Blaupunkt Q3000 Installation Manual
|
Blaupunkt Q3000, Table of Contents 1. Introduction __________________________________________________________ 1 2. Installation ___________________________________________________________ 4 3. Troubleshooting & Factory Reset ________________________________________ 7 4. Specifications ________________________________________________________ 9 Information and illustrations are subject to change within this
Blaupunkt Q3000, 1 1. Introduction This document includes information to help you install and maintain your Q3000 alarm system and its accessory devices. For information about registration and system operation using Blaupunkt Home Connect cloud server. Please refer to “Blaupunkt Home Connection User Manual” which you can download from server home page https://eu.bphomeconnect.com/ Kit Contents Control Panel The Control Panel is the hub of your alarm system. It must be powered on and connected to internet at all times. When an alarm signal is transmitted from accesso
Blaupunkt Q3000, 2 Accessories Door Contact The Door Contact is mounted on the Door or Window frame to detect door/window opening. When triggered, it will transmit a signal to Control Panel to alert the condition LED Indicator: The LED will light up if the Door Contact is triggered under tamper open or low battery status to signal fault. Learn / Test Button: The Learn / Test button is used to send signal for learning Door Contact or test range. Tamper Switch: The tamper switch is compressed against
Blaupunkt Q3000, 3 Tamper Switch: The tamper switch is located inside the PIR and depressed against the back cover. It will be activated when the back cover is opened. System Extension Aside from the devices included in the package, you can further improve the capability of your alarm system by purchasing extra accessories. Such as extra PIR Sensor or Door Contract to extend your protection area; Remote Keypad for a secondary system operation platform; Smoke Detector for fire protection; Temperature Sensor for temp
Blaupunkt Q3000, 4 2. Installation Before proceeding to install your accessory devices, you should first complete system registration on Blaupunkt Home Connect server. Please refer to the Quick Start Guide or server user manual to complete the registration process and log into your user account. Signal Range and Walk Test All accessory devices in the Q3000 alarm kit uses wireless radio protocol to communicate with the Control Panel to save you from the extra labour of wiring the device to panel. All devices in the alarm system have an approximate range of 30 meters in typical domestic environment. The range may vary depend
Blaupunkt Q3000, 5 Device Location Panning: PIR Sensor ➢ Mount the PIR Sensor at 1.9-2m height for best performance. When mounted at 2m height, the PIR sensor has a range of 12m. ➢ PIR Sensor detection is most effective when the intruder is moving across its field of view from the sides. Do not mount PIR sensor in a location that faces intruder directly. ➢ Do not mount the PIR Sensor directly exposed to sunlight, which may affect detection sensitivity. �
Blaupunkt Q3000, 6 Mounting Door Contact 1. Pull out the plastic battery insulator on the back to activate battery and power on Door Contact. 2. The Door Contact should be mounted on the door/window frame, while the magnet should be mounted on the door/window aligned with the Rib Mark on the Door Contact. The gap between the Door Contact and the magnet should be no more than 15 mm. 3. Choose to install the Door Contact with either screw or adhesive tape Screw Mounting The Door Contact has two knockouts on the inside of the back cover where plastic is thinner for wall mounting. 4. Open the Door Co
Blaupunkt Q3000, 7 3. Troubleshooting & Factory Reset This chapter covers the potential issues you may encounter during system operation, and factory reset function Control Panel Control Panel Fault Orange LED indicates fault in system, When the LED light up, please login to your Blaupunkt Home Connection Server account to check fault events. The possible fault events include: Control Panel / Devices low battery: -- Change device batteries or charge Control Panel battery accordingly. AC power fail: -- Check AC power connection Sensor out of order: -- Check device battery status and conduct Walk Test to confirm if the Control Panel
8 Factory Reset The Factory Reset function will clear all device info and returns all system parameter to default value. After resetting you will need to setup the system by following the instruction in server user manual. 1. Power down Control Panel by disconnecting AC Power and switching off battery switch. 2. Apply AC Power while holding down the button on the back. 3
9 4. Specifications All Devices Environmental Condition -10°C to 40°C, relative humidity 85% non-condensing for Control Panel and all devices. Radio Operation Range About 30m in typical domestic installation, range varies depending on building construction, device location, and environment. Control Panel Siren Output 96 dBA sound pressure @ 1m minimum Zones 40 radio
10 Compliance Statement Declaration of Conformity This device complies with the requirements of the R&TTE Directive 1999/5/EC and the following harmonized standards have been applied: Health: EN62479:2010 Safety: EN60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 EMC: EN 301 489-1 V1.9.2:2011 EN 301 489-3 V1.6.1:2013 EN 301 489-17 V2.2.1:2012
Menvier Security TS510 Security System Installation manual
TS510 |
DeWalt DE0892-XE Security System Instruction manual
DE0892-XE |
Blaupunkt SA 2500 Security System Brochure & specs
SA 2500 |
Blaupunkt Q SERIES Security System Installation and operation manual
Q SERIES |
Blaupunkt SR-S1 Security System Manual
SR-S1 |
DSC PC1550 Security System Instruction manual
PC1550 |
Blaupunkt SA 2500 Security System Operation & user’s manual
SA 2500 |
SunEyes Mini NVR Security System Quick start manual
Mini NVR |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Tiger | Mini Action Game Hagrid 36287 | Instruction | tiger/mini-action-game-hagrid-36287-4UV.pdf | 07 Sep 2022 | 2 | 0.41 Mb |
2 | Microchip Technology | dsPICDEM 1.1 Plus | Operation & user’s manual | microchip-technology/dspicdem-11-plus-XIX.pdf | 02 Dec 2022 | 93 | |
3 | LUCCI | 210012 | Installation instructions manual | lucci/210012-E61.pdf | 21 Jun 2023 | 7 | |
4 | Allied Telesis | AT AR750S AT-AR750S AT-AR750S | Datasheet | allied-telesis/at-ar750s-at-ar750s-at-ar750s-DGH.pdf | 01 Jan 2024 | 5 | 0.14 Mb |
5 | Addonics Technologies | ADSA4R-E | Operation & user’s manual | addonics-technologies/adsa4r-e-66M.pdf | 03 Sep 2022 | 1 | 0.01 Mb |
6 | Viconics | VT8300 Series | Installation manual | viconics/vt8300-series-OT4.pdf | 04 Dec 2023 | 12 |
NexSens
G2RAIN ALERT SYSTEMQUICK START GUIDEIMPORTANT - BEFORE FIELD DEPLOYMENT: Completely configure new G2 systems with a web connection in a near-by work area. Operate the system for several hours and ensure correct sensor readings. Use this test run to become familiar with the features and functions. To get started:a. Go to WQDataLIVE.comb. Create a new …
G2-RAIN(2 pages) |
Hawk
HA - 280 PROINSTALLERʼS MANUALManufacturer:COMMERCIAL ELECTRONICS264 HAYDONS ROAD, WIMBLEDON, LONDON SW19 8TT. UKTEL: +44 020 8404 7105 FAX: +44 020 8404 7104http://www.hawkcaralarm.com e-mail: [email protected] - 280 PROINSTALLERʼS MANUALManufacturer:COMMERCIAL ELECTRONICS264 HAYDONS ROAD, WIMBLEDON, LONDON SW19 8TT. UKTEL: +44 020 8404 7105 F …
HA-CH01(8 pages) |
Abus
Funk-Innensirene Installationsanleitung Wireless internal siren Installation instructions Sirène radio intérieure Instructions d’installation Draadloze binnensirene Installatie-instructies Sirena interna radio Istruzioni per l’installazione Trådløs indendørs sirene Installationsvejledning Radiowa syrena wewnętrzna Instrukcja instalacji FU 823 …
FU 8230(48 pages) |
Magtek
MagTek I 1710 Apollo Court I Seal Beach, CA 90740 I Phone: (562) 546-6400 I Technical Support: (888) 624-8350 www.magtek.com DynaPro Go Handheld PIN Pad Device with MSR/Contact/Contactless Programmer’s Manual (COMMANDS) April 2021 Document Number: D998200136-31 REGISTERED TO ISO 9001:2015
…
DynaPro Go(247 pages) |
Argus Security
[email protected] L20-SGCP1IS-0001 (vA.4) www.argussecurity.it ARGUS SECURITY S.R.L., Via del Canneto, 14 - 34015 - Muggia (TS) - Italy SGCP100-IS INTRINSICALLY SAFE WIRELESS CALL POINT GENERAL DESCRIPTION The intrinsically safe wireless call point is a wall mounted device that, when activated, initiates an alarm on the fire security system. Its constr …
SGCP100-IS(2 pages) |
Costar
Carbon Monoxide Gas Alarm12-24Vdc SystemPLEASE READ AND SAVEOWNER’S MANUALModel 12-24SIRDear New COSTAR®12-24SIR Owner,Congratulations as you have taken steps to help insure thehealth and life safety of you and your family. We are proud to offeryou our unique, patented CO Sensor technology that detects CO in amanner similar to the human body’s response …
12-24SIR(4 pages) |
Zanussi Refrigerator ZI 9330 BZI 9330 B Instruction booklet - UF72D2 ZI 9330 B, 14 |
Mitsubishi Air Conditioner PQHY-P200YGM-AAir Conditioner #5785D3 PQHY-P200YGM-A, 108 |
Panasonic Plasma TV TH-42PZ80UTH-42PZ80U Quick start manual - 4U6935 TH-42PZ80U, 50 |
Fellowes Paper Shredder C-480CxManual: Fellowes C-480Cx (G51835, Upd.16.11.2023) C-480Cx, 10 |
Weed Eater Trimmer Twist N' Edge 530083927Operator's manual for Weed Eater Twist N' Edge 530083927 Trimmer Twist N' Edge 530083927, 6 |
Liebert Power Supply GXT2-6000 RT208Power Supply PDF Operation & user’s manual GXT2-6000 RT208, 52 |
Henkel Oven K-450Henkel Oven K-450 Installation instructions & repair parts list K-450, 8 |
EVOKO Touch Panel Room ManagerRoom Manager (Touch Panel ePDF Guide, #1XVJW9) Room Manager, 30 |
Furuno Sonar CH-250Furuno Sonar Installation manual (File: furuno-ch-250-installation-manual-79, 12th Oct 2023) CH-250, 79 |
Electrolux Dishwasher FAVORIT 89020 VIFAVORIT 89020 VI Operation & user’s manual - RW2SQ2 FAVORIT 89020 VI, 32 |
Panasonic Monitor TH-37PR10R#EUK73X TH-37PR10R: Panasonic Monitor Owner Documentation TH-37PR10R, 52 |
Triarch Light Fixture Lighting Fixture 32045#X5TMPY Lighting Fixture 32045: Triarch Light Fixture Owner Documentation Lighting Fixture 32045, 3 |