Solibro SL2 Installation And Operation Manual
|
Solibro SL2, 11 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 ¼ Check the packaging for damage. ¼ I f t he packaging is damaged, contact the shipping company ¼ F ollow the packaging instructions DANGER! Danger due to electric shock! ¼ D o not install damaged modules ¼ Report any damage to your dealer immediately 3 MONTAGE 3.1 SAFETY AND TRANSPORT Leave the modules in the original packaging right up until installation Store the modules securely in dry rooms. The packaging is not weatherproof! DANGER! Danger due to electric shock! ¼ C o ver the modules with lightproof material for the duration o
Solibro SL2, 10 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 2 PLANNING 2.4 ELECTRICAL LAYOUT R e quirements on the system You can nd the detailed electrical parameters in the product da ta sheet. ¼ Only connect modules of the same type and the same power class. ¼ The voltage limitation of the inverter must also be taken into account in the layout of the string length. ¼ Do not operate modules in short circuit. ¼ D o not operate modules longer than 90 days in open terminal voltage. Saf ety factor During normal operation, the module may provide a greater current and/or a higher voltage
Solibro SL2, 2 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 1 INTRODUCTION 3 2 PLANNING 4 2.1 Technical data 4 2.2 Requirements 5 2.3 Mounting variants 8 2.4 Electrical layout 10 3 INSTALLATION 11 3.1 Safety and transport 11 3.2 Preparation for installation 13 3.3 Module installation 14 4 ELECTRICAL CONNECTION 15 4.1 Safety 15 4.2 S
Solibro SL2, 8 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 2.3 MOUNTING OPTIONS A pproved clamp areas and mounting options for the solar modules (top view). The specied dimensions (in mm) refer to the clearance between the module edge and the middle of the clamp. The illustrated mounting variants apply for installation in portrait and landscape format. Unframed modules Mo unting with clamps Insertion prole system The mounting option described for unfr
Solibro SL2, 5 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 2.2 REQUIREMENTS Installation location The following information is intended to serve as a guide for the planner. I t c annot cover all of the technical possibilities and mounting options. Rather, it sets out the minimum requirements for mounting the modules. Comply with the following notes on the installation location: The modules are t ested in accordance with IEC 61646, 61730 and UL 1703 for safe use in a moderate climate. Modules are no t explosion-proof devices. ¼ Donotoperatethemodulesnearhighl
Solibro SL2, 6 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 Requirements on the clamping system for unframed modules On ly clamp systems approved by Solibro may be installed. The list of all approved clamps is available at www.solibro-solar.com. On r equest, Solibro can test clamp systems and approve them following successful testing. ¼ A ll contact between the metal of the clamps and the module glass must be prevented. ¼ U s e a suitable silicone-free rubber support plate between the
21 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 9 ADDITIONAL INFORMATION Required information in accordance with IEC -61730: TheSolibromodulesoftheseriesSL2andSL2-Farequalied for application class A up to a height of 2,000 m. ModulescertiedforapplicationclassAcan�
Solibro SL2, 15 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 DANGER! Danger due to electric shock! ¼ In sulate exposed cable ends. ¼ Only connect cables with plugs. 4.1 SAFETY DANGER! Da nger due to electric shock! When disconnecting an electric circuit transporting direct current, electric arcs can occur that can result in life-threatening injuries. ¼ Do not disconnect the cable and plug while they are energized. ¼ D o not touch the poles at the same time. Even at a low illuminance level, a solar module generates elec
Solibro SL2, 18 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 5.1 FUNCTIONAL GROUNDING OF THE NEGATIVE POLE S olibro solar modules are to be principally protected against nega- tive voltages with regard to the ground potential on the generator pole! In most cases, this is realized by connecting the negative pole of the array (systems with galvanic separation between the direct and alternating voltage sides) with the ground potential. Many inverter manufacturers offer grounding kits for their inverters: ¼ Functional grounding of the negative pole PV s ystem Functional grounding kit negative �
Solibro SL2, 16 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 click DANGER! Danger due to electric shock! ¼ Alwayscomplywiththespeciedtimeinter- vals from switching off the inverter to starting further work. 4.2 SAFETY DURING ELECTRICAL INSTALLATION WORK 4 ELECTRICAL CONNECTION DANGER! Danger due to electric shock! ¼ Ne ver disconnect the plugs in energised state. 1. Switch off the inverter. 2. Keep the D C side free with isolators. 3. Cover modules that need to be separated. DC SWITCH OFF DANGER! Danger due to elect
Solibro SL2, 19 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 5.2 POTENTIAL EQUALIZATION When using framed Solibro products, it must be ensured that no potential difference between the frame and the substructure exists. There are two options available for this: Option 1: Usage o f g rounding c lamps w ith g rounding f unction s pecied i n the approved Solibro clamps list. On request, Solibro can test clamp systems and approve them following successful testing. Option 2: If u sing clamps without grounding function the potential equ
Solibro SL2, 17 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 4.4 AFTER THE INSTALLATION 4 ELECTRICAL CONNECTION ¼ Carry out all necessary safety and functional tests according to the current state of technology. ¼ Protect the cabling from dirt and wet. ¼ Ensure that the substructure is on ground p otential:(Groundresistance≤10Ω) ¼ Fix the cable properly to the substructure. The connectors must not lie in water.
3 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 1 INTRODUCTION Validcountry-speciclaws,regulationsandrequirementsfor planning, installation and operation of solar po wer plants and working on the roof. V alid int ernational, national and regional regulations, in par- ticular regardin
Solibro SL2, 12 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 NOTE! Damage to the modules! ¼ Ne ver stand on the modules. ¼ Do not apply mechanical stress to the modules. ¼ D o not drop objects on the modules. NOTE! Damage to the modules! ¼ N e ver lift or move the modules by the connec- tion cables or the junction box. NOTE! Damage to the modules! ¼ D o not stack the modules. NOTE! Damage to the modules! ¼ D o not drop the modules. 3 INSTALLATION Note! Damage to the modules! ¼ U s e glass suction cups to remove and trans- port modules. ¼ Ca rry the modules vertically. NOTE! Damage to the modules! �
Solibro SL2, 14 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 90° ¼ Position the modules plane. ¼ D o not subject modules to mechanical stress. Max.torsionof3mm/m. 10mm 10mm Installing unframed modules ¼ P lease note the requirements on the clamping system out- lined in Chapter 2. ¼ Lay anti-slip protection between the module clamp and the substructure. Module clamp Anti-slip protection Rubber Installing framed modules ¼ P lease note the requirements on the clamping system out- lined in Chapter 2. ¼ T ighten the clamps for framed modules with a torque of 18 N m
Solibro SL2, 20 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 ¼ Remove soiling from the substructure (leaves, bird nests etc.). 6 CLEANING AND MAINTENANCE Solibro solar modules stand for a long useful life and minimal maintenance effort and expense. Light soiling is usually washed away by rain. Cleaning is necessary when the module is shaded by heavier soiling (e.g. plants, bird droppings). This can reduce the output of the module. Ma intenance ¼ Anannualmaintenancebyaspecialistrmisrecommen
4 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 76 76 +3 –1 796.1 789.5 –1 +3 +3 1190 –1 30 +3 1196.6 -1 23 ± 0.5 +20 855 –0 +20 735 –0 +20 855 –0 +20 735 –0 7.3±0.5 23±0.5 58 30 58 7.3±0.5 Fig. 1: External dimensions (in mm) and components for SL2 and SL2-F Fig. 2: Module label SL2 & SL2-F Com ponen
Solibro SL2, 9 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 Framed modules The listed mounting variants are valid for point mounting and linear mounting. * TestLoad=γ m x Design Load γ m ≥1.5(observeregionalrequirements) Clamp area [x] Substructure lateral Point mounting Cl amp area [x] Substructure longitudi- nal Linear mounting Design load Permissible static load [Pa] Test load with safety factor γ m =1.5 [Pa]* 150 mm - 250 mm − 3,600 1,600 5,400 2,400 125 mm - 275 mm 150 mm - 275 mm 2,900 1,600 4,400 2,400 100 mm - 300 mm 100 mm - 325 mm
DOWNLOAD |
Siemens Be inspired M55 Solar panel Operation & user’s manual
Be inspired M55 |
Viessmann Vitosol 200-T Solar panel Installation instructions manual
Vitosol 200-T |
Hobo SOLAR-15W Solar panel Installation instructions
SOLAR-15W |
HHV SOLAR HSTXY24xxxZ Solar panel Installation manual
HSTXY24xxxZ |
Amerisolar AS-6P18 Solar panel Installation manual
AS-6P18 |
BayWa closed II Solar panel Installation manual
closed II |
Xiamen Antai New Energy Antai Rail? Solar panel Installation manual
Antai Rail? |
Panasonic VBHN225DJ06 Solar panel General installation manual
VBHN225DJ06 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | SOMFY | 5012941 | Manual | somfy/5012941-T9Z.pdf | 03 Jul 2022 | 2 | 4.15 Mb |
2 | Citronic | MPCD-S6 | Owner's manual | citronic/mpcd-s6-CCQ.pdf | 12 Feb 2023 | 12 | |
3 | Teltonika | MVC300 | Operation & user’s manual | teltonika/mvc300-YT4.pdf | 23 Feb 2024 | 14 | |
4 | Zelmer | ZJP1300B | Operation & user’s manual | zelmer/zjp1300b-QGI.pdf | 21 Mar 2023 | 63 | |
5 | StarTech.com | SV431USBAE | Instruction manual | startech-com/sv431usbae-9IC.pdf | 28 Dec 2023 | 9 | 0.18 Mb |
6 | Billion | BiPAC 7100SV | Quick start manual | billion/bipac-7100sv-QPX.pdf | 19 Feb 2024 | 14 | 0.52 Mb |
Viessmann
Installation instructionsfor contractorsVIESMANNVitosol-FType SV and SHFlat-plate collector for pitched roofs, roof integrationVITOSOL-F5604 068 GB 4/2012Dispose after installation.
…
Vitosol-F(80 pages) |
Carbest
SOLARKOFFERFOLDABLE SOLAR KIT825030DE – BENUTZERHANDBUCHUK – USER'S INSTRUCTIONU S B5 V / 1.2 A5 m CABLEINCL. 3 ADAPTER MONOCRYSTALLINEINCL. SOLAR CHARGECONTROLLER 120WAT TPOWERSIZE (mm)1010x 690x 30OPENSIZE (mm)CLOSED690 x 505 x 60
…
825030(16 pages) |
Carmanah
E / F Series TRAFFIC BEACON USER MANUAL Carmanah Technologies Corp. | 250 Bay St, Victoria, BC V9A 3K5, Canada | 1.250.380.0052 | [email protected] | carmanahtraffic.com For the R920-E/F, R820-E/F, R829-E/F, and R247-E/F flashing beacons 84323_MANUAL_TRA_E-F-Series_RevA
…
E Series(75 pages) |
PowerTech
45 WATT SOLAR KITINSTRUCTION MANUALMP-4554Distributed by:Electus Distribution Pty. Ltd.320 Victoria RoadRydalmere NSW 2116 AustraliaPhone: 1300 738 555 Facsimile: 1300 738 500www.electusdistribution.com.auMade in China
…
MP-4554(6 pages) |
REYNAERS
Opening CSReynaers Tab's opening cs-eco sy1 1Reynaers Tab's opening cs-eco sy1 1 12-04-2007 11:33:4112-04-2007 11:33:41Edition 08/2010 (based on 089.L56A.00)BS 30 SolarBS 30 Solar
…
BS 30 Solar(12 pages) |
Aleo
Please read this carefully prior to installation. Store in a safe place for maintenance.Quick Reference Manual Rel. 4.7, 08+/2020, en-GB-DE (1)JD00000 10-ENwith frames for roof integration S83 sol, S81 solFor the aleo moduleswith standard frames 42mm X63, X83 X61, X83INSTALLATION MANUALwith standard frames 35mm P23
…
X63(20 pages) |
Yamaha Monitor MSP7StudioMSP7Studio Owner's manual - C13QV9 MSP7Studio, 16 |
Festo Touch terminals MPA-SManual for Festo MPA-S Touch terminals MPA-S, 174 |
GSS Switch PSPT 1000#AA968E: PSPT 1000 Switch Assembly instruction manual PSPT 1000, 33 |
Marksa Other CSSW 50User Guide: Marksa CSSW 50 (8H73DV, Upd.Sunday 28-01-2024) CSSW 50, 100 |
Mikrofill Boiler Ethos 30/36Ethos 30/36 Installation & maintenance instructions manual - 37FW16 Ethos 30/36, 49 |
Virutex Power Tool U78PDF User Guide (@159Y41), Virutex U78 Power Tool (21.08.2023) U78, 3 |
MicroBoards Technology Copier NX1-1000Copier Specification sheet (MicroBoards Technology NX1-1000) NX1-1000, 1 |
Edge-Core Network Router ECS4310-26TNetwork Router PDF Installation manual ECS4310-26T, 74 |
Fisher & Paykel Refrigerator RS90A#76M1Y5: RS90A Refrigerator Installation manual RS90A, 28 |
Horizon Hobby Toy Mosquito MK VIToy PDF Instruction manual Mosquito MK VI, 34 |
Goodman Heat Pump GSH130181A SeriesGoodman GSH130181A Series Guide (Technical information manual), @8G794P GSH130181A Series, 44 |