Manualios.com

Aertesi SOFFIO Technical Manual

Aertesi SOFFIO Manual Online:

3.5, 1953 votes
Aertesi SOFFIO User Manual
Aertesi SOFFIO User Guide
Aertesi SOFFIO Online Manual

Text of Aertesi SOFFIO User Guide:

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 6 AER.MT.GB.SOF.001.05.15 4-TECHNICAL SPECS STRUCTURE: made of galvanized steel, thickness 1.00 ÷ 1, 50 mm. The sturdy structure prevents vibrations and includes the mounting brackets to the ceiling. On request, it can be painted. ACCESSIBILITY: the filter can be removed both from the bottom and the sides, without the aid of tools (if some accessories are installed on the suction side, please refer to the s

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 14 AER.MT.GB.SOF.001.05.15 DIMENSIONS (mm) DIMENSIONS (mm) 21 31 38 41 81 21 31 38 41 81 A 660 1100 1100 1650 1650 M 708 1148 1148 1698 1698 B 700 700 700 900 900 N 570 1010 1010 1560 1560 C 320 320 320 375 375 O 60 60 60 60 60 D 240 240 240 300 300 P 285 285 285 385 385 E 20 20 20 25 25 Q 285 285 285 385 385

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 31 AER.MT.GB.SOF.001.05.15 10.15-Plenum with spigot (PS) The plenum with spigot can be installed both in outlet and in inlet; it is suitable for the connection of circular ducts. 10.16-Plenum for air regulation (PRA) The plenum for air regulation is installed in suction side and it allows the regulation of the air flow with pressure drop. The dumper is manually regulated. On request, it is possible to add the electric servo-control. DIMENSIONS (mm) 21 31 38 41 81 A 278 278 278 338 338 B 240 240 240 300 30

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 17 AER.MT.GB.SOF.001.05.15 9.4-Hydraulic connections and volume of coils HYDRAULIC CONNECTIONS 21 31 38 41 81 1 Main coil IN 3/4" 3/4" 3/4" 1" 1" 2 Main coil OUT 3/4" 3/4" 3/4" 1" 1" 3 Auxiliary coil IN 3/4" 3/4" 3/4" 3/4" 3/4" 4 Auxiliary coil OUT 3/4" 3/4"

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 24 AER.MT.GB.SOF.001.05.15 10.4-Flat flange (FP) The flat flange is necessary to connect the accessories of the group “D” (pls refer to the table at the beginning of the paragraph) to the outlet flange or to our FRA (inlet flange). 10.5-Inlet flange (FRA) The inlet flange is necessary to duct the suction. A filter with thickness 6-15-20-25mm can stay inside it; extraction fro

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 32 AER.MT.GB.SOF.001.05.15 10.17-Plenum with post-heating coil with 3 or 4 rows (PB3 – PB4) The post-heating plenum can be used in 4 pipe systems, when the auxiliary coils with 1 or 2 rows are not enough. The pressure drop, due to the post-heating coil, must be considered in the air flow capacity of the unit. POST-HEATING COIL SOFFIO 21 Air flow mc/h 500 600 700 800 900 1000 1100 Pressure drop PB3 Pa 10 13 16 20 27 28 32 Pr

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 25 AER.MT.GB.SOF.001.05.15 10.6-Inlet flange (FRAL) The inlet flange is necessary to duct the suction. A filter with thickness 6-15-20-25mm can stay inside it; extraction only from the side. UNIT DIMENSIONS (mm) 21 31 38 41 81 A 300 300 300 375 375 B 240 240 240 300 300 C 570 1010 1010 1560 1560 D 660 1100 1100 1650 1650 E 85 85 85 85 85 F 55 55 55 55 55 FILTER FILTER

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 22 AER.MT.GB.SOF.001.05.15 Pressure drop direct way diagram Pressure drop by-pass diagram 1 10 100 100 1000 10000 kPa l / h Kv=2,5 Kv=4,5 Kv=6,5 Kv=8 1 10 100 100 1000 10000 kPa l / h Kv=1,6 Kv=3,1 Kv=3,3 Kv=6,7

  • AERTESI srl SOFFIO – Technical manual Page 16 AER.MT.GB.SOF.001.05.15 DIMENSIONS (mm) DIMENSIONS (mm) 21 31 38 41 81 21 31 38 41 81 A 660 1100 1100 1650 1650 M 708 1148 1148 1698 1698 B 685 685 685 885 885 N 570 1010 1010 1560 1560 C 320 3

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 20 AER.MT.GB.SOF.001.05.15 PGM2 C X PGR C X PS D X (next FP) X (next FRA+FP) PRA D X (next FRA+FP) PB3 - PB4 C X SL C X (next FP) X (next FRA+FP) FRAF6 - 7 - 8 C X 10.1-Valves We suggest to use motorized valves in order to avoid condensation on the surface of the unit when the fan doesn’t work. The valves are supplied in kit, not mounted, to avoid damages during transport and/or installation. VALVES FOR MAIN COIL 21 31

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 18 AER.MT.GB.SOF.001.05.15 ETBN-6A Power relay board for SOFFIO 81 only O/VC/VD A EH Electric heater (installed inside the unit) O/VC/VD A EHR Relay for electric heater O/VC/VD A IPB Watertight electric box, on the same side of the water connections O/VC/VD A AERAULIC ACCESSORIES FP Flat flange (inlet or outlet) O/VC/VD A FRA Inlet flange with filter extraction from

  • AERTESI srl SOFFIO – Technical manual Page 11 AER.MT.GB.SOF.001.05.15 9- DIMENSIONS AND WEIGHTS 9.1-Dimensions and weights for horizontal version Standard version (right connections) R.A.= air inlet M.A.= air outlet E.F.= filter extraction Optional version (left connections) 1 M

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 7 AER.MT.GB.SOF.001.05.15 5-TECHNICAL DATA (AC motors) 5.1-Unit 2 pipes with 3 row coil EUROVENT certification not needed (*) 21 31 38 41 81 Speed (E) min med max min med max min med max min med max min med max Air flow (E) mc/h 508 752 880 1374 1555 1630 1619 1854 2009 2326 2722 3071 2980 3516 4037 Pressure (E) Pa 23 50 68 40 50 56 38 50 59 37 50 64 35 50 67 COOLING – air 2

  • AERTESI srl SOFFIO – Technical manual Page 12 AER.MT.GB.SOF.001.05.15 DIMENSIONS (mm) DIMENSIONS (mm) 21 31 38 41 81 21 31 38 41 81 A 660 1100 1100 1650 1650 M 708 1148 1148 1698 1698 B 550 550 550 650 650 N 570 1010 1010 1560

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 5 AER.MT.GB.SOF.001.05.15 3- KEY TO READING CODES The standard version is horizontal, single panel, 3 row coils, three-speed AC motor, right hydraulic connections. All other versions are optional.

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 8 AER.MT.GB.SOF.001.05.15 5.2-Unit 4 pipes with 3 row coil + 1 row auxiliary coil EUROVENT certification not needed (*) 21 31 38 41 81 Speed (E) min med max min med max min med max min med max min med max Air flow (E) mc/h 500 734 856 1344 1506 1582 1573 1798 1939 2312 2695 3033 2946 3453 3989 Pr

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 27 AER.MT.GB.SOF.001.05.15 10.9-Decorative inlet grill (GRD) The decorative inlet grill is used when the installation of the unit is unducted and you want to protect or hide the filter. It is made of galvanized steel, painted on request. The filter (thickness 15mm only) is inside. You can extract it by removing the decorative grill (through knobs). 10.10-Plenum 90° (P90) The plenum 90° can be installed both in outlet and inlet. DIMENSIONS (mm) 21 31 38 41 81 A 278 278 278 338 338 B 240 240 240 300 300 C

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 33 AER.MT.GB.SOF.001.05.15 10.18-Silenced plenum (SL) The silenced plenum can be used both in outlet and in inlet. The internal insulation is made of self-estinguish polyurethan foam ashlared film class HF1 (self-estinguish without drop) according to UL94. Noise absorbing performances are increased with internal insulated sectors. DIMENSIONS (mm) 21 31 38 41 81 A 278 278 278 342 342 B 240 240 240 300 300 C 570 1010 1

  • AERTESI srl SOFFIO – Technical manual Page 29 AER.MT.GB.SOF.001.05.15 10.12-Straight Plenum (PD) The straight plenum can be installed both in outlet and inlet. 10.13-Plenum with outlet grill (PGM2) The plenum with outlet grill with double regulation is used in case you need to direct the air flow in

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 15 AER.MT.GB.SOF.001.05.15 9.3-Dimensions and weights for vertical version VD Standard version (right pipe connections) R.A.= air inlet M.A.= air outlet E.F.= filter extraction Optional version (left connections) 1 Main coil IN 2 Main coil OUT 3 Auxiliary coil IN 4 Auxiliary coil OUT 5 Condensate drain

  • Aertesi SOFFIO, AERTESI srl SOFFIO – Technical manual Page 3 AER.MT.GB.SOF.001.05.15 10.14-Plenum with inlet grill (PGR) .............................................................................................................. 30 10.15-Plenum with spigot (PS) .................................................................................................................... 31 10.16-Plenum for air regulation (PRA) ......................................................................................................... 31 10.17-Plenum

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Kogan KADOK20PADAA Operation & user’s manual kogan/kadok20padaa-C16.pdf 09 Dec 2022 17
2 Kettler Top Assembly instructions manual kettler/top-668.pdf 09 Jun 2023 17
3 Braun HD 530 Operation & user’s manual braun/hd-530-722.pdf 10 Nov 2022 40 1.99 Mb
4 Pioneer PDR-W739 Operating instructions manual pioneer/pdr-w739-65O.pdf 30 Nov 2022 64
5 McCall 1-1020N Specifications mccall/1-1020n-I9T.pdf 13 Feb 2023 2
6 Omron BP760 Instruction manual omron/bp760-Y2A.pdf 13 Jan 2024 88

Similar Resources:

  • Samsung

    AW127JB

    (36 pages)
    ROOM AIR CONDITIONERAW126JB/127JBAW126JE/127JEAW12A6JD/12A7JDAIR CONDITIONER CONTENTS1. Precautions2. Product Specifications 3. Installation and Operating Instructions4. Disassembly and Reassembly5. Troubleshooting6. Exploded Views and Parts List7. Block Diagram 8. PCB Diagram9. Wiring Diagram 10. Schematic DiagramsSERVICEManual FANCOOLPOWER / MODE°CHourAW …
  • Samsung

    YH-925GS

    (9 pages)
    PORTABLE DIGITAL AUDIOPLAYERYH-925GSSERVICEManualPORTABLE DIGITAL AUDIO PLAYER CONTENTSSELMENU1. Exploded Views and Parts List2. Electrical Parts List3. Block Diagrams4. Schematic Diagrams- Confidential -* Application Model: YH-925GS/AAYH-925GS/AAWW,ELS,ELS,HA,HAOO,TSE,XA,TSE,XAC,XAHC,XAHYH-925GS/XAPYH-925GS/XAP,XAX,XEU,XAX,XEU,XF,XFA,XFOA,XFO,XSA,XSAYH-92 …
  • Daikin

    FTX-N Series

    (242 pages)
    [Applied Models]Inverter Pair : Heat PumpServiceManualSiUS091601EAInverter PairWall Mounted Type FTX-N/U SeriesFloor Standing Type FVXS-V SeriesDuct Connected Type FDMQ-R Series …
  • LG

    LT1233HNR

    (1 pages)
    LT1233HNRP/No.MEZ64830923Federal Law prohibits removal of this label before consumer purchase.Estimated Yearly Operating Cost $1058.8Energy Efficiency Ratio $61$127Cost Range of Similar Models Your cost will depend on your utility rates and use. Cost range based only on models of similar capacity without reverse cycle andwithout louvered sides.Estimated oper …
  • Toshiba

    RAV-RM301MUT-E

    (111 pages)
    FILE NO. A10-1811SERVICE MANUALAIR-CONDITIONER (SPLIT TYPE)INDOOR UNITPRINTED IN JAPAN, Mar., 2018 ToMo<Compact 4-way Cassette type>RAV-RM301MUT-E (TR)RAV-RM401MUT-E (TR)RAV-RM561MUT-E (TR) …
  • Mitsubishi

    MSH-07NV 2

    (4 pages)
    SERVICE MANUALSPLIT-TYPE,HEAT PUMP AIR CONDITIONERSCONTENTS1. TECHNICAL CHANGES ····································2 2. OUTLINES AND DIMENSIONS ························ 23. PARTS LIST ·······················································3Wire …

Comments, Questions and Opinions: