Manualios.com

3G TX-3G01 Operation & User’s Manual

3G TX-3G01 Manual Online:

3.25, 1456 votes
3G TX-3G01 User Manual
3G TX-3G01 User Guide
3G TX-3G01 Online Manual

Text of 3G TX-3G01 User Guide:

  • 3G TX-3G01, 3. How to control when you receive alarm calling 1) When alarm happens, the siren will hoot to warn neighbours, and the video alarm main panel will auto dial the preset 6 alarm phone numbers. If it is set visual phone call, when you answer the alarm calling, you can view the video around the video alarm system, you can hear alarm voice menu indication also. E.g "Emergency Alarm", press * to play function voice menu: Press “1” to listen in the alarm spot Press “2” to active the sire

  • 3G TX-3G01, press "9" for reverse video/image. press "7" for forward video/image. press "0" for voice menu replay. The main host will replay PTZ controlling voice menu again. press "*" for back on main voice menu directory. Please don't forget to press "#" for exiting phone operation&confirm the alarm! If you hang up the phone without pressing "#", the main host won't stop alarming. It will dial next group alarm phone number by turn, or re-dial the alarm phone number. It will stop dialing for alarm until up to totally 15 times. 3. How to control when remotely dia

  • 3 rd step: Prepare 1pcs W-CDMA SIM card which can be dialed out(pre-charge), insert it into "SIM Card" slot parallelly. If it needs to connect siren, please plug it into "Siren" slot, if it need recording, please insert TF Flash card into "TF-Flash" slot, then plug the adapter into "Power" slot, the main host will make one sou

  • 3G TX-3G01, 4) Set MMS phone numbers: The 3G system will send MMS with pictures to the pre-setting MMS phone number when alarm happen. You can input the MMS phone number as above interface show you. After setting, please click to save all the settings. 4.6 Click to program wireless sensors: This 3G alarm system can match 32pcs alarm accessories totally (PIR-Door sensor-water detector-gas detector-smoke detector-heat detector,etc.) and up to 5pcs remote controllers. As above interface shows you, when you program new sensors into 3G system, you should do it like this: choose Acc

  • Central Panel, which can receive signal, recognize, and record and output alarm functions etc. Siren: It has 120Db output when the system is triggered. Intelligent curtain PIR Motion sensor detects the movement from human beings USB data cable: Function setting Door sensor: One transmitter and one magnetic part, if the distance is over 1.5cm between these two part

  • 3G TX-3G01, When main panel is in standby status, input “#9* 2 (1/0) # ” on the wireless keypad, main panel will BEEP when you press every key. Two BEEP indicate this function setting ok. Note: 1) #9* 2 1 # Turn ON the Remote control opration audio 2) #9* 2 0 # Turn OFF the Remote control opration audio 3) Then when you press any key on the remote control, the mini siren will sound at the same time. 6. Password changing setting When main panel is in standby status, input “#7*new password+new password+#” on the wireless keypad, main panel will BEEP when you press every key. Two BEEP indicate new password changing ok. For example, if you

  • 3G TX-3G01, control, the wired mini siren will make sound "Du...". E.g by default setting ( It means siren accompany sound with ON.) 9) Arm/Disarm SMS report function ON/OFF: if it’s ON, whether you arm or disarm the host with remote control, the host will send you SMS notification. E.g by default setting 10) Use the remote password or not: if you choose password protection,you should input correct password to check the real time video and remote control the system when you dial in to it. Without password protection when dial in, it will affect the privacy for the

  • 3G TX-3G01, 2. Standard Package: 3G video alarm 1pcs(including camera bracket 1set), remote controller 2pcs, door sensor 1pcs, PIR motion sensor 1pcs, wireless keypad 1pcs, mini siren 1pcs, external speaker 1pcs, USB data cable 1pcs, power adapter 1pcs. NOTE: 1. This device should installed at a dry and ventilated place, should get rid of direct sunshine, high temperature and strong magnetic field interfere place. 2. Please don’t clean the device with corrosive toluol liquid. 25

  • 3G TX-3G01, 4.10 Click to control home appliance control switch: (optional) This 3G alarm system can remotely control by phone for up to 9CH single trigger,9CH double trigger, totally 18CH wireless home appliance plug or switch,showing as below: 4.11 Upgrade: When our company has new software/program,our distributor can use for upgrading file to make the system working better, users do not have the authority to upgrade by themselves. Chapter Five: Function Setting and Program via Keypad Note: Original 4 digits password for all the settings: 1234 1. Coding wireless keypad Wireless keypad need to match/code with 3G alarm system before using,operate like this: Press "RESET" button

  • 3G TX-3G01, 5. Wireless keypad and remote control don’t work any more? A. Low voltage B. Battery shrapnel loosen or rust C. Not coding to the main panel Solution: Change battery, code to the main panel, contact your local distributor to purchase new ones 6. Siren not work? A. Siren pin and jack short circuit or break off B. Bad connection between pin and jack C. Pin cable open circuit D. Mute alarm setting Solution: Change or repair siren pins or pins cable, set sound alarm Chapter Eight: Technical Parameters 1. Technical Parameters: Power: DC12V 2A Working current(max.): ≤600MA Working static current: <30mA(1

  • 16. Formatting TF card Input "#9*67 + password+ #" on wireless keypad, main panel will BEEP when setting is over. Two BEEP indicate operation successful. After operating this command, the main panel will delete all the file in TF card. 17. How to set disarm indication tone of door sensor Start disarm indication tone of door sensor, Input: “ #9*17+# ”

  • 3G TX-3G01, (Figure 1: back side connection) (Figure 2: 3G main host structure) 1:Power slot 2:GSM/3G Network indication LED 3: System state indication LED 4: USB PC setup connector 5: RF antenna connector 6:External speaker 7: external siren 8:T-FLASH card slot 9: USIM card slot 10:Power adapter 11:Connector of Extension Cable 12: Power plug 13: RF antenna 14: Photoresistor sensor 15:Camera lens 16:IR night vision light 17: MIC hole 1 st Step: Open the package to check if it is completely and good.(Including main host,power adapter, keypad, remote controller, wireless sensors & other accessories.) 2 nd step: Confirm installation position and prepare for

  • 3G TX-3G01, If user name and password are in blank, so it don't need to fill in. Only send: password+APN+"APN" E.g China mobile APN is CMWAP, user name: in blank, password: in blank Sending SMS to 3G alarm main host: 1234APNCMWAP After setting successful, it will feedback SMS: Access Point Name Setting successfully E.g APN is WAP, user name: ABC, password: 123 Sending SMS: 1234APNWAP,ABC,123 2) Setting MMS centre address(MMSC URL) Sending SMS to 3G main host: password+URL+"MMSC url" E.g China mobile MMSC URL is http://mmsc.monternet.com Sending SMS to 3G main host: 1234URLhttp://mmsc.monternet.

  • 3G TX-3G01, E.g Setting 1 st group timing arm/disarm: Every day to arm from 9:00 and disarm until 17:30. Showing as below: Press to save setting. E.g Setting 2 nd group timing arm/disarm: Monday to arm from 9:00 and disarm until 18:00. Showing as below: Press to save setting. 2)Checking Timed Arm/Disarm infomation, showing as below: 14

  • 3G TX-3G01, 3) You can delete single remote controls or wireless sensors you have programmed showing as below: 4) You can delete all remotes you have programmed showing as below: 5) You can delete all sensors you have programmed showing as below: 6) Setting wireless siren's ID: The main host can work with our company's wireless middle/big size wireless siren, check the 8 digits ID code in the back of the wireless siren, input it as here,e.g: Click "Press To Set" is OK. If you would like to close the wireless siren, please input the ID code as 00000000. 4.7 Click to c

  • 3G TX-3G01, most inside, then release is ok. Pop up: Use finger to press SIM card or T-Flash card, then release, to get the card out of the system. 2. How to install Door/Window Sensor (Fig 3) A. Door sensor is consisted of two parts: transmitter part and magnetic part .You can fix them with screws or adhesive.You need to check the LED side of transmitter part against the magnetic part . The maximum limit is 15mm between them. B. If you use the configured adhesive to install the door/window sensor, please make sure the installation position flat and clean. If you install it on the wooden material, please install with setscrews. C. If t

  • 3G TX-3G01, Chapter Four: Function Setting and Program via USB NOTE: The PC setting software CD is included in the 3G standard package, you can copy all the files into your PC and then set up this software and set all the 3G system functions on PC easily! 4.1 Power on the 3G camera with power adapter, connect the camera to your PC with USB cable included! 4.2 Double click to set up "System USB driver.exe" and these two software. 4.3 Click this software on PC desktop, press button " ", it will show the following interface " ", the main host's default password:"1234", input

  • 1) Zone number: Can be set as 00~99 zone numbers 2) Sensors’ name code: "1" - Remote control, "2" - PIR, "3"- Door sensor, "4" - Smoke detector, "5" - Gas detector, "6" - IR beams, "7" - Water sensor, "8" - Heat detector. "9" -- glass breaking sensor, "

  • 3G TX-3G01, C. Alarm SMS number setting This system support 3 SMS alarm phone numbers. When main panel is in standby status, input “#0*0(1 ~ 6 )*phone number# ” on the wireless keypad, main panel will BEEP when you press every key. Two BEEP indicate alarm SMS number setting ok.(1~6 means No.1 to No.6 alarm SMS number.) For example, if your phone number is 13800138000 and you want to set it to be the NO.1 alarm D number, you can input “#0*01+13800138000#” D. Alarm MMS number setting This system support 3 MMS alarm phone number

  • 3G TX-3G01, Here, you can set the following functions: 1) Siren’s hooting time: siren’s hooting time is programmable when 3G system alarming(00-30 minutes) If you set 00, it will be mute alarm; If you set over 30 minutes, the alarm system won’t stop hooting until you disarm the system. E.g. by default setting 2) Arm delay time setting: Exit delay time setting: 00-99 seconds E.g. by default setting 3) Alarm delay time setting: Entry delay time setting: 00-99 seconds E.g. by default setting

  • 3G TX-3G01, Chapter One: Brief Instruction Thank you for choosing our high-tech 3G Video Alarm system to secure your family and property. Please read this manual carefully before you set up this system. This system integrate advanced microcomputer technology and IC design. Lovely and luxury appearance, latest technology, high quality and reliable performance will make it the most amazing device on the market. Special features: Visual phone function, you can view the live video at any time any where. 1, This product use the most popular world wide network W-CDMA. 2, If the place has 3G signal, the image is clear and smooth, If there is no 3G signal, the system will automati

  • 3G TX-3G01, 4.5 Click to set the following alarm phone numbers: Here, you can set the following alarm phone numbers: This 3G system support 6 groups of alarm phone numbers including audio phone number or audio & video phone number, 3 groups SMS notification numbers and 3 groups MMS phone numbers. Before setting, please Click to obtain the phone number which already set. Then you can modify each group as below operation: 1) Set alarm audio numbers, you can input phone number directly as above interface shows you: 13800138000. When system alarming, it will auto dial ordinary audio cal

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 TRENDnet TK-205i Quick installation manual trendnet/tk-205i-DTR.pdf 17 Oct 2022 10 0.27 Mb
2 Lennox Hearth Products VIS25 Installation and operation manual lennox-hearth-products/vis25-54D.pdf 30 Jun 2023 30
3 Mackie SRM350v3 Brochure & specs mackie/srm350v3-IWG.pdf 05 Jan 2023 9
4 Mackie SRM350 V2 Operation & user’s manual mackie/srm350-v2-CBW.pdf 29 Nov 2022 20
5 WELLTECH LAN PHONE 101 H.323 - VERSION 112 & 502 Manual  welltech/lan-phone-101-h-323-version-112-502-Y85.pdf 16 Sep 2023 34 1 Mb
6 Generac Power Systems Liquid Cooled Gas Engine Generator Sets None Specification sheet generac-power-systems/liquid-cooled-gas-engine-generator-sets-none-18B.pdf 15 May 2023 4 0.44 Mb

Similar Resources:

  • Marmitek

    TV Anywhere 5.8GHz

    (108 pages)
    TV ANYWHERE™ 2.4/5.8GHzWireless Audio/Video Systemwith built-in tuner20292/20090202 • TV ANYWHERE™ Wireless Audio/Video SystemALL RIGHTS RESERVED MARMITEK ©USER MANUAL 3GEBRAUCHSANLEITUNG 19GUIDE UTILISATEUR 37MODO DE EMPLEO 55MANUALE D’ISTRUZIONE 71GEBRUIKSAANWIJZING 87TV ANYWHERE™ 2.4/5.8GHzWireless Audio/Video Systemwith built-in tuner …
  • Poolguard

    DAPT-WT

    (2 pages)
    RE V. 02-17www.poolguard.comCONNECTING DOOR ALARM TO SENSOR SWITCHESREAD THE DOOR ALARM MANUAL FOR INSTALLATION ON ONE DOOR FIRST:THE SENSOR WIRES ARE PERMANENTLY CONNECTED TO THE DOORALARM. CONNECT BOTH SENSOR WIRES COMING FROM THE DOOR ALARMTO THE SENSOR SWITCH ON THE DOOR FRAME. THEN USE THE SUPPLIEDJUMPER WIRES TO CONNECT TO THE SCREEN D …
  • Lince

    1805SMART/E

    (8 pages)
    ITENSIRENA LED VIA FILO AUTOALIMENTATA DA ESTERNOManuale di installazione, uso e manutenzioneInstallation, operation and maintenance manualWIRED SELF POWERED OUTDOOR LED SIREN ART. / ITEM: 1805SMART/E1865SMART/LMADE IN ITALYLa dichiarazione CE del presente articolo è reperibile sul sito www.lince.net.The CE declaration of this item is available on www.lince …
  • Lifebuoy

    BCone

    (11 pages)
    BCONEInstallation & Operation GuideMake Your Pool SaferRev B | Doc P/N: BC-00-70-002Copyright © 2021-2022 Lifebuoy, all rights reserved.85dB Alarm at 10 Feet …
  • Alarm Lock

    Trilogy PDL3500

    (2 pages)
    ALARM LOCK 345 Bayview Avenue, Amityville, New York, U.S.A. 11701 For Sales and Repairs 1-800-ALA-LOCK • For Technical Service 1-800-645-9440 Fax: 631-789-3383 • [email protected] Note: Technical Service is for security professionals only ALARM LOCK Tech Support TECH TIP Date: Thursday, July 10, 2014 Subject: Securing an unlocked Trilogy …
  • Siemens

    SINAMICS S120

    (40 pages)
    Control of a SINAMICS S120 with an Allen-Bradley controller (Compact/ControlLogix) via EtherNet/IP https://support.industry.siemens.com/cs/ww/en/view/92045369 Siemens Industry Online Support …

Comments, Questions and Opinions: