  • Siemens SCALANCE M874-2, SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 31 Connecting up 3 3.1 Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. WARNING The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS). This means that only SELV / LPS complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1 must be connected to the power supply terminals. The power supply unit for the equipment power supply must comply with N

  • SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 59 Approvals A A.1 Note - products in general without shipbuilding approvals Approvals issued Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the followin

  • Technical specifications 5.3 SCALANCE M876-3 SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 55 5.3 SCALANCE M876-3 M874-3 Order number 6GK5876-3AA02-2BA2 Ethernet interface Attachment to Industrial Ethernet Quantity 4 Design RJ-45 jack Characteristics: • 10/100BASE-T • Ethernet IEEE 802 • 10/1

  • Siemens SCALANCE M874-2, SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 3 Preface Purpose of the Operating Instructions These compact operating instructions contain information with which you will be able to install and connect up a device of the SCALANCE M874, M876 product line. The configuration and the integration of the device in a network are not described in these instructions. Validity of the manual These operating instructions apply to the following devices: ● SCALANCE M874-2 ● SCALANCE M874-3 �

  • Siemens SCALANCE M874-2, Approvals A.2 INSTALLATION SCALANCE M874, M876 60 Operating Instructions, 07/2014, C79000-G89760-C331-03 A.2 INSTALLATION WARNING Personal injury and property damage can occur The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility. Only use expansions that are approved for the system. ● Keep to the installation guidelines The devices meet the requirements if you adhere to the installation and safety instructions contained in this

  • Siemens SCALANCE M874-2, Connecting up 3.6 Antennas SCALANCE M874, M876 40 Operating Instructions, 07/2014, C79000-G89760-C331-03 WARNING Danger due to lightning strikes Installing this lightning protector between an antenna and a SCALANCE M-800 is not adequate protection against a lightning strike. The LP798-1N lightening protector only works within the framework of a comprehensive lightning protection concept. If you have questions, ask a qualified specialist company. Note The requirements of EN61000 -4-5, "Surge Immunity Test" on power supply lines with 24 VDC

  • Siemens SCALANCE M874-2, Connecting up 3.8 Replacing the PLUG SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 43 3.8 Replacing the PLUG NOTICE Do not remove or insert a C-PLUG / KEY-PLUG during operation! A PLUG may only be removed or inserted when the device is turned off. The device checks whether or not a PLUG is present at one second intervals. If it is detected that the PLUG was removed, there is a restart. If a valid KEY-PLUG was inserted in the device, the devi

  • Siemens SCALANCE M874-2, Technical specifications 5.1 SCALANCE M874-2 SCALANCE M874, M876 50 Operating Instructions, 07/2014, C79000-G89760-C331-03 M874-2 Electrical data Power supply Input voltage 12 ... 24 VDC min. 10.8 VDC, max. 28.8 V Power consumption max. 8 W Digital input Quantity 1 Design Terminal block, 2 terminals Characteristics: Rated voltage 24 VDC Safe Extra Low Voltage (SELV) For state "1": 13 to 30 VDC For state "0": -30 to 3 VDC Maximum input current 8 mA Maximum cable length 30 m Inputs isolated from electronics. Digital output Quantity 1 Design Termina

  • Siemens SCALANCE M874-2, Approvals A.10 Conformity with FCC SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 67 A.10 Conformity with FCC FCC approval Applied standards ● FCC Part 15 ● FCC Part 15.19 ● FCC Part 15.21 Mandatory user information FCC Part 15 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential ins

  • Siemens SCALANCE M874-2, Technical specifications 5.3 SCALANCE M876-3 SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 57 M874-3 Product functions Firewall and security • Stateful inspection • Packet filter • IPsec VPN for up to 20 connections • Password protection Router functions • NAPT (port forwarding) • NAT (IP masquerading) • NAT traversal • 1:1 NAT • Dynamic DNS client • DNS cache • NTP • Remote logging • Connection monitoring • Alarm SMS • Sending SMS messages fr

  • Siemens SCALANCE M874-2, Preface SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 5 Security messages Note Siemens offers IT security mechanisms for its automation and drive product portfolio in order to support the safe operation of the plant/machine. Our products are also continuously developed further with regard to IT security. We therefore recommend that you regularly check for updates of our products and that you only use the latest versions. You will find information in: ( http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo2&aktprim=99&lang= en ) Here, you can reg

  • Siemens SCALANCE M874-2, Approvals A.10 Conformity with FCC SCALANCE M874, M876 68 Operating Instructions, 07/2014, C79000-G89760-C331-03 FCC ID used: QIPPHS8-P (GSM module) This device contains GSM, GPRS Class12 and EGPRS Class 10 functions in the 900 and 1800 MHz band that may not be used in territories of the USA. This device can be used for mobile and fixed applications. Internal / external antennas used with this device must be at a distance of at least 20 cm from all persons and must not be located so that they operate in combination with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating cond

  • Siemens SCALANCE M874-2, Description of the device 1.6 C-PLUG and KEY-PLUG SCALANCE M874, M876 20 Operating Instructions, 07/2014, C79000-G89760-C331-03 1.6 C-PLUG and KEY-PLUG How it works The C-PLUG or KEY-PLUG is used to transfer the configuration of the old device to the new device when a device is replaced. NOTICE Do not remove or insert a C-PLUG / KEY-PLUG during operation! A PLUG may only be removed or inserted when the device is turned off. The device checks whether or not a PLUG is present at one second i

  • SCALANCE M874, M876 ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ SIMATIC NET Industrial Remote Communication Remote Networks SCALANCE M874, M876 Operating Instructions 07/2014 C79000 -G89760-C331-03 Preface Description

  • Siemens SCALANCE M874-2, Connecting up 3.3 Power supply SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 35 External power supply Note Permitted external power supplies The power supply unit to supply the SCALANCE M -800 must comply with the requirements for a limited power source according to IEC/EN 60950 -1, section 2.5. The external power supply for the SCALANCE M -800 must meet the requirements for NEC class 2 circuits as specified in the National Electrical Code ® (ANS

  • Siemens SCALANCE M874-2, Description of the device 1.5 SET button SCALANCE M874, M876 18 Operating Instructions, 07/2014, C79000-G89760-C331-03 1.5 SET button With a SCALANCE M-800, the SET button is on the front of the housing beside the LED display. The SET button has the following functions: ● Restart Hold down the button for longer than 3 seconds to run a restart. ● Loading new firmware If the normal procedure with the "Load & Save" menu of Web Based Management does not work, the reset button can be used to load new firmware. This situation can occur if there is a power outage during the normal firmware update. – Hold down the button until the red fault LE

  • Siemens SCALANCE M874-2, Approvals A.4 ATEX SCALANCE M874, M876 64 Operating Instructions, 07/2014, C79000-G89760-C331-03 A.4 ATEX Explosion protection directive (ATEX) The SIMATIC NET product meets the requirements of the EC directive:94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres". WARNING When using (installing) SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions are adhered to: You will find these conditions on the SIMATIC NET Manual Collection. • "Approval of SIMATIC/ SIMATIC NET Products for Direct Installation i

  • SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 7 Table of contents Preface ................................................................................................................................................... 3 1 Description of the device .................................................................................................

  • Siemens SCALANCE M874-2, Connecting up 3.2 SIM card SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 33 3.2 SIM card NOTICE Turn off the power supply before replacing SIM cards Before you insert or remove the SIM card, turn off the power supply of the M-800. Do not open the compartment for the SIM card during operation. This can damage the SIM card and the device. Procedure 1. The compartment for the SIM card is located on the back of the device. Directly beside to the compartment for the SIM card in the opening in the housing, there is a small button. To open the drawer, press the button with a s

  • Siemens SCALANCE M874-2, Installation 2.4 Installing on the S7-300 standard rail SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 27 2.4 Installing on the S7-300 standard rail Requirement There is a SIM card for the device. Installation 1. Insert the SIM card, see section "SIM card (Page 33)". 2. Place the second housing guide of the device on the top edge of the standard rail ①. 3. Press the device down against the standard rail until the spring catch locks in place ②. 4. Connect the power supply, refer to the section "Power supply (Page 34)". 5. Connect the connectors for the digital input to the digital output, see section &qu

  • Siemens SCALANCE M874-2, Preface SCALANCE M874, M876 4 Operating Instructions, 07/2014, C79000-G89760-C331-03 ● "Passive network components" system manual This system manual contains installation instructions for several of the most common components and guidelines for setting up networked automation plants in buildings. The "Passive Network Components" system manual can be found on the Internet pages of Siemens Industry Online Support under the following entry ID:84922825 (http://support.automation.siemens.com/WW/view/en/84922825 ) SIMATIC NET manuals You will find SIMATIC NET manuals on the Internet pages of Siemens Industry O

  • Technical specifications 5.2 SCALANCE M874-3 SCALANCE M874, M876 52 Operating Instructions, 07/2014, C79000-G89760-C331-03 5.2 SCALANCE M874-3 M874-3 Order number 6GK5 874-3AA00-2AA2 Ethernet interface Attachment to Industrial Ethernet Quantity 2 Design RJ-45 jack Characteristics: • 10/100BASE-T • Ethernet IEEE 802 • 10/100 Mbps

  • Siemens SCALANCE M874-2, Description of the device 1.4 LED display SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 15 LED Status Meaning SC OFF SIM card OK, no connection. ON Wrong PIN number / SIM card error ON Connection established Q OFF No reception Signal strength: < -109 dBm Flashing Signal strength poor: -89 dBm to -109 dBm On Signal strength medium: -73 dBm to -89 dBm ON Signal strength good: > -73 dBm OFF VPN not established ON VPN established P1/P2 OFF Ethernet connection to local computer or LAN not established ON Ethernet connection to local com

  • Siemens SCALANCE M874-2, Connecting up 3.6 Antennas SCALANCE M874, M876 Operating Instructions, 07/2014, C79000-G89760-C331-03 39 3.6 Antennas Note Use the antennas from the accessories program for the M -800 device. You will find more detailed information in " Accessories (Page 13)". If you use a different antenna, there is no guarantee that the device will function according to the specification. The antenna socket for connecting the antenna is of the type SMA. The antenna used should have an impedance of about 50 ohms. CAUTION Minimum clearance to the device The device may only be operated when th

Related Products and Documents (Wireless Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Yamaha PSR-A3 Operation & user’s manual yamaha/psr-a3-45O.pdf 03 Mar 2023 87 6.17 Mb
2 Xantech AM/FM Radio Tuner Owner's manual xantech/am-fm-radio-tuner-2Y9.pdf 23 Jun 2023 13 2 Mb
3 Worcester Greenstar 12i System ErP Instruction manual worcester/greenstar-12i-system-erp-R2T.pdf 05 Apr 2023 74
4 ADC TrueNet Augmented Category 6 Patch Cords Specification sheet adc/truenet-augmented-category-6-patch-cords-9AI.pdf 01 Aug 2023 2 0.12 Mb
5 York Survey Supply 354420 Operating instructions york-survey-supply/354420-7XM.pdf 25 Jun 2023 2
6 Nexcom APPC 1230T Operation & user’s manual nexcom/appc-1230t-HUS.pdf 29 Feb 2024 130

Similar Resources:

  • TUYA

    WB2L

    (29 pages)
    WB2L Module DatasheetHardware Product Development > Network Modules > Wi-Fi & BLEDual Mode Module > WB Series ModuleVersion: 20210105Online Version …
  • NETGEAR

    SXR50

    (228 pages)
    User ManualOrbi Pro WiFi 6 AX5400 Tri-bandWiFi SystemModelsOrbi Pro WiFi 6 AX5400 Router Model SXR50Orbi Pro WiFi 6 AX5400 Satellite Model SXS50NETGEAR, Inc.350 E. Plumeria DriveFebruary 2022San Jose, CA 95134, USA202-12551-01 …
  • Creative

    Blaster Modem

    (2 pages)
    Sound Blaster® Wireless TransmitterYour transmitter is operational without any software installation. However, to enjoy all the features, install the drivers and applications provided on the installation CD. NOTE You can also download the software from www.creative.com/support. Simply select your audio device from the list of products shown on the suppor …
  • Samsung

    DA-E670

    (35 pages)
    Wireless Audio with Dockuser manualimagine the possibilitiesThank you for purchasing this Samsung product.To receive more complete service, please register your product atwww.samsung.com/registerDA-E670 …
  • TerraTec

    NOXON

    (30 pages)
    QUICK SETUP GUIDE (DEUTSCH) QUICK SETUP GUIDE (ENGLISH) GUIDE D'INSTALLATION RAPIDE (FRANCAIS) QUICK SETUP GUIDE (ITALIANO) GUÍA RÁPIDA DE PUESTA EN MARCHA (ESPANOL) QUICK SETUP GUIDE (NEDERLANDS) GUIA DE INSTRUÇÕES RÁPIDAS (PORTUGUES) …
  • NETGEAR

    DG834N

    (2 pages)
    2.4 GHzdraft 802.11 nRangeMax™ Ne x t Wireless-N Broadband Modem Router Data SheetDG834N Experience the Next generation of Wireless Networking• Simultaneously stream HD video, play games online, make Internet phone calls and surf the Web without wires• Share your broadband Internet connection simply and securely• Easy set …

Comments, Questions and Opinions: