Manualios.com

Apex Digital AIS750 Series Operation & User’s Manual

  • AIS750 Series Security System
  • maQOfESQhXgr.
  • Operation & User’s Manual
  • PDF / Adobe Acrobat Reader
  • 30

Apex Digital AIS750 Series Manual Online:

4.25, 2327 votes
Apex Digital AIS750 Series User Manual
Apex Digital AIS750 Series User Guide
Apex Digital AIS750 Series Online Manual

Text of Apex Digital AIS750 Series User Guide:

  • Both Engraving and translucent fi lm can be used for alarm labeling (alarm legends). Lens (or fi lm) replacement doesn’t need any special tools. Each window has surrounded with a plastic bezel. There is a small slot at the bottom of each window (behind plastic bezel) which allows a fl at terminal screwdriver to be used to gently lever the lens forward. To replace a window lens

  • Apex Digital AIS750 Series, ON 12345678 1 3 5 7 APEX Automation S olutions A I S Lo g ic car d 2 4 6 8 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 ON 1 2 3 4 5 6 7 8 Operation Mode Setting: Switch 1 On: Stand-alone 4 2 3 1 J13 The non alarm state of each individual channel can be configured to allow the channel to operate from either a NO or NC contact. AIS750 supports all ISA-S18.1/1979 (R1985) sequences. These sequences are Field Selectable for each Alarm Controller (Logic Card). For example for H11 type, each individual channel and for H21 type, each two channels will be confi gured at the same time. Flowchar

  • 24VDC power supply   Wiring Diagram Power Supply Wiring Typical wiring diagram of system power supply + - + - + - + - An external FUSE is strongly recommended as shown above. Depend on system options, every 7-10 Logic Cards (usually each row) needs one 24VDC power connection. One power connection for Interface module is mandatory. On standard systems

  • Apex Digital AIS750 Series, Input 1 Input 2 Input 3 Input 4 Dry Contact (potential free) Inputs 1212 1212   Wiring Diagram Alarm Iuput Wiring Depend on window type (H11, H21, H12, V21, H44), each Logic card supports 1, 2 or 4 inputs. Each Input should be confi gured individually to accept Dry (potential free) or powered contacts. Make sure all inputs have been confi gured properly before wiring the system, otherwise system will be damaged. Please ensure there is no external links between Input terminals and power supply terminals and wires. All “2” terminals are internally connected. Using this terminal for common wi

  • Apex Digital AIS750 Series, Bezel Clear lens White or coloured lens Legend fi lm Display body To replace a lens or fi lm, follow the lens replacement procedure in next pages. Screw Type Flush-mounting Clamp Panel   Annunciator Side View    AIS750 Series Annunciators (25) Each channel is equipped with its own removable lens assembly, which contains a clear lens, a laser printed fi lm legend (if applicable), a white or coloured lens and a plastic bezel on top of them. There are two options for alarm labeling; Engraving and using Translucent fi lm. Bellow diagram sh

  • Apex Digital AIS750 Series, Com. Module provides two individual ports, Com 1 and Com. 2 via a 4 pin pluggable connector (Com 2 is disabled in this system). Each port can be set as RS485 or RS232 as shown below. There is a Termination Jumper for RS485. This jumper should be short ONLY for END NODE (last unit in network). Communication Module (Com. Module) - optional: Com 1 APEX Automation Solutions Com. Module 123 123 123 123 C om 2 Com 1 APEX Automation Solutions Com. Module 123 123 123 123 C om 2 Termination Jumper: Must be close just for END NODE RS485 Setting RS232 Setting Com 1 Com 2 AIS750 Series Annunciators (1

  • Apex Digital AIS750 Series,     Interface Module Communication Module (optional) Interface & Communication Module Interface module communicates with Logic Cards and supports internal and external pushbuttons and provides common outputs such as internal buzzer, common alarm outputs such as First-up output, common Alarm Horn, etc. It also manages common functions such as system confi guration (through serial port) and communication protocols. There are two relays on Interface module. Function of these relays can be set by jumpers allowing the relays to operate as: Audible (Alarm Horn): Activates on alarm and remain active (within a group) until the Mute or Acknowledge pushbutton has

  • Apex Digital AIS750 Series, Coil Address Read-Write Function DNP Data Class DNP3 Address From 4001 to 5999 Write Serial Input Signal 10 0-1998 From 40001 to 40002 Read Interface Module Data 30 0-1 From 40003 to 40222 Read Logic Card Data 30 2-221 Coil Address Function 4001 Acknowledge All 4002 Reset All 4003 Mute All 4004 Test All 4101 to 4210 Single Point Acknowledge 4301 to 4410 Single Point Reset 4501 to 4610 Single Point Mute 4701 to 4810 Single Point Test 4901 to 4904, 4911 to 4914, … , 5991 to 5994 Single Inputg Signal Bits 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 40001 Interface module data First- Up Com. Alarm Crtcl. Horn Alarm Horn ----- - ------ 40

  • Wiring Diagram External (remote) Pushbuttons Wiring   1234 +24VDC (from same power source supplying the system) Acknowledge Reset Mute Test :Momentary Normally Open Pushbutton External (remote) pushbutton wiring diagram As an alternative, Pushbutton Module can be supplied as a remote item or the user can use conventional panel mounting momentary/normally open pushbuttons to control the An

  • Apex Digital AIS750 Series, Output 1 Output 2 Output 3 Output 4 Dry Contact (potential free) Outputs 1212 1212 Typical diagram of Repeat Relays Wiring   Wiring Diagram Repeat Relays Wiring output 1 output 2 output 3 output 4 1212 1212 output 1 output 3 output 4 output 2 Powered Outputs Individual channel Repeat Relays Each 4 channel Logic Card can be supplied with an optional 4 channel Relay Module (RM) to provide dry contact (potential free) contacts per alarm channel to be used with 3rd party devices. Each relay is equipped with a change-over contact and the user can se

  • Apex Digital AIS750 Series, ON 1234 APEX Automation Solutions AIS750 Interface Module 1357 2468 1357 2468 123 123 Relay 1 Relay 2 Relay 1 function setting Relay 2 function setting Interface Module DIP Switch setting: Standard Mode On Serial Mode Off ON 1 2 3 4 Node Address switch 2 switch 3 switch 4 1 2 3 4 5 6 7 ON Operation Mode switch 1   Interface Module Setting in Serial Mode: For operation in Serial mode, Interface module DIP switch m

  • Apex Digital AIS750 Series, AIS750 supports Modbus RTU-Slave, DNP3 Serial, DNP3 Ethernet and many other protocols including; Modbus TCP, BACnet MS/TP, BACnet IP, AB EtherNet IP, Allen Bradley EtherNet,AB DF1, SNMP, GE-EGD, GE-SRTP, GE-SNP, OPC, Omron Fins, Metasys N2 Open,... AIS750 Series Annunciators (23) +24VDC -0V RS485 (GND) RS485 (Data-) RS485 (Data+)  To Master (DNP3) Serial Communication Gateway (SCG) Serial communication wiring to Master DNP3 (RS485) RS485 Node 1 (Interface address 1) Node 2 (Interface address 2) Node 3 (Interface address 3) Mast

  • Apex Digital AIS750 Series, OPERATION MODE - Stand-alone (standard) Mode - Serial Mode with serial communication SYSTEM SETUP - In Stand-alone Mode: By DIP switches - In Serial Mode: Through ALCON software SERIAL COMMUNICATION Protocol: AIS750 supports Modbus RTU-Slave, DNP3 Serial, DNP3 Ethernet and many other protocols including; Modbus TCP, BACnet MS/TP, BACnet IP, AB EtherNet IP, Allen Bradley EtherNet, AB DF1, SNMP, GE-EGD, GE-SRTP, GE-SNP, OPC, Omron Fins, Metasys N2 Open,... Multi-drop RS485 communication is available. Up to

  • Apex Digital AIS750 Series, Relay Module (RM) Interface Module Logic Card Com. Module  Common Relays Com1 (RS485/RS232) Alarm Inputs Repeat Relay Outputs 24VDC External Pushbuttons       System Rear overview, Modules and Connectors AIS750 is an unparallel, modular, dual operation mode Annunciator. The annunciator is made up of windows, window being 75 x 50mm (3``x 2``). The type of cards installed dependent on system specifi cation and the required options. The following pages detail the system modules, individual cell types, available options and system setting. AIS750 Series Annunciators (4)

  • Apex Digital AIS750 Series, AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014) 3-350 John Street, Thornhill, Ontario L3T 5W6 Phone: 289 597 APEX (2739) Fax: 289 597 2200 Toll Free: 1 866 776 2943 Email: [email protected] Web: www.ANNUNCIATOR.ca AIS750 Series Annunciators (1)

  • Apex Digital AIS750 Series, ON 1 2 3 4 APEX Automation S olutions AI S 7 50 Int e r face M odu l e 1357 2468 1357 2468 123 123 R ela y 1 R ela y 2 Relay 1 function setting Relay 2 function setting 1357 2468 1357 2468 1357 2468 Horn 1 (Non-critical Alarm)   1357 2468 Horn 2 (Critical Alarm) First-up Common Alarm Common Relays Output Setting 123 123 Normally Open Output (NO) Normally Close Output (NC)   2 4 6 8 Common Relays Function Setting Interface Module Jumper settings for both operation modes (Stand-alone and Serial Modes): There are two relays on Interface module. Function of relays can be set by jumpers as showing bellow allowing th

  • Apex Digital AIS750 Series, APEX Automation Solutions Relay Module (RM) 123 123123 123 Relay 1 Relay 2 Relay 3 Relay 4 Individual channel Repeat Relays Each 4 channel Logic Card can be supplied with an optional 4 channel Relay Module (RM) which plugs into Logic Card and provides the user with a dry contact (potential free contact) per alarm channel for use with 3rd party devices. Each relay is equipped with a change-over contact and the user can select the contact state to NO or NC using a 3 way header and 2 way jumper a

  • Input 1 ON 1 2 3 4 5 6 7 8 1357 A PEX Automation S olutions AIS Lo g ic car d 2468 1357 2468 1357 2468 1357 2468 1 3 2 4 J13 Input 2 Input 3 Input 4 1357 2468 1357 2468 1357 2468 Dry Contact Input 24V(AC/DC) Input Other Voltage Input     2 4 6 8 1 3 2 4 1 3 2 4 1 3 2 4 1 3 2 4 1,2 Open: Alarm Group 1 (Non-critical) 3,4 Open: Repeat relays (input follower)

  • Apex Digital AIS750 Series, 6- Place the new lens inside the frame 7- Put the screwdriver inside the slot and push the lens in 8- Secure the lens 9- Put the plastic bezel back in place 10- Push the corners of plastic bezel AIS750 Series Annunciators (27)

  • Apex Digital AIS750 Series, Serial Mode DIP Switch setting: ON 1 2 3 4 5 6 7 8 Logic Card DIP Switch Setting in Serial mode Switch 1 On: Stand-alone Mod e Switch 1 Off: Serial Mode Switch 2-8: Address of Logic Card (window address) Logic Card Settings in Serial Mode: ON 12345678 1 3 5 7 APEX Automation S olutions AIS Lo g ic car d 2 4 6 8 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 1 3 5 7 2 4 6 8 4 2 3 1 J13  Card Address SW2 SW3 SW4 SW5 SW6 SW7 SW8 1 2 3

  • Apex Digital AIS750 Series, D- D+ GND TX RX GND MASTER AIS750 Series Annunciators D- D+ GND D- D+ GND RS485 Node 1 (Interface address 1) Node 2 (Interface address 2) Node 3 (Interface address 3) Master Multi-Drop Communication For Multi-Drop connection (connecting up to 7 annunciators to another device), each Interface Module in the system (each Annunciator) requires a unique address (node address), starting with “1” for the fi rst Annunciator, address “2” for second Annunciator, etc. Termination Jumper (see page 15) on Communication Module must be closed for END NODE. Multi-Drop Communication RS485 MODBUS communciation diagram (22) up to 7 annunciators Serial communication

  • Apex Digital AIS750 Series, Alarm Sequences Ring Back (Sequence Code R) Auto Reset First Out (Sequence Code F1A) With No Subsequent Alarm State Acknowledge while Abnormal (First-out Reset) Acknowledge while Normal (First-out Reset) First to Abnormal Return to Normal Subsequent to Abnormal P: Normal S: Normal V: Off A: Silent A w (F P: Abnormal or Normal S: Acknowledged V: On A: Silent P: Abnormal or Normal S: Alarm V: Flashing A: Audible Acknowledge while Abnormal return to normal Reset Acknowledge while Normal Return to Normal To Abnormal Return to Abnormal r

  • Apex Digital AIS750 Series, To reduce the power consumption an to provide a maintenance free solution, Each window is illuminated by almost unlimited life time “plug-in” LED Modules. Each LED module comes with two high bright, 120°, long life LEDs. Number of LED modules depends on window type. Generally, each H11 (large window) has 4 LED modules so, each H21 has 2 and each H44 has 1 LED module. No special tools needed to replace the LED modules. To remove and install LED modules, just a general purpose pointed plier is needed. Bellow picture show how to remove and install the LED modules. Make sure all 8 pins of LED

  • Apex Digital AIS750 Series, Alarm Sequences Manual Reset (Sequence Code M) Auto Reset (Sequence Code A) No Lock In To Abnormal Return to Normal P: Abnormal or Normal S: Alarm V: Flashing A: Audible Acknowledge while Abnormal Return to Normal T o P: Normal S: Normal V: Off A: Silent P: Abnormal or Normal S: Acknowledged V: On A: Silent To Abnormal Acknowledge while Normal Acknowledge while Abnormal Return to Normal T o o wled ge P: Normal S: Normal V: Off A: Silent Acknowledge P: Abnormal or Normal S: Alarm V: Flashing A: Audible P: Abnormal S: Acknowledge

  • Apex Digital AIS750 Series,     Logic Card Relay Module (optional) Depend on window type (H11, H21, H44, H12, V21), each Logic card supports 1, 2 or 4 inputs. Each logic card can be assigned to two different groups (Critical or Non-critical). Each Input can be confi gured individually to accept Dry (potential free) or Wet (powered) contacts. On standard system, user can select either Dry Contact or 24VDC signals. Another option is “Other Voltage”. Voltage of this option should be determined at the time of order. There ar

  • Apex Digital AIS750 Series, Output 1 Output 2 Dry Contact (potential free) Outputs 1212 Output 1 Output 2 External horn or buzzer wiring 1212   Wiring Diagram Alarm Output Wiring HORN There are two relays on Interface module. Function of theses relays can be set allowing the relay to operate as: - Audible: Activates on alarm and remain active (within a group) until the Mute or Acknowledge pushbutton has been pressed (Horn 1 / Horn2) - First-up: Activates when the fi rst alarm occurs - Common Alarm (Group Alarm): Once channels have been assigned to groups (Critical, Non-critical), the user is able to link a group to common relay. Each relay is equi

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Jenn-Air JRS207 Use and care manual jenn-air/jrs207-ZJ5.pdf 01 Feb 2024 19
2 Procom FBD400RTCC-M-HC/MO Owner's operation and installation manual procom/fbd400rtcc-m-hc-mo-LOI.pdf 02 Jun 2023 36
3 Hilti SFC 14-A Original operation instructions hilti/sfc-14-a-8QU.pdf 14 Mar 2023 15
4 GRAND RESORT Venetia Owner's manual grand-resort/venetia-R28.pdf 19 Mar 2023 24
5 Novell ADMINSTUDIO 9.5 Installation manual novell/adminstudio-9-5-W57.pdf 10 Dec 2023 28
6 Fujitsu PRIMERGY RX2540 M1 Upgrade and maintenance manual fujitsu/primergy-rx2540-m1-1G8.pdf 27 Oct 2023 438

Similar Resources:

  • Paradox

    SP5500

    (2 pages)
    Should you require any further information or assistance, please contact our office on 1300 928 241 QUICK SET UP GUIDE PARADOX SP5500 ALARM SYSTEMS Step 1: Intial Setup 1. Locate the Alarm panel (this will be located in a cupboard/WIR). 2. Open the panel and connect the battery, there will be a black and red lead loose, connect the black cable to bla …
  • Europlex

    3850

    (16 pages)
    INTRAMERICA SECURITY TECHNOLOGIES SCARBOROUGH, ONTARIO, CANADAM1B 3L6TEL (416) 754-4313FAX (416) 754-8992E-MAIL [email protected] AND OPERATION MANUAL FOR SUITEPLEX MODEL 3850CONCIERGE CONTROL PANEL(C) COPYRIGHT EUROPLEX LIMITED 1986REVISED: JANUARY 1998 …
  • Amico

    Alert-3 LCD v2.3

    (28 pages)
    Operating & Maintenance ManualAlert-3 LCD Alarm v1.9 www.amico.com1ST FLOORROOM 122ND FLOORROOM 253RD FLOOR ROOM 37MAINTEN EXT 3024TH FLOORROOM 475TH FLOORROOM 58 …
  • Q-See

    QT454

    (3 pages)
    Before You Get StartedA: Gather Your Components.You will need:1. A 19” or larger VGA PC monitor and VGA cable OR a television of any size.2. A surge protector We STRONGLY recommend that you use one that has the following specifications: • UL-1449 Rated • Clamping voltage of 330 or lower • Joule rating of at least 400 • Response time of 10 nan …
  • urmet domus

    1096

    (44 pages)
    DS1096-111 TELECAMERA DOME AHD 2M DAY & NIGHT OTTICA FISSA 3.6MM CON PIR 2M AHD DAY & NIGHT DOME CAMERA 3.6MM FIXED LENS BUILT-IN WITH PIR AHD 2M TAG & NACHT DOME KAMERA FESTOBJEKTIV 3.6 MM MIT PIR CAMÉRA DOME AHD 2M DAY & NIGHT OPTIQUE FIXE 3.6MM AVEV PIR Sch./Ref./Typ/Réf. 1096/303 MANUALE D’USO USER MANUAL BEDIENUNGSANL …
  • Protect

    FOQUS

    (28 pages)
    Version 1.5InstallationManualPROTECTGLOBAL.COMInstallation ManualManuel d’installationManuale installatoreManual de la instalaciónInstallationsmanualFIEGBDKItem no.: 21429_0001F …

Comments, Questions and Opinions: