Altherma EKHBHE008AA3V3 Operation Manual
|
Altherma EKHBHE008AA3V3, Operation manual 1 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B C ONTENTS Page Introduction ..................................................................................... 1 This manual ............................................................................................... 1 This unit ..................................................................................................... 1 Options ...................................................................................................... 1 Operating the
Altherma EKHBHE008AA3V3, EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B Operation manual 2 O PERATING THE UNIT I NTRODUCTION The AD heat pump system is designed to provide you a comfortable indoor climate for many years at low energy consumption. To get the most comfort with the lowest energy consumption out of your system, it is very important to observe the items listed below. Defining possible schedule timer actions for each day and filling out the form at the very end
Operation manual 3 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B Basic controller functions The basic controller functions are: ■ Tur ning the unit ON/OFF. ■ Operation mode change-over: - space heating (refer to page 5), - space cooling (refer to page 5) (*), - domestic water heating (refer to page 5) (*). ■ Selection of feat
Altherma EKHBHE008AA3V3, EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B Operation manual 4 17. BOOSTER HEATER ICON m This icon indicates that the booster heater is active. The booster heater provides auxiliary heating for the domestic hot water tank. The booster heater is located in the domestic hot water tank. The icon is not used when the domestic hot water tank is not installed. 18. PUMP ICON é This icon indicates that the circulation pump is active. 19. OUTDOOR TEMPERATURE DISPLAY u When this ico
Altherma EKHBHE008AA3V3, Operation manual 5 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B Description of the operation modes Space heating operation ( h) In this mode, heating will be activated as required by the water temperature set point. The set point can be set manually (refer to "Manual operation" on page 5) or weather dependent (refer to "Selecting weather dependent set point operation (only in heating mode)" on page 6). Startup (d) At the start of a heating operation, the pump is not started until a
EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B Operation manual 6 Selecting quiet mode operation (s) 1 Use the s button to activate quiet mode operation (s). Icon s appears on the display. If the controller is set in permission level 2 or 3 (refer to "Field settings" on page 11), the s button will not be operable. Selecting weather depend
Altherma EKHBHE008AA3V3, Operation manual 7 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B What can the schedule timer NOT do? The schedule timer can not change the operation mode from space cooling to space heating or vice versa. How to interpret the programmed actions To be able to understand the behaviour of your installation when the schedule timer is enabled, it is important to keep in mind that the "last" programmed command overruled the "preceding" programmed command and will remain active until the &
Altherma EKHBHE008AA3V3, EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B Operation manual 8 Programming Programming space cooling or space heating Programming space cooling or space heating is carried out as follows: 1 Use the = button to select the operation mode (cooling or heating) you want to program. 2 Press the < button. The actual mode is blinking. 3 Press the < button to confirm the selected mode. The actual day is blinking. 4 Select the day you would like to consult or to program by means of the pi and pj buttons. The selected day is blinking. 5 Press the < button to confirm the selected day. The first progra
Altherma EKHBHE008AA3V3, Operation manual 9 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B Programming quiet mode, booster heating or domestic water heating Programming domestic water heating, booster heater or quiet mode is carried out as follows: 1 Press the < button. The actual mode is blinking. 2 Use the pi and pj buttons to select the mode you want to program (quiet mode s, booster heating m or domestic water heating w). The selected mode is blinking. 3 Press the < button to confirm the selected mode. The first programmed action is displayed. 4 Use the pi and pj buttons to consult the programmed actions. This is called the readout mode. Empty program act
Altherma EKHBHE008AA3V3, EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B Operation manual 10 Consulting domestic water heating, booster heater or quiet mode Consulting domestic water heating, booster heater or quiet mode is carried out as follows. 1 Press the < button. The actual mode is blinking. 2 Use the pi and pj buttons to select the mode you want to consult (quiet mode s, booster heating m or domestic water heating w). The selected mode is blinking. 3 Press the < button to con
Altherma EKHBHE008AA3V3, Operation manual 11 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B FIELD SETTINGS The indoor unit should be configured by the installer to match the installation environment (outdoor climate, installed options, etc.) and user demand. Thereto, a number of so called field settings are available. These field settings are accessible and programmable through the user interface on the indoor unit. Each field setting is assigned a 3-digit number or code, for example [5-03], which is indicated on the
Altherma EKHBHE008AA3V3, EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B Operation manual 12 [2] Disinfection function Applies only to installations with a domestic hot water tank. The disinfection function disinfects the domestic hot water tank by periodically heating the domestic water to a specific temperature. ■ [2-00] Operation interval: day(s) of the week at which the domestic water should be heated. ■ [2-01] Status: defines whether the disinfection function is turned on (1) or off (0). ■ [2-02] Start time: time of the day at which the domestic water should be heated. ■ [2-03] Set point: high water temperature to be reached. ■ [2-04] Interval: time period de�
Altherma EKHBHE008AA3V3, Operation manual 13 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B [6] DT for domestic water heating Applies only to installations with a domestic hot water tank. The 'DT (delta temperature) for domestic water heating' field settings determine the temperatures at which heating of the domestic water by the heat pump will be started (i.e., the heat pump ON temperature) and stopped (i.e., the heat pump OFF temperature). When the domestic hot water temperature drops below the heat pump ON temperature (T HP ON ), heating of the domestic water by the he
EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B Operation manual 14 [8] Domestic water heating mode timer Applies only to installations with a domestic hot water tank. The 'domestic water heating mode timer' field settings defines the minimum and maximum domestic water heating times, and minimum time between two dome
Altherma EKHBHE008AA3V3, Operation manual 15 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B Field settings table First code Second code Setting name Installer setting at variance with default value Default value Range Step UnitDate Value Date Value 0 User permission level 00 User permission level 3 2/3 — — 1 Weather dependent set point 00 Low ambient temperature (Lo_A) –10 –20~5 1 °C 01 High ambient temperature (Hi_A) 15 10~20 1 °C 02 Set point at low ambient temperature (Lo_TI) 40
Altherma EKHBHE008AA3V3, EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B Operation manual 16 E Unit information readout 00 Software version Read only ——— 01 EEPROM version Read only ——— 02 Unit model identification Read only ——— 03 Liquid refrigerant temperature Read only ——°C 04 Inlet water temperature Read only ——°C First code Second code Setting name Installer setting at variance with default value Default value Range Step UnitDate Value Date Value
Operation manual 17 EKHBH/XE008AA3V3 Indoor unit for air to water heat pump system and options 4PW48442-1B MAINTENANCE Important information regarding the refrigerant used This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Refrigerant type: R410A GWP (1) value: 1975 (1) GWP = global warming potential Periodical inspections for refrigerant leaks may be required de
DOWNLOAD |
First Operations 300-1200 CFM Air Conditioner Application manual
300-1200 CFM |
Mitsubishi Electric MXZ-6C120VA Air Conditioner Installation manual
MXZ-6C120VA |
Altherma EKHBH016AA Air Conditioner Installation manual
EKHBH016AA |
Mitsubishi Electric MS-A18VD-K1 Air Conditioner Service manual
MS-A18VD-K1 |
Samsung SGH-S105 Air Conditioner Service manual
SGH-S105 |
HEIL CCA9 Air Conditioner Installation instructions manual
CCA9 |
Frigidaire FAP09EP1Z3 Air Conditioner Wiring diagram
FAP09EP1Z3 |
Friedrich P12B Air Conditioner Installation & operation manual
P12B |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Kemppi | Kempact MIG 2530 | Operating manual | kemppi/kempact-mig-2530-562.pdf | 28 Nov 2023 | 16 | |
2 | Philips | Sonicare ProtectiveClean 6100 | Operation & user’s manual | philips/sonicare-protectiveclean-6100-V7B.pdf | 01 Nov 2022 | 244 | |
3 | Toshiba | CF13F22 | Owner's manual | toshiba/cf13f22-8A6.pdf | 27 Oct 2023 | 20 | 1.51 Mb |
4 | WAGO | I/O System 750 Series | Manual | wago/io-system-750-series-8PC.pdf | 21 Sep 2022 | 48 | |
5 | Grundig | STRAIGHT & CURLS HS 9230 | Instruction manual | grundig/straight-curls-hs-9230-313.pdf | 15 Mar 2024 | 116 | |
6 | Heatmiser | JG PRT-E | Operating instructions manual | heatmiser/jg-prt-e-KBL.pdf | 15 Dec 2023 | 24 |
York
Commercial Air Conditioning SERVICE MANUAL Models Outdoor: YJU3YH019BARRA-X YJU4YH025BARRA-X YJU4YH030BARRA-X YJU5YH034BARRA-X YHKMXH009BARR-FX YHKMXH012BARR-FX YHKMXH018BARR-FX YHKMXH024BARR-FX YHFMXH012BARR-FX YHFMXH018BARR-FX YHFMXH024BARR-FX YHDMXH009BARR-FX YHDMXH012BARR-FX YHDMXH018BARR-FX YHDMXH024BARR-FXIndoor: MULTI Split serie …
YHKMXH009BARR-FX(137 pages) |
Toshiba
Installation manualAir conditioner (Split type) 1EnglishManuel d’installationClimatiseur (Type split) 16FrançaisAIR CONDITIONER (SPLIT TYPE)Installation manualBranch kit set 1:4Model name:RBC-DTWP101E
…
RBC-DTWP101E(17 pages) |
Samsung
ENGLISHSplit - type Air Conditioner (Cooling and Heating)SE FESPAÑOLFRANÇAISUSER’S MANUALAQV09N SeriesAQV12N SeriesAQV18N SeriesAQV24N SeriesDB98-29981A(2) Air Marketing Group LLC 141 Kinderkamack Rd, Park Ridge, NJ 07656 Tel: 201-782-178 …
AQV09N Series(28 pages) |
Mitsubishi Electric
Air ConditionersIndoor unitɄɨɧɞɢɰɢɨɧɟɪɵȼɇɍɌɊȿɇɇɂɃ ȻɅɈɄSLZ-M15, M25, M35, M50, M60FABRUKSANVISNINGVennligst les nøye gjennom denne bruksanvisningen, for sikkert og riktig bruk av klimaanlegget.INS7RUKC-A 2BSàUGI$E\]DSHZQLüEH]SLHF]QHLSUDZLGáRZHNRU]\VWDQLH]XU]ąG]HQLDQDOHĪ\ZF]HĞQLHMXZDĪQLHSU]H …
Mr.Slim SLZ-M15(37 pages) |
Whirlpool
THROUGH-THE-WALL AIR CONDITIONER Use & Care GuideFor questions about features, operation/performance, parts, accessories or service call: 1-800-253-1301.In Canada, call for assistance 1-800-461-5681, for installationand service, call: 1-800-807-6777or visit our website at... www.whirlpool.comor...www.whirlpoolappliances.caCLIMATISEUR ENCASTRÉ DANS LE MU …
1188177(32 pages) |
GE
GE is a trademark of the General Electric Company. Manufactured under trademark license.OWNER’S MANUALAIR CONDITIONERRV49-5000406 Rev. 1 01-20 GEASAFETY INFORMATION .........3INSTALLATION INSTRUCTIONSBefore You Begin ......................4Tools You will Need ....................4RARMN_ _ Parts List ...................5RAREN_ _ Parts List .......... …
ARC13AAC Series(54 pages) |
Kipor Inverter IG6000Kipor IG6000 Inverter Operation manual IG6000, 15 |
Buick Automobile 2002 LeSabre2002 LeSabre Owner's manual - 9IG5H1 2002 LeSabre, 398 |
D2 Mouse Penclic MouseMouse Manual (D2 Penclic Mouse) Penclic Mouse, 5 |
KUHN Farm Equipment GMD800GII-FFKUHN GMD800GII-FF Guide (Operator's manual), @4H67J3 GMD800GII-FF, 88 |
Mahindra Front End Loaders 2816 HSTUser Manual: Mahindra 2816 HST (638XEE, Upd.09.12.2023) 2816 HST, 142 |
Wide Monitor IDP2310UXWide Monitor Operation & user’s manual (File: wide-idp2310ux-monitor-44, 18.11.2023) IDP2310UX, 44 |
Makita Power Screwdriver BFS440Makita Power Screwdriver Instruction manual (File: makita-bfs440-instruction-manual-12, Saturday 23-09-2023) BFS440, 12 |
Nokia Cell Phone 6370 - Cell Phone - CDMA2000 1XNokia 6370 - Cell Phone - CDMA2000 1X Manual (Doc Type: Cell Phone Operation & user’s manual) 6370 - Cell Phone - CDMA2000 1X, 192 |
Sony Desktop VAIO Fit 14Operation & user’s manual for Sony VAIO Fit 14 Desktop VAIO Fit 14, 283 |
Icarus eBook Reader 8Icarus eBook Reader 8 Operation & user’s manual 8, 43 |
BW Technologies Measuring Instruments GasAlertQuattro 3BW Technologies GasAlertQuattro 3 User Manual (Doc Type: Measuring Instruments Operator's manual) GasAlertQuattro 3, 21 |
Craftsman Chainsaw 358.341161358.341161 Operator's manual - 4Y452C 358.341161, 32 |