Text of Siemens SCALANCE W786-x User Guide:

  • Siemens SCALANCE W786-x, Mounting 5.5 Mounting with mounting plate SCALANCE W786-x Operating Instructions, 11/2014, A5E03678337-07 27 Procedure Figure 5-8 Fitting and securing the cover plate for the cable feedthrough To screw the cover plate for the cable feedthrough to the mounting plate, follow the steps below: 1. Fit the cover plate on the mounting plate from below until the two lugs (position A in the figure above) engage the lower edge of the mounting plate. 2. Secure the cover plate to the mounting plate with two M4 screws. The screws are supplied with the assembly kit.

  • Siemens SCALANCE W786-x, Technical specifications SCALANCE W786-x 60 Operating Instructions, 11/2014, A5E03678337-07 Interfaces Data W786-x RJ-45 W786C-2 RJ-45 RJ-45 jack for Ethernet 3 or 6 antenna sockets of the type R-SMA female W786-2IA RJ-45 W786C-2IA RJ-45 RJ-45 jack for Ethernet 2 internal antennas W786-2 SFP W786C-2 SFP 2 slots for SFPs Electrical data Maximum power consumption 15.6 W Maximum current consumption depending on power supply 12 to 24 VDC 1400 to 700 mA 100 to 240 VAC 264 to 144 mA Typical power consumption depending on the number of wireless ca

  • Connecting up 6.7 SFP/SFP+ transceiver SCALANCE W786-x 50 Operating Instructions, 11/2014, A5E03678337-07 You will find detailed information on installing and connecting transceivers in the "Operating Instructions SFP/SFP+ Transceiver". This document is on the CD that ships with the SCALANCE W786 or W786C. NOTICE Insert and remove

  • Siemens SCALANCE W786-x, Mounting 5.4 Mounting without an adapter (wall mounting only) SCALANCE W786-x Operating Instructions, 11/2014, A5E03678337-07 23 Procedure Figure 5-5 SCALANCE W786 wall mounting Follow the steps below to screw a SCALANCE W786 to a wall: 1. Lead the cables into the housing of the SCALANCE W786 (position A in the figure above). Note the information in the section "Connecting up cables". 2. Secure the SCALANCE W786 to the wall with three screws (position B in the figure above). The screws are not supp

  • Siemens SCALANCE W786-x, SCALANCE W786-x Operating Instructions, 11/2014, A5E03678337-07 11 Description 4 4.1 Scope of delivery The following components are supplied with the SCALANCE W786: ● SCALANCE W786 ● 5 caps for the cover screws ● Depending on the version, up to 8 plugs for sealing the housing ● Depending on the version, up to 8 strain relief clamps ● Connector for the 24 VDC power supply ● SIMATIC NET Industrial Wireless LAN CD Note The installation set with the mounting plate for attachment to an S7 -300 rail, a 35 mm DIN rail or a mast does not ship with the product. You can obtain the installation set under the follow

  • Siemens SCALANCE W786-x, Mounting 5.2 Removing / fitting the housing cover SCALANCE W786-x Operating Instructions, 11/2014, A5E03678337-07 19 Figure 5-1 Removing the cover A Sealing cap B Cover screw C Housing cover Follow the steps below to remove the housing cover: 1. Remove the sealing caps from the housing cover (position A in the figure above) 2. Loosen the screws in the cover (position B in the figure above). 3. Remove the housing cover (position C in the figure above). Fitting the housing cover Fitting the housing cover is carried out in the reverse order. Tightening torque for the c

  • Siemens SCALANCE W786-x, Connecting up 6.9 Connecting external antennas SCALANCE W786-x 54 Operating Instructions, 11/2014, A5E03678337-07 The following figure shows the interfaces of a SCALANCE W786-2 with the housing cover removed: Figure 6-8 R1: Interface for the first wireless card R2: Interface for the second wireless card. On devices with only one IWLAN interface (W786-1), this interface does not exist. For each WLAN port, there are three R-SMA sockets on a SCALANCE W786 to connect external antennas. The figure above shows how the R-SMA

  • Siemens SCALANCE W786-x, Description 4.2 LED display SCALANCE W786-x 12 Operating Instructions, 11/2014, A5E03678337-07 4.2 LED display Information on operating status and data transfer On the front of the housing, several LEDs provide information on the operating status of the SCALANCE W786: LED Color Meaning L1 Green Power supply over a power supply adapter or the 24 VDC energy con- tacts of devices with an interface for FO cable. PoE (1) Green Power over Ethernet or power over the 24 VDC energy contacts of devic- es with an RJ-45 interface. P1 Green There is a connection over the Ethernet port. (Link). Green and yel- low flashi

  • Siemens SCALANCE W786-x, Connecting up 6.10 Replacing the PLUG (C-PLUG or KEY-PLUG) SCALANCE W786-x Operating Instructions, 11/2014, A5E03678337-07 57 Licenses on the KEY-PLUG A C-PLUG only stores information about the configuration of a device. In addition to the configuration, a KEY-PLUG also contains a license with which you can enable special functions, for example iFeatures: Type Order number KEY-PLUG W780 iFeatures AP 6GK5907-8PA00 KEY-PLUG W740 iFeatures Client 6GK5907-4PA00 KEY-PLUG W700 Security 6GK5907-0PA00

  • Siemens SCALANCE W786-x, SCALANCE W786-x ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ SIMATIC NET Industrial Wireless LAN SCALANCE W786-x Operating Instructions 11/2014 A5E03678337 -07 Information on the Internet 1 Safety instructions 2 Introduction 3 Description 4 Mounting 5 Connecting up 6 Technical specifications 7 Certification 8

  • Siemens SCALANCE W786-x, Description 4.3 Reset button SCALANCE W786-x Operating Instructions, 11/2014, A5E03678337-07 15 4.3 Reset button WARNING Danger from line voltage After removing the housing cover, there is a risk of touching live parts in the area of the connecting terminals of the power supply adapter. Only authorized personnel is permitted to open the device and carry out any work on the open device (e.g. connection and disconnection of cables, operating the reset button, replacing the PLUG)! Functions of the reset button The re

  • Siemens SCALANCE W786-x, Connecting up 6.7 SFP/SFP+ transceiver SCALANCE W786-x Operating Instructions, 11/2014, A5E03678337-07 49 6.7 SFP/SFP+ transceiver Transceivers permitted for SCALANCE W786-2 SFP and W786C-2 SFP SFP/SFP+ transceivers allow the SCALANCE W786-2 SFP and W786C-2 SFP devices to be equipped with interfaces for fiber-optic cables. There are SFPs for different cable materials (multimode, single mode) and cable lengths. The following table lists the models permitted for SCALANCE W786-2 SFP and W786C-2 SFP. Transceiver Properties Order number SFP992-1 1 x 1000 Mbps, LC port optical, multimode glass, up to max. 750 m 6GK5 992-1AL0

  • Siemens SCALANCE W786-x, Mounting 5.5 Mounting with mounting plate SCALANCE W786-x 24 Operating Instructions, 11/2014, A5E03678337-07 5.5 Mounting with mounting plate 5.5.1 Fitting the mounting plate to a wall Drilling template Note Installation location The following should be noted with regard to the installation location: • Devices with an internal antenna must be aligned according to the characteristics of the internal antenna (refer to the technical specifications of the antenna --> Radiation pattern diagra

  • Siemens SCALANCE W786-x, Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY A5E03678337-07 Ⓟ 11/2014 Subject to change Copyright © Siemens AG 2011 - 2014. All rights reserved Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol.

  • Contents SCALANCE W786-x 4 Operating Instructions, 11/2014, A5E03678337-07 7 Technical specifications ........................................................................................................................ 59 7.1 Dimension drawing SCALANCE W786 ................................................................................. 61 7.2 Radiatio

  • Siemens SCALANCE W786-x, Connecting up 6.4 Connecting the power supply SCALANCE W786-x Operating Instructions, 11/2014, A5E03678337-07 43 Procedure for connecting the supplied connector for direct supply 24 VDC The cable for direct power supply is connected to the SCALANCE W786 with the supplied connector. The connector is safe against polarity reversal and can only be inserted in the left-hand half of the housing. When connecting the wires, you should therefore make sure that the connector is oriented as shown in the following figure: Figure 6-3 P

  • Siemens SCALANCE W786-x, Mounting 5.4 Mounting without an adapter (wall mounting only) SCALANCE W786-x 22 Operating Instructions, 11/2014, A5E03678337-07 5.4 Mounting without an adapter (wall mounting only) Drilling template Note Installation location The following should be noted with regard to the installation location: • Devices with an internal antenna must be aligned according to the characteristics of the internal antenna (refer to the technical specifications of the antenna --> Radiation pattern diagrams). Since the internal antennas are integrated in the housing, the location and alignment of the housing decides the radiation direction of the antennas. • There

  • Introduction 3.2 Structure of the type designations SCALANCE W786-x 10 Operating Instructions, 11/2014, A5E03678337-07 3.2 Structure of the type designations The type designation of a SCALANCE W786 is made up of several parts that have the following meaning:

  • Connecting up 6.10 Replacing the PLUG (C-PLUG or KEY-PLUG) SCALANCE W786-x 56 Operating Instructions, 11/2014, A5E03678337-07 Removing the PLUG Figure 6-9 Location of the PLUG slot with the housing cover removed Follow the steps below to remove a PLUG from the device: 1. Turn off the power to the device. 2. Remove the housing cover, see section "Removing/fitt

  • Siemens SCALANCE W786-x, SCALANCE W786-x Operating Instructions, 11/2014, A5E03678337-07 33 Connecting up 6 6.1 Lightning protection, power supply and grounding Notes on lightning protection WARNING Danger due to lightning strikes Antennas installed outdoors must be within the area covered by a lightning protection system. Make sure that all conducting systems entering from outdoors can be protected by a lightning protection potential equalization system. When implementing your lightning protection concept, make sure you adhere to the VDE 0182 or IEC 62305 standard. Sui

  • Siemens SCALANCE W786-x, Mounting 5.5 Mounting with mounting plate SCALANCE W786-x 28 Operating Instructions, 11/2014, A5E03678337-07 5.5.3 Fitting the mounting plate to an S7-300 standard rail Procedure Figure 5-9 Side view of a mounting plate on an S7-300 standard rail Follow the steps below to fit the mounting plate to an S7-300 standard rail: 1. Place the mounting plate with the two protruding catches on the top edge of the S7-300 standard rail (position A in the figure above). 2. At the bottom, the mounting plate has two lugs with holes. Screw the lugs to the S7-300 standard rail (position B in the figure above). The required scr

  • Siemens SCALANCE W786-x, Description 4.3 Reset button SCALANCE W786-x 16 Operating Instructions, 11/2014, A5E03678337-07 The reset button has the following functions: ● Restart of the device To restart the device, press the Reset button briefly. Note If you make changes to the configuration and restart immediately afterwards with the reset button, the changes may be lost. If you restart the device using the WBM (menu command "System > Restart") or using the CLI (command "restart" in the Privilege

  • Siemens SCALANCE W786-x, SCALANCE W786-x Operating Instructions, 11/2014, A5E03678337-07 67 Index A Antenna cables, 51 Antennas, 51 Article number, 9 C Connectors, 11 D Dimension drawings, 61 Documentation on the CD, 9 E Ethernet, 48 G Grounding, 33 L LED display, 12 Lightning protection, 33 Loading firmware, 15 P Power supply, 42 Primary user radar, 12 Protective caps, 11 R Reset button, 15 Resetting the device, 15 Restart of the device, 15 S Safety extra low voltage, 33, 34 Scope of delivery, 11 SELV, 33 T Technical specifications, 59 Type designations, 10

  • Siemens SCALANCE W786-x, Connecting up 6.3 Connecting the cables SCALANCE W786-x 40 Operating Instructions, 11/2014, A5E03678337-07 Figure 6-1 Connecting a cable and fitting the strain relief clamps Follow the steps below to connect cables to the SCALANCE W786: 1. Connect the cables to the appropriate contacts. (Position A in the figure above) You have the following options: – Connect cables preassembled with a connector (Ethernet, antennas) by inserting the connector into the appropriate socket. Secure antenna cables by tightening the sleeve nut of the connector (key size SW8). You will find more information on this topic

  • Siemens SCALANCE W786-x, Technical specifications 7.2 Radiation patterns diagrams of SCALANCE W786 internal antennas SCALANCE W786-x 64 Operating Instructions, 11/2014, A5E03678337-07 Vertical radiation pattern 5800 MHz

  • Siemens SCALANCE W786-x, Mounting 5.3 Laying the cables SCALANCE W786-x Operating Instructions, 11/2014, A5E03678337-07 21 Grounding terminal WARNING To operate the SCALANCE W786 safely, the chassis ground connector must have a suitable cable connected. Do not use the SCALANCE W786 without a ground cable connected. The chassis ground connector is located on the rear of the device (M4 thread). Connect the ground cable before you mount the SCALANCE W786 on a wall or on the optional mounting plate. Once the SCALANCE W786 is mounted, the connector is no longer accessible. P

Related Products and Documents (Wireless Access Point):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Kenwood KX-W4050 Instruction manual kenwood/kx-w4050-6C3.pdf 23 Nov 2022 24
2 Korg Pa300 Operation & user’s manual korg/pa300-6MX.pdf 09 Oct 2023 378
3 Fiat 500e 2016 Operation & user’s manual fiat/500e-2016-SYQ.pdf 05 Aug 2022 124
4 ASROCK Fatal1ty Z77 Professional Operation & user’s manual asrock/fatal1ty-z77-professional-2A7.pdf 24 Dec 2022 243
5 Sony SA-40SE1 Specifications sony/sa-40se1-HA2.pdf 16 Oct 2023 2 0.33 Mb
6 Teac LCHD2040 Operation & user’s manual teac/lchd2040-9X2.pdf 03 Oct 2022 24

Similar Resources:

  • Cisco

    WAP610N

    (8 pages)
    QUICK INSTALLATION GUIDE Wireless-N Access Point with Dual-BandModel: WAP610NPackage Contents• Wireless-NAccessPointwithDual-Band• SetupSoftwareandUserGuideonCD-ROM• QuickInstallationGuide• NetworkCable• PowerAdapter …
  • Shure

    SHOWLINK AD610

    (13 pages)
    1/13AD610 -- ShowLink® Access PointIMPORTANT SAFETY INSTRUCTIONS1. READ these instructions.2. KEEP these instructions.3. HEED all warnings.4. FOLLOW all instructions.5. DO NOT use this apparatus near water.6. CLEAN ONLY with dry cloth.7. DO NOT block any ventilation openings. Allow sufficient distances for adequate ventilation and install in accordance w …
  • Edimax

    EW-7416APn v2

    (2 pages)
    RRang802.11n Draft 2.0 Wireless LAN Access PointActing as a bridge between the wired Ethernet and thwireless LAN access point can let your wireless LAN network nodes.WDS Bridge Mode (Repeater Mode)The WDS (Wireless Distributed System) function let tand repeater at the same time. Users can use this feaspace like airports, hotels and schools …etc. This feane …
  • ZyXEL Communications

    EMG5523-T50B

    (2 pages)
    DeviceLabelEMG5523-T50BDual-Band Wireless AC/N Gigabit Ethernet IADQuick Start GuideENGLISH | DEUTSCH | ESPAÑOL | FRANÇAIS | ITALIANONEDERLANDS | SUOMI | PORTUGUÊSStep 1Hardware ConnectionsStep 2WiFi ConnectionCopyright © 2019 Zyxel Communications Corp. All Rights Reserved.EU ImporterZyxel Communications A/SGladsaxevej 378, 2. th. 2860 Søborg, …
  • HP

    Vectra 525

    (27 pages)
    The HP 525 is a Wi-Fi Alliance authorized Wi-Fi CERTIFIED 802.11a/b/g/n/ac product. The Wi-Fi CERTIFIED Logo is a certification mark of the Wi-Fi Alliance. HP 525 Wireless Dual-Radio 802.11ac Access Point Quick Start Guide This quick start guide shows you how to install and get started using the HP 525 Wireless Dual Radio 802.11ac Access Point (RMN BJN …
  • Zte

    ZXR10

    (168 pages)
    ZXR10Router/EthernetSwitchCommandManual(IPv6Volume)Version4.8.22ZTECORPORATIONZTEPlaza,KejiRoadSouth,Hi-TechIndustrialPark,NanshanDistrict,Shenzhen,P .R.China518057Tel:(86)75526771900Fax:(86)75526770801URL:http://ensupport.zte.com.cnE-mail:[email protected]

Comments, Questions and Opinions: