Manualios.com

Solibro SL2 Installation And Operation Manual

Solibro SL2 Manual Online:

3.65, 2944 votes
Solibro SL2 User Manual
Solibro SL2 User Guide
Solibro SL2 Online Manual

Text of Solibro SL2 User Guide:

  • Solibro SL2, 11 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 ¼ Check the packaging for damage. ¼ I f t he packaging is damaged, contact the shipping company ¼ F ollow the packaging instructions  DANGER! Danger due to electric shock! ¼ D o not install damaged modules ¼ Report any damage to your dealer immediately 3 MONTAGE 3.1 SAFETY AND TRANSPORT  Leave the modules in the original packaging right up until installation  Store the modules securely in dry rooms. The packaging is not weatherproof!  DANGER! Danger due to electric shock! ¼ C o ver the modules with lightproof material for the duration o

  • Solibro SL2, 10 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 2 PLANNING 2.4 ELECTRICAL LAYOUT R e quirements on the system You can nd the detailed electrical parameters in the product da ta sheet. ¼ Only connect modules of the same type and the same power class. ¼ The voltage limitation of the inverter must also be taken into account in the layout of the string length. ¼ Do not operate modules in short circuit. ¼ D o not operate modules longer than 90 days in open terminal voltage. Saf ety factor During normal operation, the module may provide a greater current  and/or  a  higher  voltage 

  • Solibro SL2, 2 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 1 INTRODUCTION 3 2 PLANNING 4 2.1 Technical data 4 2.2 Requirements 5 2.3 Mounting variants 8 2.4 Electrical layout 10 3 INSTALLATION 11 3.1 Safety and transport 11 3.2 Preparation for installation 13 3.3 Module installation 14 4 ELECTRICAL CONNECTION 15 4.1 Safety 15 4.2 S

  • Solibro SL2, 8 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 2.3 MOUNTING OPTIONS A pproved  clamp  areas  and  mounting  options  for  the  solar  modules  (top  view).  The  specied  dimensions  (in  mm)  refer  to  the  clearance  between the module edge and the middle of the clamp. The illustrated mounting variants apply for installation in portrait and landscape format. Unframed modules Mo unting with clamps Insertion prole system The mounting option described for unfr

  • Solibro SL2, 5 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 2.2 REQUIREMENTS Installation location The following information is intended to serve as a guide for the planner. I t c annot cover all of the technical possibilities and mounting options. Rather, it sets out the minimum requirements for mounting the modules. Comply with the following notes on the installation location:  The modules are t ested in accordance with IEC 61646, 61730 and UL 1703 for safe use in a moderate climate.  Modules are no t explosion-proof devices. ¼ Donotoperatethemodulesnearhighl

  • Solibro SL2, 6 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 Requirements on the clamping system for unframed modules On ly clamp systems approved by Solibro may be installed. The list of all approved clamps is available at www.solibro-solar.com. On r equest, Solibro can test clamp systems and approve them following successful testing. ¼ A ll contact between the metal of the clamps and the module glass must be prevented. ¼ U s e a suitable silicone-free rubber support plate between the

  • 21 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 9 ADDITIONAL INFORMATION Required information in accordance with IEC -61730:   TheSolibromodulesoftheseriesSL2andSL2-Farequalied for application class A up to a height of 2,000 m.   ModulescertiedforapplicationclassAcan�

  • Solibro SL2, 15 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2  DANGER! Danger due to electric shock! ¼ In sulate exposed cable ends. ¼ Only connect cables with plugs. 4.1 SAFETY DANGER! Da nger due to electric shock! When disconnecting an electric circuit transporting direct current, electric arcs can occur that can result in life-threatening injuries. ¼ Do not disconnect the cable and plug while they are energized. ¼ D o not touch the poles at the same time. Even at a low illuminance level, a solar module generates elec

  • Solibro SL2, 18 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 5.1 FUNCTIONAL GROUNDING OF THE NEGATIVE POLE S olibro solar modules are to be principally protected against nega- tive voltages with regard to the ground potential on the generator pole! In most cases, this is realized by connecting the negative pole of the array (systems with galvanic separation between the direct and alternating voltage sides) with the ground potential. Many inverter manufacturers offer grounding kits for their inverters: ¼ Functional grounding of the negative pole  PV s ystem Functional grounding kit negative �

  • Solibro SL2, 16 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 click  DANGER! Danger due to electric shock! ¼  Alwayscomplywiththespeciedtimeinter- vals from switching off the inverter to starting further work. 4.2 SAFETY DURING ELECTRICAL INSTALLATION WORK 4 ELECTRICAL CONNECTION  DANGER! Danger due to electric shock! ¼ Ne ver disconnect the plugs in energised state. 1. Switch off the inverter. 2. Keep the D C side free with isolators. 3. Cover modules that need to be separated. DC SWITCH OFF  DANGER! Danger due to elect

  • Solibro SL2, 19 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 5.2 POTENTIAL EQUALIZATION When using framed Solibro products, it must be ensured that no potential difference between the frame and the substructure exists. There are two options available for this: Option 1: Usage o f g rounding c lamps w ith g rounding f unction s pecied i n the approved Solibro clamps list. On request, Solibro can test clamp systems and approve them following successful testing. Option 2: If u sing clamps without grounding function the potential equ

  • Solibro SL2, 17 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 4.4 AFTER THE INSTALLATION 4 ELECTRICAL CONNECTION ¼ Carry out all necessary safety and functional tests according to the current state of technology. ¼ Protect the cabling from dirt and wet. ¼ Ensure that the substructure is on ground p otential:(Groundresistance≤10Ω) ¼ Fix the cable properly to the substructure. The connectors must not lie in water.

  • 3 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 1 INTRODUCTION  Validcountry-speciclaws,regulationsandrequirementsfor planning, installation and operation of solar po wer plants and working on the roof.  V alid int ernational, national and regional regulations, in par- ticular regardin

  • Solibro SL2, 12 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2  NOTE! Damage to the modules! ¼ Ne ver stand on the modules. ¼ Do not apply mechanical stress to the modules. ¼ D o not drop objects on the modules.  NOTE! Damage to the modules! ¼ N e ver lift or move the modules by the connec- tion cables or the junction box.  NOTE! Damage to the modules! ¼ D o not stack the modules.  NOTE! Damage to the modules! ¼ D o not drop the modules. 3 INSTALLATION  Note! Damage to the modules! ¼ U s e glass suction cups to remove and trans- port modules. ¼ Ca rry the modules vertically.  NOTE! Damage to the modules! �

  • Solibro SL2, 14 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 90° ¼ Position the modules plane. ¼ D o not subject modules to mechanical stress. Max.torsionof3mm/m. 10mm 10mm Installing unframed modules ¼ P lease note the requirements on the clamping system out- lined in Chapter 2.    ¼ Lay anti-slip protection between the module clamp and the substructure.  Module clamp  Anti-slip protection  Rubber Installing framed modules ¼ P lease note the requirements on the clamping system out- lined in Chapter 2. ¼ T ighten the clamps for framed modules with a torque of 18 N m

  • Solibro SL2, 20 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 ¼ Remove soiling from the substructure (leaves, bird nests etc.). 6 CLEANING AND MAINTENANCE Solibro solar modules stand for a long useful life and minimal maintenance effort and expense. Light soiling is usually washed away by rain. Cleaning is necessary when the module is shaded by heavier soiling (e.g. plants, bird droppings). This can reduce the output of the module. Ma intenance ¼ Anannualmaintenancebyaspecialistrmisrecommen

  • 4 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 76 76 +3 –1 796.1 789.5 –1 +3 +3 1190 –1 30 +3 1196.6 -1 23 ± 0.5 +20 855 –0 +20 735 –0 +20 855 –0 +20 735 –0 7.3±0.5 23±0.5 58 30 58 7.3±0.5 Fig. 1: External dimensions (in mm) and components for SL2 and SL2-F Fig. 2: Module label SL2 & SL2-F Com ponen

  • Solibro SL2, 9 InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2 Framed modules The listed mounting variants are valid for point mounting and linear mounting. * TestLoad=γ m x Design Load  γ m ≥1.5(observeregionalrequirements) Clamp area [x] Substructure lateral Point mounting  Cl amp area [x] Substructure longitudi- nal Linear mounting  Design load Permissible static load [Pa] Test load with safety factor γ m =1.5 [Pa]* 150 mm - 250 mm − 3,600 1,600 5,400 2,400 125 mm - 275 mm 150 mm - 275 mm 2,900 1,600 4,400 2,400 100 mm - 300 mm 100 mm - 325 mm

More Instructions:

DOWNLOAD

Related Products and Documents (Solar panel):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 SOMFY 5012941 Manual  somfy/5012941-T9Z.pdf 03 Jul 2022 2 4.15 Mb
2 Citronic MPCD-S6 Owner's manual citronic/mpcd-s6-CCQ.pdf 12 Feb 2023 12
3 Teltonika MVC300 Operation & user’s manual teltonika/mvc300-YT4.pdf 23 Feb 2024 14
4 Zelmer ZJP1300B Operation & user’s manual zelmer/zjp1300b-QGI.pdf 21 Mar 2023 63
5 StarTech.com SV431USBAE Instruction manual startech-com/sv431usbae-9IC.pdf 28 Dec 2023 9 0.18 Mb
6 Billion BiPAC 7100SV Quick start manual billion/bipac-7100sv-QPX.pdf 19 Feb 2024 14 0.52 Mb

Similar Resources:

  • Viessmann

    Vitosol-F

    (80 pages)
    Installation instructionsfor contractorsVIESMANNVitosol-FType SV and SHFlat-plate collector for pitched roofs, roof integrationVITOSOL-F5604 068 GB 4/2012Dispose after installation. …
  • Carbest

    825030

    (16 pages)
    SOLARKOFFERFOLDABLE SOLAR KIT825030DE – BENUTZERHANDBUCHUK – USER'S INSTRUCTIONU S B5 V / 1.2 A5 m CABLEINCL. 3 ADAPTER MONOCRYSTALLINEINCL. SOLAR CHARGECONTROLLER 120WAT TPOWERSIZE (mm)1010x 690x 30OPENSIZE (mm)CLOSED690 x 505 x 60 …
  • Carmanah

    E Series

    (75 pages)
    E / F Series TRAFFIC BEACON USER MANUAL Carmanah Technologies Corp. | 250 Bay St, Victoria, BC V9A 3K5, Canada | 1.250.380.0052 | [email protected] | carmanahtraffic.com For the R920-E/F, R820-E/F, R829-E/F, and R247-E/F flashing beacons 84323_MANUAL_TRA_E-F-Series_RevA …
  • PowerTech

    MP-4554

    (6 pages)
    45 WATT SOLAR KITINSTRUCTION MANUALMP-4554Distributed by:Electus Distribution Pty. Ltd.320 Victoria RoadRydalmere NSW 2116 AustraliaPhone: 1300 738 555 Facsimile: 1300 738 500www.electusdistribution.com.auMade in China …
  • REYNAERS

    BS 30 Solar

    (12 pages)
    Opening CSReynaers Tab's opening cs-eco sy1 1Reynaers Tab's opening cs-eco sy1 1 12-04-2007 11:33:4112-04-2007 11:33:41Edition 08/2010 (based on 089.L56A.00)BS 30 SolarBS 30 Solar …
  • Aleo

    X63

    (20 pages)
    Please read this carefully prior to installation. Store in a safe place for maintenance.Quick Reference Manual Rel. 4.7, 08+/2020, en-GB-DE (1)JD00000 10-ENwith frames for roof integration S83 sol, S81 solFor the aleo moduleswith standard frames 42mm X63, X83 X61, X83INSTALLATION MANUALwith standard frames 35mm P23 …

Comments, Questions and Opinions: