  • ADC Kentrox 78220, Switch S2 — 56 Kbit/s/Channel Data Port Bit Rate Settings Number of Channels Data Rate (Kbit/s) 123456 24 1344 Down Down Down Down Down Down 1 x 56 56 Down Up Down Down Down Down 2 x 56 112 Down Down Up Down Down Down 3 x 56 168 Down Up Up Down Down Down 4 x 56 224 Down Down Down Up Down Down 5 x 56 280 Down Up Down Up Down Down 6 x 56 336 Down Down Up Up Down Down 7 x 56 392 Down Up Up Up Down Down 8 x 56 448 Down Down Down Down Up Down 9 x 56 504 Down Up Down Down Up Down 10 x 56 560 Down Down Up Down Up Down 11 x 56 616 Down Up Up Down Up Down 12 x 56 672 Down Down Down Up Up Down 13 x 56 728 Down Up Down Up Up Down 14 x 56 784 Down D

  • ADC Kentrox 78220, Equipment Attachment Limitations CP-01 1.10.1 “NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The department does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. T

  • Configuration Work Sheet Default values are highlighted in Bold Italics . Data Port Configuration Function Switch Options Selection Rate per Channel S2 56 Kbit/s or 64 Kbit/s Channel Mapping S2 # of Channels x Rate =Frequency ( 1344) Starting Channel S4 1 ,2,3,4,6,8,12or16 Channel Sequence S4 Alternating or Contiguous Data Inversion S5 On or Off DP Clock Source S5 Internal or External DP Clock I

  • Self Test At power-up, the D-SERV DSU/CSU runs a complete self test routine that checks all the data paths, I/O ports, read/write memory, and the program checksum. At the end of the self test the LEDs will flash in sequence. If the POWER/FAIL LED lights red after self test, this indicates a failed test by the equipment or the power supply. If the POWER/FAIL LED lights green after self test,

  • Jumper Location and Access The configuration jumpers are located on the D-SERV card. Plug-in units have the jumpers readily accessible. To access the jumpers on a stand-alone unit: ¤ Disconnect all power connections and interface cables ¤ Turn the D-SERV unit over, and using a phillips screwdriver remove the four screws connecting the two sides of the case (see Figu

  • ADC Kentrox 78220, Site Selection Use the following guidelines in selecting a site: ¤ (110 VAC only) The installation site should include a grounded 110 VAC power receptacle. ¤ The standard specifications for the following cable distances as prescribed by the standards documents are: Interface Suggested Maximum Cable Length V.35 50 FEET EIA-530 200 FEET NOTE: At lower than maximum speed with proper cabling, longer distances can be achieved. For more information please refer to the application note on cabling available from your Kentrox representative. ¤ The site should p

  • ADC Kentrox 78220, 3 INSTALLATION Installation Check List Installing D-SERV Stand-Alone Units ¤ Read Operator Manual thoroughly ¤ Select Site for installation ¤ Configure unit with the DIP switches ¤ Complete mechanical installation/mounting ¤ Connect power and ground (-24 to -48 VDC and 110 VAC operation) ¤ Connect Alarm Relay (DC units only) ¤ Connect interface cables Installing D-SERV Plug-In Units ¤ Read Operator Manual thoroughly ¤ Select Site for installation ¤ Install 12 slot High Density Mounting Chassis ¤ Install enough back panels in the chassis to service the D-SERV Plug-Ins

  • ADC Kentrox 78220, R RCNLR command, 41 RCNSR command, 41 RED ALARM LED, 36 Remote Loop Back Codes, 3 Remote Loop Backs, 3, 41 RJ48C pin assignments, 34 RS-449 pin assignments, 31 RTS LED, 36 RUNLR command, 41 RUNSR command, 41 RxD LED, 36 S Self Test, 30 Shelf and Mounting accessories, 25 Site Selection, 26 Specifications, 3 Starting DS0 Channel configuration, 10 Switch positions, 6 T Tail Circuit Timing, 17, 24, 32 TxD LED, 36 V V.35 connection, 26, 31 V.35 pin assignments, 31 Y YELLOW ALARM LED, 36 Operator's Manu

  • ADC Kentrox 78220, Line Build Out (LBO) Switches The setting for Line Build Out (LBO) to the network is determined by the carrier and is based on the line distance to the nearest T1 repeater. The different LBO settings allow the user to adjust the attenuation of the signal transmitted out the network port of the D-SERV DSU/CSU. The default setting is 0.0 dB. Your T1 service provider will be able to tell you if a non-default setting is required in your application. WARNING: Improper setting of the LBO switches may cause interference with other telephone company ser

  • ADC Kentrox 78220, Switch S3 — Network Interface Clock Source The D-SERV DSU/CSU can derive the Network Interface 1.544 MHz clock in one of three ways. LOOP derives the clock from the network input. INT derives the clock from a crystal internal to the D-SERV DSU/CSU. DP derives the 1.544 MHz clock from the data port (tail circuit timing application). When the data port is configured as the clock source (tail circuit timing) the data port input clock rate must match the data port bit rate set with the DIP switches on S2. Selecting DP clo

  • ADC Kentrox 78220, E EIA-530 connection, 26, 31 EIA-530 pin assignments, 31 I Idle Channels, 10 Installation Check List, 23 J Jumper Configuration options, 21 Jumper location, 20 - 21 L LBO Switches location, 19 Leg removal, 5 Line Build Out, 19 Line Loop Back, 38 LLB, 38 Loop Back switch, 38 M Model numbers, 1 Mounting, 27 N Network Interface Clock Source configuration, 17 Network Interface configuration, 16 Network Interface connection, 34 Network Port pin assignments, 34 P PLB, 41 POWER LED, 36 Operator's Manu

  • ADC Kentrox 78220, Electrical Installation CAUTION: Always disconnect all telephone lines before servicing or disassembling this equipment. The power connection with frame ground should be the first electrical connection connected when installing D-SERV units, and the last electrical connection disconnected when removing D-SERV units. Stand-Alone AC Power Connection Plug the power cord on the D-SERV unit into a grounded 115 VAC power receptacle. As soon as power is applied to the D-SERV DSU/CSU the unit will commence self test. Stand-Alone DC Power Connections Use a power supply capable of providing a voltage

  • ADC Kentrox 78220, Features The D-SERV DSU/CSU is available with the following features: ¤ DIP switch selectable configuration ¤ Choice of V.35 Data Port or EIA-530 Data Port ¤ Choice of an internal -24 to -48 VDC or 110 VAC power supply ¤ Normally Open or Normally Closed Alarm Relay contacts (DC versions only) ¤ Diagnostics through front panel switch controlled loop backs ¤ Remote report and alarm retrieval from a DataSMART unit ¤ Remote diagnostics capability from a DataSMART unit ¤ Data Port Timing ¤ Front Panel Status and Alarm LEDs ¤ RJ48C Network interface conne

  • ADC Kentrox 78220, REGULATORY INFORMATION ADC Kentrox D-SERV units have been tested by a Nationally Recognized Testing Laboratory (NRTL) and are in compliance with Underwriters Laboratories (UL) standard 1459, Edition 2. FCC PART 15 REQUIREMENTS This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, m

  • ADC Kentrox 78220, Canadian DOC Requirements This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the Radio Interference Regulations of Canada. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques Classe A prescrite dans le règlement sur le brouillage Radioélectrique Édicté par Communications du Canada. Operator's Manual viii

  • ADC Kentrox 78220, Switch S4 — Alternating and Contiguous Channels The D-SERV DSU/CSU can be configured to activate channels sequentially (contiguous) or configured to activate every other channel (alternating). For example, if four channels have been activated and the starting channel is channel 16, contiguous configuration will activate channels 16, 17, 18, and 19. Alternating configuration will activate channels 16, 18, 20, and 22. Alternating channels is useful to preserve T1 pulse density if large amounts of zeros are to be transmitted as data. Switch S4-4 selects the alternating or contiguous channel option. NOTE: It is not allowed to activate more channels than can be accommodated between the start

  • Network Port Grounding Lug 1 8 Figure 21. Network Port Location (AC Powered Units) Network Port Grounding Lug 8 1 Figure 22. Network Port Location (DC Powered Units) Figure 23. RJ48C Pin Designation Operator's Manual 35

  • ADC Kentrox 78220, FCC PART 68 REQUIREMENTS This equipment complies with Part 68 of the FCC rules. On the bottom of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. Upon request of the telephone company, you should provide the FCC registration number and the ringer equivalence number (REN) of the equipment which is connected to your line. The D-SERV DSU/CSUs registration number is F8IUSA-74432-DE-N and the REN is 0.0B. The D-SERV DSU/CSU operates with a 1.544 Mbit/s/s digital channel using an RJ48C

  • ADC Kentrox 78220, Switch S5 — Data Inversion and Data Port Clock Source Function 1 2 3 Data Inversion OFF Down Data Inversion ON Up Internal DP Clock Source Down External DP Clock Source Up DP Clock Inversion OFF Down DP Clock Inversion ON Up Figure 8. S5 Location Operator's Manual 15

  • ADC Kentrox 78220, Figure 16. Tail Circuit Timing (TCT) Application . . . 32 Figure 17. Cable #95010055 Pin Outs .......... 32 Figure 18. Cable #95010056 Pin Outs .......... 33 Figure 19. Cable #95010057 Pin Outs .......... 33 Figure 20. Cable #95010058 Pin Outs .......... 33 Figure 21. Network Port Location (AC Powered Units) 35 Figure 22. Network Port Location (DC Powered Units) 35 Figure23.RJ48CPinDesignation............ 35 Figure24.D-SERVFrontPanel ............. 37 Figure25.LineLoopBack(LLB) ............ 38 Figure26.DataPortLoopBack(DPLB) ....

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Lexmark C752 Quick reference lexmark/c752-511.pdf 17 Jan 2024 2
2 Electrolux 316488522 Installation, use & care manual frigidaire/316488522-R5T.pdf 23 Oct 2022 21 2.01 Mb
3 Samsung HW-J450 Operation & user’s manual samsung/hw-j450-53U.pdf 11 Feb 2023 27
4 Celestron Firstscope 80 AZ Instruction manual celestron/firstscope-80-az-RHK.pdf 26 Dec 2022 17 1.61 Mb
5 GE VGN550 Operation & user’s manual ge/vgn550-L62.pdf 14 Nov 2023 44 1.45 Mb
6 Yamaha BWS CW50 Owner's manual yamaha/bws-cw50-R99.pdf 02 Nov 2022 68 2.6 Mb

Similar Resources:

  • Leviton

    47611-GT4

    (4 pages)
    110/100 Mbps Four-Port InternetGatewayThe 10/100Mbps Four-Port Internet Gateway is an easy-to-use router that offers smalloffice and home office (SOHO) an economical way to connect an entire local area network(LAN) to the Internet using an external DSL/Cable Modem.Follow this Quick-Start Guide to mount the Gateway into your Structured Media™ Center(SMC), a …
  • ATTO Technology

    1550

    (1 pages)
    iPBridge Products Product Features 3600 2700 2600 1550 Number of iSCSI Ports 4 4 4 1 Number of SCSI Ports 8 SAS Lanes n/a 2 1 SCSI Interface n/a n/a LVD/SE LVD Number of FC Ports 2 2 n/a n/a FC Interface n/a SFP n/a n/a FC Speed n/a 4-Gigabit n/a n/a Ethernet Interface Gigabit Ethernet Gigabit Ethernet Gigabit Ethernet Gigabit Ethernet Data Tra …
  • Zte

    ZXR10 T8000

    (61 pages)
    ZXR10T8000Carrier-ClassRouterHardwareInstallationGuide(Cluster)Version:1.00.10ZTECORPORATIONNO.55,Hi-techRoadSouth,ShenZhen,P .R.ChinaPostcode:518057Tel:+86-755-26771900Fax:+86-755-26770801URL:http://ensupport.zte.com.cnE-mail:[email protected]
  • Festool

    OF 2200 EB

    (38 pages)
    701178_003Instruction manualPage 6IMPORTANT: Read and understand all instructions before using.Guide d’utilisationPage 15IMPORTANT: Lire et comprendre toutes les instructions avant de démarrer les travaux.Manual de instruccionesPagina 25IMPORTANTE: Lea y comprende todas las instrucciones antes de usar.Instruction manual Guide d’utilisation Manual de ins …
  • NETGEAR

    FVS328 - ProSafe VPN Firewall

    (2 pages)
    FVS328ProSafe VPN Firewall with Dial Back-up SurefireBusiness-ClassSecureThoroughlyProtectedEasy to UseFlexible &DurableDesktop PCs with FA311 network card installedDesktop PCs with FA311 network card installedServers100 Mbps10 MbpsFVS328 VPN Firewall FVS328 VPN FirewallCable/DSLmodemTelecommuterwith ProSafe VPNClient softwareTelecommuterwith ProSafe VPN …
  • SmartBridges

    sB3412

    (78 pages)
    Copyright © smartBridges Pte Ltd. All Rights Reserved. u n w i r i n g o u r w o r l d T M airClient™ Nexus PRO TOTAL sB3412 User Guide Version 1.0 …

Comments, Questions and Opinions: