned at least 10 cm at the side and rear from a wall or 15 cm from other units. Several displays can be butt-mounted horizontally and vertically . Mounting of unit With ceiling mounting (VESA adapter / 100 x 100 mm) or installation with the stand, proceed as follows: • Hold the display on the VESA adapter or stand, and secure with screws. • The display may only be aligned in portait format. Since the screws are extremely significant for the installation, observe the following:

  • Siemens SMD21300, 10.03 Instruction Manual 7.3 Maintenance The displays require little maintenance. Only the illumination properties slowly change due to aging of the LCD unit and the backlight. Therefore the display settings must be checked at regular intervals by servicing personnel according to the regulations, and corrected as necessary. The serial luminance meter and the serial spot meter are possible as measuring instruments. Both units can be directly connected to the display. The adjustment can be carried out automatically using the SMfit ACT program, version 3.0 or later. The settings can also be carried out manually using the

  • Siemens SMD21300, 10.03 Instruction Manual 6.3 VOSD program description Main menu Function Adjustment/range Description System (U) ISP enable (S) Button "Yes", "No" Enabling of display for single download (ISP = In System Programming) 8/10-bit video signal (S) Mode - 8-bit video input signal - 10-bit video input signal Adaptation to video output of graphics card. The corresponding data can be obtained from the graphic card's manual "monilisa" Input

  • Siemens SMD21300, 10.03 Instruction Manual 9.6 Climatic conditions Operation Ambient temperature range 0 °C to 35 °C Temperature gradient Max. 5 °C/h, no condensation Atmospheric pressure 1040 to 860 hPa Transport and storage (packed) Ambient temperature range -20 °C to +60 °C Temperature gradient Max. 5 °C/h, no condensation Atmospheric pressure 1040 to 674 hPa (0 to 3048 m) 9.7 Mechanical requirements Operation Vibration To EN 60 068-2-6 10 to 58 Hz at ± 0.075 mm deflection 58 to 500 Hz at 10 m/s² Shock To EN 60 068-2-29 150 m/s², 6 ms Packed unit Vibration To EN 60 068-2-6 5 to 9 Hz at ± 3.5 mm deflection 9 to 500 Hz at 10 m/s² Shock To

  • Siemens SMD21300, 10.03 Instruction Manual 9.3 Inputs/outputs DVI input DVI-I socket (analog pins are not used) Single link 1536 x 2048 at 60 Hz The SMG 2125 D and SDG 2125 DM graphics cards are recommended as the interface module. DDC In the DVI cable RS 232 Via mini-DIN service socket 9.4 Controls and connection elements Rear 1x power switch, 1x operation LED, 1x service socket (6-contact mini-DIN socket) Protected by a cover: 1x power supply socket, 1x DVI, 1x RJ 45, 1x USB type B (optional) Note: the display is set using the VOSD or SMfit ACT software 9.5 Mechanical des

  • Siemens SMD21300, 10.03 Instruction Manual 11 Remarks and contact address 11.1 Remarks Invalidity of guarantee All unauthorized electrical or mechanical alterations on or in the unit result in loss of the guarantee. Information on the Instruction Manual For clarity reasons, this Instruction Manual does not contain all detailed information on this product. Your attention is additionally drawn to the fact that the contents of this Instruction Manual are not part of a previous or existing agreement, commitment or statutory right and do not change the latter. Guarantee All commitments on the part of Siemens AG are conta

  • Siemens SMD21300, 10.03 Instruction Manual 3 Scope of delivery SMD 21300 CS: • Display without stand • CD with Instruction Manual and VOSD SMD 21300 D: • Display with stand • CD with Instruction Manual and VOSD • European power cable • US power cable • DVI video cable Note It is recommendable to keep the packaging material for subsequent transport of the unit. 6 21" gray scale flat panel display SMD 21300 A5E00185696B-001

  • Siemens SMD21300, 10.03 Instruction Manual 9.9 Electromagnetic compatibility EMI voltage/ radiated interference EN 60 601-1-2 Class B EN 55 011 Voltage variations EN 61 0004-11 Burst on power supply lines EN 61 000-4-4 2 kV Burst on signal line EN 61 000-4-4 1 kV Surge on power supply lines EN 61 000-4-5 1 kV symmetric, 2 kV unsymmetric Static discharge on casing parts (ESD) EN 61 000-4-2 8 kV air, 6 kV contact RF irradiation EN 61 000-4-3 80 MHz - 2500 MHz, 3 V/m 80 % AM 1 kHz EN V 50 204 (puls

Related Products and Documents (Monitor):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Martin MAC III AirFX Operation & user’s manual martin/mac-iii-airfx-9OY.pdf 26 May 2023 64
2 Enterasys SmartSwitch 6G302-06 Errata enterasys/smartswitch-6g302-06-Y1A.pdf 31 Dec 2022 1 0.01 Mb
3 Coby MP-C851 Brochure coby/mp-c851-KEM.pdf 03 Nov 2022 1 0.21 Mb
4 MiTAC 8500 Service manual mitac/8500-MS5.pdf 01 Apr 2023 179
5 Pyle PLDINTV7 Operation & user’s manual pyle/pldintv7-74H.pdf 24 Mar 2024 60
6 Truma Therme Operating instructions manual truma/therme-S18.pdf 17 Sep 2022 40

Similar Resources:

  • NEC

    FA Series

    (87 pages)
    NEC FA Series LED Wall bundle Fine Pitch LED Video Display Indoor USER GUIDE For models: LED-FA012i2-110 LED-FA015i2-137 LED-FA019i2-110 LED-FA019i2-165 2020-02-07 …
  • AG Neovo

    X-17P

    (2 pages)
    www.agneovo.comNeoV™ Optical Glass - e most trusted hard glass protection available. Only on AG Neovo displaysX-17PA brilliant display that delivers advanced design, durability and versatile performance for progressive professional environments.e X-17P is a highly durable 17” display that will deliver decades of performance. Featuring NeoV™ Optic …
  • AOC

    2436V -

    (1 pages)
    You need to connect the USB cable first to the computer in order for the USB port on the monitor to work. There are 2 USB ports on the back of the monitor 1 Flat shaped and 1 Square shaped next to the VGA input, you need to connect the Square shaped to the monitor first. …
  • KUSSMAUL

    091-84-004

    (11 pages)
    INSTRUCTION MANUALKUSSMAUL ELECTRONICS CO., INC.170 CHERRY AVE., WEST SAYVILLE, N.Y. 11796FILE: 091-84.P65 date: 06-02-99TEL: in NY 631-567-0314 TOLL FREE: 800-346-0857 FAX: 631-567-5826ENGINE IDLER MODULEPART OF A HIGH IDLE SYSTEM3 YEAR WARRANTYENGINE IDLERMODEL #091-84-005VOLTGAE MONITORMODEL #091-84-004 …
  • Riken Keiki

    RX-8500

    (58 pages)
    PT0E-1371 Portable Multi-Gas Monitor RX-8500/RX-8700 Data Logger Management Program SW-RX-8500/8700(EX) Operating Manual …
  • HP

    vf15

    (1 pages)
    hp hp pavilion pavilion vf15 vf15 15” 15” flat flat panel panel monitor monitor hp hp pavilion pavilion vf15 vf15 15” 15” flat flat panel panel monitor monitor hp hp pavilion pavilion vf15 vf15 15” 15” flat flat panel panel monitor monitor datasheet datasheet datasheet datasheet datasheet datasheet key specifications Panel Panel TypeType …

Comments, Questions and Opinions: