Manualios.com

3One data IES608-2F Hardware Installation Manual

3One data IES608-2F Manual Online:

3.55, 2261 votes
3One data IES608-2F User Manual
3One data IES608-2F User Guide
3One data IES608-2F Online Manual

Text of 3One data IES608-2F User Guide:

  • 3One data IES608-2F, YourSerialandDataCommunicationsExpert Shenzhen3onedataTechnologyCo.,Ltd IES608-2F 8-port 8-port 8-port 8-port10/100M 10/100M 10/100M 10/100MIndustrial Industrial Industrial IndustrialEthernet Ethernet Ethernet EthernetSwitch Switch Switch Switch Hardware Hardware Hardware Installation Installation Installation Guide Guide Guide I I I Introduction ntroduction ntroduction ntroduction: : : : IES608-2Fseriesareatypeofplug-and-playindustrialmanaged redundantEthernetswitch,whichsupports6-port10/100Base-T(x) and2-port100Base-Fx.The7and8ports(100Base-Fx)areusedto establishSW-Ringforthepurposeaccomplishingredundancyf

  • YourSerialandDataCommunicationsExpert Shenzhen3onedataTechnologyCo.,Ltd Advanced Advanced Advanced AdvancedIndustrial Industrial Industrial IndustrialEthernet Ethernet Ethernet EthernetNetworking Networking Networking NetworkingCapability Capability Capability Capability 1.Storeandforward.8kaddress.SupportMACaddressfiltrate struction 2.SW-Ring(recoverytime<20msatfullload) 3.Port-ba

  • 3One data IES608-2F, YourSerialandDataCommunicationsExpert Shenzhen3onedataTechnologyCo.,Ltd 1.Groundingscrew 2.PWR1/PWR2input,relayoutput 6bitterminalblock 3.DIPswitch:DOWNLOADPROGRAM, RESUMEDEFAULT,SW-RingEnabled 4.DOWNLOADPROGRAMport (RS-232,RJ45) 5.Heatdissipationorifices 6.DIN-Raillocatingkittop top top toppanel panel panel panel 7.Screwholeforwallmountingkit 8.10/100Base-T(X)port 9.Corporation,productinformation 10.RunindicationLED 11.PowerinputPWR1LED 12.PowerinputPWR2LED 13.SystemalarmindicationLED 14.Fiberport8indicationLED 15.Fiberport7indicationLED 16.100Base-FXport back back back backpanel panel panel panel Units Units Unit

  • 3One data IES608-2F, YourSerialandDataCommunicationsExpert Shenzhen3onedataTechnologyCo.,Ltd Communication Communication Communication Communicationconnector connector connector connector: : : : IES608-2Fserieshave8x 10/100BaseT(X)Ethernetports(RJ45)and 2x 100BaseFX(SC/STconnector,optional)fiberports. 10/100BaseT(X) 10/100BaseT(X) 10/100BaseT(X) 10/100BaseT(X)Ethernet Ethernet Ethernet Ethernetport port port port ThepinoutofRJ45portdisplayasbelow,connectbyUTPor STP. Theconnectdistanceisnomorethan100m.100Mbpsisused 100 Ω ofUTP5,10Mbpsisused100 Ω ofUTP3,4,5. RJ45portsupportautomaticMDI/MDI-Xoperation.can connecttheP

  • 3One data IES608-2F, YourSerialandDataCommunicationsExpert Shenzhen3onedataTechnologyCo.,Ltd MDI-X MDI-X MDI-X MDI-X( ( ( (Cross Cross Cross Crossover over over overcable cable cable cable) ) ) ) 100BaseFX 100BaseFX 100BaseFX 100BaseFXport port port port 100Base-FXfull-duplexSMorMMport,SC/STtype.Thefiber portmustbeusedinpair,TX(transmit)portconnectremote switch ’ sRX(receive)port;RX(receive)portconnectremote switch ’ sTX(transmit)port. Theopticalfiberconnectionsupportsthelinetoinstructenhance thereliabilityofnetworkeffectively. Suppose Suppose Suppose Suppose:Ifyoumakeyourowncable,wesuggestlabelingthetwo sidesofthesamelinewiththesameletter(A-to-AandB-t

  • YourSerialandDataCommunicationsExpert Shenzhen3onedataTechnologyCo.,Ltd LED LED LED LEDIndicator Indicator Indicator Indicator: : : : LEDindictorlightonthefrontpanelofIES608-2FSeries.the functionofeachLEDisdescribedinthetableasbelow. System System System Systemindication indication indication indicationLED LED LED LED LED LED LED LEDState State State StateDescription Description Descriptio

  • 3One data IES608-2F, YourSerialandDataCommunicationsExpert Shenzhen3onedataTechnologyCo.,Ltd Relay Relay Relay Relaycontact contact contact contact: : : : Therelayconsistsofthetwomiddlecontactsoftheterminalblock onIES608-2Fseriestoppanel.Thetwoterminalblockconnectorare usedtodetectbothpowerfaultsandportfaults.Thetwowires attachedtotheFaultcontactsformanopencircuitwhen: (1)IES608-2FserieshavelostpowerfromoneoftheDCpower inputs,or(2)OneoftheportsforwhichthecorrespondingPort alarmDIPSwitchissettoONisnotproperlyconnected. Ifneitherofthesetwoconditionsoccur,thealarmcircuitwillbe closed. Power Power Power PowerInput Input Input Inpu

  • 3One data IES608-2F, YourSerialandDataCommunicationsExpert Shenzhen3onedataTechnologyCo.,Ltd Switch Switch Switch SwitchSettings: Settings: Settings: Settings: Provide4bitswitchforfunctionsetting(ONisenable):1(ISP)is DOWNLOADPROGRAM,2isRESUMEDEFAULT,3isSW-Ring Enabled,4isblank(NC).Whentheswitchissetup,mustberestart. DOWNLOAD DOWNLOAD DOWNLOAD DOWNLOADPROGRAM PROGRAM PROGRAM PROGRAMport port port port: : : : IES608-2FseriesprovideoneDOWNLOADPROGRAMport (RJ45type),onthetoppanel,managethesystemwithPCby RJ45-DB9Fadapter. Installation Installation Installation Installation: Bef

  • 3One data IES608-2F, YourSerialandDataCommunicationsExpert Shenzhen3onedataTechnologyCo.,Ltd seriesadopt35mmDIN-Railinstallation,theinstallationstepsas fellows: 1.ExaminetheDIN-Railattachment 2.ExamineDINRailwhetherbefirmandthepositionbe suitabilityornot. 3.InsertthetopoftheDIN-Railintotheslotjustbelowthestiff metalspring. 4.TheDIN-Railattachmentunitwillsnapintoplaceasshown below. Wiring Wiring Wiring WiringRequirements Requirements Requirements Requirements Besuretodisconnectthepowercordbeforeinstallingand/orwiring yourEthernetSwitch. Calculatethemaximumpossiblecurrentineachpowerwireand commonwire

  • 3One data IES608-2F, YourSerialandDataCommunicationsExpert Shenzhen3onedataTechnologyCo.,Ltd thumbisthatwiringthatsharessimilarelectricalcharacteristics canbebundledtogether. 4.Keepinputandoutputwiringseparated.Itisstronglyadvised thatyoulabelwiringtoalldevicesinthesystemwhennecessary. Specifications: Specifications: Specifications: Specifications: Interface Interface Interface Interface RJ45Ports:10/100BaseT(X)autoconnection,Full/Halfduplexor forceworkmode,andsupportMDI/MDI-Xconnection FiberPorts:100BaseFXports(SC/STconnector,optional) Single-mode:20,40,60,80,120Km,optional Multi-mode:2,5Km,optional Wavelength:850nm,1310nm,1550nm DOWNLOADPRO

  • 3One data IES608-2F, YourSerialandDataCommunicationsExpert Shenzhen3onedataTechnologyCo.,Ltd Supportdualpoweralarminput Mechanical Mechanical Mechanical Mechanical Dimensions:136mm × 52mm × 105mm(H × W × D) Casing:IP30protection,metalcase Installation:DIN-Rail,WallMounting Weight:800g Environmental Environmental Environmental Environmental OperatingTemperature:-40to70°C StorageTemperature:-45°Cto85°C AmbientRelativeHumidity:10to95%(non-condensing) Approvals Approvals Approvals Approvals Warranty: Warranty: Warranty: Warranty:5 5 5 5years years yea

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 ActionTec MWTV200KIT Notice actiontec/mwtv200kit-4N5.pdf 25 Apr 2023 2 0.31 Mb
2 KUSSMAUL 091-51 Instruction manual kussmaul/091-51-C4R.pdf 02 Jan 2023 6
3 Panasonic HDC-TM700 Operation & user’s manual panasonic/hdc-tm700-QBB.pdf 27 Sep 2022 12
4 Monoprice 4x2 HDMI Operation & user’s manual monoprice/4x2-hdmi-9QH.pdf 06 Sep 2023 2
5 Toro 38430 Operator's manual toro/38430-13N.pdf 09 Oct 2023 28
6 Ledj STAGE WASH U.V. 36 LEDJ106 Operation & user’s manual ledj/stage-wash-uv-36-ledj106-81D.pdf 23 Feb 2023 9

Similar Resources:

  • D-Link

    DI-604UP

    (16 pages)
    1. If you purchased this router to share your high-speed Internet connection with other computers, you must have either an Ethernet-based Cable or a DSL modem with an established Internet account from an Internet Service Provider (ISP). 2. It’s best to use the same computer that is connected to your modem for configuring the DI-604UP router. …
  • Allied Telesis

    AT-9408LC/SP

    (102 pages)
    613-000357 Rev. BAT-9400 Series Layer 2+ Gigabit Ethernet SwitchesAT-9408LC/SPAT-9424T/GBAT-9424T/SPAT-9424TsAT-9424Ts/XPAT-9448TsAT-9448T/SPAT-9448Ts/XP◆Installation Guide …
  • Tripp Lite

    NPOEI-60W-1G

    (48 pages)
    1Industrial Gigabit Ethernet PoE Injectors, PoE++, 802.3btModels: NPOEI-60W-1G, NPOEI-90W-1G1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/supportCopyright © 2021 Tripp Lite. All rights reserved. Quick Start GuideWARRANTY REGISTRATIONRegister your product today and be automatically entered to win an ISOBAR® surge protector in our monthly dr …
  • Pakedge Device & Software

    X-Series

    (20 pages)
    X-Series SwitchesS24av/S24P8av/S24P16av/S24Pav/S24Hav/S8Hav/S24f/S24HfQuick Start Guide – Version 1.1Enterpr-Cl, Full Manage Gigabi Switch wit Rear or Fron Facin Port S24f/S24HfS24av/S24P8av/S24P16av/S24Pav/S24Hav/S8Hav …
  • Cisco

    805

    (8 pages)
    Cisco Systems, Inc.All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.Page 1 of 8Data SheetCisco 805 Series Serial RouterThe Cisco 805 Serial Routeroffers enhanced networksecurityandreliabilitythroughthe power of Cisco IOS® Software technology tailored for small offices.Figure 1The Cis …
  • Cisco

    1100-8P

    (64 pages)
    Hardware Installation Guide for the Cisco 1000 Series IntegratedServices RouterLast Modified: 2018-09-11Americas HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706USAhttp://www.cisco.comTel: 408 526-4000800 553-NETS (6387)Fax: 408 527-0883 …

Comments, Questions and Opinions: