  • NOTINS0UK000055-V1.01 INSTALLATION GUIDE Uninterruptible power supply 13.7VDC - 2A Made in France AL02 ECO Non-contractual picture MOUNTING DIRECTION In accordance with our policy of continuous improvement of our products, the information contained in this manual may be subject to change without notice. ATLS can not be hel

  • Altec AL02 ECO, 2 INTRODUCTION Thank you for having purchased the uninterruptible power supply AL02 ECO of the trademark ALTEC. With the latest technological innovations, this product offers all the necessary protections against the short circuits, the overvoltage and the overcurrent. The auto-protected housing against opening and removal can have lead batteries type 12V-7Ah or 12V-2Ah. Its output voltage is regulated to 13,7V and its output current can reach 2A without battery backup. The charge current of the battery is electronically limited to 250mA. With this circuit, when the batte

  • Altec AL02 ECO, 3 WIRING SELV Secondary circuit with safety extra-low voltage A.P. TAMPER Tamper circuit for opening and removal. Before wiring the tamper, check if the circuit does not exceed 60VDC/0,1A. Ac in The output power failure « ERR. OUT (ACin)» goes from 0V to an open state during a power failure. ERR. OUT Batt The output low battery « ERR. OUT (Batt)» goes from 0V to an open state when the voltage of the battery exceeds the level of the low battery. - 0V of the power supply. If there are sev

  • Altec AL02 ECO, 4 TECHNICAL FEATURES Voltage power supply : 230VAC 50 Hz (-15% / +10%) Safety class : Class II Output voltage: 13.7VDC (+/-0.3VDC) Charge voltage of the battery : 13.7VDC (+/-0.3VDC) Charge current of the battery limited to : 0.25A Output current with internal battery : 1.75A Output current without internal battery : 2A Residual ripple of the output : < 250mVAC Current of the output for the light of the sector voltage : 25mA max. Current of the output for the light of the low battery : 25mA max Limit to trigger the low battery output : 12VDC Limit

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 HP ProDisplay P19A Specification hp/prodisplay-p19a-54Y.pdf 16 Feb 2024 8
2 HP iPAQ h1910 Reference manual hp/ipaq-h1910-GFV.pdf 02 Mar 2023 105
3 Vertical MBX IP Operation & user’s manual vertical/mbx-ip-G22.pdf 23 Dec 2023 70
4 Tricity Bendix FD 855 W Operating and installation instructions tricity-bendix/fd-855-w-59H.pdf 04 Aug 2022 20 1.02 Mb
5 NRX NRX-3 Operation & user’s manual nrx/nrx-3-YGX.pdf 10 Jul 2023 10
6 LG L1933TR-SF - - 19" LCD Monitor Service manual lg/l1933tr-sf-19-lcd-monitor-434.pdf 03 Nov 2022 35

Similar Resources:

  • Tripp Lite

    PDUMNH20HV

    (4 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] Number: PDUMNH20HVSingle-Phase Monitored PDU, 3.2-3.8kW 16/20A 200-240V, 1U Horizontal Rackmount, 8 C13 outlets, C20 inputwith L6-20P adapter HighlightsMonitored 16/20A 200-240V PDU, 1U horizontal rackmountReports voltage, frequency & load …
  • CyberPower

    CP1100AVRLCD

    (2 pages)
    Product User Manual and enterprise branch and head offices CP1500AVRLCD CYBERPOWERwww.enochsystems.com1-877-722-1116 [email protected] © 2013 Enoch Systems, LLC, Enoch Systems and the Enoch Systems logo are trademarks or registered trademarks of Enoch Systems, LLC and/or its affiliates in the U.S. a …
  • SynQor

    UPS-1250-S-1U

    (52 pages)
    1.888.567.9596 (USA only) | SynQor Headquarters 155 Swanson Road, Boxborough, MA 01719-1316 USA | www.synqor.comMade in USAUninterrUptible power SUpplyUPS-1250-S-1UUPS-1250-E-2UUPS-1250-S-2SOperator’s GuideUPS-1250 DC Output Series …
  • Eaton

    Power Xpert 9395P-1200

    (196 pages)
    Eaton® Power Xpert® 9395 High Performance (9395P-1200) UPS1200 kVA, 1200 kWInstallation and Operation ManualFor use with Three UPM (675–900 kVA) and Four UPM (1000–1200 kVA) UPS Models …
  • Vertiv

    LIEBERT PSI5 Series

    (8 pages)
    LIEBERT PSI5™ UPSQuick Installation User Guide590-2192-617A/SL-70358_REV0 1I M P O RTAN T: Before installing, connecting to supply or operating your Liebert PSI5TM UPS, please review the Safety and Regulatory Statements sheet. For detailed installation, operating, maintenance and troubleshooting information refer to the PSI5TM User Guide available at w …
  • Powercom

    1000A

    (4 pages)
    D:\manual\UM_PCM-BNT\661-BT1K-000.doc - 1 - U P S Uninterruptible Power System Line Interactive (Network) UPS 1000VA/ 1500VA/ 2000VA ■■■■USER‘S MANUAL■■■■ D:\manual\UM_PCM-BNT\661-BT1K-000.doc - 2 - IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS ●WARNING (SAVE THESE INSTRUCTIONS): Thi …