Manualios.com

Arctic King WPPH-06CR5 Instruction Manual

Arctic King WPPH-06CR5 Manual Online:

3.7, 1064 votes
Arctic King WPPH-06CR5 User Manual
Arctic King WPPH-06CR5 User Guide
Arctic King WPPH-06CR5 Online Manual

Text of Arctic King WPPH-06CR5 User Guide:

  • Arctic King WPPH-06CR5, Portable Air Conditioner (Local Air Conditioner) Instruction Manual Model: WPPH-06CR5 WPPH-08CR5 WPPH-10CR5 Thank you for purchasing our Portable Air Conditioner. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. READ AND SAVE THESE INSTRUCTIONS!

  • Arctic King WPPH-06CR5, Preparation.............................................................................................................................................2 Safety Precautions.................................................................................................................................4 Cautions..................................................................................................................................................5 Installation...... ....................................

  • Arctic King WPPH-06CR5, Preparation rear front bottom tray drain outlet handle (both sides) air filter (behind the grille) upper air intake air outlet lower air intake drain outlet control panel remote signal receptor horizontal louver control lever(adjust manually) NOTE: PHA can not be adjusted. NOTE: PHA can not be adjusted. vertical louver control lever(adjust manually) panel Caster

  • Arctic King WPPH-06CR5, Safety Precautions -Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire. -Use only the included accessories and parts, and specified tools for the installation. Using non-standard parts can cause water leakage, electrical shock, fire, and injury or property damage. -Make sure that the outlet you are using is grounded and has the appropriate voltage. The power cord is equipped with a three-prong grounding plug to protect against shock. Voltage information can be

  • Arctic King WPPH-06CR5, Cautions -This appliance can be used by children aged from 8 years and above and person with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play the appliance. Cleaning and user maintenance shall not be made by children without supervision. (be applicable for the European Countries) -This appliance is not intended for use by persons (including childern) with reduced physical, sensory or mental capabilities or lack of experience

  • Arctic King WPPH-06CR5, Installation Choosing The Right Location Your installation location should meet the following requirements: -Make sure that you install your unit on an even surface to minimize noise and vibration. -The unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible. -The unit should be located at least 30cm (12”) from the nearest wall to ensure proper air conditioning. -DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this could cause damage to the unit. Note About Fluorinated Gasses -This air-conditioning u

  • Arctic King WPPH-06CR5, Installation Tools Needed -Medium Philips screwdriver; -Tape measure or ruler; -Knife or scissors; -Saw (optional, to shorten window adaptor for narrow windows) Accessories Your Window Installation Kit fits windows 67.5-123cm(26.5-48”) and can be shortened for smaller windows. Window Installation Kit Press the exhaust hose into the window slider adaptor and unit adaptor, clamp automatically by elastic buckles of the adaptors. Push the Exhaust hose into the airoutlet opening of the unit along the arrow direction. Step One: Preparing the Exhaust H

  • Arctic King WPPH-06CR5, Installation Note: Once the Exhaust Hose assembly and Adjustable Window Sliderare prepared, choose from one of the following two installation methods. Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown. Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown. Cut the non-adhesive foam seal C strip to match the width of the window. Insert the seal between the glass and the window f

  • Arctic King WPPH-06CR5, Installation If desired, install the security bracket with 2 screws as shown. Insert the window slider adaptor into the hole of the window slider. 2 Screws Security Bracket Note: To ensure proper function, DO NOT overextend or bend the hose. Make sure that there is no obstacle around the air outlet of the exhaust hose (in the range of 500mm) in order to the exhaust system works properly. All the illustrations in this manual are for explanation purpose only. Your air conditioner may be slightly different. The actual shape shall prevai

  • Operation MODE button Selects the appropriate operating mode. Each time you press the button, a mode is selected in a sequence that goes from COOL, FAN and DRY .The mode indicator light illuminates under the different mode setting. Used to adjust (increasing/decreasing) temperature settings in 1°C/1°F increments in a range of 17°C/62°F to 30°C/86°F.

  • Arctic King WPPH-06CR5, Operation Operation Instructions COOL operation -Press the "MODE" button until the "COOL" indicator light comes on. -Press the ADJUST buttons "+" or "-" to select your desired room temperature. The temperature can be set within a range of 17°C~30°C/62°F~86°F. -Press the "FAN SPEED" button to choose the fanspeed. DRY operation -Press the "MODE" button until the "DRY" indicator light comes on. -Under this mode, you cannot select a fan speed or adjust the temperature. The fan

  • Operation AUTO-RESTART If the unit breaks off unexpectedly due to the power cut,it will restart with the previous function setting automatically when the power resumes. WAIT 3 MINUTES BEFORE RESUMING OPERATION After the unit has stopped, it can not be restarted operation in the first 3 minutes. This is to protect the unit. Operation will automatically start afte

  • Arctic King WPPH-06CR5, Maintenance Safety Precautions Maintenance Tips -Always unplug the unit before cleaning or servicing. -DO NOT use flammable liquids or chemicals to clean the unit. -DO NOT wash the unit under running water. Doing so causes electrical danger. -DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer. Clean the Air Filter Clean the Unit Store the unit when not in use -Be sure to clean the air filter every 2 weeks for optimal performance. -The water collection tray shoul

  • Arctic King WPPH-06CR5, Faults Diagnosis Please check the machine according to the following form before asking for maintenance: Problem Possible Cause Troubleshooting Unit does not turnon when pressing ON/OFF button P1 Error Code Reset the temperature Turn off the unit and clean thefilter according to instructions Turn off the unit, disconnect thehose, check for blockage and reconnect the hose Call a service technician to inspectthe unit and top off refrigerant Decrease the set temperature Make sure all windows and doors are closed Turn off the unit and clean thefilt

  • Arctic King WPPH-06CR5, Design and Compliance Notes Design Notice Energy Rating Information In order to ensure the optimal performance of our products, the design specifications of the unit and remote control are subject to change without prior notice. The Energy Rating for this unit is based on an installation using an un-extended exhaust duct without adapters A or B (as shown in the Installation section of this manual). Unit Temperature Range Cool 17-35°C (62-95°F) Dry 13-35°C (55-95°F) Mode Temperature Range

  • Arctic King WPPH-06CR5, Sociable Remark DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separatelyfor special treatment is necessary.It is prohibited to dispose of this appliance in domestic household waste.For disposal, there are several possibilities:A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.B) When buying a new product, the retailer will take back the old product at least free of charge.C) The manufacture will take back the old appliance for disposal a

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Grizzly G4011 Instruction manual grizzly/g4011-M1L.pdf 15 Apr 2023 15 0.49 Mb
2 Robe Stage Faze 1500AT Operation & user’s manual robe/stage-faze-1500at-9RO.pdf 29 Jan 2023 9
3 Dell PowerConnect W Clearpass 100 Software Manual  dell/powerconnect-w-clearpass-100-software-AJ8.pdf 29 Jun 2023 10 1.06 Mb
4 CrimeStopper SV-5500 Installation instructions manual crimestopper/sv-5500-53Z.pdf 12 May 2023 8 0.1 Mb
5 Beko FSE 21300 Instruction manual beko/fse-21300-911.pdf 09 Feb 2023 16 4.27 Mb
6 ProForm PFEL04900 Operation & user’s manual proform/pfel04900-5L2.pdf 20 Sep 2022 20

Similar Resources:

  • Fujitsu

    ARYG12LHTBP

    (18 pages)
    SPLIT TYPEAIR CONDITIONERDUCT TYPE (50Hz)Indoor unit Outdoor unitARYG12LHTBPARYG14LHTBPAOYG12LBLAAOYG14LBLACONTENTSSPECIFICATIONS . . . . . . . . . . . . . . . . . .1DIMENSIONS. . . . . . . . . . . . . . . . . . . . . .2REFRIGERANT SYSTEM DIAGRAM . . .4ERROR DETECTION . . . . . . . . . . . . . . . .6CIRCUIT DIAGRAM. . . . . . . . . . . . . . . . .5PCB CIRCUI …
  • Samsung

    ASA24C5

    (64 pages)
    SERVICEManualCONTENTSAIR CONDITIONER1. Precautions2. Product Specifications3. Operating Instructions and Installation4. Disassembly and Reassembly5. Troubleshooting6. Exploded Views and Parts List7. Block Diagrams8. PCB Diagrams9. Wiring Diagrams10. Schematic DiagramsROOM AIR CONDITIONERINDOORASA24C5(6)MESC24AC5(6)ASA18C9(0)MESC18AC9(0)OUTDOORUSA24C5(6)MESC2 …
  • Lennox

    EL16XC1-036-230A01

    (108 pages)
    AIR CONDITIONERSEL16XC1ELITE® SeriesR-410A Bulletin No. 210758 July 2016 Supersedes May 2016SEER up to 17.901.5 to 5 TonsCooling Capacity - 17,800 to 60,000 BtuhMODEL NUMBER IDENTIFICATIONPRODUCT SPECIFICATIONSNominal Cooling Capacity 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 041 = 3.5 tons 042 = 3.5 tons 047 = 4 tons 048 = 4 tons 060 = 5 tons …
  • Focus

    SKY-3A

    (11 pages)
    INSTRUKCJA MONTAŻU I OBSŁUGIKARTA GWARANCYJNAKLIMATYZATOR PRZENOŚNY SKY-3AASSEMBLY AND MAINTENANCE INSTRUCTIONSPORTABLE AIR CONDITIONER SKY-3A!PL Należy sprawdzić wszystkie elementy przed montażem. Nie należy montować produktu w przypadku stwierdzenia uszkodzeń któregokolwiek z jego elementów!EN All elements should be checked before assembl …
  • Barker

    SPLIT AIR-CONDITIONER

    (35 pages)
    SPLIT AIR-CONDITIONEROWNER’S MANUALThank you for selecting our high quality Air Conditioner. To ensuresatisfactory operation for many years to come, this Owner’s Manual shouldbe read carefully before using air conditioner. After reading, store it in asafe place. Please refer to the manual for questions on use or in the event thatany irregularities occur. …
  • LG

    LT1030CR

    (48 pages)
    LG ROOM AIR CONDITIONEROWNER'S MANUALACONDICIONADOR DE AIRE DE VENTANAMANUAL DEL PROPIETARIOLGwebsite http://www.lgappliances.comPlease read the operating instructions and safety precautions carefullyand thoroughly before installing and operating your room air conditioner.Por favor lea las instrucciones de operación y las precauciones deseguridad cuida …