Manualios.com

Altherma EKHBXE008AA3V3 Installation Manual

Altherma EKHBXE008AA3V3 Manual Online:

3.5, 1821 votes
Altherma EKHBXE008AA3V3 User Manual
Altherma EKHBXE008AA3V3 User Guide
Altherma EKHBXE008AA3V3 Online Manual

Text of Altherma EKHBXE008AA3V3 User Guide:

  • Altherma EKHBXE008AA3V3, Installation manual 8 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B INSTALLATION OF THE INDOOR UNIT Selecting an installation location The unit is to be wall mounted in an indoor location that meets the following requirements: ■ The installation location is frost-free. ■ The space around the unit is adequate for servicing. (See figure 2). ■ The space around the unit allows for sufficient air circulation. ■ There is a provision for condensate drain (only for EKHBX models with drain pan kit EKHBDP) and pressure relief valve blow-off. ■ The installa

  • Altherma EKHBXE008AA3V3, Installation manual 12 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B Overview The illustration below gives an overview of the required field wiring between several parts of the installation. Refer also to "Typical application examples" on page 3. Internal wiring - Parts table Refer to the internal wiring diagram supplied with the unit (on the inside of the indoor unit switch box cover). The abbreviations used are listed below. A1P..................Main PCB A2P..................Remote controller PCB (us

  • Installation manual 18 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B ■ [1-03] Set point at high ambient temperature (Hi_Ti): the target outgoing water temperature when the outdoor temperature equals or rises above the high ambient temperature (Hi_A). Note that the Hi_Ti value should be lower than Lo_Ti, as for warmer outdoor temperatures (i.e. Hi_A) less war

  • EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B Installation manual 25 Error codes When a safety device is activated, the user interface LED will be flashing, and an error code will be displayed. A list of all errors and corrective actions can be found in the table below. Reset the safety by turning the unit OFF and back ON. In case this procedure fo

  • Installation manual 20 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B [8] Domestic water heating mode timer Applies only to installations with a domestic hot water tank. The 'domestic water heating mode timer' field settings defines the minimum and maximum domestic water heating times, and minimum time between two domestic water h

  • Altherma EKHBXE008AA3V3, Installation manual 14 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B Connection of the valve control cables Valve requirements ■ Power supply: 230 V AC ■ Maximum running current: 100 mA Wiring the 2-way valve 1 Using the appropriate cable, connect the valve control cable to the X2M terminal as shown on the wiring diagram. 2 Fix the cable(s) with cable ties to the cable tie mountings to ensure strain relief. Wiring the 3-way valve 1 Using the appropriate cable, connect the valve con

  • Altherma EKHBXE008AA3V3, EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B Installation manual 5 Domestic water heating Domestic water heating is as described under "Application 2" on page 4. Application 4 Space cooling and heating application without a room thermostat connected to the indoor unit, but with a heating only room thermostat controlling the floor heating and a cooling/heating thermostat controlling the fan coil units. Heating is provided through floor heating loops and fan coil units. Cooling is provided through the fan coil u

  • Altherma EKHBXE008AA3V3, EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B Installation manual 7 Switch box main components 1. Backup heater contactors K1M and K5M 2. Main PCB The main PCB (Printed Circuit Board) controls the functioning of the unit. 3. Booster heater contactor K3M (only for installations with domestic hot water tank) 4. Booster heater circuit breaker F2B (only for installations with domestic hot water tank) The circuit breaker protects the booster heater in the domestic hot water tank against overload or short circuit. 5. Backup heater circuit breaker F1B The circuit breaker protects the backup heater electrical circuit agains

  • EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B Installation manual 23 TEST RUN AND FINAL CHECK The installer is obliged to verify correct operation of the indoor and outdoor unit after installation. Automatic test run When the unit is put into operation (by pressing the y button) for the first time, the system will automatically perform a test run in co

  • Altherma EKHBXE008AA3V3, Installation manual 16 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B Pre-operation checks Checks before initial start-up After the installation of the unit, check the following before switching on the circuit breaker: 1 Field wiring Make sure that the field wiring between local supply panel and indoor unit, outdoor unit and indoor unit, indoor unit and valves (when applicable), indoor unit and room thermostat (when applicable), and indoor unit and domestic hot water tank has been carried out according to the instructio

  • Altherma EKHBXE008AA3V3, EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B Installation manual 19 [6] DT for domestic water heating Applies only to installations with a domestic hot water tank. The 'DT (delta temperature) for domestic water heating' field settings determine the temperatures at which heating of the domestic water by the heat pump will be started (i.e., the heat pump ON temperature) and stopped (i.e., the heat pump OFF temperature). When the domestic hot water temperature drops below the heat pump ON temperature (T HP ON ), heating of the domestic water by the heat pump CAN be started. As soon as the domestic hot water temp

  • Altherma EKHBXE008AA3V3, Installation manual 26 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B TECHNICAL SPECIFICATIONS General Electrical specifications P4 Electric component failure Contact your local dealer. PJ Failure of capacity setting Contact your local dealer. U0 Refrigerant failure (due to refrigerant leak) Contact your local dealer. U2 Main circuit voltage failure Contact your local dealer. U4 Communication failure Contact your local dealer. U5 Communication failure Contact your local dealer. U7 Communication failure Contact your local dealer. UA Communication failure Contact your local dealer.

  • Altherma EKHBXE008AA3V3, Installation manual 22 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B D Restricted power supply condition mode 00 Not applicable. Do not change the default value! 0 — — — 01 Not applicable. Do not change the default value! 0 — — — 02 Not applicable. Do not change the default value! 1 — — — E Unit information readout 00 Software version Read only ——— 01 EEPROM version Read only ——— 02 Unit model identification Read only ——— 03 Liquid refrigerant temperature Read only ——°C 04 Inlet w

  • Altherma EKHBXE008AA3V3, EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B Installation manual 11 Example 1 The indoor unit is installed 5 m below the highest point in the water circuit. The total water volume in the water circuit is 100 l. In this example, no action or adjustment is required. Example 2 The indoor unit is installed at the highest point in the water circuit. The total water volume in the water circuit is 350 l. Result: ■ Since 350 l is higher than 280 l, the pre-pressure must be decreased (see table above). ■ The required pre-pressur

  • Altherma EKHBXE008AA3V3, EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B Installation manual 9 Mounting the indoor unit 1 Fix the wall mounting bracket to the wall using appropriate plugs and screws. Make sure the wall mounting bracket is completely level. When the unit is not installed level, air might get trapped in the water circuit resulting in malfunctioning of the unit. Pay special attention to this when installing an EKHBX model to prevent overflow of the drain pan. 2 Hang the indoor unit on the wall

  • Altherma EKHBXE008AA3V3, Installation manual 2 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B Domestic hot water tank (option) An optional EKHW* domestic hot water tank with integrated 3 kW electrical booster heater can be connected to the indoor unit. The domestic hot water tank is available in three sizes: 150, 200 and 300 litre. Refer to the domestic hot water tank installation manual for further details. Drain pan kit (option) For heating/cooling versions (EKHBX), it is necessary to install the EKHBDP drain pan kit. For more information concerning the drain pan kit, refer to "In

  • Altherma EKHBXE008AA3V3, EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B Installation manual 17 Procedure To change one or more field settings, proceed as follows. 1 Press the z button for a minimum of 5 seconds to enter FIELD SET MODE. The $ icon (3) will be displayed. The current selected field setting code is indicated ; (2), with the set value displayed to the right - (1). 2 Press the bgi button to select the appropriate field setting first code. 3 Press the bgj button to select the appropriate field setting second code. 4 Press the

  • Altherma EKHBXE008AA3V3, EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system 4PW48441-1B Installation manual 1 C ONTENTS Page Introduction........................................................................................1 General information ...................................................................................1 Scope of this manual .................................................................................3 Model identification .................................................................................... 3 Accessories .......................................................................................3 Accessories supplie

More Instructions:

DOWNLOAD

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Epson EH-LS10000 Quick start manual epson/eh-ls10000-JZ3.pdf 05 Mar 2024 8
2 Mamas & Papas Barnie Instruction manual mamas-papas/barnie-452.pdf 13 Oct 2023 12
3 Standard C58 Instruction manual standard/c58-J8S.pdf 27 Oct 2022 71
4 Milwaukee 2707-20 Operator's manual milwaukee/2707-20-1WU.pdf 16 Jul 2023 11
5 OHAUS ST20C-A Instruction manual ohaus/st20c-a-1BL.pdf 02 Oct 2022 2
6 Craftsman 917.377411 Owner's manual craftsman/917-377411-831.pdf 03 Aug 2022 28

Similar Resources:

  • Daikin

    Altherma EDLQ011-016AA6V3

    (18 pages)
    • Altherma • Monobloc1• Monobloc • EDLQ011-016AA6V3TABLE OF CONTENTSEDLQ011-016AA6V31Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Nomi …
  • Dettson

    COND-UHD-09

    (15 pages)
    INSTALLATION INSTRUCTIONS ANDHOMEOWNER’S MANUALModels:COND-UHD-09COND-UHD-12COND-UHD-18COND-UHD-24INSTALLER / SERVICE TECHNICIAN:Use the information in this manual for the installation / servicing and keep the document near the furnacefor future reference.Communication wire connected between the indoor and outdoor units must be rated for at least 120VAC,th …
  • Trane

    IntelliPak RA 20

    (140 pages)
    SSAAFFEETTYY WWAARRNNIINNGGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioningequipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified personcould result in death or se …
  • LG

    LP090HED1

    (27 pages)
    LG PACKAGED TERMINALAIR CONDITIONER/HEAT PUMPOWNER'S MANUALLGhttp://www.lgservice.comPlease read the operating instructions and safety precautions carefullyand thoroughly before installing and operating your air conditioner.IMPORTANTPlease read through this manual. It contains valuableinformation about your air conditioner. This manualmay help save time …
  • Impecca

    IWA05KSP

    (2 pages)
    PREFERREDElectronic controlled MINIWINDOW air conditionerRemote Controlwith LED DisplayAuto RestartDriplessTechnologySleep ModeClean FilterIndicatorTIMETO CLEAN3 Cooling Speeds3 Fan-Only SpeedsLEDDisplayLEDEnergy SaverFunction$24 HourTimerPMTSIWA05KSP..........5,000 BTU IWA06KSP..........6,000 BTUEco-FriendlyRefridgerant …
  • Nailor

    92LFDF-SS

    (6 pages)
    Laminar Flow Ceiling Diffuser with FilterModels: 92LFDF-SS & 92LFDFS-AL Read completely and save these instructions for future reference.MANUALMANUAL I O M INstALLAtION, OperAtION & MAINteNANce …

Comments, Questions and Opinions: